SSSi Young Song

Si Young Song

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Si Young Song has a total of 114 co-authors. Here are the top co-authors by number of shared publications:

  • Young-Jin Seo

    Department of Orthopedic Surgery, Dongtan Sacred Heart Hospital, Hallym University College of Medicine, Hwaseong, Republic of Korea

    8 shared publications
  • Young‐Jin Seo

    Department of Orthopaedic Surgery Dongtan Sacred Heart Hospital Hallym University College of Medicine Hwaseong Republic of Korea

    6 shared publications
  • Jeehyoung Kim

    Department of Orthopedic Surgery, Seoul Sacred Heart General Hospital, Seoul, Republic of Korea

    5 shared publications
  • Yoon Sang Kim

    BioComputing Lab, Institute for Bio-Engineering Application Technology, School of Computer Science and Engineering, Korea University of Technology and Education (KOREATECH), Cheonan, Republic of Korea

    5 shared publications
  • Young-Jin Seo

    Department of Orthopedic Surgery, Dongtan Sacred Heart Hospital, Hallym University College of Medicine, Hwaseong, Republic of Korea

    5 shared publications
  • Hyobeom Lee

    Department of Orthopaedic Surgery, Center for Joint Diseases, Kyung Hee University Hospital at Gangdong, Seoul, Republic of Korea

    4 shared publications

Latest Publications

  • Open Access

    A Comparative Analysis of GPT-3.5, GPT-4, GPT-4 Omni, Gemini Advanced, and Gemini 1.5 in Answering Total Knee Replacement−Related Questions

    by Hyobeom Lee, Ji-Sun Shin, Young Jin Seo, Seong Hyeon Kim, Jongryul Lee, Seung Yong Shin, Si Young Song

    Background: Artificial intelligence (AI) chatbots are increasingly used for medical information provision. However, systematic evaluations of their accuracy and reliability in orthopaedic surgery, particularly in total knee replacement (TKR), remain limited. Purpose: To systematically compare and evaluate performances of various AI chatbots, focusing on their ability to provide accurate and reliable information related to TKR. Study Design: Cohort study; Level of evidence, 2. Methods: A total of 43 clinically relevant TKR-related frequently asked questions (FAQs) were selected based on Google search trends and expert consultation. Questions were categorized into 6 key domains: (1) general/procedure-related information, (2) indications and outcomes, (3) risks and complications, (4) pain and postoperative recovery, (5) specific activities after surgery, and (6) alternatives and variations. Each question was submitted to 5 different chatbot models (GPT-3.5, GPT-4, GPT-4 Omni, Gemini Advanced, and Gemini 1.5) for response generation. Two independent orthopaedic surgeons assessed the chatbot's responses for both accuracy and relevance using a 5-point Likert scale. Responses were anonymized, blinding evaluators to the chatbot identities to prevent bias. Accuracy differences among the chatbot models were analyzed by analysis of variance, and relevance was compared using the Kruskal-Wallis test. Results: GPT-3.5 (4.8 ± 0.5), GPT-4 (4.9 ± 0.4), GPT-4 Omni (4.9 ± 0.3), and Gemini 1.5 (4.8 ± 0.4) demonstrated high accuracy, whereas Gemini Advanced scored significantly lower (4.1 ± 1.4) ( P < .001). However, general/procedure-related information, risks and complications, pain and recovery, and postoperative activities showed no significant differences among chatbots. Gemini Advanced underperformed in indications and outcomes ( P = .04) and alternatives and variations ( P = .002). Regarding relevance, all chatbots except Gemini Advanced (36/43; 83.7%) achieved a 100% relevance rate ( P < .001). Conclusion: This study demonstrates that GPT-3.5, GPT-4, GPT-4 Omni, and Gemini 1.5 can provide highly accurate and relevant responses to TKR-related queries, while Gemini Advanced underperforms.


  • Open Access

    A Comparative Analysis of GPT-3.5, GPT-4, GPT–4 Omni, Gemini Advanced, and Gemini 1.5 in Answering Frequently Asked Questions Regarding High Tibial Osteotomy

    by Seong Hyeon Kim, Ji-Sun Shin, Hyobeom Lee, Seung Yong Shin, Ki Man Kang, Si Young Song

    Background: Large language model (LLM)–based chatbots, such as ChatGPT and Gemini, have become widely used sources of medical information. No study has assessed the performance of LLM chatbots in providing clinically reliable information on high tibial osteotomy (HTO). Purpose: To evaluate the accuracy and relevance of different LLM chatbots in responding to frequently asked questions (FAQs) about HTO. Study Design: Cross-sectional study. Methods: A total of 35 FAQs about HTO were curated from online sources and categorized into 6 categories: general/procedure related, indications for surgery and outcomes, risks and complications of surgery, pain and postoperative recovery, specific activities after surgery, and alternatives to and variations of HTO. These questions were used as input to 5 different LLM chatbots: ChatGPT-3.5, ChatGPT-4, ChatGPT–4 Omni, Gemini Advanced and Gemini 1.5. Responses were collected from July 12 to 14, 2024 (ChatGPT-3.5, ChatGPT-4, ChatGPT–4 Omni, and Gemini Advanced) and on September 26, 2024 (Gemini 1.5). Two independent orthopaedic surgeons assessed the responses using a 5-point Likert scale (1 = very incorrect/very irrelevant, 5 = very accurate/very relevant). Responses were anonymized to blind evaluators to chatbot identities. Differences in accuracy among chatbots were assessed using analysis of variance, and differences in relevance using the Kruskal-Wallis test. Results: LLM chatbots demonstrated the following mean accuracy scores: GPT-3.5 (4.66 ± 0.64), GPT-4 (4.66 ± 0.54), GPT–4 Omni (4.94 ± 0.24), and Gemini 1.5 (4.86 ± 0.36), while Gemini Advanced showed significantly lower scores (3.83 ± 1.40) ( P < .001) in answering HTO-related FAQs. Particularly, Gemini Advanced exhibited lower accuracy scores in the categories of indications and outcomes ( P = .002) and alternatives and variations ( P = .015). There were no significant differences among the models regarding general/procedure related ( P = .12), risks and complications ( P = .50), pain and postoperative recovery ( P = .53), and specific activities after surgery ( P = .09). All models provided relevant answers to all questions (35/35; 100%), except for Gemini Advanced (30/35; 85.7%). Conclusion: This study showed that ChatGPT-3.5, ChatGPT-4, ChatGPT–4 Omni, and Gemini 1.5 provided accurate and relevant responses on HTO, whereas Gemini Advanced exhibited limitations and underperformed in comparison with the other models.


  • Open Access

    Propensity Score-Matched Comparison of Six-Strand All-Inside and Conventional Four-Strand Hamstring Autografts for ACL Reconstruction

    by Young Jin Seo, Si Young Song, Dongju Kim

    Background/Objectives: All-inside ACL reconstruction has emerged as a minimally invasive alternative to conventional techniques, with potential advantages in graft configuration and reduced surgical trauma. This study aimed to compare the clinical outcomes of all-inside and full tibial tunnel ACL reconstruction, focusing on graft diameter, postoperative stability, and functional recovery. We hypothesized that the all-inside technique would allow for thicker grafts and yield superior postoperative knee stability and functional outcomes, with postoperative anterior laxity as a major outcome of interest. Methods: This retrospective comparative study reviewed patients who underwent ACL reconstruction between January 2020 and February 2024. From January 2020 to September 2022, a four-strand hamstring autograft with full tibial tunnel technique (FT-4) was used, while from September 2022, a six-strand hamstring autograft with the all-inside technique (AI-6) was adopted to enable thicker grafts and optimize fixation. Among a total of 103 patients, 1:1 propensity score matching (PSM) was performed based on age, sex, BMI, laterality, ALL reconstruction, meniscal lesion, and preoperative anterior laxity (SSD). Graft diameter and clinical outcomes, including knee stability and functional scores, were compared between the matched groups. Results: After PSM, two comparable groups of 29 patients each were established. Graft diameter was significantly larger in the AI-6 group (9.5 ± 0.7 mm) compared to the FT-4 group (7.8 ± 0.8 mm, p < 0.001), while other baseline characteristics remained well balanced between the groups. At the final follow-up, both groups exhibited significant improvements in anterior laxity, functional scores, and pivot shift grades (all p < 0.001). The AI-6 group demonstrated superior outcomes with a significantly higher Lysholm score (82.2 ± 6.7 vs. 75.6 ± 8.9, p = 0.002), lower WOMAC score (8.0 ± 4.3 vs. 12.9 ± 10.5, p = 0.023), and reduced anterior laxity (1.6 ± 1.1 mm vs. 2.5 ± 1.4 mm, p = 0.005) compared to the FT-4 group, whereas no significant differences were observed in the IKDC, Tegner, Korean knee score, or pivot shift test results. A simple linear regression revealed a significant negative correlation between graft diameter and postoperative anterior laxity (B = −0.398, p = 0.048). Conclusions: The present study demonstrated that the use of a six-strand hamstring graft configuration in the AI-6 technique resulted in significantly thicker grafts and was associated with reduced postoperative anterior knee laxity compared to the FT-4 technique. While interpretation of these findings requires caution in light of MCID thresholds, the AI-6 group showed favorable outcomes in anterior laxity and selected functional scores, such as the Lysholm and WOMAC. This technique may offer practical clinical value, particularly in populations prone to smaller graft diameters, as it facilitates adequate graft thickness through multifold preparation, with the all-inside approach accommodating the inherent graft shortening.

  • Open Access

    Epigallocatechin-3-Gallate (EGCG)-Loaded Hyaluronic Acid Hydrogel Seems to Be Effective in a Rat Model of Collagenase-Induced Achilles Tendinopathy

    by Hwa Jun Kang, Sivakumar Allur Subramanian, Si Young Song, Jihyun Hwang, Collin Lee, Sung Jae Kim

    Tendon injuries account for 45% of musculoskeletal injuries. However, research on the occurrence and pathogenesis of tendinopathy is insufficient, and there is still much debate regarding treatment methods. It is important to understand the molecular mechanisms of oxidative stress and inflammatory responses because oxidative stress in tendon tissue is induced by various factors, including inflammatory cytokines, drug exposure, and metabolic abnormalities. In this study, 28 rats were divided into four groups (7 rats assigned to each group): control group (CON), collagenase injection group (CL), collagenase injection and hyaluronic acid injection group (CL + HA), and collagenase injection and EGCG-loaded hyaluronic acid injection group (CL + HA + EGCG). Seven weeks after the start of the study, all rats underwent histochemical analysis, immunofluorescence staining, and Western blot. The results showed increased inflammatory cells, disarray of collagen matrix, and degradation of the collagen matrix in the CL group. However, in the EGCG-treated group, there was a significant increase in type I collagen expression and a significant decrease in type III collagen expression, compared to the CL group. Additionally, there was an increase in the expression of antioxidant markers SOD (Superoxide Dismutase) and CAT (Catalase), tenogenic markers COLL-1 (collagen type I), and SCX (Scleraxis), and a downregulated expression of apoptosis markers cas-3 and cas-7. Our findings suggest that EGCG-loaded hyaluronic acid hydrogel exhibits potential in preventing tendon damage and promoting the regeneration process in a rat model of Achilles tendinopathy. The insights gained from our histological and molecular investigations highlight the future potential for testing novel tendinopathy treatments in human subjects.


  • Open Access

    Clinical and Radiological Outcomes After Isolated Double-Bundle Medial Patellofemoral Ligament Reconstruction: A 5-Year Analysis

    by Sung-Yup Hong, Seounghyeon Kim, Hyo-Beom Lee, Won-Ho Song, Jeehyoung Kim, Young-Jin Seo, Si Young Song

    Background: There are few studies that have examined clinical and radiological outcomes at 5 years after isolated medial patellofemoral ligament (MPFL) reconstruction. To date, midterm outcomes after isolated double-bundle (DB) MPFL reconstruction are not well known. Hypothesis: Isolated DB MPFL reconstruction using a patellar suture anchor technique would lead to improved functional scores and radiological findings, and these improvements would remain stable over the 5-year postoperative period. Study Design: Case series; Level of evidence, 4. Methods: Isolated MPFL reconstruction was performed in patients with recurrent patellar instability between March 2013 and February 2017. Clinical and functional evaluations were performed via an interview using the Kujala, Lysholm, and Tegner scores preoperatively and at 6, 12, 24, and 60 months postoperatively. Radiographs were taken preoperatively, immediately postoperatively, and at 24 and 60 months after surgery. Radiographic assessments included measuring the modified Insall-Salvati ratio, congruence angle, and lateral patellofemoral angle. Results: A total of 31 patients (31 knees) underwent isolated MPFL reconstruction; 4 patients did not complete 5-year follow-up, and thus, 27 patients (27 knees) were enrolled in the study. The mean age at the time of surgery was 22.0 ± 6.4 years (range, 14-32 years). All clinical and functional scores significantly improved in the first 2 years ( P < .001), with the mean Kujala, Lysholm, and Tegner scores improving from 52.7 to 90.7, 49.6 to 92.7, and 2.9 to 5.1, respectively. There was no significant difference in scores between 2- and 5-year follow-up. All radiographic parameters significantly improved between preoperatively and immediately postoperatively ( P < .001), with mean values for the modified Insall-Salvati ratio, congruence angle, and lateral patellofemoral angle improving from 1.7° to 1.6°, 5.7° to −6.6°, and 3.0° to 5.9°, respectively. No significant differences were observed in radiographic measurements between the postoperative time points. No patients experienced a patellar redislocation or fracture. Conclusion: The prospective analysis of isolated DB MPFL reconstruction at 5-year follow-up showed that clinical and radiological outcomes significantly improved postoperatively and were maintained to 5 years. These midterm results suggest that isolated DB MPFL reconstruction is an effective treatment option for patients with patellar instability.


  • Open Access

    Identification of plasma and urinary inflammatory markers in severe knee osteoarthritis: Relations with synovial fluid markers

    by Ji-Sun Shin, Hyobeom Lee, Seong Hyeon Kim, Kyu-Cheol Noh, Sung Jae Kim, Hyong Nyun Kim, Jae‑Young Choi, Si Young Song

    Background: This study aimed to identify plasma and urinary cytokines as potential biomarkers for severe knee osteoarthritis (OA). It also investigated associations between these cytokines and cartilage markers, as well as their connections with synovial fluid (SF) markers. Methods: Samples of plasma, urine, and SF were obtained from patients (n = 40) undergoing total knee arthroplasty (TKA) or unicompartmental knee arthroplasty (UKA) due to severe knee OA. Control samples of plasma and urine were collected from non-OA individuals (n = 15). We used a Luminex immunoassay for the simultaneous measurement of 19 cytokines, MMP-1, and MMP-3 levels. COMP, CTX-II, and hyaluronan (HA) levels were quantified using enzyme-linked immunosorbent assay (ELISA) kits. Receiver operating characteristic (ROC) curves were utilized to analyze each biomarker’s performance. Correlations among these biomarkers were evaluated via Spearman’s correlation. Results: The levels of plasma (p)CCL11, pCXCL16, pIL-8, pIL-15, pHA, urinary (u)CCL2, uCCL11, uCCL19, uCXCL16, uIL-1β, uIL-6, uIL-8, uIL-12p70, uIL-15, uIL-33, uMMP-3, uHA, uCTX-II, and uCOMP were significantly elevated in individuals with severe knee OA. Notably, specific correlations were observed between the plasma/urine biomarkers and SF biomarkers: pCCL11 with sfHA (r = 0.56) and sfTNF-α (r = 0.58), pIL-15 with sfCCL19 (r = 0.43) and sfCCL20 (r = 0.44), and uCCL19 with sfCCL11 (r = 0.45) and sfIL-33 (r = 0.51). Positive correlations were also observed between uCCL11 and its corresponding sfCCL11(r = 0.49), as well as between sfCCL11 and other cytokines, namely sfCCL4, sfCCL19, sfCCL20, sfIL-33, and sfTNF-α (r = 0.46–0.63). Conclusion: This study provides an extensive profile of systemic inflammatory mediators in plasma of knee OA and identified four inflammatory markers (pCCL11, pIL-15, uCCL11, and uCCL19) reflecting joint inflammation.


  • Implant Removal After Medial Opening Wedge High Tibial Osteotomy Provides Implant‐Related Pain Relief and Functional Improvement

    by Hyobeom Lee, Ji‐Sun Shin, Sung‐Yup Hong, Young‐Heon Jeon, Young‐Jin Seo, Jeehyoung Kim, Si Young Song

    Purpose: To investigate the incidence of implant‐related pain after medial opening wedge high tibial osteotomy (MOWHTO) using a locking plate, to determine whether implant removal provides pain relief and functional improvement, and to evaluate bone healing and loss of correction after implant removal. Methods: Between March 2014 and September 2017, MOWHTO was performed without bone graft. The inclusion criteria were patients who underwent implant removal after MOWHTO and were followed up for a minimum of 2 years. Patients were evaluated for implant removal 1 and 2 years after surgery. Clinical and functional evaluations were conducted to investigate implant‐related pain using the visual analog scale, Lysholm score, and Tegner score. The radiographic indices measured were the gap‐filling rate, weightbearing line (WBL) ratio, hip‐knee‐ankle angle (HKAA), medial proximal tibial angle (MPTA), and posterior tibial slope angle (PTSA). Results: A total of 55 patients were enrolled. Fifty‐one (92.7%) patients experienced implant‐related pain prior to implant removal, with 43 and 8 patients reporting mild pain and moderate pain, respectively. At 1 and 2 years after implant removal, mild pain occurred in 6 (10.9%) and 5 (9.1%) patients, respectively. The remaining patients reported no implant‐related pain. Prior to implant removal and 1 year after implant removal, the Lysholm score improved from 77.0 ± 5.6 to 86.8 ± 5.7 ( P < .001), and the Tegner score improved from 3.3 ± 1.2 to 3.9 ± 1.3 ( P < .001). The mean gap‐filling rate was 84.4% ± 9.6% at implant removal, and it significantly increased to 93.7% ± 5.4% and 97.4% ± 2.6% at 1 and 2 years after implant removal, respectively ( P < .001). For the WBL ratio, HKAA, MPTA, and PTSA, no statistically significant differences were found after implant removal. Conclusions: The incidence of implant‐related pain after MOWHTO using the medial proximal tibial locking plate was high. Implant removal provides pain relief and functional improvement (met minimal clinically important differences). Even after implant removal, bone healing progressed gradually without a loss of correction in all patients. Level of Evidence: Level IV, case series.


  • Bioessential Inorganic Molecular Wire‐Reinforced 3D‐Printed Hydrogel Scaffold for Enhanced Bone Regeneration

    by Jin Woong Lee, Sudong Chae, Seungbae Oh, Dai‐Hwan Kim, Si Hyun Kim, Seung Jae Kim, Jae‐Young Choi, Jung Heon Lee, Si Young Song

    Materials with physicochemical properties and biological activities similar to those of the natural extracellular matrix are in high demand in tissue engineering. In particular, Mo3Se3− inorganic molecular wire (IMW) is a promising material composed of bioessential minerals and possess nanometer‐scale diameters, negatively charged surfaces, physical flexibility, and nanotopography characteristics, which are essential for interactions with cell membrane proteins. Here, an implantable 3D Mo3Se3− IMW enhanced gelatin‐GMA/silk‐GMA hydrogel (IMW‐GS hydrogel) is developed for osteogenesis and bone formation, followed by biological evaluations. The mechanical properties of the 3D printed IMW‐GS hydrogel are improved by noncovalent interactions between the Mo3Se3− IMWs and the positively charged residues of the gelatin molecules. Long‐term biocompatibility with primary human osteoblast cells (HOBs) is confirmed using the IMW‐GS hydrogel. The proliferation, osteogenic gene expression, collagen accumulation, and mineralization of HOBs improve remarkably with the IMW‐GS hydrogel. In in vivo evaluations, the IMW‐GS hydrogel implantation exhibits a significantly improved new bone regeneration of 87.8 ± 5.9% (p < 0.05) for 8 weeks, which is higher than that from the gelatin‐GMA/silk‐GMA hydrogel without Mo3Se3− IMW. These results support a new improved strategy with in vitro and in vivo performance of 3D IMW enhanced scaffolds in tissue engineering.


  • Open Access

    Effects of modified trans-tibial versus trans-portal technique on stress patterns around the femoral tunnel in anatomical single-bundle ACL reconstruction with different knee flexion angles using finite element analysis

    by Hyun-Soo Moon, Si Young Song, Ji Ung Oh, Young-Jin Seo

    Background: It is unclear whether different anterior cruciate ligament (ACL) graft trajectories in the distal femur would have different effects on stress generated within the distal femur around the femoral tunnel during knee motion. Thus, the purpose of this study was to determine differences in stress patterns around the femoral tunnel created by trans-portal (TP) vs. modified trans-tibial (TT) technique in anatomical ACL reconstruction at different knee flexion angles. Methods: Twelve male subjects’ right knees were scanned with a high-resolution computed tomography (CT) scanner (slice thickness: 1 mm) at four different knee flexion angles (0°, 45°, 90°, and 135°). Three-dimensional (3D) models of these four different flexion angles were created and manipulated with several modelling programs. For the TP group, the virtual femoral tunnelling procedure was performed in a 135° flexion model from the low far anteromedial (AM) portal. For the modified TT group, the same knee models were drilled through the modified TT technique at 90° of flexion separately. Virtual grafts under tension of 40 N were put into corresponding bone tunnel and fixed at the outer aperture of femoral tunnels to simulate the suspensory fixation, followed by fixation of the grafts at the middle of tibial tunnels in the 0° knee flexion models. Finally, the models were exported to a finite element analysis package and analysed using ABAQUS/Explicit code (ABAQUS, USA) to monitor the stress occurring at the node where stress distribution occurred most significantly in the femoral bone around the bone tunnel. Results: In general, both groups showed a high stress distribution in bony structures around inner and outer orifices of the femoral tunnel. Mean maximal stresses occurring at the lateral femoral condyle around the inner orifice of the femoral tunnel in the TP group were found to be significantly greater than those in the modified TT group at all flexion angles except 90° of flexion. Mean maximal stresses monitored around the outer orifice of the femoral tunnel in the TP group were also significantly greater than those in the modified TT group at all flexion angles. Conclusions: Different tunnelling technologies could yield different stress patterns in the lateral femoral condyle around the femoral tunnel. During knee motion, higher stresses were noticed in the TP group than in the modified TT group, especially around inner and outer orifices of the tunnel. Position of the tunnel after reconstruction with the TP technique can have a greater effect on the stress increase in the femur compared to that with the modified TT technique.