Predrag Bozovic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Predrag Bozovic has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Danijela Arandjic
Institute of General and Physical Chemistry, Belgrade
7 shared publications- Olivera Ciraj-Bjelac
Department of Nuclear Sciences and Applications, International Atomic Energy Agency, Vienna, Austria
7 shared publications Jelena Stankovic
3 shared publicationsSanja Stojanovic
3 shared publications- Andrea Kojić
Vinča Institute of Nuclear Science, National Institute of the Republic of Serbia, University of Belgrade, Mike Petrovića Alasa 12-14, 11351 Vinča, Belgrade, Serbia; Faculty of Physics, University of Belgrade, Studentski trg 12-14, 11000 Belgrade, Serbia
2 shared publications - Darka Hadnadjev-Simonji
University Clinical Center of Vojvodina, Center for Radiology, Novi Sad, Serbia
2 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 40 (4) , 312-321
Exploring the nexus between ionizing radiation and breast cancer in silico mapping of the adverse outcome pathway
Breast cancer, the most common malignancy in women, accounts for 36 % of cancer cases, with its incidence rising, and ionizing radiation is one of the contributing risk factors. This study aimed to: investigate the link between breast cancer and ionizing radiation through in silico analysis, map the adverse outcome pathway connecting ionizing radiation to breast cancer, and propose additional key events to refine and enhance the adverse outcome pathway. The following publicly available databases, software, and tools were used: Comparative Toxicogenomics Database, ToppGene Suite, GeneMANIA server, and Metascape. Twenty identified genomic biomarkers (ATM, BARD1, BRCA1, BRCA2, CHEK2, E2F1, FBL, H2AX, HRAS, MDM2, RAD51, SIRT1, SNAI2, SFRP1, SFRP2, TANK, TP53, TRP53, TP53BP1, YAPI) were predominantly in physical interactions (57.48 %), or belonged to the same pathway (19.99%), contributing to molecular functions associated with regulating cellular responses to DNA damage, double-strand break repair, and DNA integrity checkpoint signaling. These biomarkers exhibit binding capabilities to molecules such as p53, ubiquitin, transcription factors, and chromatin. These findings, combined with the existing breast cancer-ionizing radiation, provide a foundation for future research on ionizing radiation's molecular impact on breast cancer development, with biomarkers supporting early detection and prognosis.
- 1 January 2025
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 40 (4) , 312-321
Open AccessExploring the nexus between ionizing radiation and breast cancer in silico mapping of the adverse outcome pathway
Breast cancer, the most common malignancy in women, accounts for 36 % of cancer cases, with its incidence rising, and ionizing radiation is one of the contributing risk factors. This study aimed to: investigate the link between breast cancer and ionizing radiation through in silico analysis, map the adverse outcome pathway connecting ionizing radiation to breast cancer, and propose additional key events to refine and enhance the adverse outcome pathway. The following publicly available databases, software, and tools were used: Comparative Toxicogenomics Database, ToppGene Suite, GeneMANIA server, and Metascape. Twenty identified genomic biomarkers (ATM, BARD1, BRCA1, BRCA2, CHEK2, E2F1, FBL, H2AX, HRAS, MDM2, RAD51, SIRT1, SNAI2, SFRP1, SFRP2, TANK, TP53, TRP53, TP53BP1, YAPI) were predominantly in physical interactions (57.48 %), or belonged to the same pathway (19.99%), contributing to molecular functions associated with regulating cellular responses to DNA damage, double-strand break repair, and DNA integrity checkpoint signaling. These biomarkers exhibit binding capabilities to molecules such as p53, ubiquitin, transcription factors, and chromatin. These findings, combined with the existing breast cancer-ionizing radiation, provide a foundation for future research on ionizing radiation's molecular impact on breast cancer development, with biomarkers supporting early detection and prognosis.
- Open Access
- 1 January 2023
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 38 (3) , 202-207
Assessment of occupational eye lens exposure during image-guided orthopedic procedures
This study aimed to investigate the level of exposure of eye lenses in orthopedic surgeons performing routine clinical work and to determine future monitoring practice, as Serbian radiation protection law still employs higher limits. The dose was measured monthly in terms of H (0.03) with three different dosimeters placed on a 3-D-printed headband, worn on a forehead by three orthopedic surgeons, during all procedures involving fluoroscopy. The mean dose for the left and right eye was 271 ? 109 ?Sv and 269 ? 101 ?Sv, respectively, with no significant difference (p-value 0.977) between the left and right eye observed. Considering the highest recorded monthly value, the annual dose is expected to be 4.85 mSv without protective items, well below the new ICRP limit of 20 mSv. There was no observed correlation between eye lens dose and both fluoroscopy time and exposure parameters. Considering the cumulative impact of dose and the evidence pointing to an elevated incidence of lenticular opacities for cumulative doses exceeding 10 mSv, it is advisable to institute ongoing monitoring, especially when new surgeons incorporate image-guided procedures or when novel techniques are introduced into surgical practice.
- 1 January 2023
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 38 (3) , 202-207
Open AccessAssessment of occupational eye lens exposure during image-guided orthopedic procedures
This study aimed to investigate the level of exposure of eye lenses in orthopedic surgeons performing routine clinical work and to determine future monitoring practice, as Serbian radiation protection law still employs higher limits. The dose was measured monthly in terms of H (0.03) with three different dosimeters placed on a 3-D-printed headband, worn on a forehead by three orthopedic surgeons, during all procedures involving fluoroscopy. The mean dose for the left and right eye was 271 ? 109 ?Sv and 269 ? 101 ?Sv, respectively, with no significant difference (p-value 0.977) between the left and right eye observed. Considering the highest recorded monthly value, the annual dose is expected to be 4.85 mSv without protective items, well below the new ICRP limit of 20 mSv. There was no observed correlation between eye lens dose and both fluoroscopy time and exposure parameters. Considering the cumulative impact of dose and the evidence pointing to an elevated incidence of lenticular opacities for cumulative doses exceeding 10 mSv, it is advisable to institute ongoing monitoring, especially when new surgeons incorporate image-guided procedures or when novel techniques are introduced into surgical practice.
- Open Access
- 1 January 2022
- Published by RAD Centre
Investigation on the potential of improvement in the field of medical applications of ionizing radiation via the future European Metrology Network
- 1 January 2022
- Published by RAD Centre
Open AccessInvestigation on the potential of improvement in the field of medical applications of ionizing radiation via the future European Metrology Network
- Open Access
- 1 January 2022
- Published by RAD Centre
Establishing W/Al mammography radiation qualities in Secondary Standard Dosimetry Laboratory
- 1 January 2022
- Published by RAD Centre
Open AccessEstablishing W/Al mammography radiation qualities in Secondary Standard Dosimetry Laboratory
- Open Access
- 1 January 2022
- Published by RAD Centre
Implementation of a new IAEA remote and automated quality control program for radiography equipment
- 1 January 2022
- Published by RAD Centre
Open AccessImplementation of a new IAEA remote and automated quality control program for radiography equipment
- Open Access
- 1 January 2021
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 36 (2) , 163-167
Mathematical modeling of Cs+ transport phenomena from solidified spent ion exchange resin
The aim of the study was to assess Cs+ ions transport phenomena from solidified spent ion exchange resin by mathematical modeling. The experimental results comparison was obtained by Hespe's Standard Leaching Method. For the leaching prediction rate as a function of time, diffusion and semi-empirical models were used. Due to the presence of spent ion exchange resin, the cement matrix absorbed a larger amount of water, swelled, and degraded. This phenomenon caused a significantly lower value of mechanical resistance to pressure. Also, through the increase of bentonite and zeolite content, the cement matrix decreased its mechanical resistance. The retention of cesium ions in the cement matrix was low and they were leached during the early phase of the investigation. The diffusion coefficient, De, decreased by three orders of magnitude with the addition of zeolite and bentonite in the cement matrix. Linear regression of experimental Cs+ leaching results, under static conditions, displayed that the semi-empirical parameter K3 than the absolute values of the parameters K2 and K1. Therefore, the contribution of matrix dissolution to the total radionuclides transport was irrelevant to the prevailing share of diffusion and surface washing processes.
- 1 January 2021
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 36 (2) , 163-167
Open AccessMathematical modeling of Cs+ transport phenomena from solidified spent ion exchange resin
The aim of the study was to assess Cs+ ions transport phenomena from solidified spent ion exchange resin by mathematical modeling. The experimental results comparison was obtained by Hespe's Standard Leaching Method. For the leaching prediction rate as a function of time, diffusion and semi-empirical models were used. Due to the presence of spent ion exchange resin, the cement matrix absorbed a larger amount of water, swelled, and degraded. This phenomenon caused a significantly lower value of mechanical resistance to pressure. Also, through the increase of bentonite and zeolite content, the cement matrix decreased its mechanical resistance. The retention of cesium ions in the cement matrix was low and they were leached during the early phase of the investigation. The diffusion coefficient, De, decreased by three orders of magnitude with the addition of zeolite and bentonite in the cement matrix. Linear regression of experimental Cs+ leaching results, under static conditions, displayed that the semi-empirical parameter K3 than the absolute values of the parameters K2 and K1. Therefore, the contribution of matrix dissolution to the total radionuclides transport was irrelevant to the prevailing share of diffusion and surface washing processes.
- Open Access
- 1 January 2018
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 33 (4) , 375-379
Utilizing Monte Carlo simulations in estimation of occupational eye lens dose based on whole body dosemeter in interventional cardiology and radiology
Medical staff performing interventional procedures in cardiology and radiology is considered to be a professional group exposed to high doses of ionizing radiation. With new epidemiological evidences and recently reduced eye lens dose limit, dose assessment to the lens of the eye, in the interventional cardiology, has become one of the most challenging research topics. This paper presents results of the eye lens dose assessment in interventional cardiology obtained by means of the computational dosimetry. Since placing and wearing the dedicated eye lens dosimeter is encumbering for the staff, Monte Carlo simulation provides an accurate and efficient method for obtaining an indication of doses to the eye lenses. Eye lens doses were estimated for three typical beam projections (PA, LAO, and RAO) and tube voltages ranging from 80 kV to 110 kV, with different protective equipment setups, for the first operator position. Simulations were carried out using MCNPX code. Results revealed that a whole body dosimeter worn at the thyroid center position gives the best estimate of the eye lens dose with a spread from 11 % to 18 % for the left eye. Corresponding average conversion coefficient from whole body to the eye lens dose is estimated to be 0.18.
- 1 January 2018
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 33 (4) , 375-379
Open AccessUtilizing Monte Carlo simulations in estimation of occupational eye lens dose based on whole body dosemeter in interventional cardiology and radiology
Medical staff performing interventional procedures in cardiology and radiology is considered to be a professional group exposed to high doses of ionizing radiation. With new epidemiological evidences and recently reduced eye lens dose limit, dose assessment to the lens of the eye, in the interventional cardiology, has become one of the most challenging research topics. This paper presents results of the eye lens dose assessment in interventional cardiology obtained by means of the computational dosimetry. Since placing and wearing the dedicated eye lens dosimeter is encumbering for the staff, Monte Carlo simulation provides an accurate and efficient method for obtaining an indication of doses to the eye lenses. Eye lens doses were estimated for three typical beam projections (PA, LAO, and RAO) and tube voltages ranging from 80 kV to 110 kV, with different protective equipment setups, for the first operator position. Simulations were carried out using MCNPX code. Results revealed that a whole body dosimeter worn at the thyroid center position gives the best estimate of the eye lens dose with a spread from 11 % to 18 % for the left eye. Corresponding average conversion coefficient from whole body to the eye lens dose is estimated to be 0.18.
- 2 January 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 172 (4) , 475-482
EYE LENS EXPOSURE TO MEDICAL STAFF PERFORMING ELECTROPHYSIOLOGY PROCEDURES: DOSE ASSESSMENT AND CORRELATION TO PATIENT DOSE
The purpose of this study was to assess the patient exposure and staff eye dose levels during implantation procedures for all types of pacemaker therapy devices performed under fluoroscopic guidance and to investigate potential correlation between patients and staff dose levels. The mean eye dose during pacemaker/defibrillator implementation was 12 µSv for the first operator, 8.7 µSv for the second operator/nurse and 0.50 µSv for radiographer. Corresponding values for cardiac resynchronisation therapy procedures were 30, 26 and 2.0 µSv, respectively. Significant (p < 0.01) correlation between the eye dose and the kerma–area product was found for the first operator and radiographers, but not for other staff categories. The study revealed eye dose per procedure and eye dose normalised to patient dose indices for different staff categories and provided an input for radiation protection in electrophysiology procedures.
- 2 January 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 172 (4) , 475-482
EYE LENS EXPOSURE TO MEDICAL STAFF PERFORMING ELECTROPHYSIOLOGY PROCEDURES: DOSE ASSESSMENT AND CORRELATION TO PATIENT DOSE
The purpose of this study was to assess the patient exposure and staff eye dose levels during implantation procedures for all types of pacemaker therapy devices performed under fluoroscopic guidance and to investigate potential correlation between patients and staff dose levels. The mean eye dose during pacemaker/defibrillator implementation was 12 µSv for the first operator, 8.7 µSv for the second operator/nurse and 0.50 µSv for radiographer. Corresponding values for cardiac resynchronisation therapy procedures were 30, 26 and 2.0 µSv, respectively. Significant (p < 0.01) correlation between the eye dose and the kerma–area product was found for the first operator and radiographers, but not for other staff categories. The study revealed eye dose per procedure and eye dose normalised to patient dose indices for different staff categories and provided an input for radiation protection in electrophysiology procedures.
- 1 January 2016
- Published by RAD Centre
MAMMOGRAPHY IN SERBIA: IMAGE QUALITY AND RADIATION DOSE