Chiheb Rebai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chiheb Rebai has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
- Manel Ben-Romdhane
COSIM Research Laboratory, SUP’COM, University of Carthage, Ariana 2083, Tunisia
33 shared publications Adel Ghazel
23 shared publicationsDominique Dallet
IMS-ENSEIRB, CNRS UMR 5218, 351 Cours de la Libération, 33405, Talence, Cedex, France
15 shared publications- Asma Maalej
GRESCOM Research Lab., SUP'COM, University of Carthage, Tunisia Cité Technologique des Communications, 2083 El Ghazala, Ariana
14 shared publications Patricia Desgreys
10 shared publicationsPatrick Loumeau
10 shared publications
Latest Publications
- Open Access
The Environmental Impacts of Radio Frequency and Power Line Communication for Advanced Metering Infrastructures in Smart Grids
In the neighborhood area network (NAN), the advanced metering infrastructure (AMI) enables a bidirectional connection between the smart meter (SM) and the data concentrator (DC). Sensors, such as smart meter nodes or environmental sensor nodes, play a crucial role in measuring and transmitting data to central units for advanced monitoring, management, and analysis of energy consumption. Wired and wireless communication technologies are used to implement the AMI-NAN. This paper delves into a novel approach for optimizing the choice of communication medium, air for radio frequency (RF) or power lines for power line communication (PLC), between the SM and DC in the context of the AMI-NAN. The authors methodically select the specific technologies, RF and NB-PLC (narrowband power line communication), and meticulously characterize their attributes. Then, a comparative analysis spanning rural, urban, and industrial settings is conducted to evaluate the proposed method. The overall reliability performance of the AMI-NAN system requires a packet error rate (PER) lower than 10%. To this end, an efficient approach is introduced to assess and enhance the reliability of NB-PLC and RF for AMI-NAN applications. Simulation results demonstrate that wireless communication is the optimal choice for the rural scenario, especially for a signal-to-noise ratio (SNR) lower than 25 dB. However, in urban environments characterized by higher SNR values and moderately dense networks, NB-PLC gains prominence. In denser networks, it outperforms wireless communication, exhibiting a remarkable 10 dB gain for a bit error rate (BER) of 10−3. Moreover, in industrial zones characterized by intricate network topologies and non-linear loads, the power line channel emerges as the optimal choice for data transmission.
Open AccessThe Environmental Impacts of Radio Frequency and Power Line Communication for Advanced Metering Infrastructures in Smart Grids
In the neighborhood area network (NAN), the advanced metering infrastructure (AMI) enables a bidirectional connection between the smart meter (SM) and the data concentrator (DC). Sensors, such as smart meter nodes or environmental sensor nodes, play a crucial role in measuring and transmitting data to central units for advanced monitoring, management, and analysis of energy consumption. Wired and wireless communication technologies are used to implement the AMI-NAN. This paper delves into a novel approach for optimizing the choice of communication medium, air for radio frequency (RF) or power lines for power line communication (PLC), between the SM and DC in the context of the AMI-NAN. The authors methodically select the specific technologies, RF and NB-PLC (narrowband power line communication), and meticulously characterize their attributes. Then, a comparative analysis spanning rural, urban, and industrial settings is conducted to evaluate the proposed method. The overall reliability performance of the AMI-NAN system requires a packet error rate (PER) lower than 10%. To this end, an efficient approach is introduced to assess and enhance the reliability of NB-PLC and RF for AMI-NAN applications. Simulation results demonstrate that wireless communication is the optimal choice for the rural scenario, especially for a signal-to-noise ratio (SNR) lower than 25 dB. However, in urban environments characterized by higher SNR values and moderately dense networks, NB-PLC gains prominence. In denser networks, it outperforms wireless communication, exhibiting a remarkable 10 dB gain for a bit error rate (BER) of 10−3. Moreover, in industrial zones characterized by intricate network topologies and non-linear loads, the power line channel emerges as the optimal choice for data transmission.
- Open Access
- 14 September 2023
- Published by MDPI AG in Preprints.org
Environmental Impact on RF and PLC for Advanced Metering Infrastructure in Smart Grids
In the Neighborhood Area Network (NAN), the Advanced Metering Infrastructure (AMI) enables a bidirectional connection between the Smart Meter (SM) and the Data Concentrator (DC). Sensors, such as smart meter node or Radio Frequency transceiver, play a crucial role in collecting and transmitting data from meters to central unit for advanced monitoring, management, and analysis of energy consumption. Wired and wireless communication technologies can be used to implement the AMI-NAN. This paper delves into a novel approach for optimizing the choice of communication medium, Radio Frequency (RF) or Power-Line Communication (PLC), between the SM and DC in the context of AMI-NAN. The authors methodically select the specific technologies, RF and NB-PLC (Narrow Band Power-Line Communication), and meticulously characterize their attributes. Then, a comparative analysis spanning rural, urban, and industrial settings is conducted to evaluate the proposed method. The overall reliability performance of the AMI-NAN system requires a Packet Error Rate (PER) lower than 10%. To this end, a comprehensive methodology is introduced to assess and enhance the reliability of NB-PLC and RF for AMI-NAN applications. Simulation results demonstrate that wireless communication is the optimal choice for the rural scenario, especially for Signal to Noise Ratio (SNR) lower than 25 dB. However, in urban environments characterized by higher SNR values and moderately dense networks, NB-PLC gains prominence. In denser networks, it outperforms wireless communication, exhibiting a remarkable 10 dB gain for a bit error rate (BER) of 10-3. Moreover, in industrial zones characterized by intricate network topologies and non-linear loads, the powerline channel emerges as the optimal choice for data transmission, affording a gain surpassing 20 dB.
- 14 September 2023
- Published by MDPI AG in Preprints.org
Open AccessEnvironmental Impact on RF and PLC for Advanced Metering Infrastructure in Smart Grids
In the Neighborhood Area Network (NAN), the Advanced Metering Infrastructure (AMI) enables a bidirectional connection between the Smart Meter (SM) and the Data Concentrator (DC). Sensors, such as smart meter node or Radio Frequency transceiver, play a crucial role in collecting and transmitting data from meters to central unit for advanced monitoring, management, and analysis of energy consumption. Wired and wireless communication technologies can be used to implement the AMI-NAN. This paper delves into a novel approach for optimizing the choice of communication medium, Radio Frequency (RF) or Power-Line Communication (PLC), between the SM and DC in the context of AMI-NAN. The authors methodically select the specific technologies, RF and NB-PLC (Narrow Band Power-Line Communication), and meticulously characterize their attributes. Then, a comparative analysis spanning rural, urban, and industrial settings is conducted to evaluate the proposed method. The overall reliability performance of the AMI-NAN system requires a Packet Error Rate (PER) lower than 10%. To this end, a comprehensive methodology is introduced to assess and enhance the reliability of NB-PLC and RF for AMI-NAN applications. Simulation results demonstrate that wireless communication is the optimal choice for the rural scenario, especially for Signal to Noise Ratio (SNR) lower than 25 dB. However, in urban environments characterized by higher SNR values and moderately dense networks, NB-PLC gains prominence. In denser networks, it outperforms wireless communication, exhibiting a remarkable 10 dB gain for a bit error rate (BER) of 10-3. Moreover, in industrial zones characterized by intricate network topologies and non-linear loads, the powerline channel emerges as the optimal choice for data transmission, affording a gain surpassing 20 dB.
- 31 March 2020
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 45 (8) , 6361-6387
Event-Driven ECG Sensor in Healthcare Devices for Data Transfer Optimization
The long-term monitoring of cardiovascular signs requires a wearable and connected electrocardiogram (ECG) healthcare device. It increases user’s comfort and diagnosis quality of chronic cardiac and/or high-risk patients. This paper covers the enormous data to be transmitted from the ECG device to the physician’s, namely the cardiologist’s, control unit. Existent ECG devices uniformly sample analog signals and convert them to digital samples which are compressed before data transmission. However, event-driven sampling simultaneously compresses and samples. Therefore, this paper quantitatively compares successive approximation register analog-to-digital converter (SAR ADC) with discrete wavelet transform (DWT) compression and level-crossing analog-to-digital converter (LC-ADC). Evaluation metrics are the percent root-mean-square difference (\( {\text{PRD}} \)), bit compression ratio (\( {\text{BCR}} \)) and data length in bits. When a 12-bit reconstruction is operated on the outputs of an 8-bit LC-ADC with 12-bit and 10-kHz reference counter, the \( {\text{BCR}} \) is equal to 80% for 75% of test ECG signals. That is better than the 71.87% \( {\text{BCR}} \) of the 12-bit 1-kHz SAR ADC with DWT compression. The modeled LC-ADC guarantees a signal quality in terms of \( {\text{PRD}} \) comparable to the \( {\text{PRD}} \) of the SAR ADC with DWT compression. The data length in bits of the LC-ADC is lower than the data length in bits of the SAR ADC with more than 14-bit resolution with DWT compression for 82% of the test ECG signals. However, for lower resolutions, to obtain lower power consumption for radiofrequency transmission, a better alternative remains the SAR ADC with DWT compression.- 31 March 2020
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 45 (8) , 6361-6387
Event-Driven ECG Sensor in Healthcare Devices for Data Transfer Optimization
The long-term monitoring of cardiovascular signs requires a wearable and connected electrocardiogram (ECG) healthcare device. It increases user’s comfort and diagnosis quality of chronic cardiac and/or high-risk patients. This paper covers the enormous data to be transmitted from the ECG device to the physician’s, namely the cardiologist’s, control unit. Existent ECG devices uniformly sample analog signals and convert them to digital samples which are compressed before data transmission. However, event-driven sampling simultaneously compresses and samples. Therefore, this paper quantitatively compares successive approximation register analog-to-digital converter (SAR ADC) with discrete wavelet transform (DWT) compression and level-crossing analog-to-digital converter (LC-ADC). Evaluation metrics are the percent root-mean-square difference (\( {\text{PRD}} \)), bit compression ratio (\( {\text{BCR}} \)) and data length in bits. When a 12-bit reconstruction is operated on the outputs of an 8-bit LC-ADC with 12-bit and 10-kHz reference counter, the \( {\text{BCR}} \) is equal to 80% for 75% of test ECG signals. That is better than the 71.87% \( {\text{BCR}} \) of the 12-bit 1-kHz SAR ADC with DWT compression. The modeled LC-ADC guarantees a signal quality in terms of \( {\text{PRD}} \) comparable to the \( {\text{PRD}} \) of the SAR ADC with DWT compression. The data length in bits of the LC-ADC is lower than the data length in bits of the SAR ADC with more than 14-bit resolution with DWT compression for 82% of the test ECG signals. However, for lower resolutions, to obtain lower power consumption for radiofrequency transmission, a better alternative remains the SAR ADC with DWT compression.- 1 August 2018
- Published by Elsevier in Measurement
- Vol. 124, 413-425
Level-crossing ADC design and evaluation methodology for normal and pathological electrocardiogram signals measurement
- 1 August 2018
- Published by Elsevier in Measurement
- Vol. 124, 413-425
Level-crossing ADC design and evaluation methodology for normal and pathological electrocardiogram signals measurement
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 125-131
Comparison of different channel modeling techniques used in NB-PLC systems
Using Power Line communication (PLC) is suitable for several Smart Grid applications. Due to the absence of applicable channel model, PLC systems have been slowed down. This paper compares different channel models of Narrowband Power-Line Communication (NB-PLC) which are voltage ratio approach (VRA), ABCD approach, multipath and finite impulse response filter (FIR). Simulation results show that ABCD and VRA methods have not the same behavior despite the same condition of network. It is seen that when the number of branches is increased the channel becomes very frequency selective and the attenuation is dependent also from the length of the cable, frequency and the nature of loads connected to the network. It is therefore suggested that NB-PLC channel modeling will not be based on a mathematical equation of the method but the variation of its transfer function in real time depending on several parameters such as network topology, branches number, charges, and branch length.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 125-131
Comparison of different channel modeling techniques used in NB-PLC systems
Using Power Line communication (PLC) is suitable for several Smart Grid applications. Due to the absence of applicable channel model, PLC systems have been slowed down. This paper compares different channel models of Narrowband Power-Line Communication (NB-PLC) which are voltage ratio approach (VRA), ABCD approach, multipath and finite impulse response filter (FIR). Simulation results show that ABCD and VRA methods have not the same behavior despite the same condition of network. It is seen that when the number of branches is increased the channel becomes very frequency selective and the attenuation is dependent also from the length of the cable, frequency and the nature of loads connected to the network. It is therefore suggested that NB-PLC channel modeling will not be based on a mathematical equation of the method but the variation of its transfer function in real time depending on several parameters such as network topology, branches number, charges, and branch length.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Time-domain characterization of a wireless ECG system event driven A/D converter
Heart strokes are one of the leading cause of global deaths. In order to prevent such strokes, a variety of wearable devices have been proposed recently. These are based on the wireless Electrocardiogram (ECG) acquisition, analysis and transmission. An efficient acquisition, analysis and transmission of such signals can be achieved by adapting the system activity according to the input signal local characteristics. In this context, an event driven analog-to-digital converter (ADC) based on level-crossing sampling scheme (LCSS) is designed for the ECG acquisition. The analog-to-digital (A/D) conversion error is a vital parameter to characterize its performance. It implicitly provides information about the ADC effective resolution. In this context, a novel method is proposed to measure the conversion error in time domain of the designed level-crossing ADC (LC-ADC). In the aim of acquiring the desired conversion precision, a criterion for properly choosing the system parameters is also discussed.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Time-domain characterization of a wireless ECG system event driven A/D converter
Heart strokes are one of the leading cause of global deaths. In order to prevent such strokes, a variety of wearable devices have been proposed recently. These are based on the wireless Electrocardiogram (ECG) acquisition, analysis and transmission. An efficient acquisition, analysis and transmission of such signals can be achieved by adapting the system activity according to the input signal local characteristics. In this context, an event driven analog-to-digital converter (ADC) based on level-crossing sampling scheme (LCSS) is designed for the ECG acquisition. The analog-to-digital (A/D) conversion error is a vital parameter to characterize its performance. It implicitly provides information about the ADC effective resolution. In this context, a novel method is proposed to measure the conversion error in time domain of the designed level-crossing ADC (LC-ADC). In the aim of acquiring the desired conversion precision, a criterion for properly choosing the system parameters is also discussed.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Impact of equalization on hybrid communication system for smart grid
This paper investigates the impact of advanced signal processing techniques on a communication through Advanced Metering Infrastructure (AMI) in smart grid. While the Narrowband Powerline channel (NB-PLC) is very harsh, we propose to use two h e t e r o g e n e o u s environments: wireless (RF) and wired (NB-PLC) channels. Authors present channel estimation techniques based on Least Squares (LS) and Minimum Mean Square Error (MMSE) algorithms and channel equalization based on Zero Forcing (Z F) and Minimum Mean Square Error (M M SE) methods. Performances analysis show that the MMSE channel estimator is better than the LS estimator in terms of mean square error for the two environments and the MMSE equalizer used for NB-PLC channel do not have good performances. Therefore, environment diversity can be exploited to enhance our system reliability.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Impact of equalization on hybrid communication system for smart grid
This paper investigates the impact of advanced signal processing techniques on a communication through Advanced Metering Infrastructure (AMI) in smart grid. While the Narrowband Powerline channel (NB-PLC) is very harsh, we propose to use two h e t e r o g e n e o u s environments: wireless (RF) and wired (NB-PLC) channels. Authors present channel estimation techniques based on Least Squares (LS) and Minimum Mean Square Error (MMSE) algorithms and channel equalization based on Zero Forcing (Z F) and Minimum Mean Square Error (M M SE) methods. Performances analysis show that the MMSE channel estimator is better than the LS estimator in terms of mean square error for the two environments and the MMSE equalizer used for NB-PLC channel do not have good performances. Therefore, environment diversity can be exploited to enhance our system reliability.
- 1 August 2016
- Published by Elsevier in Measurement
- Vol. 90, 158-167
Statistical modeling of mains zero crossing variation in powerline communication
- 1 August 2016
- Published by Elsevier in Measurement
- Vol. 90, 158-167
Statistical modeling of mains zero crossing variation in powerline communication
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Level-crossing ADC modeling for wireless electrocardiogram signal acquisition system
The wireless biomedical acquisition and transmission (Wibio'ACT) is a contributive project for real-time electrocardiogram (ECG) monitoring based on a special level-crossing analog-to-digital converter (LC-ADC). The authors present, as the first step in their design flow, modeling and simulation results of the converter in the presence of noise in ECG and comparator errors. Compared to pulse code modulation (PCM) and differential pulse code modulation (DPCM), it is shown that the LC-ADC is more suitable for the digitization of the biomedical signal. Using LC-ADC allows achieving a percentage root mean square difference (PRD) less than 2 % which is the criteria for an efficient reconstructed signal quality. As far as it concerns the comparator non-idealities, a comparator delay higher than 4 ns, which is equal to 0.21 % of the LC-ADC timer clock period, may imply a PRD higher than 2 %. Besides, the comparator offset voltage impact varies with the design considerations namely the bit resolution and the timer clock period.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Level-crossing ADC modeling for wireless electrocardiogram signal acquisition system
The wireless biomedical acquisition and transmission (Wibio'ACT) is a contributive project for real-time electrocardiogram (ECG) monitoring based on a special level-crossing analog-to-digital converter (LC-ADC). The authors present, as the first step in their design flow, modeling and simulation results of the converter in the presence of noise in ECG and comparator errors. Compared to pulse code modulation (PCM) and differential pulse code modulation (DPCM), it is shown that the LC-ADC is more suitable for the digitization of the biomedical signal. Using LC-ADC allows achieving a percentage root mean square difference (PRD) less than 2 % which is the criteria for an efficient reconstructed signal quality. As far as it concerns the comparator non-idealities, a comparator delay higher than 4 ns, which is equal to 0.21 % of the LC-ADC timer clock period, may imply a PRD higher than 2 %. Besides, the comparator offset voltage impact varies with the design considerations namely the bit resolution and the timer clock period.
- Open Access
- 31 March 2016
- Published by Research Institute for Intelligent Computer Systems in International Journal of Computing
- p. 14-21
PROGRAMMABLE PARALLEL FBD SIGMA DELTA ADC RECONSTRUCTION STAGE DESIGN FOR SOFTWARE DEFINED RADIO RECEIVER
Today’s bottleneck of signal processing in multistandard software defined radio (SDR) receiver is the analog-to-digital converter (ADC). Therefore, the authors present in this paper the design and simulation results of a programmable parallel frequency band decomposition (FBD) architecture for ADC. The designed parallel architecture is composed of six parallel branches based on discrete-time (DT) 4th order sigma delta modulators using single-bit quantizers. Each branch processes a sub-bandwidth of the received signal. Only needed branches are selected according to the chosen standard. The parallel sigma delta modulators’ outputs are handled by a demodulation-based digital reconstruction stage in order to provide the FBD sigma delta-based ADC output signal. The digital reconstruction stage differs from one communication standard to another. In this paper, its design is discussed for the UMTS use case. The objective is to propose a digital reconstruction design with optimized complexity. In fact, the authors propose a comparative study between some configurations of demodulation, decimation and filtering processes. Technical choices and simulation results are discussed. For UMTS use case, the proposed FBD sigma delta-based ADC architecture ensures a computed signal-to-noise ratio (SNR) over 74 dB.
- 31 March 2016
- Published by Research Institute for Intelligent Computer Systems in International Journal of Computing
- p. 14-21
Open AccessPROGRAMMABLE PARALLEL FBD SIGMA DELTA ADC RECONSTRUCTION STAGE DESIGN FOR SOFTWARE DEFINED RADIO RECEIVER
Today’s bottleneck of signal processing in multistandard software defined radio (SDR) receiver is the analog-to-digital converter (ADC). Therefore, the authors present in this paper the design and simulation results of a programmable parallel frequency band decomposition (FBD) architecture for ADC. The designed parallel architecture is composed of six parallel branches based on discrete-time (DT) 4th order sigma delta modulators using single-bit quantizers. Each branch processes a sub-bandwidth of the received signal. Only needed branches are selected according to the chosen standard. The parallel sigma delta modulators’ outputs are handled by a demodulation-based digital reconstruction stage in order to provide the FBD sigma delta-based ADC output signal. The digital reconstruction stage differs from one communication standard to another. In this paper, its design is discussed for the UMTS use case. The objective is to propose a digital reconstruction design with optimized complexity. In fact, the authors propose a comparative study between some configurations of demodulation, decimation and filtering processes. Technical choices and simulation results are discussed. For UMTS use case, the proposed FBD sigma delta-based ADC architecture ensures a computed signal-to-noise ratio (SNR) over 74 dB.