Rocio Rodriguez Gomez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rocio Rodriguez Gomez has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Zafra Gómez
José Mataix Verdú" Institute of Nutrition and Food Technology (INYTA), Biomedical Research Centre (CIBM), University of Granada, Granada, Spain; Instituto de Investigación Biosanitaria ibs.GRANADA, Granada, Spain; Department of Analytical Chemistry, University of Granada, Granada, Spain
18 shared publications - Oscar Ballesteros
Research Group of Analytical Chemistry and Life Sciences, Department of Analytical Chemistry, University of Granada, Campus of Fuentenueva, E-18071 Granada, Spain
8 shared publications A. Navalón
Research Group of Analytical Chemistry and Life Sciences, Department of Analytical Chemistry, University of Granada, Campus of Fuentenueva, E-18071 Granada, Spain
6 shared publicationsI. Jiménez-Díaz
Research Group of Analytical Chemistry and Life Sciences, Department of Analytical Chemistry, University of Granada, Campus of Fuentenueva, E-18071 Granada, Spain; Instituto de Investigación Biosanitaria ibs., Granada E-18012, Spain
5 shared publications- Jean-Michel Kauffmann
Laboratory of Instrumental Analysis and Bioelectrochemistry, Faculty of Pharmacy, Université Libre de Bruxelles, Boulevard du Triomphe, Campus Plaine, CP 205/06, 1050 Brussels, Belgium
4 shared publications - María Teresa García-Córcoles
Abbott Nutrition, Research and Development, Granada, Spain
4 shared publications
Latest Publications
- Top Cited Papers
Analytical methods for the determination of emerging contaminants in sewage sludge samples. A review
- 24 October 2018
- Published by Bentham Science Publishers Ltd. in Current Medicinal Chemistry
- Vol. 25 (33) , 4050-4065
Electrochemical Detectors in Liquid Chromatography: Recent Trends in Pharmaceutical and Biomedical Analysis
Liquid chromatography (LC) coupled to an electrochemical (EC) detector is a complementary analytical tool compared to LC coupled with optical or mass spectrometry detectors (LC-MS). LC-EC can be applied to the determination of molecules difficult to be analyzed by other commercially available detectors. New EC detector design and new working electrode material have extended the scope of application in the field of pharmaceutical compounds analysis. Combining EC with LC-MS offers additional advantages compared to optical detectors in terms of drug stability and drug metabolism mimicry studies. Selected literature devoted to pharmacologically active compounds in their dosage forms, herbal drugs in natural products, drug residues in feed and/or in biological samples are reported in this review.
- 24 October 2018
- Published by Bentham Science Publishers Ltd. in Current Medicinal Chemistry
- Vol. 25 (33) , 4050-4065
Electrochemical Detectors in Liquid Chromatography: Recent Trends in Pharmaceutical and Biomedical Analysis
Liquid chromatography (LC) coupled to an electrochemical (EC) detector is a complementary analytical tool compared to LC coupled with optical or mass spectrometry detectors (LC-MS). LC-EC can be applied to the determination of molecules difficult to be analyzed by other commercially available detectors. New EC detector design and new working electrode material have extended the scope of application in the field of pharmaceutical compounds analysis. Combining EC with LC-MS offers additional advantages compared to optical detectors in terms of drug stability and drug metabolism mimicry studies. Selected literature devoted to pharmacologically active compounds in their dosage forms, herbal drugs in natural products, drug residues in feed and/or in biological samples are reported in this review.
- Open Access
- 15 October 2018
- Published by MDPI AG in Antioxidants
- Vol. 7 (10) , 143
Determination of Three Main Chlorogenic Acids in Water Extracts of Coffee Leaves by Liquid Chromatography Coupled to an Electrochemical Detector
Coffee is a beverage widely consumed in the world. The coffee species most commercialized worldwide are Arabica (Coffea arabica) and Robusta (Coffea canephora). Roasted coffee beans are the most used, but coffee leaves are also consumed as infusion in several countries for traditional medicinal purposes. They contain several interesting phenolic antioxidant compounds mainly belonging to chlorogenic acids (CGAs). In the present work, a liquid chromatography-electrochemical detection (LC-EC) method was developed for the determination of three main chlorogenic acid isomers, namely 3-, 4-, and 5-caffeoylquinic acids (CQA), in coffee leaves aqueous extracts. Samples from eight coffee species, namely; Coffea arabica, Coffea canephora, Coffea liberica, Coffea humilis, Coffea mannii, Coffea charrieriana, Coffea anthonyi, and Coffea liberica var. liberica, were grown and collected in tropical greenhouses. Linearity of the calibration graphs was observed in the range from the limit of quantification to 1.0 × 10−5 M, with R2 equal to 99.9% in all cases. High sensitivity was achieved with a limit of detection of 1.0 × 10−8 M for 3-CQA and 5-CQA (i.e., 3.5 µg/L) and 2.0 × 10−8 M for 4-CQA (i.e., 7.1 µg/L). The chromatographic profile of the samples harvested for each Coffea species was studied comparatively. Obtained raw data were pretreated for baseline variations and shifts in retention times between the chromatographic profiles. Principal Component Analysis (PCA) was applied to the pretreated data. According to the results, three clusters of Coffea species were found. In the water sample extracts, 5-CQA appeared to be the major isomer, and some species contained a very low amount of CQAs. Fluctuations were observed depending on the Coffea species and harvesting period. Significant differences between January and July were noticed regarding CQAs content. The species with the best CQAs/caffeine ratio was identified. The LC-EC data were validated by liquid chromatography-high resolution mass spectrometry (LC-HRMS).
- 15 October 2018
- Published by MDPI AG in Antioxidants
- Vol. 7 (10) , 143
Open AccessDetermination of Three Main Chlorogenic Acids in Water Extracts of Coffee Leaves by Liquid Chromatography Coupled to an Electrochemical Detector
Coffee is a beverage widely consumed in the world. The coffee species most commercialized worldwide are Arabica (Coffea arabica) and Robusta (Coffea canephora). Roasted coffee beans are the most used, but coffee leaves are also consumed as infusion in several countries for traditional medicinal purposes. They contain several interesting phenolic antioxidant compounds mainly belonging to chlorogenic acids (CGAs). In the present work, a liquid chromatography-electrochemical detection (LC-EC) method was developed for the determination of three main chlorogenic acid isomers, namely 3-, 4-, and 5-caffeoylquinic acids (CQA), in coffee leaves aqueous extracts. Samples from eight coffee species, namely; Coffea arabica, Coffea canephora, Coffea liberica, Coffea humilis, Coffea mannii, Coffea charrieriana, Coffea anthonyi, and Coffea liberica var. liberica, were grown and collected in tropical greenhouses. Linearity of the calibration graphs was observed in the range from the limit of quantification to 1.0 × 10−5 M, with R2 equal to 99.9% in all cases. High sensitivity was achieved with a limit of detection of 1.0 × 10−8 M for 3-CQA and 5-CQA (i.e., 3.5 µg/L) and 2.0 × 10−8 M for 4-CQA (i.e., 7.1 µg/L). The chromatographic profile of the samples harvested for each Coffea species was studied comparatively. Obtained raw data were pretreated for baseline variations and shifts in retention times between the chromatographic profiles. Principal Component Analysis (PCA) was applied to the pretreated data. According to the results, three clusters of Coffea species were found. In the water sample extracts, 5-CQA appeared to be the major isomer, and some species contained a very low amount of CQAs. Fluctuations were observed depending on the Coffea species and harvesting period. Significant differences between January and July were noticed regarding CQAs content. The species with the best CQAs/caffeine ratio was identified. The LC-EC data were validated by liquid chromatography-high resolution mass spectrometry (LC-HRMS).
- 4 October 2018
- Published by Taylor & Francis in Critical Reviews in Analytical Chemistry
- Vol. 49 (2) , 160-186
Chromatographic Methods for the Determination of Emerging Contaminants in Natural Water and Wastewater Samples: A Review
This review is devoted to analytical methods published in the scientific literature in the last 10 years for the determination of emerging contaminants in aquatic media. The article is mainly focused on sample preparation and on instrumental techniques most used for the detection and quantification of the analytes of interest. The sample preparation techniques include classical liquid-liquid extraction and solid-phase extraction, but also recent microextraction techniques such as solid-phase microextraction, stir-bar sorptive extraction, dispersive liquid-liquid microextraction, ultrasound-assisted emulsification microextraction, or microextraction by packed sorbent. Most studies focus on minimizing the number of analysis steps and on the use of the lowest amount of solvents in the sample treatment step. Liquid chromatography and gas chromatography mainly coupled to tandem mass spectrometry are usually the employed analytical techniques. A large number of multiresidue methods are being developed for the determination of several families of these compounds with only one extraction step to minimize sample handling and treatment.
- 4 October 2018
- Published by Taylor & Francis in Critical Reviews in Analytical Chemistry
- Vol. 49 (2) , 160-186
Chromatographic Methods for the Determination of Emerging Contaminants in Natural Water and Wastewater Samples: A Review
This review is devoted to analytical methods published in the scientific literature in the last 10 years for the determination of emerging contaminants in aquatic media. The article is mainly focused on sample preparation and on instrumental techniques most used for the detection and quantification of the analytes of interest. The sample preparation techniques include classical liquid-liquid extraction and solid-phase extraction, but also recent microextraction techniques such as solid-phase microextraction, stir-bar sorptive extraction, dispersive liquid-liquid microextraction, ultrasound-assisted emulsification microextraction, or microextraction by packed sorbent. Most studies focus on minimizing the number of analysis steps and on the use of the lowest amount of solvents in the sample treatment step. Liquid chromatography and gas chromatography mainly coupled to tandem mass spectrometry are usually the employed analytical techniques. A large number of multiresidue methods are being developed for the determination of several families of these compounds with only one extraction step to minimize sample handling and treatment.
- 21 February 2018
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 35 (6) , 1127-1138
Determination of quinolone residues in raw cow milk. Application of polar stir-bars and ultra-high performance liquid chromatography–tandem mass spectrometry
Seventeen quinolone antibiotics were determined in cows’ milk. A method of high sensitivity, selectivity and accuracy was developed. Accuracy (trueness and precision), linearity, sensitivity, selectivity, decision limit and detection capability were established following the recommendations of the Commission Decision 2002/657/EC and the Food and Drug Administration (FDA) guideline. The use of polar stir-bar sorptive extraction (SBSE) prior to UHPLC-MS/MS analysis is proposed. The variables that affect SBSE were optimised using multivariate optimisation strategies. The ionic strength, the extraction time and the sample volume were studied. pH and stir-bar coating (polydimethylsiloxane, PDMS, and polyethyleneglycol modified silicone, PEG) were studied. PEG showed the best extraction yield at pH 6. For validation, a matrix-matched calibration and a recovery assay were carried out. Limits of quantification from 0.5 μg kg−1 for nalidixic acid, flumequine and piromidic acid, to 4.0 μg kg−1 for sarafloxacin were calculated. The precision (%, RSD) was lower than 15% for all antibiotics. Recoveries in fortified samples were between 88 and 114%.
- 21 February 2018
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 35 (6) , 1127-1138
Determination of quinolone residues in raw cow milk. Application of polar stir-bars and ultra-high performance liquid chromatography–tandem mass spectrometry
Seventeen quinolone antibiotics were determined in cows’ milk. A method of high sensitivity, selectivity and accuracy was developed. Accuracy (trueness and precision), linearity, sensitivity, selectivity, decision limit and detection capability were established following the recommendations of the Commission Decision 2002/657/EC and the Food and Drug Administration (FDA) guideline. The use of polar stir-bar sorptive extraction (SBSE) prior to UHPLC-MS/MS analysis is proposed. The variables that affect SBSE were optimised using multivariate optimisation strategies. The ionic strength, the extraction time and the sample volume were studied. pH and stir-bar coating (polydimethylsiloxane, PDMS, and polyethyleneglycol modified silicone, PEG) were studied. PEG showed the best extraction yield at pH 6. For validation, a matrix-matched calibration and a recovery assay were carried out. Limits of quantification from 0.5 μg kg−1 for nalidixic acid, flumequine and piromidic acid, to 4.0 μg kg−1 for sarafloxacin were calculated. The precision (%, RSD) was lower than 15% for all antibiotics. Recoveries in fortified samples were between 88 and 114%.
- 6 November 2017
- Published by Wiley in Electroanalysis
- Vol. 30 (7) , 1293-1302
Electrochemical Studies of Ethoxyquin and its Determination in Salmon Samples by Flow Injection Analysis with an Amperometric Dual Detector
Ethoxyquin (EQ) is an antioxidant widely used in the food industry. Some concerns for human health have been reported since its utilization in animal feed may lead to residues in human food such as salmon samples. This work aimed to investigate the electrochemical behavior of EQ and its major oxidation products namely a dimer of EQ (EQDM) and ethoxyquin quinone imine (EQI) by cyclic voltammetry (CV) at a carbon screen printed electrode (cSPE). The stability of these products and their reactivity against glutathione (GSH) were also studied. Oxidized products and thiol adducts were identified by a microelectrolysis of an EQ solution onto a cSPE in the absence and in the presence of GSH. The products were analyzed off‐line, by liquid chromatography coupled to a mass spectrometer (LC‐MS). One of the generated product (EQI) was shown to be highly reactive towards GSH. Based on the redox pattern of EQ, a flow injection analysis with a dual cSPE was developed in order to detect in a rapid manner EQ in salmon samples. Since matrix effects were observed, matrix‐matched calibration curves with spiked samples were built. A linear response was obtained between 20–100 μM and a limit of detection (LOD) of 7.5 μM (8.2 mg/kg of salmon). Trueness was assessed with recovery assays at three levels of concentration. The recovery was close to 100 %. Precision was determined as RSD (%) with values lower than 6 % in all cases.
- 6 November 2017
- Published by Wiley in Electroanalysis
- Vol. 30 (7) , 1293-1302
Electrochemical Studies of Ethoxyquin and its Determination in Salmon Samples by Flow Injection Analysis with an Amperometric Dual Detector
Ethoxyquin (EQ) is an antioxidant widely used in the food industry. Some concerns for human health have been reported since its utilization in animal feed may lead to residues in human food such as salmon samples. This work aimed to investigate the electrochemical behavior of EQ and its major oxidation products namely a dimer of EQ (EQDM) and ethoxyquin quinone imine (EQI) by cyclic voltammetry (CV) at a carbon screen printed electrode (cSPE). The stability of these products and their reactivity against glutathione (GSH) were also studied. Oxidized products and thiol adducts were identified by a microelectrolysis of an EQ solution onto a cSPE in the absence and in the presence of GSH. The products were analyzed off‐line, by liquid chromatography coupled to a mass spectrometer (LC‐MS). One of the generated product (EQI) was shown to be highly reactive towards GSH. Based on the redox pattern of EQ, a flow injection analysis with a dual cSPE was developed in order to detect in a rapid manner EQ in salmon samples. Since matrix effects were observed, matrix‐matched calibration curves with spiked samples were built. A linear response was obtained between 20–100 μM and a limit of detection (LOD) of 7.5 μM (8.2 mg/kg of salmon). Trueness was assessed with recovery assays at three levels of concentration. The recovery was close to 100 %. Precision was determined as RSD (%) with values lower than 6 % in all cases.
- 1 March 2017
- Published by Elsevier in Chemosphere
- Vol. 171, 661-670
Sorption, degradation and transport phenomena of alcohol ethoxysulfates in agricultural soils. Laboratory studies
- 1 March 2017
- Published by Elsevier in Chemosphere
- Vol. 171, 661-670
Sorption, degradation and transport phenomena of alcohol ethoxysulfates in agricultural soils. Laboratory studies
- 1 February 2017
- Published by Elsevier in Chemosphere
- Vol. 168, 676-684
Biomonitoring of 21 endocrine disrupting chemicals in human hair samples using ultra-high performance liquid chromatography–tandem mass spectrometry
- 1 February 2017
- Published by Elsevier in Chemosphere
- Vol. 168, 676-684
Biomonitoring of 21 endocrine disrupting chemicals in human hair samples using ultra-high performance liquid chromatography–tandem mass spectrometry