Malcolm. L. Jones
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Malcolm. L. Jones has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
Robert B. Lawson
Division of Dental Health and Development, University of Wales College of Medicine, Cardiff, Wales
1 shared publication
Latest Publications
- 8 January 2020
- Published by Springer Nature in Journal of Psychosocial Rehabilitation and Mental Health
- Vol. 7 (1) , 97-101
Risk: A Conversation Worth Having in Mental Health Care?
- 8 January 2020
- Published by Springer Nature in Journal of Psychosocial Rehabilitation and Mental Health
- Vol. 7 (1) , 97-101
Risk: A Conversation Worth Having in Mental Health Care?
- 1 January 1998
- Published by SAGE Publications in The Cleft Palate Craniofacial Journal
- Vol. 35 (1) , 1-8
An Evaluation of a Noninvasive Method of Assessing Alveolar Bone Levels in an Experimental Model of Cleft Lip and Palate
Objective: The purpose of this study was to evaluate an ultrasound mucous-membrane-thickness-measuring device as a noninvasive, nonionizing alternative to radiography in the assessment of alveolar bone grafting. Design: This was a prospective experimental study on porcine cadaver models. Method: An ultrasound technique (Krupp SDM) was assessed ex vivo on three specially developed porcine cadaver models in comparison to radiography and ridge-mapping. Direct measurement of the mucosal thickness provided a standard for comparison. In each model, 30 measurement sites were identified for comparison of the techniques. Results: All measurement techniques demonstrated clinically acceptable re-producibility. Of the clinical measurement techniques, radiography proved to be the most reliable, showing a small, nonsignificant statistical difference from direct measurement. Both the ultrasound technique and ridge-mapping showed significant tendencies to underestimate mucosal thickness that became greater with increasing mucosal thickness. At sites where mucosal thickness was less than 6 mm, the ultrasound technique underestimated mucosal thickness by 0.6 mm on average. At sites where mucosal thickness exceeded 6 mm, ultrasonic artifacts rendered the ultrasound technique unreliable. Conclusion: The ultrasound technique could prove to be a useful clinical adjunct to radiography in the assessment of alveolar bone grafts, but in this particular application, care should be taken when using it to assess deeper alveolar defects.
- 1 January 1998
- Published by SAGE Publications in The Cleft Palate Craniofacial Journal
- Vol. 35 (1) , 1-8
An Evaluation of a Noninvasive Method of Assessing Alveolar Bone Levels in an Experimental Model of Cleft Lip and Palate
Objective: The purpose of this study was to evaluate an ultrasound mucous-membrane-thickness-measuring device as a noninvasive, nonionizing alternative to radiography in the assessment of alveolar bone grafting. Design: This was a prospective experimental study on porcine cadaver models. Method: An ultrasound technique (Krupp SDM) was assessed ex vivo on three specially developed porcine cadaver models in comparison to radiography and ridge-mapping. Direct measurement of the mucosal thickness provided a standard for comparison. In each model, 30 measurement sites were identified for comparison of the techniques. Results: All measurement techniques demonstrated clinically acceptable re-producibility. Of the clinical measurement techniques, radiography proved to be the most reliable, showing a small, nonsignificant statistical difference from direct measurement. Both the ultrasound technique and ridge-mapping showed significant tendencies to underestimate mucosal thickness that became greater with increasing mucosal thickness. At sites where mucosal thickness was less than 6 mm, the ultrasound technique underestimated mucosal thickness by 0.6 mm on average. At sites where mucosal thickness exceeded 6 mm, ultrasonic artifacts rendered the ultrasound technique unreliable. Conclusion: The ultrasound technique could prove to be a useful clinical adjunct to radiography in the assessment of alveolar bone grafts, but in this particular application, care should be taken when using it to assess deeper alveolar defects.
- 1 February 1990
- Published by SAGE Publications in British Journal of Orthodontics
- Vol. 17 (1) , 1-19
The Barry Project—a Three-Dimensional Assessment of Occlusal Treatment Change in a Consecutively Referred Sample: The Incisors
The serial occlusal changes for a consecutively referred sample of malocclusion from a Welsh town are presented. The patients were assigned to one of four treatment regimes (meant to represent those commonly used in the U.K.) and treated to a rigid protocol. Twenty-five per cent of the cases were reviewed by an eight clinician panel. No bias in the original assignments was found although there was considerable interobserver variation. At defined pretreatment, post-treatment, and post-retention stages, records were collected and the study casts quantitatively measured using a reflex metrograph and an occlusal analysis programme. The results found for the overjet, overbite, crown inclination, and crown angulation are presented and discussed.
- 1 February 1990
- Published by SAGE Publications in British Journal of Orthodontics
- Vol. 17 (1) , 1-19
The Barry Project—a Three-Dimensional Assessment of Occlusal Treatment Change in a Consecutively Referred Sample: The Incisors
The serial occlusal changes for a consecutively referred sample of malocclusion from a Welsh town are presented. The patients were assigned to one of four treatment regimes (meant to represent those commonly used in the U.K.) and treated to a rigid protocol. Twenty-five per cent of the cases were reviewed by an eight clinician panel. No bias in the original assignments was found although there was considerable interobserver variation. At defined pretreatment, post-treatment, and post-retention stages, records were collected and the study casts quantitatively measured using a reflex metrograph and an occlusal analysis programme. The results found for the overjet, overbite, crown inclination, and crown angulation are presented and discussed.