NDNicolas Dubost

Nicolas Dubost

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nicolas Dubost has a total of 155 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    First light for the GRAVITY+ Adaptive Optics: Extreme adaptive optics for the Very Large Telescope Interferometer

    by R. Abuter, F. Allouche, C. Bailet, M. Benisty, A. Berdeu, J.-P. Berger, P. Berio, A. Bigioli, C. Blanchard, O. Boebion, et al.

    GRAVITY+ improves by orders of magnitude the sensitivity, sky-coverage, and contrast of the Very Large Telescope Interferometer (VLTI). A central part of this project is the development of Gravity Plus Adaptive Optics (GPAO), a dedicated high-order and laser-guide star adaptive optics (AO) system for VLTI. GPAO consists of four state-of-the-art AO systems that equip all 8 m class Unit Telescopes (UTs) for the wavefront correction of the VLTI instruments. It offers both visible and infrared natural guide star (NGS) and laser guide star (LGS) operations. The paper presents the design, operations, and performances of GPAO. We illustrate the improvement brought by GPAO with interferometric observations obtained during the commissioning of the NGS mode at the end of 2024. These science results include the first optical interferometry observations of a redshift z ~ 4 quasar, the spectroscopy of a cool brown-dwarf with magnitude K ~ 21.0, the first observations of a Class I young star with GRAVITY, and the first sub-micro arcsecond differential astrometry in the optical. Together with the entire GRAVITY+ project, the implementation of GPAO is a true paradigm shift for observing the optical Universe at very high angular resolution.


  • Open Access

    UVA Hyperspectral Light-Sheet Microscopy for Volumetric Metabolic Imaging: Application to Preimplantation Embryo Development

    by Josephine Morizet, Darren Chow, Philip Wijesinghe, Erik Schartner, George Dwapanyin, Nicolas Dubost, Graham D. Bruce, Ellen Anckaert, Kylie Dunning, Kishan Dholakia

    Cellular metabolism is a key regulator of energetics, cell growth, regeneration, and homeostasis. Spatially mapping the heterogeneity of cellular metabolic activity is of great importance for unraveling the overall cell and tissue health. In this regard, imaging the endogenous metabolic cofactors, nicotinamide adenine dinucleotide (phosphate) (NAD(P)H) and flavin adenine dinucleotide (FAD), with subcellular resolution and in a noninvasive manner would be useful to determine tissue and cell viability in a clinical environment, but practical use is limited by current imaging techniques. In this paper, we demonstrate the use of phasor-based hyperspectral light-sheet (HS-LS) microscopy using a single UVA excitation wavelength as a route to mapping metabolism in three dimensions. We show that excitation solely at a UVA wavelength of 375 nm can simultaneously excite NAD(P)H and FAD autofluorescence, while their relative contributions can be readily quantified using a hardware-based spectral phasor analysis. We demonstrate the potential of our HS-LS system by capturing dynamic changes in metabolic activity during preimplantation embryo development. To validate our approach, we delineate metabolic changes during preimplantation embryo development from volumetric maps of metabolic activity. Importantly, our approach overcomes the need for multiple excitation wavelengths, two-photon imaging, or significant postprocessing of data, paving the way toward clinical translation, such as in situ, noninvasive assessment of embryo viability.


  • Open Access

    UVA hyperspectral light-sheet microscopy for volumetric metabolic imaging: application to pre-implantation embryo development

    by Josephine Morizet, Darren Chow, Philip Wijesinghe, Erik Schartner, G. Dwapanyin, Nicolas Dubost, Graham D Bruce, Ellen Anckaert, Kylie Dunning, Kishan Dholakia

    Cellular metabolism is a key regulator of energetics, cell growth, regeneration and homeostasis. Spatially mapping the heterogeneity of cellular metabolic activity is of great importance for unraveling the overall cell and tissue health. In this regard, imaging the endogenous metabolic co-factors NAD(P)H and FAD with sub-cellular resolution and in a non-invasive manner would be useful to determine tissue and cell viability in a clinical environment, but practical use is limited by current imaging techniques. In this article, we demonstrate the use of phasor-based hyperspectral light-sheet (HS-LS) microscopy using a single UVA excitation wavelength as a route to mapping metabolism in three dimensions. We show that excitation solely at a UVA wavelength of 375 nm can simultaneously excite NAD(P)H and FAD autofluorescence, while their relative contributions can be readily quantified using a hardware-based spectral phasor analysis. We demonstrate the potential of our HS-LS system by capturing dynamic changes in metabolic activity during pre-implantation embryo development. To validate our approach, we delineate metabolic changes during pre-implantation embryo development from volumetric maps of metabolic activity. Importantly, our approach overcomes the need for multiple excitation wavelengths, two-photon imaging or significant post-processing of data, paving the way towards clinical translation, such as in situ, non-invasive assessment of embryo viability.

  • Open Access

    Investigation of refractive index dynamics during in vitro embryo development using off-axis digital holographic microscopy

    by George O. Dwapanyin, Darren J. X. Chow, Tiffany C. Y. Tan, Nicolas S. Dubost, Josephine M. Morizet, Kylie R. Dunning, Kishan Dholakia

    Embryo quality is a crucial factor affecting live birth outcomes. However, an accurate diagnostic for embryo quality remains elusive in the in vitro fertilization clinic. Determining physical parameters of the embryo may offer key information for this purpose. Here, we demonstrate that digital holographic microscopy (DHM) can rapidly and non-invasively assess the refractive index of mouse embryos. Murine embryos were cultured in either low- or high-lipid containing media and digital holograms recorded at various stages of development. The phase of the recorded hologram was numerically retrieved, from which the refractive index of the embryo was calculated. We showed that DHM can detect spatio-temporal changes in refractive index during embryo development that are reflective of its lipid content. As accumulation of intracellular lipid is known to compromise embryo health, DHM may prove beneficial in developing an accurate, non-invasive, multimodal diagnostic.


  • Open Access

    Investigation of refractive index dynamics during embryo development using digital holographic microscopy

    by George O. Dwapanyin, Darren J. X. Chow, Tiffany C. Y. Tan, Nicolas S. Dubost, Josephine M. Morizet, Kylie R. Dunning, Kishan Dholakia

    Embryo quality is a crucial factor affecting live birth outcomes. However, an accurate diagnostic for embryo quality remains elusive in the in vitro fertilization clinic. Determining physical parameters of the embryo may offer key information for this purpose. Here, we demonstrate that digital holographic microscopy (DHM) can rapidly and non-invasively assess the refractive index of mouse embryos. We showed that DHM can detect spatio-temporal changes in refractive index during embryo development that are reflective of its lipid content. As accumulation of intracellular lipid is known to compromise embryo health, DHM may prove beneficial in developing an accurate, non-invasive, multimodal diagnostic.


  • Open Access

    Concept validation of a high dynamic range point-diffraction interferometer for wavefront sensing in adaptive optics

    by Nicolás Dubost, Nazim Ali Bharmal, Marc Dubbeldam, Richard M. Myers

    The direct detection and imaging of exoplanets requires the use of high-contrast adaptive optics (AO). In these systems quasi-static aberrations need to be highly corrected and calibrated. To achieve this, the pupil-modulated point-diffraction interferometer (m-PDI) was presented in an earlier paper. This present paper focuses on m-PDI concept validation through three experiments. First, the instrument’s accuracy and dynamic range are characterized by measuring the spatial transfer function at all spatial frequencies and at different amplitudes. Then, using visible monochromatic light, an AO control loop is closed on the system’s systematic bias to test for precision and completeness. In a central section of the pupil with 72% of the total radius, the residual error is 7.7 nm rms. Finally, the control loop is run using polychromatic light with a spectral FWHM of 77 nm around the R-band. The control loop shows no drop in performance with respect to the monochromatic case, reaching a final Strehl ratio larger than 0.7.


  • Open Access

    Calibration of quasi-static aberrations in high-contrast astronomical adaptive optics with a pupil-modulated point-diffraction interferometer

    by Nicolás Dubost, Nazim Ali Bharmal, Richard M. Myers

    The direct detection and imaging of exoplanets requires the use of high-contrast adaptive optics (AO). In these systems quasi-static aberrations need to be highly corrected and calibrated. In order to achieve this, a high-sensitivity wavefront sensor, the pupil-modulated point-diffraction interferometer (m-PDI), is presented. This sensor modulates and retrieves both the phase and the amplitude of an incoming electric field. The theory behind the wavefront reconstruction, the visibility of fringes, chromatic effects and noise propagation are developed. Results show this interferometer has a wide chromatic bandwidth. For a bandwidth of Δλ = 50% in units of central wavelength, the visibility of fringes and the response of the WFS to low and high-order aberrations are almost unaffected with respect to the monochromatic case. The WFS is, in contrast, very sensitive to variations in the size of its pinhole. The size of the pinhole is shown to affect the sensor’s linearity, the dynamic range and the amount of noise. Larger pinholes make the sensor less sensitive to low-order aberrations, but in turn also decrease the effects of misalignments.