David Csonka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David Csonka has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Andras Burian
University of Pécs, Medical School, Department of Otorhinolaryngology, Pécs, Hungary
2 shared publicationsArnold Toth
University of Pecs, Medical School, Department of Radiology, Pecs, Hungary
2 shared publicationsBalint Kaszas
University of Pécs, Medical School, Department of Pathology, Pécs, Hungary
2 shared publications- Eva Orosz
University of Pécs, Medical School, Department of Otorhinolaryngology, Pécs, Hungary.
2 shared publications - Géza Várady
Autonomous Technologies and Drones Research Team, Faculty of Engineering and Information Technology, University of Pécs, 7624 Pécs, Hungary
2 shared publications Imre Gerlinger
University of Pécs, Medical School, Department of Otorhinolaryngology, Pécs, Hungary
2 shared publications
Latest Publications
- Open Access
Surrogate Modelling and Simulation Approaches for Renal Artery Haemodynamics: Balancing Symmetry in Computational Cost and Accuracy
Finite element analysis (FEA)-based computational fluid dynamics (CFD) simulations are essential in biomedical engineering for studying haemodynamics, yet their high computational cost limits large-scale parametric studies. This paper presents a comparative analysis of FEA and surrogate modelling techniques applied to renal artery haemodynamics. The aortic–renal bifurcation strongly influences renal perfusion, affecting conditions such as hypertension, infarction, and transplant rejection. This study evaluates GPU-accelerated voxel simulations (Ansys 2024 R2 Discovery), 2D and 3D FEA simulations (COMSOL Multiphysics 6.3), finite volume CFD (Ansys 2020 R2 Fluent), and deep neural networks (DNNs) as surrogate models. Branching angles and blood pressure were systematically varied, and their effects on velocity, pressure, and turbulent kinetic energy were assessed in a time-dependent framework. Fluent provided accurate baseline results, while COMSOL 2D gave sufficient accuracy with much lower runtimes. In contrast, COMSOL 3D required over 160 times longer, making it prohibitive. Surrogate models trained on 6500 or more FEA-derived samples achieved high predictive accuracy (R2 > 0.98 for velocity and pressure), balancing training cost and result quality. Cost analysis showed surrogate models become advantageous after 76–93 simulations. Symmetry is expressed in balancing model fidelity and computational efficiency, providing a resource-effective methodology with broad potential in vascular applications.
Open AccessSurrogate Modelling and Simulation Approaches for Renal Artery Haemodynamics: Balancing Symmetry in Computational Cost and Accuracy
Finite element analysis (FEA)-based computational fluid dynamics (CFD) simulations are essential in biomedical engineering for studying haemodynamics, yet their high computational cost limits large-scale parametric studies. This paper presents a comparative analysis of FEA and surrogate modelling techniques applied to renal artery haemodynamics. The aortic–renal bifurcation strongly influences renal perfusion, affecting conditions such as hypertension, infarction, and transplant rejection. This study evaluates GPU-accelerated voxel simulations (Ansys 2024 R2 Discovery), 2D and 3D FEA simulations (COMSOL Multiphysics 6.3), finite volume CFD (Ansys 2020 R2 Fluent), and deep neural networks (DNNs) as surrogate models. Branching angles and blood pressure were systematically varied, and their effects on velocity, pressure, and turbulent kinetic energy were assessed in a time-dependent framework. Fluent provided accurate baseline results, while COMSOL 2D gave sufficient accuracy with much lower runtimes. In contrast, COMSOL 3D required over 160 times longer, making it prohibitive. Surrogate models trained on 6500 or more FEA-derived samples achieved high predictive accuracy (R2 > 0.98 for velocity and pressure), balancing training cost and result quality. Cost analysis showed surrogate models become advantageous after 76–93 simulations. Symmetry is expressed in balancing model fidelity and computational efficiency, providing a resource-effective methodology with broad potential in vascular applications.
- Open Access
Assessment of Tube–Fin Contact Materials in Heat Exchangers: Guidelines for Simulation and Experiments
This paper describes experiments on finned tube heat exchangers, focusing on reducing the thermal contact resistance at the contact between the pipe and the lamella. Various contact materials, such as solders and adhesives, were investigated. Several methods of establishing contact were tested, including blowtorch soldering, brazing, and furnace soldering. Thermal camera measurements were carried out to assess the performance of the contact materials. Moreover, finite element analysis was performed to evaluate the contact materials and establish guidelines in the fin–tube connection modeling by comparing simplified models with the realistic model. Blowtorch brazing tests were successful while soldering attempts failed. During the thermographic measurements, reflective surfaces could be measured after applying a thin layer of paint with high emissivity. These measurements did not provide valuable results; thus, the contact materials were assessed using a finite element analysis. The results from the finite element analysis showed that all the inspected contact materials provided better heat transfer than not using a contact material. The heat transfer rate of the tight-fit realistic model was found to be 33.65 for air and 34.9 for the Zn-22Al contact material. This finding could be utilized in developing heat exchangers with higher heat transfer with the same size.
Open AccessAssessment of Tube–Fin Contact Materials in Heat Exchangers: Guidelines for Simulation and Experiments
This paper describes experiments on finned tube heat exchangers, focusing on reducing the thermal contact resistance at the contact between the pipe and the lamella. Various contact materials, such as solders and adhesives, were investigated. Several methods of establishing contact were tested, including blowtorch soldering, brazing, and furnace soldering. Thermal camera measurements were carried out to assess the performance of the contact materials. Moreover, finite element analysis was performed to evaluate the contact materials and establish guidelines in the fin–tube connection modeling by comparing simplified models with the realistic model. Blowtorch brazing tests were successful while soldering attempts failed. During the thermographic measurements, reflective surfaces could be measured after applying a thin layer of paint with high emissivity. These measurements did not provide valuable results; thus, the contact materials were assessed using a finite element analysis. The results from the finite element analysis showed that all the inspected contact materials provided better heat transfer than not using a contact material. The heat transfer rate of the tight-fit realistic model was found to be 33.65 for air and 34.9 for the Zn-22Al contact material. This finding could be utilized in developing heat exchangers with higher heat transfer with the same size.
- Open Access
- 20 March 2023
- Published by S. Karger AG in Kidney and Blood Pressure Research
- Vol. 48 (1) , 249-259
Optimal Renal Artery-Aorta Angulation Revealed by Flow Simulation
Introduction: In the circulatory system, the vessel branching angle may have hemodynamic consequences. We hypothesized that there is a hemodynamically optimal range for the renal artery’s branching angle. Methods: Data on the posttransplant kinetics of estimated glomerular filtration rate (eGFR) were analyzed according to the donor and implant sides (right-to-right and left-to-right position; n = 46). The renal artery branching angle from the aorta of a randomly selected population was measured using an X-ray angiogram (n = 44). Computational fluid dynamics simulation was used to elucidate the hemodynamic effects of angulation. Results and Discussion: Renal transplant patients receiving a right donor kidney to the right side showed faster adaptation and higher eGFR values than those receiving a left donor kidney to the right side (eGFR: 65 ± 7 vs. 56 ± 6 mL/min/1.73 m2; p < 0.01). The average branching angle on the left side was 78° and that on the right side was 66°. Simulation results showed that the pressure, volume flow, and velocity were relatively constant between 58° and 88°, indicating that this range is optimal for the kidneys. The turbulent kinetic energy does not change significantly between 58° and 78°. Conclusion: The results suggest that there is an optimal range for the renal artery’s branching angle from the aorta where hemodynamic vulnerability caused by the degree of angulation is the lowest, which should be considered during kidney transplantations.
- 20 March 2023
- Published by S. Karger AG in Kidney and Blood Pressure Research
- Vol. 48 (1) , 249-259
Open AccessOptimal Renal Artery-Aorta Angulation Revealed by Flow Simulation
Introduction: In the circulatory system, the vessel branching angle may have hemodynamic consequences. We hypothesized that there is a hemodynamically optimal range for the renal artery’s branching angle. Methods: Data on the posttransplant kinetics of estimated glomerular filtration rate (eGFR) were analyzed according to the donor and implant sides (right-to-right and left-to-right position; n = 46). The renal artery branching angle from the aorta of a randomly selected population was measured using an X-ray angiogram (n = 44). Computational fluid dynamics simulation was used to elucidate the hemodynamic effects of angulation. Results and Discussion: Renal transplant patients receiving a right donor kidney to the right side showed faster adaptation and higher eGFR values than those receiving a left donor kidney to the right side (eGFR: 65 ± 7 vs. 56 ± 6 mL/min/1.73 m2; p < 0.01). The average branching angle on the left side was 78° and that on the right side was 66°. Simulation results showed that the pressure, volume flow, and velocity were relatively constant between 58° and 88°, indicating that this range is optimal for the kidneys. The turbulent kinetic energy does not change significantly between 58° and 78°. Conclusion: The results suggest that there is an optimal range for the renal artery’s branching angle from the aorta where hemodynamic vulnerability caused by the degree of angulation is the lowest, which should be considered during kidney transplantations.
- Open Access
- 24 March 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1
Author Correction: Visualization of mucosal field in HPV positive and negative oropharyngeal squamous cell carcinomas: combined genomic and radiology based 3D model
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
- 24 March 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1
Open AccessAuthor Correction: Visualization of mucosal field in HPV positive and negative oropharyngeal squamous cell carcinomas: combined genomic and radiology based 3D model
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
- Open Access
- 8 January 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Visualization of mucosal field in HPV positive and negative oropharyngeal squamous cell carcinomas: combined genomic and radiology based 3D model
The aim of this study was to visualize the tumor propagation and surrounding mucosal field in radiography-based 3D model for advanced stage HNSCC and combine it with HPV genotyping and miRNA expression characterization of the visualized area. 25 patients with T1-3 clinical stage HNSCC were enrolled in mapping biopsy sampling. Biopsy samples were evaluated for HPV positivity and miR-21-5p, miR-143, miR-155, miR-221-5p expression in Digital Droplet PCR system. Significant miRNA expression differences of HPV positive tumor tissue biopsies were found for miR-21-5p, miR-143 and miR-221-5p compared to the HPV negative tumor biopsy series. Peritumoral mucosa showed patchy pattern alterations of miR-21-5p and miR-155 in HPV positive cases, while gradual change of miR-21-5p and miR-221-5p was seen in HPV negative tumors. In our study we found differences of the miRNA expression patterns among the HPV positive and negative tumorous tissues as well as the surrounding mucosal fields. The CT based 3D models of the cancer field and surrounding mucosal surface can be utilized to improve proper preoperative planning. Complex evaluation of HNSCC tissue organization field can elucidate the clinical and molecular differentiation of HPV positive and negative cases, and enhance effective organ saving therapeutic strategies.
- 8 January 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Open AccessVisualization of mucosal field in HPV positive and negative oropharyngeal squamous cell carcinomas: combined genomic and radiology based 3D model
The aim of this study was to visualize the tumor propagation and surrounding mucosal field in radiography-based 3D model for advanced stage HNSCC and combine it with HPV genotyping and miRNA expression characterization of the visualized area. 25 patients with T1-3 clinical stage HNSCC were enrolled in mapping biopsy sampling. Biopsy samples were evaluated for HPV positivity and miR-21-5p, miR-143, miR-155, miR-221-5p expression in Digital Droplet PCR system. Significant miRNA expression differences of HPV positive tumor tissue biopsies were found for miR-21-5p, miR-143 and miR-221-5p compared to the HPV negative tumor biopsy series. Peritumoral mucosa showed patchy pattern alterations of miR-21-5p and miR-155 in HPV positive cases, while gradual change of miR-21-5p and miR-221-5p was seen in HPV negative tumors. In our study we found differences of the miRNA expression patterns among the HPV positive and negative tumorous tissues as well as the surrounding mucosal fields. The CT based 3D models of the cancer field and surrounding mucosal surface can be utilized to improve proper preoperative planning. Complex evaluation of HNSCC tissue organization field can elucidate the clinical and molecular differentiation of HPV positive and negative cases, and enhance effective organ saving therapeutic strategies.