Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yulong Song has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comprehensive Performance and Economic Analyses of Transcritical CO2 Heat Pump Water Heater Suitable for Petroleum Processes and Heating Applications

    by Dongxue Zhu, Chaohe Fang, Shejiao Wang, Yafei Xue, Liaoliang Jiang, Yulong Song, Feng Cao

    With the intensification of the global energy crisis, the application of air-source transcritical CO2 heat pumps has attracted increasing attention, especially in cold regions. Existing research mainly focuses on the evaluation of steady-state performance while paying less attention to the dynamic characteristics of the system during the actual operation process. In order to deeply study the dynamic performance of the air-source transcritical CO2 heat pump system under the winter climate conditions in the Yan‘an area, this study established a system simulation model with multiple parameter inputs and systematically analyzed the influences of ambient temperature, discharge pressure, and inlet and outlet water temperatures on the heating capacity and COP. The research starts from both dynamic and steady-state perspectives, revealing the variation law of system performance with environmental temperature and conducting a quantitative analysis. As the ambient temperature rose from −11 °C to 2 °C, the COP of the system increased by approximately 15% and exhibited significant dynamic response characteristics, indicating that the increase in ambient temperature significantly improved system efficiency. At different ambient temperatures, the optimal discharge pressure increased with the rise in temperature. At the highest ambient temperature (2 °C), the optimal discharge pressure was 11.7 MPa. Compared with the optimal discharge pressure of 11.0 MPa at −11 °C, the performance improved by nearly 13.3%. Through the dynamic simulation method, theoretical support is provided for the optimization of energy-saving control strategies in cold regions, and thoughts are offered regarding the application of transcritical CO2 systems under similar climatic conditions.


  • Open Access

    A Comprehensive Assessment of the Refrigerant Charging Amount on the Global Performance of a Transcritical CO2-Based Bus Air Conditioning and Heat Pump System

    by Yulong Song, Hongsheng Xie, Mengying Yang, Xiangyu Wei, Feng Cao, Xiang Yin

    To mitigate the contemporary environmental challenges and to respect the regulations on the progressive ban of hydrofluorocarbons (HFC), natural fluid CO2 was selected as an ideal refrigerant alternative in the transportation domain. In this study, the optimal CO2 charging amount and the refrigerant distribution in a bus air conditioning/heat pump system were analyzed in detail. The results showed that there was a plateau (so named by the best charging amount) of the CO2 charging amount in which the system performance reached an optimal value and maintained it nearly unchanged during this plateau while the performance declined on both sides of the plateau. In addition, the ambient temperature was found to have little effect on the determination of the refrigerant charging plateau, while the refrigerant distribution was affected by the ambient temperature to some extent. Due to the large thermal load and thermal inertia on a bus, the data and conclusions obtained are different from those of ordinary electric small passenger vehicles. This article aims to discover some quantitative parameters and lay a theoretical foundation in this field which is lacking relevant research. Through the research based on the GT-Suite simulation platform, we simulated the transcritical CO2 cycle applied on a bus, and the performance changes of the bus system (COP 1.2–2.2, refrigerating capacity 9.5–18 kW) under different charging rates (3–8 kg) were obtained.


  • Open Access

    The Collaborative Optimization of the Discharge Pressure and Heat Recovery Rate in a Transcritical CO2 Heat Pump Used in Extremely Low Temperature Environment

    by Zhongkai Wu, Feifei Bi, Jiyou Fei, Zecan Zheng, Yulong Song, Feng Cao

    Considering the excellent environmental properties and heating capability under wide running conditions of the natural fluid CO2, the transcritical CO2 heat pump system has widely been used in the application of water heaters, commercial heating and cooling, electric vehicle thermal management, etc. Since the performance was highly affected by the discharge pressure and heat recovery rate in a transcritical CO2 system, the collaborative optimization of these two parameters was analyzed in detail in this study. The results showed that the optimal value of the system heating COP, which was the ration of heating capacity to power consumption, was better under a higher heat recovery rate and relatively lower discharge pressure, which is why these kinds of operating conditions are highly recommended from the perspective of collaborative optimization. Additionally, the heat recovery rate had a positive effect on the system performance when the discharge pressure was lower than its optimal value, while the heat recovery rate would present a passive effect on the system performance when the discharge pressure was higher than its optimal value. The relevant conclusions of this study provide a good theoretical basis for the efficient and stable operation of the transcritical CO2 heat pump technology under the conditions of a wide ambient temperature range.


  • Open Access

    The Experimental Study of an R744 Heat Pump System for an Electric Vehicle for Cabin Cooling or Heating and Battery Fast Charging Cooling

    by Xilong Wang, Keke Xu, Linjie Huang, Feng Cao, Yulong Song

    In this paper, a new R744 heat pump system is studied. The gas cooler, evaporator, indoor heat core, and indoor gas cooler are all micro-channel heat exchangers. The R744 high pressure system adopts a combination of an accumulator and internal heat exchanger (ACCU/IHX). In addition, an electronic reversible regulating valve is added before the outdoor gas cooler, making the outdoor heat exchanger able to be used as a gas cooler or evaporator. The water-cooled condenser can improve the performance in the cooling or heating mode. The research contents contain the performance and optimal pressure under extreme conditions as a result of the experiments. The results show that the cooling capacity can reach 8.2 kW with a COP of 1.87, under a 40 °C external circulation intake. The cooling capacity on the battery side can reach 11 kW under an ambient temperature of 40 °C, which can provide a sufficient cooling capacity. Under an ambient temperature of −20 °C, the maximum heating capacity can reach 6.86 kW with a COP of 1.67. Under an ambient temperature of −15 °C, the heating capacity reaches 5.07 kW with a COP of 1.78, when the indoor air volume flow rate is 200 m3/h. Obviously, R744 heat pumps show a huge advantage, compared with the traditional PTC heating or R134a heat pumps at extremely low temperatures.


  • Open Access

    Energy and Exergy Analysis of the Air Source Transcritical CO2 Heat Pump Water Heater Using CO2-Based Mixture as Working Fluid

    by Yikai Wang, Yifan He, Yulong Song, Xiang Yin, Feng Cao, Xiaolin Wang

    Given the large demand nowadays for domestic hot water, and its impact on modern building energy consumption, air source transcritical CO2 heat pumps have been extensively adopted for hot water production. Since their system efficiency is limited by significant irreversibility, a CO2-based mixture could offer a promising drop-in technology to overcome this deficiency without increasing system complexity. Although many CO2 blends have been studied in previously published literature, little has been presented about the CO2/R32 mixture. Therefore, a proposed mixture for use in transcritical CO2 heat pumps was analyzed using energy and exergy analysis. Results showed that the coefficient of performance and exergy efficiency variation displayed an “M” shape trend, and the optimal CO2/R32 mixture concentration was determined as 0.9/0.1 with regard to flammability and efficiency. The irreversibility of the throttling valve was reduced from 0.031 to 0.009 kW⋅kW−1 and the total irreversibility reduction was more notable with ambient temperature variation. A case study was also conducted to examine domestic hot water demand during the year. Pure CO2 and the proposed CO2 blend were compared with regard to annual performance factor and annual exergy efficiency, and the findings could provide guidance for practical applications in the future.


  • Open Access

    Experimental Thermodynamic Investigation on the Refrigerant Charge in a Transcritical CO2 Electric Bus Air Conditioning System

    by Haidan Wang, Shengbo Li, Yulong Song, Xiang Yin, Feng Cao, Paride Gullo

    Due to its considerable impact on climate, bus air conditioning systems are being pushed to take a new and sustainable path. Electric buses relying on transcritical CO2 air conditioning units are perceived to be eco-friendly and future-proof solutions to achieving such a target. However, in order to have highly efficient air conditioning systems, the CO2 charge needs to be optimized. In this paper the energy and exergy-based analyses were performed to investigate the effect of normalized refrigerant charge on the system performance by using a test rig of a transcritical CO2 air conditioning unit for an 8 m electric bus. Results showed that the normalized refrigerant charge range of 0.248~0.336 was recommended in order to ensure the maximum coefficient of performance (COP). In addition, in sufficient charge conditions, the optimal COP, cooling capacity and exergy efficiency were 1.716, 18.97 kW and 29.79%, respectively, under the standard refrigeration condition of 35 °C/27 °C. As the ambient temperature rose from 35 °C to 40 °C, the COP, cooling capacity and exergy efficiency decreased by 16.03%, 10.90% and 12.22%, respectively. Furthermore, the exergy efficiency was found not to be sensitive to slightly insufficient charge, whereas overcharge was observed to be even beneficial to exergy efficiency under the condition of ensuring the maximum COP. In addition, insufficient refrigerant charging seriously affected the irreversible losses in the indoor and outdoor heat exchangers, whereas slight overcharge had little effect on the component exergy efficiency. Finally, the need to improve the CO2 compressor efficiency to enhance the system performance was revealed.


  • Open Access

    Coupling Effect of Air Flow Rate and Operating Conditions on the Performance of Electric Vehicle R744 Air Conditioning System

    by Anci Wang, Jianmin Fang, Xiang Yin, Yulong Song, Feng Cao, Paride Gullo

    The air flow rate on the gas cooler side is one of the key parameters affecting the performance and running safety of transcritical CO2 electric vehicle air conditioning systems. After experimentally analyzing the effects of the air volume flow rate in the gas cooler on the cycle parameters and system performance, a novel method to evaluate the optimal air flow rate was proposed. In addition, the effect of the gas cooler air volume flow rate on the key performance parameters of the system (e.g., optimal discharge pressure) was explored. Finally, the coupling effects of the compressor speed, ambient temperature and optimal air flow rate on the system performance was also exhaustively assessed. It was found that as the discharge temperature, the CO2 temperature at the gas cooler outlet and the discharge pressure did not vary more than ±2%, the corresponding gas cooler air volume flow rate was optimal. For the single-row and dual-process microchannel evaporator used in this work, the recommended value of the optimal gas cooler air volume flow rate was 2500 m3·h−1. The results could provide reference for the fan speed design of electric vehicle CO2 air conditioning systems, especially for the performance under idling model.


  • Open Access

    Investigation of the Impact Factors on the Optimal Intermediate Temperature in a Dual Transcritical CO2 System with a Dedicated Transcritical CO2 Subcooler

    by Yulong Song, Haidan Wang, Feng Cao

    As a natural fluid with superior environment advantages, CO2 is used to constitute a dual transcritical system to reduce performance deterioration under high gas-cooler outlet temperature. Aiming at the system configuration, improvement potential, and optimization, the proposed system is deeply analyzed, and corresponding coupling models are presented in detail. First, the veracity of simulation models is completely verified by comparing with previous measurements. Then, the existence of the optimal intermediate temperature is validated, while the optimal values are found to increase with the augmentation in ambient and water-feed temperatures. Moreover, the negative effects of the pinch point on the heat transfer inside the gas cooler could be greatly reduced by using the dual gas cooler. Finally, a predictive correlation for optimal intermediate temperature determination with ambient and water-feed temperature as independent variables is proposed, which provides a theoretical basis for the proposed system to realize efficient control in the industrialization process.