Ane Martinez-De-Guerenu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ane Martinez-De-Guerenu has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Berger
CIC nanoGUNE BRTA
6 shared publications - Isabel Gutiérrez
CEIT and Tecnun (University of Navarra)
6 shared publications - Aitor Lasaosa
CEIT-Basque Research and Technology Alliance (BRTA), Donostia / San Sebastián, Spain
5 shared publications F Arizti
CEIT and Tecnun (University of Navarra)
5 shared publicationsF. Arizti
CEIT and Tecnun (University of Navarra) 2 , Manuel de Lardizábal 15, E-20018 Donostia-San Sebastián, Spain
5 shared publicationsFernando Arizti
CEIT and Tecnun (University of Navarra), San Sebastian , SPAIN
5 shared publications
Latest Publications
- Open Access
- 2 May 2025
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 44 (2) , 1-11
Microstructural Analysis of Multi-Phase Coated Hot Stamped Steel Using Magnetic Barkhausen Noise
The microstructure of multi-phase coated hot stamped steel samples is analyzed non-destructively using the magnetic Barkhausen noise (MBN) testing method. The analysis includes examining the microstructural phases in the bulk of hot stamped samples and estimating the thickness of the Al-Si diffusion layer (DL), which exhibits a ferritic microstructure. The MBN of three sets of hot stamped ultra-high strength steel sheets are analyzed. The first set of samples with the same DL is used to study the effect of the microstructural phases of the bulk material and to qualitatively assess the amount of the phases present, while the second and third sets, both with an almost fully martensitic bulk, are used to analyze the capacity of MBN to characterize DL thickness. The results demonstrate that the first peak of the MBN envelope at a very low magnetic field level is due to the superficial ferritic DL, while the peaks at higher levels reflect the microstructural phases of the hot stamped steel. In cases where the ferrite is predominant in the bulk, a peak emerges at medium magnetic field levels, whereas if martensite is the predominant phase, a peak is reached at a higher magnetic field. When both phases are present in significant amounts, both peaks can be observed. Moreover, the amplitude of the first peak derived from the MBN envelope could be used to determine DL thickness. Therefore, an analysis of the MBN envelope signal could provide useful information about the quality of the hot stamping process.
- 2 May 2025
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 44 (2) , 1-11
Open AccessMicrostructural Analysis of Multi-Phase Coated Hot Stamped Steel Using Magnetic Barkhausen Noise
The microstructure of multi-phase coated hot stamped steel samples is analyzed non-destructively using the magnetic Barkhausen noise (MBN) testing method. The analysis includes examining the microstructural phases in the bulk of hot stamped samples and estimating the thickness of the Al-Si diffusion layer (DL), which exhibits a ferritic microstructure. The MBN of three sets of hot stamped ultra-high strength steel sheets are analyzed. The first set of samples with the same DL is used to study the effect of the microstructural phases of the bulk material and to qualitatively assess the amount of the phases present, while the second and third sets, both with an almost fully martensitic bulk, are used to analyze the capacity of MBN to characterize DL thickness. The results demonstrate that the first peak of the MBN envelope at a very low magnetic field level is due to the superficial ferritic DL, while the peaks at higher levels reflect the microstructural phases of the hot stamped steel. In cases where the ferrite is predominant in the bulk, a peak emerges at medium magnetic field levels, whereas if martensite is the predominant phase, a peak is reached at a higher magnetic field. When both phases are present in significant amounts, both peaks can be observed. Moreover, the amplitude of the first peak derived from the MBN envelope could be used to determine DL thickness. Therefore, an analysis of the MBN envelope signal could provide useful information about the quality of the hot stamping process.
- 8 July 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (2)
Layer-resolved vector magnetometry using generalized magneto-optical ellipsometry
We demonstrate the ability of a single magneto-optical reflection experiment to achieve layer-resolved vector magnetometry in multilayer films. For this purpose, we designed, fabricated, and measured a set of epitaxial ferromagnetic/non-magnetic/ferromagnetic heterostructure multilayer samples that exhibit in-plane uniaxial anisotropy and a tunable ferromagnetic interlayer coupling strength through the non-magnetic interlayer. By means of generalized magneto-optical ellipsometry measurements, we obtain the magnetization angles of the two different ferromagnetic layers independently as a function of the applied field. Hereby, we observe that the magnetization switching of one layer can trigger a discontinuous shift of the magnetization angle in the second layer if ferromagnetic interlayer coupling is present. Moreover, we reproduce the obtained behavior using a model of two coupled macrospins, which corroborates even the unexpected aspects of our experimental results and thus reinforces the sensitivity and reliability of our experimental layer-resolved vector magnetometry.
- 8 July 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (2)
Layer-resolved vector magnetometry using generalized magneto-optical ellipsometry
We demonstrate the ability of a single magneto-optical reflection experiment to achieve layer-resolved vector magnetometry in multilayer films. For this purpose, we designed, fabricated, and measured a set of epitaxial ferromagnetic/non-magnetic/ferromagnetic heterostructure multilayer samples that exhibit in-plane uniaxial anisotropy and a tunable ferromagnetic interlayer coupling strength through the non-magnetic interlayer. By means of generalized magneto-optical ellipsometry measurements, we obtain the magnetization angles of the two different ferromagnetic layers independently as a function of the applied field. Hereby, we observe that the magnetization switching of one layer can trigger a discontinuous shift of the magnetization angle in the second layer if ferromagnetic interlayer coupling is present. Moreover, we reproduce the obtained behavior using a model of two coupled macrospins, which corroborates even the unexpected aspects of our experimental results and thus reinforces the sensitivity and reliability of our experimental layer-resolved vector magnetometry.
- Open Access
Grinding Burn Detection via Magnetic Barkhausen Noise Analysis Independently of Induction Hardened Depth
The electromagnetic technique based on magnetic Barkhausen noise (MBN) can be used to control the quality of ball screw shafts non-destructively, although identifying any slight grinding burns independently of induction-hardened depth remains a challenge. The capacity to detect slight grinding burns was studied using a set of ball screw shafts manufactured by means of different induction hardening treatments and different grinding conditions (some of them under abnormal conditions for the purpose of generating grinding burns), and MBN measurements were taken in the whole group of ball screw shafts. Additionally, some of them were tested using two different MBN systems in order to better understand the effect of the slight grinding burns, while Vickers microhardness and nanohardness measurements were taken in selected samples. To detect the grinding burns (both slight anddata intense) with varying depths of the hardened layer, a multiparametric analysis of the MBN signal is proposed using the main parameters of the MBN two-peak envelope. At first, the samples are classified into groups depending on their hardened layer depth, estimated using the intensity of the magnetic field measured on the first peak (H1) parameter, and the threshold functions of two parameters (the minimum amplitude between the peaks of the MBN envelope (MIN) and the amplitude of the second peak (P2)) are then determined to detect the slight grinding burns for the different groups.
Open AccessGrinding Burn Detection via Magnetic Barkhausen Noise Analysis Independently of Induction Hardened Depth
The electromagnetic technique based on magnetic Barkhausen noise (MBN) can be used to control the quality of ball screw shafts non-destructively, although identifying any slight grinding burns independently of induction-hardened depth remains a challenge. The capacity to detect slight grinding burns was studied using a set of ball screw shafts manufactured by means of different induction hardening treatments and different grinding conditions (some of them under abnormal conditions for the purpose of generating grinding burns), and MBN measurements were taken in the whole group of ball screw shafts. Additionally, some of them were tested using two different MBN systems in order to better understand the effect of the slight grinding burns, while Vickers microhardness and nanohardness measurements were taken in selected samples. To detect the grinding burns (both slight anddata intense) with varying depths of the hardened layer, a multiparametric analysis of the MBN signal is proposed using the main parameters of the MBN two-peak envelope. At first, the samples are classified into groups depending on their hardened layer depth, estimated using the intensity of the magnetic field measured on the first peak (H1) parameter, and the threshold functions of two parameters (the minimum amplitude between the peaks of the MBN envelope (MIN) and the amplitude of the second peak (P2)) are then determined to detect the slight grinding burns for the different groups.
- 30 August 2022
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 55 (43) , 435007
Sensitivity and reproducibility of transverse magneto-optical Kerr effect (T-MOKE) ellipsometry
We report a comprehensive experimental study to analyze the limiting factors and physical mechanisms that determine the achievable performance of transverse magneto-optical Kerr effect (T-MOKE) ellipsometry. Specifically, we explore different approaches to achieve high sensitivity and reduced acquisition times. The best sensitivity is observed for an incident light polarization with balanced s-p components. We also verify experimentally that the method’s theoretical description is accurately describing data for any s-p combination of the incoming light. Furthermore, two alternative measurement strategies are explored by using different measurement sequences for the polarization sensitive optics, which both achieve a very comparable, high quality of results. Signal-to-noise ratios and systematic deviations are measured and analyzed based on a large number of nominally identical measurement repeats, both for entire signal sequences as well as for individual Fourier components of the magneto-optical signal generated by a sinusoidal magnetic field sequence. Hereby, we observe that while higher order Fourier components have a significantly reduced signal amplitude and correspondingly exhibit reduced signal-to-noise and repeatability performance, signal-to-noise ratios always exceed values of 100 even for the lowest signal Fourier component and the lowest signal sample that we investigated, illustrating the extremely precise nature of T-MOKE ellipsometry.
- 30 August 2022
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 55 (43) , 435007
Sensitivity and reproducibility of transverse magneto-optical Kerr effect (T-MOKE) ellipsometry
We report a comprehensive experimental study to analyze the limiting factors and physical mechanisms that determine the achievable performance of transverse magneto-optical Kerr effect (T-MOKE) ellipsometry. Specifically, we explore different approaches to achieve high sensitivity and reduced acquisition times. The best sensitivity is observed for an incident light polarization with balanced s-p components. We also verify experimentally that the method’s theoretical description is accurately describing data for any s-p combination of the incoming light. Furthermore, two alternative measurement strategies are explored by using different measurement sequences for the polarization sensitive optics, which both achieve a very comparable, high quality of results. Signal-to-noise ratios and systematic deviations are measured and analyzed based on a large number of nominally identical measurement repeats, both for entire signal sequences as well as for individual Fourier components of the magneto-optical signal generated by a sinusoidal magnetic field sequence. Hereby, we observe that while higher order Fourier components have a significantly reduced signal amplitude and correspondingly exhibit reduced signal-to-noise and repeatability performance, signal-to-noise ratios always exceed values of 100 even for the lowest signal Fourier component and the lowest signal sample that we investigated, illustrating the extremely precise nature of T-MOKE ellipsometry.
- 10 August 2021
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 54 (43) , 435002
Insertion layer magnetism detection and analysis using transverse magneto-optical Kerr effect (T-MOKE) ellipsometry
This experimental study demonstrates that with transverse magneto-optical Kerr effect (T-MOKE) ellipsometry, it is possible to determine the magneto-optical and magnetic properties of insertion layers, even if they are superimposed onto much larger magnetic signals from the surrounding structure. Hereby, it turns out to be especially valuable that with T-MOKE ellipsometry one has full and precise quantitative access to the complex value of the magneto-optical reflection matrix component β ˜ , because small magneto-optical insertion layer signals do not necessarily increase the absolute size of β ˜ , but can lead to observable phase changes of this complex quantity instead. We demonstrate the ability of T-MOKE ellipsometry to precisely detect such small effects and hereby allow for an accurate determination of the alloy concentration dependent onset of ferromagnetism in ultrathin Co x Ru 1− x insertion layers, that are embedded into a much thicker ferromagnetic structure. In addition, a detailed and quantitative signal analysis allowed us to demonstrate that the Co x Ru 1− x insertion layers in our samples exhibit a magnetization reversal behavior that is independent of the adjacent Y 3 Fe 5 O 12 layers, clearly indicating that both magnetic entities are either not or only very weakly coupled.
- 10 August 2021
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 54 (43) , 435002
Insertion layer magnetism detection and analysis using transverse magneto-optical Kerr effect (T-MOKE) ellipsometry
This experimental study demonstrates that with transverse magneto-optical Kerr effect (T-MOKE) ellipsometry, it is possible to determine the magneto-optical and magnetic properties of insertion layers, even if they are superimposed onto much larger magnetic signals from the surrounding structure. Hereby, it turns out to be especially valuable that with T-MOKE ellipsometry one has full and precise quantitative access to the complex value of the magneto-optical reflection matrix component β ˜ , because small magneto-optical insertion layer signals do not necessarily increase the absolute size of β ˜ , but can lead to observable phase changes of this complex quantity instead. We demonstrate the ability of T-MOKE ellipsometry to precisely detect such small effects and hereby allow for an accurate determination of the alloy concentration dependent onset of ferromagnetism in ultrathin Co x Ru 1− x insertion layers, that are embedded into a much thicker ferromagnetic structure. In addition, a detailed and quantitative signal analysis allowed us to demonstrate that the Co x Ru 1− x insertion layers in our samples exhibit a magnetization reversal behavior that is independent of the adjacent Y 3 Fe 5 O 12 layers, clearly indicating that both magnetic entities are either not or only very weakly coupled.
- 30 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
Improvement in the Equivalent Indirect Hysteresis Cycles Obtained From the Distortion of the Voltage Measured in the Excitation Coil
The equivalent indirect hysteresis cycle ( $B_{\mathrm {ec}}$ – $H$ cycle) obtained from the distortion of the voltage measured in the excitation coil facilitates the implementation of magnetic nondestructive characterization systems reducing hardware and error sources, as pick-up coils and their conditioning stages are not necessary. The aim of this article is to propose a sine-fitting (SF) algorithm in order to obtain the $B_{\mathrm {ec}}$ – $H$ cycles for nondestructive testing applications. Although the parameters of $B_{\mathrm {ec}}$ – $H$ cycles are not an accurate measurement of magnetic properties, they are equivalent to those of the indirect hysteresis cycles and thus are sensitive to different material processing variables. The $B_{\mathrm {ec}}$ – $H$ cycles of low carbon, dual phase, and ultrahigh strength steels obtained using SF and synchronous demodulation (SD) algorithms are compared. The parameters of $B_{\mathrm {ec}}$ – $H$ cycles obtained using the SF algorithm evidence greater sensitivity to material processing variables and are linearly correlated with parameters of indirect hysteresis cycles.
- 30 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
Improvement in the Equivalent Indirect Hysteresis Cycles Obtained From the Distortion of the Voltage Measured in the Excitation Coil
The equivalent indirect hysteresis cycle ( $B_{\mathrm {ec}}$ – $H$ cycle) obtained from the distortion of the voltage measured in the excitation coil facilitates the implementation of magnetic nondestructive characterization systems reducing hardware and error sources, as pick-up coils and their conditioning stages are not necessary. The aim of this article is to propose a sine-fitting (SF) algorithm in order to obtain the $B_{\mathrm {ec}}$ – $H$ cycles for nondestructive testing applications. Although the parameters of $B_{\mathrm {ec}}$ – $H$ cycles are not an accurate measurement of magnetic properties, they are equivalent to those of the indirect hysteresis cycles and thus are sensitive to different material processing variables. The $B_{\mathrm {ec}}$ – $H$ cycles of low carbon, dual phase, and ultrahigh strength steels obtained using SF and synchronous demodulation (SD) algorithms are compared. The parameters of $B_{\mathrm {ec}}$ – $H$ cycles obtained using the SF algorithm evidence greater sensitivity to material processing variables and are linearly correlated with parameters of indirect hysteresis cycles.
- 9 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
A New Technique to Obtain an Equivalent Indirect Hysteresis Loop From the Distortion of the Voltage Measured in the Excitation Coil
A new technique to calculate an equivalent indirect hysteresis loop, Bec-H loop, from the distortion of the voltage measured in the magnetic excitation coil is proposed. The aim is to facilitate the industrial implementation of magnetic characterization reducing hardware and error sources of the measuring system, as pick-up coils and their conditioning stages are not necessary. With the Bec-H technique, the characterization of two set of materials with very different properties using a simplified electromagnetic system has been achieved. Specifically, the change in the microstructure of annealed low carbon steel samples was monitored and the hardness of ultra-high steel sheets was characterized. Moreover, the conventional hysteresis cycles and Bec-H loops are compared and the obtained lineal relationships between the parameters derived from conventional hysteresis and Bec-H loops verify that Bec-H loops can provide equivalent parameters for magnetic characterization of steel samples as conventional hysteresis loops.
- 9 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
A New Technique to Obtain an Equivalent Indirect Hysteresis Loop From the Distortion of the Voltage Measured in the Excitation Coil
A new technique to calculate an equivalent indirect hysteresis loop, Bec-H loop, from the distortion of the voltage measured in the magnetic excitation coil is proposed. The aim is to facilitate the industrial implementation of magnetic characterization reducing hardware and error sources of the measuring system, as pick-up coils and their conditioning stages are not necessary. With the Bec-H technique, the characterization of two set of materials with very different properties using a simplified electromagnetic system has been achieved. Specifically, the change in the microstructure of annealed low carbon steel samples was monitored and the hardness of ultra-high steel sheets was characterized. Moreover, the conventional hysteresis cycles and Bec-H loops are compared and the obtained lineal relationships between the parameters derived from conventional hysteresis and Bec-H loops verify that Bec-H loops can provide equivalent parameters for magnetic characterization of steel samples as conventional hysteresis loops.
- 12 March 2020
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 53 (20) , 205001
Ultrasensitive transverse magneto-optical Kerr effect measurements using an effective ellipsometric detection scheme
We present a new methodology that enables a significant sensitivity improvement for transverse magneto-optical Kerr effect (T-MOKE) detection. For this purpose, we developed a novel measurement scheme, in which the polarization detection conditions are changed during the measurement sequence in a pre-defined way. An analytical expression of the associated T-MOKE signal pattern was derived, which allowed us to analyze and classify our experimental data in a straightforward way. Furthermore, this new measurement approach enables the identification of noise and false background signals that might be generated by the sample under investigation, the environment or the detection system itself and it provides a pathway to unambiguously separate all these effects from true T-MOKE signals. These capabilities significantly increase the sensitivity and robustness of T-MOKE detection. The method enabled us to measure magneto-optical signals for samples that are paramagnetic at room temperature or exhibit really small magneto-optical responses, even in the presence of false signals that were far larger in size. Our new methodology was integrated into a scanning wafer tool, which allows for nondestructive, laterally resolved surface characterization measurements and even has the capability of measuring optical and magneto-optical properties simultaneously.
- 12 March 2020
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 53 (20) , 205001
Ultrasensitive transverse magneto-optical Kerr effect measurements using an effective ellipsometric detection scheme
We present a new methodology that enables a significant sensitivity improvement for transverse magneto-optical Kerr effect (T-MOKE) detection. For this purpose, we developed a novel measurement scheme, in which the polarization detection conditions are changed during the measurement sequence in a pre-defined way. An analytical expression of the associated T-MOKE signal pattern was derived, which allowed us to analyze and classify our experimental data in a straightforward way. Furthermore, this new measurement approach enables the identification of noise and false background signals that might be generated by the sample under investigation, the environment or the detection system itself and it provides a pathway to unambiguously separate all these effects from true T-MOKE signals. These capabilities significantly increase the sensitivity and robustness of T-MOKE detection. The method enabled us to measure magneto-optical signals for samples that are paramagnetic at room temperature or exhibit really small magneto-optical responses, even in the presence of false signals that were far larger in size. Our new methodology was integrated into a scanning wafer tool, which allows for nondestructive, laterally resolved surface characterization measurements and even has the capability of measuring optical and magneto-optical properties simultaneously.
- Open Access
- 1 November 2018
- Published by Elsevier in Physica B: Condensed Matter
- Vol. 549, 122-126
Use of meta-modelling for identification and interpolation of parametric hysteresis models applied to the characterization of carbon steels
- 1 November 2018
- Published by Elsevier in Physica B: Condensed Matter
- Vol. 549, 122-126
Open AccessUse of meta-modelling for identification and interpolation of parametric hysteresis models applied to the characterization of carbon steels