HAHeidi Ahkola

Heidi Ahkola

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Heidi Ahkola has a total of 81 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Marine pharmaceutical monitoring with POCIS: sampling rate uncertainty, and implications for regulation

    by Heidi Ahkola, Lauri Äystö, Mailis Laht, Vallo Kõrgmaa, Jukka Mehtonen, Kai Myrberg, Ljudmila Vesikko, Ville Junttila

    POCIS passive samplers were deployed at differently polluted marine sites in the cities of Helsinki and Tallinn and in an open part of the Gulf of Finland. The aim was to determine baseline concentration levels for pharmaceuticals in water monitored with passive sampling techniques, which could also be applied to regulatory monitoring. That baseline concentration data method could then be applied to other sites in the Tallinn and Helsinki area to assess whether the pharmaceutical concentration is elevated or at the baseline level. Altogether, 150 pharmaceuticals were analysed from passive and grab water samples, and 30 substances were discovered. The number of pharmaceuticals detected in passive samplers (27) was higher than in grab samples (20). However, the study revealed the presence of several pharmaceuticals even from expected background sites, such as the open sea site in Gulf of Finland, implying their ubiquitous presence in the study area. The passive sampling results have been converted to TWAC with sampling rate, which is characteristic of the sampler type and studied compound. We assessed the suitability and differences of sampling rates collected from the literature, calculated from LogK OW values and estimated from field deployment results. The selection of sampling rate is essential, as it can cause 86 to 99% differences in determined TWACs. The TWAC was compared with PNEC was calculated to evaluate the potential environmental risk. There are still open questions regarding how to reconcile the passive sampling results with regulatory monitoring obligations based on grab water sampling and existing limit concentrations.

  • Open Access

    Uncertainty in Environmental Micropollutant Modeling

    by Heidi Ahkola, Niina Kotamäki, Eero Siivola, Jussi Tiira, Stefano Imoscopi, Matteo Riva, Ulas Tezel, Janne Juntunen

    Water pollution policies have been enacted across the globe to minimize the environmental risks posed by micropollutants (MPs). For regulative institutions to be able to ensure the realization of environmental objectives, they need information on the environmental fate of MPs. Furthermore, there is an urgent need to further improve environmental decision-making, which heavily relies on scientific data. Use of mathematical and computational modeling in environmental permit processes for water construction activities has increased. Uncertainty of input data considers several steps from sampling and analysis to physico-chemical characteristics of MP. Machine learning (ML) methods are an emerging technique in this field. ML techniques might become more crucial for MP modeling as the amount of data is constantly increasing and the emerging new ML approaches and applications are developed. It seems that both modeling strategies, traditional and ML, use quite similar methods to obtain uncertainties. Process based models cannot consider all known and relevant processes, making the comprehensive estimation of uncertainty challenging. Problems in a comprehensive uncertainty analysis within ML approach are even greater. For both approaches generic and common method seems to be more useful in a practice than those emerging from ab initio. The implementation of the modeling results, including uncertainty and the precautionary principle, should be researched more deeply to achieve a reliable estimation of the effect of an action on the chemical and ecological status of an environment without underestimating or overestimating the risk. The prevailing uncertainties need to be identified and acknowledged and if possible, reduced. This paper provides an overview of different aspects that concern the topic of uncertainty in MP modeling.


  • Open Access

    Monitoring and modelling of butyltin compounds in Finnish inland lake

    by Heidi Ahkola, Janne Juntunen, Kirsti Krogerus, Timo Huttula

    In this study we measured the total concentration of BTCs using grab water sampling, dissolved concentration with passive samplers, and particle-bound fraction with sedimentation traps in a Finnish inland lake. The sampling was conducted from May to September over two study years. In grab water samples the average concentration of MBT at sampling sites varied between 4.8 and 13 ng L−1, DBT 0.9–2.4 ng L−1, and TBT 0.4–0.8 ng L−1 during the first study year and 0.6–1.1 ng L−1, DBT 0.5–2.2 ng L−1 and TBT < LOD-0.7 ng L−1 during the second year. The average BTC concentrations determined with passive samplers varied between 0.08 and 0.53 ng L−1 for MBT, 0.10–0.14 ng L−1 for DBT and 0.05–0.07 ng L−1 for TBT during the first study year and 0.03–0.05 ng L−1 for MBT, 0.02–0.05 ng L−1 for DBT and TBT 0.007–0.013 ng L−1 during the second year. The average BTC concentrations measured in sedimented particles collected with sedimentation traps were between 1.5 and 9.0 ng L−1 for MBT, 0.61–22 ng L−1 for DBT and 0.05–1.8 ng L−1 for TBT during the first study year and 3.0–12 ng L−1 for MBT, 1.7–9.8 ng L−1 for DBT and TBT 0.4–1.2 ng L−1 during the second year. The differences between sampling techniques and the detected BTCs were obvious, e.g., tributyltin (TBT) was detected only in 4%–24% of the grab samples, 50% of the sedimentation traps, and 93% of passive samplers. The BTC concentrations measured with grab and passive sampling suggested hydrological differences between the study years. This was confirmed with flow velocity measurements. However, the annual difference was not observed in BTC concentrations measured in settled particles which suggest that only the dissolved BTC fraction varied. The extreme value analysis suggested that grab sampling and sedimentation trap sampling results contain more extreme peak values than passive sampling. However, all high concentrations are not automatically extreme values but indicates that BTCs are present in surface water in trace concentrations despite not being detected with all sampling techniques.


  • Open Access

    Correction: Effect of the orientation and fluid flow on the accumulation of organotin compounds to Chemcatcher passive samplers

    by H. Ahkola, J. Juntunen, M. Laitinen, K. Krogerus, T. Huttula, S. Herve, A. Witick

    Correction for ‘Effect of the orientation and fluid flow on the accumulation of organotin compounds to Chemcatcher passive samplers’ by H. Ahkola et al., Environ. Sci.: Processes Impacts, 2015, 17, 813–824, https://doi.org/10.1039/C4EM00585F.

  • Open Access

    Monitoring and Modelling of Butyltin Compounds in Finnish Inland Lake

    by Heidi Ahkola, Janne Juntunen, Kirsti Krogerus, Timo Huttula

    Butyltin compounds (BTCs) in surface waters is seldom studied due to their low concentrations and limitations of analytical techniques. In this study we measured total concentration of BTCs with grab water sampling, dissolved concentration with passive samplers and particle bound fraction with sedimentation traps in Finnish inland lake. The sampling was conducted from May to September during two study years. The differences between sampling techniques and the concentrations were obvious. E.g. tributyltin (TBT) was detected only in 4-24 % of the grab samples when the detection with passive samplers was 93% and with sedimentation traps 50%. The dissolved BTC concentrations measured with grab and passive sampling suggested hydrological differences between the study years. This was confirmed with flow velocity measurements. However, the annual difference was not observed in BTC concentrations of settled particle.The extreme value analysis suggested that grab sampling and sedimentation trap sampling results contain more extreme peak values than passive sampling. This indicates that BTCs are present in surface water in trace concentrations despite they are not detected with all the sampling techniques. The assumption that WWTP, located in the study area, was the source of BTCs was not valid as elevated BTC concentrations were detected also at the reference site, located upstream of WWTP. Computational modelling and back tracking simulations also supported the concept that WWTP cannot be the only source but BTCs can come even from upstream of the sampling area where there is e.g. wood processing industry.

  • A preliminary study on the ecotoxic potency of wastewater treatment plant sludge combining passive sampling and bioassays

    by Heidi Ahkola, Petra Lindholm-Lehto, Noora Perkola, Pia Välitalo, Päivi Meriläinen, Kimmo Mäenpää, Julio Alberto Alegre Stelzer, Ilse Heiskanen, Johanna Järvistö, Jari Nuutinen, et al.


  • Pharmaceuticals in processing of municipal sewage sludge studied by grab and passive sampling

    by Petra C. Lindholm-Lehto, Heidi S. J. Ahkola, Juha S. Knuutinen

    Concentrations of pharmaceuticals, consisting of four anti-inflammatory and one antiepileptic drug were studied in the aqueous and solid phase of municipal sewage sludge, collected from a wastewater treatment plant (WWTP) in central Finland. The samples included untreated municipal sludge from the biological wastewater treatment, digested sludge and sludge before and after composting. First, samples were taken as grab samples to study the bioavailable part in aqueous phase but also the part in solid fraction. Later, the long-term concentrations were studied by passive sampling with styrene divinylbenzene-reverse phase sulfonated (SDB-RPS) disks. In the untreated solid sludge, the concentrations of carbamazepine, diclofenac, ibuprofen, ketoprofen, and naproxen were 0.5 ng g−1, 26 ng g−1, 29 ng g−1, 250 ng g−1, and 13 ng g−1, while in liquid phase they were 5.6 ng L−1, 200 ng L−1, 210 ng L−1, 35 ng L−1, and 55 ng L−1, respectively. Concentrations decreased with the treatment steps but substantial amounts still occur even after the final stage. The results show that current sludge treatment cannot fully remove pharmaceuticals, leaving varying concentrations after each stage. Additionally, the results suggest that SDB-RPS disks are suitable for sampling and quantification of the bioavailable fraction of pharmaceuticals in municipal sludge.


  • Presence of active pharmaceutical ingredients in the continuum of surface and ground water used in drinking water production

    by Heidi Ahkola, Sirkku Tuominen, Sanja Karlsson, Noora Perkola, Timo Huttula, Sami Saraperä, Aki Artimo, Taina Korpiharju, Lauri Äystö, Päivi Fjäder, et al.

    Anthropogenic chemicals in surface water and groundwater cause concern especially when the water is used in drinking water production. Due to their continuous release or spill-over at waste water treatment plants, active pharmaceutical ingredients (APIs) are constantly present in aquatic environment and despite their low concentrations, APIs can still cause effects on the organisms. In the present study, Chemcatcher passive sampling was applied in surface water, surface water intake site, and groundwater observation wells to estimate whether the selected APIs are able to end up in drinking water supply through an artificial groundwater recharge system. The API concentrations measured in conventional wastewater, surface water, and groundwater grab samples were assessed with the results obtained with passive samplers. Out of the 25 APIs studied with passive sampling, four were observed in groundwater and 21 in surface water. This suggests that many anthropogenic APIs released to waste water proceed downstream and can be detectable in groundwater recharge. Chemcatcher passive samplers have previously been used in monitoring several harmful chemicals in surface and wastewaters, but the path of chemicals to groundwater has not been studied. This study provides novel information on the suitability of the Chemcatcher passive samplers for detecting APIs in groundwater wells.