Rajendra Kotadiya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rajendra Kotadiya has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Ajay Patel
Amneal Pharmaceuticals Private Limited
2 shared publicationsHimani Acharya
Ramanbhai Patel College of Pharmacy Charotar University of Science and Technology Anand Gujarat India
2 shared publications- Jagdish Gohel
Ramanbhai Patel College of Pharmacy, Charotar University of Science and Technology, Changa
2 shared publications Janvi Shah
Department of Pharmaceutical Quality Assurance, Ramanbhai Patel College of Pharmacy, Charotar University of Science and Technology , CHARUSAT Campus, Changa , Dist-Anand, Gujarat 388421, India
2 shared publications- Rashmin Bharat Patel
Ramanbhai Patel College of Pharmacy Charotar University of Science and Technology (CHARUSAT) Changa India
2 shared publications Bhavin Bhalani
1 shared publication
Latest Publications
- 6 April 2026
- Published by Taylor & Francis in Drug Development and Industrial Pharmacy
- Vol. 52 (6) , 1169-1185
AQbD-based UHPLC approach for quantification of everolimus residues in cleaning validation processes
Everolimus (EVR) is a potent antineoplastic agent classified as a mammalian rapamycin (mTOR) kinase inhibitor target [1]. Its ability to effectively suppress cancer cell proliferation makes it a va...
- 6 April 2026
- Published by Taylor & Francis in Drug Development and Industrial Pharmacy
- Vol. 52 (6) , 1169-1185
AQbD-based UHPLC approach for quantification of everolimus residues in cleaning validation processes
Everolimus (EVR) is a potent antineoplastic agent classified as a mammalian rapamycin (mTOR) kinase inhibitor target [1]. Its ability to effectively suppress cancer cell proliferation makes it a va...
- Open Access
- 24 October 2025
- Published by Springer Nature in BMC Chemistry
- Vol. 19 (1) , 1-13
Green UHPLC approach for the quantitative determination of tiopronin residues in cleaning validation processes
This study presents the development and validation of a novel reverse-phase ultra-high-performance liquid chromatography (UHPLC) method for quantifying tiopronin residues on manufacturing equipment surfaces as part of cleaning validation. Tiopronin, a synthetic thiol compound with therapeutic applications, requires stringent manufacturing controls to ensure product safety and efficacy. Existing analytical techniques mainly focus on quantifying tiopronin in pharmaceutical formulations or biological matrices. However, no methods specifically address cleaning validation for tiopronin production equipment. Using an Analytical Quality by Design approach, this UHPLC method was optimized and validated by ICH Q2 (R2) guidelines. The technique employs a Waters ACQUITY UPLC H-Class PLUS C-18 column (100 mm × 2.1 mm, 1.7 µm) with a mobile phase of 88:12 (v/v) 0.1% v/v orthophosphoric acid (pH 2.1) and acetonitrile, achieving a tiopronin retention time of 1.3 min. The method demonstrated specificity, precision, accuracy, and linearity over a concentration range of 0.302 to 3.027 µg/mL. The limit of detection and quantification were 0.100 µg/mL and 0.301 µg/mL, respectively. The greenness of the method was assessed using AGREE, GAPI, and RGB 12 tools. The scores obtained were 0.67 for AGREE, 85.0 for BAGI, and 82.1 for RGB 12 suggesting proposed method is environment friendly. This novel method provides an efficient, eco-friendly solution for routine cleaning validation, addressing a significant gap in existing analytical techniques for tiopronin manufacturing.
- 24 October 2025
- Published by Springer Nature in BMC Chemistry
- Vol. 19 (1) , 1-13
Open AccessGreen UHPLC approach for the quantitative determination of tiopronin residues in cleaning validation processes
This study presents the development and validation of a novel reverse-phase ultra-high-performance liquid chromatography (UHPLC) method for quantifying tiopronin residues on manufacturing equipment surfaces as part of cleaning validation. Tiopronin, a synthetic thiol compound with therapeutic applications, requires stringent manufacturing controls to ensure product safety and efficacy. Existing analytical techniques mainly focus on quantifying tiopronin in pharmaceutical formulations or biological matrices. However, no methods specifically address cleaning validation for tiopronin production equipment. Using an Analytical Quality by Design approach, this UHPLC method was optimized and validated by ICH Q2 (R2) guidelines. The technique employs a Waters ACQUITY UPLC H-Class PLUS C-18 column (100 mm × 2.1 mm, 1.7 µm) with a mobile phase of 88:12 (v/v) 0.1% v/v orthophosphoric acid (pH 2.1) and acetonitrile, achieving a tiopronin retention time of 1.3 min. The method demonstrated specificity, precision, accuracy, and linearity over a concentration range of 0.302 to 3.027 µg/mL. The limit of detection and quantification were 0.100 µg/mL and 0.301 µg/mL, respectively. The greenness of the method was assessed using AGREE, GAPI, and RGB 12 tools. The scores obtained were 0.67 for AGREE, 85.0 for BAGI, and 82.1 for RGB 12 suggesting proposed method is environment friendly. This novel method provides an efficient, eco-friendly solution for routine cleaning validation, addressing a significant gap in existing analytical techniques for tiopronin manufacturing.
- Open Access
- 31 August 2025
- Published by Springer Nature in BMC Chemistry
- Vol. 19 (1) , 1-11
A novel RP-HPLC approach for simultaneous determination of dapagliflozin, linagliptin, and metformin in pharmaceutical formulations
A simple, precise, and stability-indicating reverse-phase high-performance liquid chromatography method was developed and validated for the simultaneous estimation of dapagliflozin, linagliptin, and metformin hydrochloride in fixed-dose combination tablets. Chromatographic separation was achieved using a Phenomenex Luna C18 column (250 × 4.6 mm, 5 μm) with a mobile phase consisting of acetonitrile and phosphate buffer (pH 6.8) in a 40:60 v/v ratio; the buffer was modified to the mentioned pH with triethylamine and orthophosphoric acid. The flow rate was maintained at 0.8 mL/min, with detection at 230 nm. The method demonstrated excellent linearity within the ranges of 20–140 µg/mL for metformin hydrochloride, 0.2–1.4 µg/mL for linagliptin, and 0.6–2.8 µg/mL for dapagliflozin, with correlation coefficients (R²) > 0.995. The validation was performed as per ICH Q2 (R2) guidelines, confirming the method’s accuracy, precision (%RSD < 2%), robustness, specificity, and sensitivity. Forced degradation studies under acidic, basic, oxidative, thermal, and photolytic conditions confirmed the method’s capability to resolve each analyte from its degradation products, affirming its stability-indicating nature. Application of the method to a commercial formulation yielded assay values of 101.41%, 100.04%, and 99.73% w/w for metformin hydrochloride, linagliptin, and dapagliflozin, respectively. These results validate the method’s applicability for routine quality control and stability testing of multi-drug antidiabetic formulations.
- 31 August 2025
- Published by Springer Nature in BMC Chemistry
- Vol. 19 (1) , 1-11
Open AccessA novel RP-HPLC approach for simultaneous determination of dapagliflozin, linagliptin, and metformin in pharmaceutical formulations
A simple, precise, and stability-indicating reverse-phase high-performance liquid chromatography method was developed and validated for the simultaneous estimation of dapagliflozin, linagliptin, and metformin hydrochloride in fixed-dose combination tablets. Chromatographic separation was achieved using a Phenomenex Luna C18 column (250 × 4.6 mm, 5 μm) with a mobile phase consisting of acetonitrile and phosphate buffer (pH 6.8) in a 40:60 v/v ratio; the buffer was modified to the mentioned pH with triethylamine and orthophosphoric acid. The flow rate was maintained at 0.8 mL/min, with detection at 230 nm. The method demonstrated excellent linearity within the ranges of 20–140 µg/mL for metformin hydrochloride, 0.2–1.4 µg/mL for linagliptin, and 0.6–2.8 µg/mL for dapagliflozin, with correlation coefficients (R²) > 0.995. The validation was performed as per ICH Q2 (R2) guidelines, confirming the method’s accuracy, precision (%RSD < 2%), robustness, specificity, and sensitivity. Forced degradation studies under acidic, basic, oxidative, thermal, and photolytic conditions confirmed the method’s capability to resolve each analyte from its degradation products, affirming its stability-indicating nature. Application of the method to a commercial formulation yielded assay values of 101.41%, 100.04%, and 99.73% w/w for metformin hydrochloride, linagliptin, and dapagliflozin, respectively. These results validate the method’s applicability for routine quality control and stability testing of multi-drug antidiabetic formulations.
- 17 January 2025
- Published by Wiley in Separation Science Plus
- Vol. 8 (1)
Analytical Technique Advances for Recently Approved Fixed‐Dose Combination of Dapagliflozin and Teneligliptin Hydrobromide Hydrate
Most people with diabetes mellitus type 2 require more than one antihyperglycemic medication to achieve glycemic control. Products comprising one or more active components are utilized for certain indications. Several benefits, including impending therapeutic efficacy, fewer adverse drug effects, pharmacokinetic advantages, and a reduction in the dose of individual medications, justify their acceptance. To treat type 2 diabetic mellitus, a fixed‐dose tablet containing Teneligliptin (20 mg) and Dapagliflozin (DAPA) (10 or 5 mg) has recently been approved for phase III clinical trials. This review gathered and summarized the information on the stated analytical methods and physicochemical and biological characteristics of the fixed‐dose tablet formulations. The writers reviewed several credible scientific journals to achieve their goals and offered streamlined material. The published methods for Teneligliptin and DAPA include spectroscopy (42.8% and 20.7%), high performance thin layer chromatography (HPTLC) (11.4% and 9.4%), high performance liquid chromatography (37.1% and 47.1%), and hyphenated techniques (8.5% and 22.6%). The recently authorized fixed‐dose formulation would benefit from the analysts' use of such comprehensive data in their analytical methodology.
- 17 January 2025
- Published by Wiley in Separation Science Plus
- Vol. 8 (1)
Analytical Technique Advances for Recently Approved Fixed‐Dose Combination of Dapagliflozin and Teneligliptin Hydrobromide Hydrate
Most people with diabetes mellitus type 2 require more than one antihyperglycemic medication to achieve glycemic control. Products comprising one or more active components are utilized for certain indications. Several benefits, including impending therapeutic efficacy, fewer adverse drug effects, pharmacokinetic advantages, and a reduction in the dose of individual medications, justify their acceptance. To treat type 2 diabetic mellitus, a fixed‐dose tablet containing Teneligliptin (20 mg) and Dapagliflozin (DAPA) (10 or 5 mg) has recently been approved for phase III clinical trials. This review gathered and summarized the information on the stated analytical methods and physicochemical and biological characteristics of the fixed‐dose tablet formulations. The writers reviewed several credible scientific journals to achieve their goals and offered streamlined material. The published methods for Teneligliptin and DAPA include spectroscopy (42.8% and 20.7%), high performance thin layer chromatography (HPTLC) (11.4% and 9.4%), high performance liquid chromatography (37.1% and 47.1%), and hyphenated techniques (8.5% and 22.6%). The recently authorized fixed‐dose formulation would benefit from the analysts' use of such comprehensive data in their analytical methodology.
- 16 December 2024
- Published by Wiley in Separation Science Plus
- Vol. 8 (1)
A Comprehensive Review of Analytical Methods on Everolimus: A Basis for Cleaning Residue Quantitation
The development and validation of analytical methods for assessing cleaning residues are essential for pharmaceutical manufacturing, particularly to meet the maximum allowable carryover limits through precise detection and quantification of residues. This review explores various analytical techniques for quantifying Everolimus residues, including spectrophotometric, chromatographic hyphenated, and advanced miscellaneous methods, each evaluated for sensitivity, specificity, and applicability. The hyphenated techniques, accounting for 65% of reported methods, are favored for their superior trace‐level sensitivity, while chromatographic methods (25%) are valued for robustness and precision. By providing a comparative analysis of each technique's strengths and limitations, this review serves as a practical guide for selecting the most appropriate analytical approach to cleaning validation. The insights offered support the establishment of acceptance criteria, guide sampling method selection, and contribute to optimizing cleaning processes, ultimately helping manufacturers ensure regulatory compliance and reduce cross‐contamination risks. This review thus acts as a foundational resource for improving cleaning validation practices and aligning analytical method selection with industry standards to safeguard product integrity and patient safety.
- 16 December 2024
- Published by Wiley in Separation Science Plus
- Vol. 8 (1)
A Comprehensive Review of Analytical Methods on Everolimus: A Basis for Cleaning Residue Quantitation
The development and validation of analytical methods for assessing cleaning residues are essential for pharmaceutical manufacturing, particularly to meet the maximum allowable carryover limits through precise detection and quantification of residues. This review explores various analytical techniques for quantifying Everolimus residues, including spectrophotometric, chromatographic hyphenated, and advanced miscellaneous methods, each evaluated for sensitivity, specificity, and applicability. The hyphenated techniques, accounting for 65% of reported methods, are favored for their superior trace‐level sensitivity, while chromatographic methods (25%) are valued for robustness and precision. By providing a comparative analysis of each technique's strengths and limitations, this review serves as a practical guide for selecting the most appropriate analytical approach to cleaning validation. The insights offered support the establishment of acceptance criteria, guide sampling method selection, and contribute to optimizing cleaning processes, ultimately helping manufacturers ensure regulatory compliance and reduce cross‐contamination risks. This review thus acts as a foundational resource for improving cleaning validation practices and aligning analytical method selection with industry standards to safeguard product integrity and patient safety.
- Open Access
- 14 October 2024
- Published by Taylor & Francis in Journal of Taibah University for Science
- Vol. 18 (1)
AQbD-guided stability indicating HPLC method for azelnidipine and chlorthalidone fixed-dose combination tablet: a green approach
- 14 October 2024
- Published by Taylor & Francis in Journal of Taibah University for Science
- Vol. 18 (1)
Open AccessAQbD-guided stability indicating HPLC method for azelnidipine and chlorthalidone fixed-dose combination tablet: a green approach
- 2 August 2024
- Published by Taylor & Francis in Drug Development and Industrial Pharmacy
- Vol. 50 (8) , 750-762
Stability-indicating green HPLC method for fixed-dose tablets containing remogliflozin etabonate and teneligliptin: an AQbD approach
In June 2021, the Central Drug Standards Control Organization approved a fixed-dose combination tablet containing remogliflozin etabonate (100 mg) and teneligliptin (10 mg) to manage type II diabetes. This study aims to develop a stability-indicating RP-HPLC method for quantifying remogliflozin etabonate and teneligliptin in tablet formulations via analytical quality by design (AQbD) principles. Risk assessment, Plackett-Burman design, and central composite design were employed to understand the impact of independent variables on critical analytical attributes. The stationary phase was a HyperClone BDS C18 column, and the mobile phase consisted of acetonitrile and phosphate buffer (20 mM, pH 5) at a 45:55% (v/v) ratio. The method, validated per ICH Q2 (R1), resulted in retention times of 3.395 and 12.308 minutes for teneligliptin and remogliflozin etabonate, respectively. Forced degradation studies confirmed robustness, with clear peak separation and no interference from degradation products. The AGREE score of 0.65 supports its green applicability for tablet analysis in quality control. The AQbD-assisted RP-HPLC method developed in this study offers environmental friendliness, efficient separation with well-defined peaks, and simple mobile phase combination.
- 2 August 2024
- Published by Taylor & Francis in Drug Development and Industrial Pharmacy
- Vol. 50 (8) , 750-762
Stability-indicating green HPLC method for fixed-dose tablets containing remogliflozin etabonate and teneligliptin: an AQbD approach
In June 2021, the Central Drug Standards Control Organization approved a fixed-dose combination tablet containing remogliflozin etabonate (100 mg) and teneligliptin (10 mg) to manage type II diabetes. This study aims to develop a stability-indicating RP-HPLC method for quantifying remogliflozin etabonate and teneligliptin in tablet formulations via analytical quality by design (AQbD) principles. Risk assessment, Plackett-Burman design, and central composite design were employed to understand the impact of independent variables on critical analytical attributes. The stationary phase was a HyperClone BDS C18 column, and the mobile phase consisted of acetonitrile and phosphate buffer (20 mM, pH 5) at a 45:55% (v/v) ratio. The method, validated per ICH Q2 (R1), resulted in retention times of 3.395 and 12.308 minutes for teneligliptin and remogliflozin etabonate, respectively. Forced degradation studies confirmed robustness, with clear peak separation and no interference from degradation products. The AGREE score of 0.65 supports its green applicability for tablet analysis in quality control. The AQbD-assisted RP-HPLC method developed in this study offers environmental friendliness, efficient separation with well-defined peaks, and simple mobile phase combination.
- 28 June 2024
- Published by Elsevier in Annales Pharmaceutiques Françaises
- Vol. 82 (6) , 1071-1081
Stability-indicating HPLC for remogliflozin, vildagliptin, and metformin: Method development, validation, and greenness
- 28 June 2024
- Published by Elsevier in Annales Pharmaceutiques Françaises
- Vol. 82 (6) , 1071-1081
Stability-indicating HPLC for remogliflozin, vildagliptin, and metformin: Method development, validation, and greenness
- 15 March 2024
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 62 (8) , 742-750
Development and Validation of a New Reversed Phase HPLC Method for the Quantitation of Azithromycin and Rifampicin in a Capsule Formulation
This research aimed to develop a new method for simultaneously estimating the presence of azithromycin (AZT) and rifampicin (RIF) in a capsule formulation using reverse-phase high-performance liquid chromatography. The developed method utilized a Gemini column with a 60:40% v/v acetonitrile and potassium dihydrogen phosphate mobile phase, a flow rate of 1 mL/min, and an injection volume of 20 μL. The detection wavelengths of 210 and 254 nm for AZT and RIF, respectively, were used. Validation ensures specificity with a peak purity index > 0.99999 for AZT and >0.99995 for RIF, affirming unambiguous analyte detection. The system suitability test, within acceptable limits, validates method reliability. Linearity calibration curves (R2 = 0.998) cover a 25–150% target concentration range. Accuracy studies employing the standard addition method yield recovery values between 96.6 and 103.9% for both drugs, confirming method accuracy. Precision studies reveal % relative standard deviation values consistently below 2%, highlighting reproducibility. Robustness testing supports method reliability under varying conditions. Application to a pharmaceutical capsule formulation demonstrates the method’s practicality, accurately quantifying AZT (98.30%) and RIF (99.37%). This study provides a validated analytical approach for simultaneous quantification in commercial pharmaceutical products containing both drugs, enhancing pharmaceutical quality control for critical antibiotics in complex formulations.
- 15 March 2024
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 62 (8) , 742-750
Development and Validation of a New Reversed Phase HPLC Method for the Quantitation of Azithromycin and Rifampicin in a Capsule Formulation
This research aimed to develop a new method for simultaneously estimating the presence of azithromycin (AZT) and rifampicin (RIF) in a capsule formulation using reverse-phase high-performance liquid chromatography. The developed method utilized a Gemini column with a 60:40% v/v acetonitrile and potassium dihydrogen phosphate mobile phase, a flow rate of 1 mL/min, and an injection volume of 20 μL. The detection wavelengths of 210 and 254 nm for AZT and RIF, respectively, were used. Validation ensures specificity with a peak purity index > 0.99999 for AZT and >0.99995 for RIF, affirming unambiguous analyte detection. The system suitability test, within acceptable limits, validates method reliability. Linearity calibration curves (R2 = 0.998) cover a 25–150% target concentration range. Accuracy studies employing the standard addition method yield recovery values between 96.6 and 103.9% for both drugs, confirming method accuracy. Precision studies reveal % relative standard deviation values consistently below 2%, highlighting reproducibility. Robustness testing supports method reliability under varying conditions. Application to a pharmaceutical capsule formulation demonstrates the method’s practicality, accurately quantifying AZT (98.30%) and RIF (99.37%). This study provides a validated analytical approach for simultaneous quantification in commercial pharmaceutical products containing both drugs, enhancing pharmaceutical quality control for critical antibiotics in complex formulations.