Richard M. van Hees
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Richard M. van Hees has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Tim Anton van Kempen
SRON Netherlands Institute for Space Research Niels Bohrweg 4 2333 CA Leiden The Netherlands
23 shared publications Ilse Aben
SRON Netherlands Institute for Space Research, Niels Bohrweg 4, 2333 CA Leiden, The Netherlands
14 shared publicationsRuud Hoogeveen
SRON Netherlands Institute for Space Research, Niels Bohrweg 4, 2333 CA Leiden, The Netherlands
7 shared publicationsRuud W. M. Hoogeveen
SRON Netherlands Institute for Space Research, Sorbonnelaan 2, 3584 CA, Utrecht, The Netherlands
7 shared publications- Carol Bruegge
Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA, USA
6 shared publications - Dejian Fu
Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California, 91109, USA
6 shared publications
Latest Publications
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
TANGO The Twin Anthropogenic Greenhouse Gas Observers Mission
The Twin Anthropogenic Greenhouse Gas Observers (TANGO) mission is a small satellite mission to be launched in 2028, under the ESA Scout Programme tapping into NewSpace to quickly deliver affordable and innovative science, as part of ESA’s FutureEO Programme a schedule of three years from mission kick-off to launch. Designed to complement the Copernicus atmospheric monitoring missions Sentinel-5 Precursor, Sentinel‑4/5, and the CO2M carbon dioxide monitoring mission, TANGO will observe carbon dioxide and methane emissions from human activities to support verification of the Paris Agreement. The mission is anticipated to generate >10,000 emission estimates per year for major industrial facilities and power plants. The scientific community will be able to propose specific observation targets, which will be incorporated into mission planning alongside routine observations aimed at enhancing current state-of-the-art point-source emission inventories. Two agile CubeSat-class satellite buses, each carrying an imaging spectrometer, will operate in close formation with a temporal separation of less than 1 minute, enabling near-sequential observations of the same target area. Platform agility is ensured by three-axis stabilized reaction wheel control, which permits flexible spectrometer pointing with a roll capability of ±30° and forward motion compensation. This forward motion compensation increases the effective integration time by up to a factor of five, thereby enhancing spatial coverage and improving the precision of the retrieved geophysical quantities. As part of the mission implementation, a dedicated ground segment will be established to provide the scientific user community with open and freely accessible data products. These will include calibrated top-of-atmosphere radiance measurements (Level-1b), column-averaged dry air mole fractions of CO2 (XCO2) and CH4 (XCH4), as well as tropospheric NO2 column densities (Level-2), and corresponding emission estimates for CO2, CH4, and NO2 (Level-4). TANGO’s first satellite, TANGO-Carbon, will measure solar-reflected radiances in the 1.6 µm spectral region with a spectral resolution of 0.45 nm, enabling the detection of moderate to strong CH4 emissions (≥ 5 kt yr⁻¹) and CO2 emissions (≥ 2.5 Mt yr⁻¹). The TANGO-Nitro instrument will provide collocated NO2 observations derived from radiance measurements in the visible spectral range with a spectral resolution ≤ 0.6 nm, facilitating plume detection and the use of the CO2/NO2 ratio for improved source characterization and emission quantification. In this contribution, we describe the status of the TANGO mission, the planned data products, the associated scientific opportunities, and the mechanisms for engagement of the scientific community in data exploitation.
- 14 March 2026
- Published by Copernicus GmbH
Open AccessTANGO The Twin Anthropogenic Greenhouse Gas Observers Mission
The Twin Anthropogenic Greenhouse Gas Observers (TANGO) mission is a small satellite mission to be launched in 2028, under the ESA Scout Programme tapping into NewSpace to quickly deliver affordable and innovative science, as part of ESA’s FutureEO Programme a schedule of three years from mission kick-off to launch. Designed to complement the Copernicus atmospheric monitoring missions Sentinel-5 Precursor, Sentinel‑4/5, and the CO2M carbon dioxide monitoring mission, TANGO will observe carbon dioxide and methane emissions from human activities to support verification of the Paris Agreement. The mission is anticipated to generate >10,000 emission estimates per year for major industrial facilities and power plants. The scientific community will be able to propose specific observation targets, which will be incorporated into mission planning alongside routine observations aimed at enhancing current state-of-the-art point-source emission inventories. Two agile CubeSat-class satellite buses, each carrying an imaging spectrometer, will operate in close formation with a temporal separation of less than 1 minute, enabling near-sequential observations of the same target area. Platform agility is ensured by three-axis stabilized reaction wheel control, which permits flexible spectrometer pointing with a roll capability of ±30° and forward motion compensation. This forward motion compensation increases the effective integration time by up to a factor of five, thereby enhancing spatial coverage and improving the precision of the retrieved geophysical quantities. As part of the mission implementation, a dedicated ground segment will be established to provide the scientific user community with open and freely accessible data products. These will include calibrated top-of-atmosphere radiance measurements (Level-1b), column-averaged dry air mole fractions of CO2 (XCO2) and CH4 (XCH4), as well as tropospheric NO2 column densities (Level-2), and corresponding emission estimates for CO2, CH4, and NO2 (Level-4). TANGO’s first satellite, TANGO-Carbon, will measure solar-reflected radiances in the 1.6 µm spectral region with a spectral resolution of 0.45 nm, enabling the detection of moderate to strong CH4 emissions (≥ 5 kt yr⁻¹) and CO2 emissions (≥ 2.5 Mt yr⁻¹). The TANGO-Nitro instrument will provide collocated NO2 observations derived from radiance measurements in the visible spectral range with a spectral resolution ≤ 0.6 nm, facilitating plume detection and the use of the CO2/NO2 ratio for improved source characterization and emission quantification. In this contribution, we describe the status of the TANGO mission, the planned data products, the associated scientific opportunities, and the mechanisms for engagement of the scientific community in data exploitation.
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
Tango mission NO2 End-to-end simulator
Tango consists of two CubeSat platforms, Tango-Carbon and Tango-Nitro, flying in formation.NO2, while not a greenhouse gas itself, can serve as a constraint on CO2 emissions, because both NO2 and CO2 are frequently co-emitted from similar combustion processes. Due to the low atmospheric background concentration of NO2 better detection of CO2 emission plumes is possible.Analysis of NO2 levels provides additional information about the magnitude of CO2 emissions.Detector requirements of the Nitro and Carbon instruments are analyzed using The Tango End-to-end simulator. It consists of a suite of modules that address all aspects of the mission data flow.In this contribution we will describe the NO2 branch of the simulator.
- 14 March 2026
- Published by Copernicus GmbH
Open AccessTango mission NO2 End-to-end simulator
Tango consists of two CubeSat platforms, Tango-Carbon and Tango-Nitro, flying in formation.NO2, while not a greenhouse gas itself, can serve as a constraint on CO2 emissions, because both NO2 and CO2 are frequently co-emitted from similar combustion processes. Due to the low atmospheric background concentration of NO2 better detection of CO2 emission plumes is possible.Analysis of NO2 levels provides additional information about the magnitude of CO2 emissions.Detector requirements of the Nitro and Carbon instruments are analyzed using The Tango End-to-end simulator. It consists of a suite of modules that address all aspects of the mission data flow.In this contribution we will describe the NO2 branch of the simulator.
- Top Cited PapersOpen Access
- 17 February 2025
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 52 (4)
Aerosol Retrievals From SPEXone on the NASA PACE Mission: First Results and Validation
We present the first Spectropolarimeter for Planetary EXploration ‐ one (SPEXone) aerosol retrieval results over land and ocean using the Remote sensing of Trace gas and Aerosol Products algorithm, covering the period 23 February–31 August 2024. We validate the retrieved Aerosol Optical Depth (AOD), Angstrom Exponent (AE), and Single Scattering Albedo (SSA) with AErosol RObotic NETwork (AERONET) data. The validation results show that SPEXone provides products of good quality, with comparable performance over land and ocean. For AOD, the Root‐Mean‐Square Error (RMSE) is 0.053 over land and 0.043 over ocean, while respectively 77% and 75% of the retrievals are within the requirement formulated by the Global Climate Observing System (GCOS). For AE, the RMSE is 0.25 over land and 0.26 over ocean. For SSA, the RMSE is 0.036 over land and 0.036 over ocean, with respectively 69% and 69.4% within the GCOS requirement. After a gap of more than 10 years, this is the first new global Multi‐Angle Polarimeter aerosol dataset.
- 17 February 2025
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 52 (4)
Top Cited PapersOpen AccessAerosol Retrievals From SPEXone on the NASA PACE Mission: First Results and Validation
We present the first Spectropolarimeter for Planetary EXploration ‐ one (SPEXone) aerosol retrieval results over land and ocean using the Remote sensing of Trace gas and Aerosol Products algorithm, covering the period 23 February–31 August 2024. We validate the retrieved Aerosol Optical Depth (AOD), Angstrom Exponent (AE), and Single Scattering Albedo (SSA) with AErosol RObotic NETwork (AERONET) data. The validation results show that SPEXone provides products of good quality, with comparable performance over land and ocean. For AOD, the Root‐Mean‐Square Error (RMSE) is 0.053 over land and 0.043 over ocean, while respectively 77% and 75% of the retrievals are within the requirement formulated by the Global Climate Observing System (GCOS). For AE, the RMSE is 0.25 over land and 0.26 over ocean. For SSA, the RMSE is 0.036 over land and 0.036 over ocean, with respectively 69% and 69.4% within the GCOS requirement. After a gap of more than 10 years, this is the first new global Multi‐Angle Polarimeter aerosol dataset.
- Open Access
- 4 October 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (12) , 125805
In-flight pixel degradation of the Sentinel 5 Precursor TROPOMI-SWIR HgCdTe detector
The TROPOMI-SWIR HgCdTe detector on the Sentinel-5 Precursor mission has been performing in-orbit measurements of molecular absorption in Earth’s atmosphere since its launch in October 2017. In its polar orbit the detector is continuously exposed to potentially harmful energetic particles. Calibration measurements taken during the eclipse are used to inspect the performance of this detector. This paper explores the in-orbit degradation of the HgCdTe detector. After five years, the detector is still performing within specifications, even though pixels are continuously hit by cosmic radiation. The bulk of the impacts have no lasting effects, and most of the damaged pixels (95%) appear to recover on the order of a few days to several months, attributed to a slow spontaneous recovery of defects in the HgCdTe detector material. This is observed at the operational temperature of 140 K. The distribution of the observed recovery times has a mean around nine days with a significant tail towards several months. Pixels that have degraded have a significant probability to degrade again. The location of faulty pixels follows a Poissonian distribution across the detector. No new clusters have appeared, revealing that impacts are dominated by relatively low energetic protons and electrons. Due to the observed spontaneous recovery of pixels, the fraction of pixels meeting all quality requirements in the nominal operations phase has always been over 98.7%. The observed performance of the TROPOMI-SWIR detector in-flight impacts selection criteria of HgCdTe detectors for future space instrumentation.
- 4 October 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (12) , 125805
Open AccessIn-flight pixel degradation of the Sentinel 5 Precursor TROPOMI-SWIR HgCdTe detector
The TROPOMI-SWIR HgCdTe detector on the Sentinel-5 Precursor mission has been performing in-orbit measurements of molecular absorption in Earth’s atmosphere since its launch in October 2017. In its polar orbit the detector is continuously exposed to potentially harmful energetic particles. Calibration measurements taken during the eclipse are used to inspect the performance of this detector. This paper explores the in-orbit degradation of the HgCdTe detector. After five years, the detector is still performing within specifications, even though pixels are continuously hit by cosmic radiation. The bulk of the impacts have no lasting effects, and most of the damaged pixels (95%) appear to recover on the order of a few days to several months, attributed to a slow spontaneous recovery of defects in the HgCdTe detector material. This is observed at the operational temperature of 140 K. The distribution of the observed recovery times has a mean around nine days with a significant tail towards several months. Pixels that have degraded have a significant probability to degrade again. The location of faulty pixels follows a Poissonian distribution across the detector. No new clusters have appeared, revealing that impacts are dominated by relatively low energetic protons and electrons. Due to the observed spontaneous recovery of pixels, the fraction of pixels meeting all quality requirements in the nominal operations phase has always been over 98.7%. The observed performance of the TROPOMI-SWIR detector in-flight impacts selection criteria of HgCdTe detectors for future space instrumentation.
- Open Access
In-flight pixel degradation of the Sentinel 5 Precursor TROPOMI-SWIR HgCdTe detector
The TROPOMI-SWIR HgCdTe detector on the Sentinel-5 Precursor mission has been performing in-orbit measurements of molecular absorption in Earth's atmosphere since its launch in October 2017. In its polar orbit the detector is continuously exposed to potentially harmful energetic particles. Calibration measurements taken during the eclipse are used to inspect the performance of this detector. This paper explores the in-orbit degradation of the HgCdTe detector. After five years, the detector is still performing within specifications, even though pixels are continuously hit by cosmic radiation. The bulk of the impacts have no lasting effects, and most of the damaged pixels (95%) appear to recover on the order of a few days to several months, attributed to a slow spontaneous recovery of defects in the HgCdTe detector material. This is observed at the operational temperature of 140 K. The distribution of the observed recovery times has a mean around nine days with a significant tail towards several months. Pixels that have degraded have a significant probability to degrade again. The location of faulty pixels follows a Poissonian distribution across the detector. No new clusters have appeared, revealing that impacts are dominated by relatively low energetic protons and electrons. Due to the observed spontaneous recovery of pixels, the fraction of pixels meeting all quality requirements in the nominal operations phase has always been over 98.7%. The observed performance of the TROPOMI-SWIR detector in-flight impacts selection criteria of HgCdTe detectors for future space instrumentation.
Open AccessIn-flight pixel degradation of the Sentinel 5 Precursor TROPOMI-SWIR HgCdTe detector
The TROPOMI-SWIR HgCdTe detector on the Sentinel-5 Precursor mission has been performing in-orbit measurements of molecular absorption in Earth's atmosphere since its launch in October 2017. In its polar orbit the detector is continuously exposed to potentially harmful energetic particles. Calibration measurements taken during the eclipse are used to inspect the performance of this detector. This paper explores the in-orbit degradation of the HgCdTe detector. After five years, the detector is still performing within specifications, even though pixels are continuously hit by cosmic radiation. The bulk of the impacts have no lasting effects, and most of the damaged pixels (95%) appear to recover on the order of a few days to several months, attributed to a slow spontaneous recovery of defects in the HgCdTe detector material. This is observed at the operational temperature of 140 K. The distribution of the observed recovery times has a mean around nine days with a significant tail towards several months. Pixels that have degraded have a significant probability to degrade again. The location of faulty pixels follows a Poissonian distribution across the detector. No new clusters have appeared, revealing that impacts are dominated by relatively low energetic protons and electrons. Due to the observed spontaneous recovery of pixels, the fraction of pixels meeting all quality requirements in the nominal operations phase has always been over 98.7%. The observed performance of the TROPOMI-SWIR detector in-flight impacts selection criteria of HgCdTe detectors for future space instrumentation.
- Open Access
- 11 October 2023
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 16 (19) , 4507-4527
Vicarious calibration of the Tropospheric Monitoring Instrument (TROPOMI) short-wave infrared (SWIR) module over the Railroad Valley Playa
The short-wave infrared (SWIR) module of the Tropospheric Monitoring Instrument (TROPOMI) on board the ESA's Sentinel-5 precursor (S5p) satellite has been very stable during its 5 years in orbit. Calibration was performed on the ground, complemented by measurements during in-flight instrument commissioning. The radiometric response and general performance of the SWIR module are monitored by on-board calibration sources. We show that after 5 years in orbit, TROPOMI-SWIR has continued to show excellent performance with degradation of at most 0.1 % in transmission and having lost less than 0.3 % of the detector pixels. Independent validation of the instrument calibration, via vicarious calibration, can be done through comparisons with ground-based reflectance data. In this work, ground measurements at the Railroad Valley Playa, a valley in central Nevada that is often used as a reference for satellite measurements, are used to perform vicarious calibration of the TROPOMI-SWIR measurements. This is done using dedicated measurement campaigns as well as automated reflectance measurements within the RADCALNET programme. As such, TROPOMI-SWIR is an excellent test case to explore the methodology of vicarious calibration applied to infrared spectroscopy. Using methodology developed for the vicarious calibration of the OCO-2 and GOSAT missions, the absolute radiometry of TROPOMI-SWIR performance is independently verified to be stable down to ∼ 6 %–10 % using the Railroad Valley when both the absolute and relative radiometric calibrations are applied. Differences with the on-board calibration originate from the bidirectional reflection distribution function (BRDF) effects of the desert surface, the large variety in viewing angles, and the different sizes of footprints of the TROPOMI pixels. Vicarious calibration is shown to be an additional valuable tool in validating radiance-level performances of infrared instruments such as TROPOMI-SWIR in the field of atmospheric composition. It remains clear that for instruments of similar design and resolution to TROPOMI-SWIR, on-board calibration sources will continue to provide superior results due to the limitations of the vicarious calibration method.
- 11 October 2023
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 16 (19) , 4507-4527
Open AccessVicarious calibration of the Tropospheric Monitoring Instrument (TROPOMI) short-wave infrared (SWIR) module over the Railroad Valley Playa
The short-wave infrared (SWIR) module of the Tropospheric Monitoring Instrument (TROPOMI) on board the ESA's Sentinel-5 precursor (S5p) satellite has been very stable during its 5 years in orbit. Calibration was performed on the ground, complemented by measurements during in-flight instrument commissioning. The radiometric response and general performance of the SWIR module are monitored by on-board calibration sources. We show that after 5 years in orbit, TROPOMI-SWIR has continued to show excellent performance with degradation of at most 0.1 % in transmission and having lost less than 0.3 % of the detector pixels. Independent validation of the instrument calibration, via vicarious calibration, can be done through comparisons with ground-based reflectance data. In this work, ground measurements at the Railroad Valley Playa, a valley in central Nevada that is often used as a reference for satellite measurements, are used to perform vicarious calibration of the TROPOMI-SWIR measurements. This is done using dedicated measurement campaigns as well as automated reflectance measurements within the RADCALNET programme. As such, TROPOMI-SWIR is an excellent test case to explore the methodology of vicarious calibration applied to infrared spectroscopy. Using methodology developed for the vicarious calibration of the OCO-2 and GOSAT missions, the absolute radiometry of TROPOMI-SWIR performance is independently verified to be stable down to ∼ 6 %–10 % using the Railroad Valley when both the absolute and relative radiometric calibrations are applied. Differences with the on-board calibration originate from the bidirectional reflection distribution function (BRDF) effects of the desert surface, the large variety in viewing angles, and the different sizes of footprints of the TROPOMI pixels. Vicarious calibration is shown to be an additional valuable tool in validating radiance-level performances of infrared instruments such as TROPOMI-SWIR in the field of atmospheric composition. It remains clear that for instruments of similar design and resolution to TROPOMI-SWIR, on-board calibration sources will continue to provide superior results due to the limitations of the vicarious calibration method.
- Open Access
- 16 June 2023
- Published by Copernicus GmbH
- Vol. 2023, 1-32
Reply on RC1
The SWIR module of the TROPOMI instrument on board ESA's Sentinel-5p mission has been very stable during its five years in orbit. Calibration was performed on-ground, complemented by measurements during inflight instrument commissioning. The radiometric response and general performance of the SWIR module are monitored by onboard calibration sources. We show that after five years in orbit, TROPOMI-SWIR has continued to show excellent performance with degradation of at most 0.1 % in transmission and having lost less than 0.3 % of the detector pixels. Independent validation of the instrument calibration, via vicarious calibration, can be done through comparisons with ground-based reflectance data. In this work, measurements at the Railroad Valley Playa are used to perform vicarious calibration of the TROPOMI-SWIR measurements, using both dedicated measurement campaigns, as well as automated reflectance measurements through RADCALNET. As such, TROPOMI-SWIR is an excellent test case to explore the methodology of vicarious calibration applied to infrared spectroscopy. Using methodology developed for the vicarious calibration of the OCO-2 and GOSAT missions, the absolute radiometry of TROPOMI-SWIR performance is independently verified to be stable down to ~ 6–10 % using the Railroad Valley, both on the absolute and, thus, relative radiometric calibration. Differences with the onboard calibration originate from the BRDF effects of the desert surface, the large variety in viewing angles, and the different sizes of footprints of the TROPOMI pixels. However, vicarious calibration is shown to be an additional valuable tool in validating radiance-level performances of infra-red instruments such as TROPOMI-SWIR in the field of atmospheric composition.
- 16 June 2023
- Published by Copernicus GmbH
- Vol. 2023, 1-32
Open AccessReply on RC1
The SWIR module of the TROPOMI instrument on board ESA's Sentinel-5p mission has been very stable during its five years in orbit. Calibration was performed on-ground, complemented by measurements during inflight instrument commissioning. The radiometric response and general performance of the SWIR module are monitored by onboard calibration sources. We show that after five years in orbit, TROPOMI-SWIR has continued to show excellent performance with degradation of at most 0.1 % in transmission and having lost less than 0.3 % of the detector pixels. Independent validation of the instrument calibration, via vicarious calibration, can be done through comparisons with ground-based reflectance data. In this work, measurements at the Railroad Valley Playa are used to perform vicarious calibration of the TROPOMI-SWIR measurements, using both dedicated measurement campaigns, as well as automated reflectance measurements through RADCALNET. As such, TROPOMI-SWIR is an excellent test case to explore the methodology of vicarious calibration applied to infrared spectroscopy. Using methodology developed for the vicarious calibration of the OCO-2 and GOSAT missions, the absolute radiometry of TROPOMI-SWIR performance is independently verified to be stable down to ~ 6–10 % using the Railroad Valley, both on the absolute and, thus, relative radiometric calibration. Differences with the onboard calibration originate from the BRDF effects of the desert surface, the large variety in viewing angles, and the different sizes of footprints of the TROPOMI pixels. However, vicarious calibration is shown to be an additional valuable tool in validating radiance-level performances of infra-red instruments such as TROPOMI-SWIR in the field of atmospheric composition.
- Open Access
- 16 June 2023
- Published by Copernicus GmbH
- Vol. 2023, 1-32
Reply on RC2
The SWIR module of the TROPOMI instrument on board ESA's Sentinel-5p mission has been very stable during its five years in orbit. Calibration was performed on-ground, complemented by measurements during inflight instrument commissioning. The radiometric response and general performance of the SWIR module are monitored by onboard calibration sources. We show that after five years in orbit, TROPOMI-SWIR has continued to show excellent performance with degradation of at most 0.1 % in transmission and having lost less than 0.3 % of the detector pixels. Independent validation of the instrument calibration, via vicarious calibration, can be done through comparisons with ground-based reflectance data. In this work, measurements at the Railroad Valley Playa are used to perform vicarious calibration of the TROPOMI-SWIR measurements, using both dedicated measurement campaigns, as well as automated reflectance measurements through RADCALNET. As such, TROPOMI-SWIR is an excellent test case to explore the methodology of vicarious calibration applied to infrared spectroscopy. Using methodology developed for the vicarious calibration of the OCO-2 and GOSAT missions, the absolute radiometry of TROPOMI-SWIR performance is independently verified to be stable down to ~ 6–10 % using the Railroad Valley, both on the absolute and, thus, relative radiometric calibration. Differences with the onboard calibration originate from the BRDF effects of the desert surface, the large variety in viewing angles, and the different sizes of footprints of the TROPOMI pixels. However, vicarious calibration is shown to be an additional valuable tool in validating radiance-level performances of infra-red instruments such as TROPOMI-SWIR in the field of atmospheric composition.
- 16 June 2023
- Published by Copernicus GmbH
- Vol. 2023, 1-32
Open AccessReply on RC2
The SWIR module of the TROPOMI instrument on board ESA's Sentinel-5p mission has been very stable during its five years in orbit. Calibration was performed on-ground, complemented by measurements during inflight instrument commissioning. The radiometric response and general performance of the SWIR module are monitored by onboard calibration sources. We show that after five years in orbit, TROPOMI-SWIR has continued to show excellent performance with degradation of at most 0.1 % in transmission and having lost less than 0.3 % of the detector pixels. Independent validation of the instrument calibration, via vicarious calibration, can be done through comparisons with ground-based reflectance data. In this work, measurements at the Railroad Valley Playa are used to perform vicarious calibration of the TROPOMI-SWIR measurements, using both dedicated measurement campaigns, as well as automated reflectance measurements through RADCALNET. As such, TROPOMI-SWIR is an excellent test case to explore the methodology of vicarious calibration applied to infrared spectroscopy. Using methodology developed for the vicarious calibration of the OCO-2 and GOSAT missions, the absolute radiometry of TROPOMI-SWIR performance is independently verified to be stable down to ~ 6–10 % using the Railroad Valley, both on the absolute and, thus, relative radiometric calibration. Differences with the onboard calibration originate from the BRDF effects of the desert surface, the large variety in viewing angles, and the different sizes of footprints of the TROPOMI pixels. However, vicarious calibration is shown to be an additional valuable tool in validating radiance-level performances of infra-red instruments such as TROPOMI-SWIR in the field of atmospheric composition.
- Open Access
- 5 June 2023
- Published by Copernicus GmbH
- Vol. 2023, 1-32
Comment on egusphere-2023-89
The SWIR module of the TROPOMI instrument on board ESA's Sentinel-5p mission has been very stable during its five years in orbit. Calibration was performed on-ground, complemented by measurements during inflight instrument commissioning. The radiometric response and general performance of the SWIR module are monitored by onboard calibration sources. We show that after five years in orbit, TROPOMI-SWIR has continued to show excellent performance with degradation of at most 0.1 % in transmission and having lost less than 0.3 % of the detector pixels. Independent validation of the instrument calibration, via vicarious calibration, can be done through comparisons with ground-based reflectance data. In this work, measurements at the Railroad Valley Playa are used to perform vicarious calibration of the TROPOMI-SWIR measurements, using both dedicated measurement campaigns, as well as automated reflectance measurements through RADCALNET. As such, TROPOMI-SWIR is an excellent test case to explore the methodology of vicarious calibration applied to infrared spectroscopy. Using methodology developed for the vicarious calibration of the OCO-2 and GOSAT missions, the absolute radiometry of TROPOMI-SWIR performance is independently verified to be stable down to ~ 6–10 % using the Railroad Valley, both on the absolute and, thus, relative radiometric calibration. Differences with the onboard calibration originate from the BRDF effects of the desert surface, the large variety in viewing angles, and the different sizes of footprints of the TROPOMI pixels. However, vicarious calibration is shown to be an additional valuable tool in validating radiance-level performances of infra-red instruments such as TROPOMI-SWIR in the field of atmospheric composition.
- 5 June 2023
- Published by Copernicus GmbH
- Vol. 2023, 1-32
Open AccessComment on egusphere-2023-89
The SWIR module of the TROPOMI instrument on board ESA's Sentinel-5p mission has been very stable during its five years in orbit. Calibration was performed on-ground, complemented by measurements during inflight instrument commissioning. The radiometric response and general performance of the SWIR module are monitored by onboard calibration sources. We show that after five years in orbit, TROPOMI-SWIR has continued to show excellent performance with degradation of at most 0.1 % in transmission and having lost less than 0.3 % of the detector pixels. Independent validation of the instrument calibration, via vicarious calibration, can be done through comparisons with ground-based reflectance data. In this work, measurements at the Railroad Valley Playa are used to perform vicarious calibration of the TROPOMI-SWIR measurements, using both dedicated measurement campaigns, as well as automated reflectance measurements through RADCALNET. As such, TROPOMI-SWIR is an excellent test case to explore the methodology of vicarious calibration applied to infrared spectroscopy. Using methodology developed for the vicarious calibration of the OCO-2 and GOSAT missions, the absolute radiometry of TROPOMI-SWIR performance is independently verified to be stable down to ~ 6–10 % using the Railroad Valley, both on the absolute and, thus, relative radiometric calibration. Differences with the onboard calibration originate from the BRDF effects of the desert surface, the large variety in viewing angles, and the different sizes of footprints of the TROPOMI pixels. However, vicarious calibration is shown to be an additional valuable tool in validating radiance-level performances of infra-red instruments such as TROPOMI-SWIR in the field of atmospheric composition.
- Open Access
- 10 March 2023
- Published by Copernicus GmbH
- Vol. 2023, 1-32
Comment on egusphere-2023-89
The SWIR module of the TROPOMI instrument on board ESA's Sentinel-5p mission has been very stable during its five years in orbit. Calibration was performed on-ground, complemented by measurements during inflight instrument commissioning. The radiometric response and general performance of the SWIR module are monitored by onboard calibration sources. We show that after five years in orbit, TROPOMI-SWIR has continued to show excellent performance with degradation of at most 0.1 % in transmission and having lost less than 0.3 % of the detector pixels. Independent validation of the instrument calibration, via vicarious calibration, can be done through comparisons with ground-based reflectance data. In this work, measurements at the Railroad Valley Playa are used to perform vicarious calibration of the TROPOMI-SWIR measurements, using both dedicated measurement campaigns, as well as automated reflectance measurements through RADCALNET. As such, TROPOMI-SWIR is an excellent test case to explore the methodology of vicarious calibration applied to infrared spectroscopy. Using methodology developed for the vicarious calibration of the OCO-2 and GOSAT missions, the absolute radiometry of TROPOMI-SWIR performance is independently verified to be stable down to ~ 6–10 % using the Railroad Valley, both on the absolute and, thus, relative radiometric calibration. Differences with the onboard calibration originate from the BRDF effects of the desert surface, the large variety in viewing angles, and the different sizes of footprints of the TROPOMI pixels. However, vicarious calibration is shown to be an additional valuable tool in validating radiance-level performances of infra-red instruments such as TROPOMI-SWIR in the field of atmospheric composition.
- 10 March 2023
- Published by Copernicus GmbH
- Vol. 2023, 1-32
Open AccessComment on egusphere-2023-89
The SWIR module of the TROPOMI instrument on board ESA's Sentinel-5p mission has been very stable during its five years in orbit. Calibration was performed on-ground, complemented by measurements during inflight instrument commissioning. The radiometric response and general performance of the SWIR module are monitored by onboard calibration sources. We show that after five years in orbit, TROPOMI-SWIR has continued to show excellent performance with degradation of at most 0.1 % in transmission and having lost less than 0.3 % of the detector pixels. Independent validation of the instrument calibration, via vicarious calibration, can be done through comparisons with ground-based reflectance data. In this work, measurements at the Railroad Valley Playa are used to perform vicarious calibration of the TROPOMI-SWIR measurements, using both dedicated measurement campaigns, as well as automated reflectance measurements through RADCALNET. As such, TROPOMI-SWIR is an excellent test case to explore the methodology of vicarious calibration applied to infrared spectroscopy. Using methodology developed for the vicarious calibration of the OCO-2 and GOSAT missions, the absolute radiometry of TROPOMI-SWIR performance is independently verified to be stable down to ~ 6–10 % using the Railroad Valley, both on the absolute and, thus, relative radiometric calibration. Differences with the onboard calibration originate from the BRDF effects of the desert surface, the large variety in viewing angles, and the different sizes of footprints of the TROPOMI pixels. However, vicarious calibration is shown to be an additional valuable tool in validating radiance-level performances of infra-red instruments such as TROPOMI-SWIR in the field of atmospheric composition.