Ning Chien
Ning Chien has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Yeun-Chung Chang
Institute of Biomedical Engineering, National Taiwan University, Taipei 10617, Taiwan
5 shared publications - Wei-Chun Ko
Department of Medical Imaging, National Taiwan University Hospital, Taipei, Taiwan
3 shared publications - Yao-Hui Tseng
Department of Medical Imaging, National Taiwan University Hospital, Taipei, Taiwan
3 shared publications - Yee-Fan Lee
Department of Medical Imaging, National Taiwan University Hospital, Taipei, Taiwan
3 shared publications - Jang-Ming Lee
Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan
2 shared publications - Jin-Shing Chen
National Taiwan University Hospital
2 shared publications
Latest Publications
- 16 September 2025
- Published by Elsevier in European Journal of Radiology
- Vol. 193, 112419
Deep learning based multi-shot breast diffusion MRI: Improving imaging quality and reduced distortion
- 16 September 2025
- Published by Elsevier in European Journal of Radiology
- Vol. 193, 112419
Deep learning based multi-shot breast diffusion MRI: Improving imaging quality and reduced distortion
- 17 June 2020
- Published by Springer Nature in European Radiology
- Vol. 30 (11) , 6080-6088
Clip migration after stereotactic vacuum-assisted breast biopsy with the patient in the decubitus position
Objective To investigate the factors contributing to clip migration in stereotactic vacuum-assisted biopsy (VAB) of the breast using an upright unit with the patient in the decubitus position. Methods This retrospective study included 176 women with microcalcifications on mammograms undergoing stereotactic VAB with clip marking for analysis. The prebiopsy mammograms, stereotactic VAB images, immediate postbiopsy mammograms, and follow-up mammograms were reviewed. All VAB procedures were performed using an add-on upright unit with the patient in the decubitus position. The clip-to-lesion distance on the orthogonal view (craniocaudal view) on immediate postbiopsy mammography was estimated for each biopsy. Two cutoff points of clip-to-lesion distance of > 1 cm or > 2 cm were set for clip migration. The possible factors for clip migration based on clinical and imaging findings were then analyzed by Fisher’s exact test. Results When the cutoff for clip migration was set at > 1 cm, thin breast (p = 0.013) and more superficial lesion (lesion closer to the skin along the line perpendicular to the posterior nipple line, p = 0.004) were associated with clip migration. When the cutoff was set at > 2 cm, thin breast (p = 0.019), high specimen number (p = 0.030), and posterior depth (p = 0.021) were associated with clip migration. Conclusions Thin breasts, superficial lesion location, posterior lesion depth, and high specimen number were the factors associated with clip migration. Key Points • We reported clip migration after ST VAB using an upright unit with the patient in the decubitus position. • The occurrence of clinically significant clip migration (> 2 cm) in our study was 8.5%, which was within the range of the other reports with the patient undergoing ST VAB in the prone position. • Thin breasts, high specimen number, and more posterior depth were the factors associated with significant clip migration.
- 17 June 2020
- Published by Springer Nature in European Radiology
- Vol. 30 (11) , 6080-6088
Clip migration after stereotactic vacuum-assisted breast biopsy with the patient in the decubitus position
Objective To investigate the factors contributing to clip migration in stereotactic vacuum-assisted biopsy (VAB) of the breast using an upright unit with the patient in the decubitus position. Methods This retrospective study included 176 women with microcalcifications on mammograms undergoing stereotactic VAB with clip marking for analysis. The prebiopsy mammograms, stereotactic VAB images, immediate postbiopsy mammograms, and follow-up mammograms were reviewed. All VAB procedures were performed using an add-on upright unit with the patient in the decubitus position. The clip-to-lesion distance on the orthogonal view (craniocaudal view) on immediate postbiopsy mammography was estimated for each biopsy. Two cutoff points of clip-to-lesion distance of > 1 cm or > 2 cm were set for clip migration. The possible factors for clip migration based on clinical and imaging findings were then analyzed by Fisher’s exact test. Results When the cutoff for clip migration was set at > 1 cm, thin breast (p = 0.013) and more superficial lesion (lesion closer to the skin along the line perpendicular to the posterior nipple line, p = 0.004) were associated with clip migration. When the cutoff was set at > 2 cm, thin breast (p = 0.019), high specimen number (p = 0.030), and posterior depth (p = 0.021) were associated with clip migration. Conclusions Thin breasts, superficial lesion location, posterior lesion depth, and high specimen number were the factors associated with clip migration. Key Points • We reported clip migration after ST VAB using an upright unit with the patient in the decubitus position. • The occurrence of clinically significant clip migration (> 2 cm) in our study was 8.5%, which was within the range of the other reports with the patient undergoing ST VAB in the prone position. • Thin breasts, high specimen number, and more posterior depth were the factors associated with significant clip migration.
- Open Access
- 1 January 2020
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 21 (2) , 119-124
The Third Asian Radiology Forum: Screening Programs in Asia
Chien N, et al. Korean J Radiol. 2020 Jan;21:e5. https://doi.org/10.3348/kjr.2019.0488
- 1 January 2020
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 21 (2) , 119-124
Open AccessThe Third Asian Radiology Forum: Screening Programs in Asia
Chien N, et al. Korean J Radiol. 2020 Jan;21:e5. https://doi.org/10.3348/kjr.2019.0488
- Open Access
- 1 October 2016
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 8 (S9) , S659-S665
CT-guided percutaneous microwave ablation of pulmonary malignant tumors
Background: Microwave ablation (MWA) of lung tumors is a new approach for local tumor control. The purpose of this retrospective study was to evaluate the preliminary results of safety and efficacy of MWA with a dynamic frequency range (902–928 MHz) and power (10–32 W) for local tumor control of thoracic malignancies. Methods: From December 1, 2013 to February 1, 2016, there were total 32 lung tumors among 15 patients (7 men, 8 women, age range 43–82 years, mean 57.8±11.1 years of age) receiving MWA of thoracic neoplasms, including lung adenocarcinoma (n=5), metastatic colorectal cancer (n=7), invasive thymoma (n=1), metastatic uterine leiomyosarcoma (n=1), and metastatic ampullary carcinoma (n=1). Mean tumor size was 13.5 mm (range, 3.0–32.0 mm). The mean sequential ablation during each MWA was 2.3±1.1 times (range, 1–5 times). The outcomes of ablation were evaluated by follow-up computed tomography (CT) scans and the complications were assessed by medical records and CT scan after ablation. Results: The mean follow-up interval of each tumor was 446.8 days (range, 196–902 days). Local tumor recurrence was found in 5 of the 32 tumors resulting in a local control rate 84.4%. No MWA-related mortality was noted. After MWA, the incidence of pneumothorax was 37.5% (12/32). Only one patient with pneumothorax required air evacuation. Third-degree skin burn adjacent to the entry site occurred in one patient and required debridement and closure with flap. Conclusions: After appropriate patient selection, MWA with a dynamic frequency range (902–928 MHz) and power (10–32 W) is an effective and safe procedure for local tumor control of recurrent and metastatic lung tumors.
- 1 October 2016
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 8 (S9) , S659-S665
Open AccessCT-guided percutaneous microwave ablation of pulmonary malignant tumors
Background: Microwave ablation (MWA) of lung tumors is a new approach for local tumor control. The purpose of this retrospective study was to evaluate the preliminary results of safety and efficacy of MWA with a dynamic frequency range (902–928 MHz) and power (10–32 W) for local tumor control of thoracic malignancies. Methods: From December 1, 2013 to February 1, 2016, there were total 32 lung tumors among 15 patients (7 men, 8 women, age range 43–82 years, mean 57.8±11.1 years of age) receiving MWA of thoracic neoplasms, including lung adenocarcinoma (n=5), metastatic colorectal cancer (n=7), invasive thymoma (n=1), metastatic uterine leiomyosarcoma (n=1), and metastatic ampullary carcinoma (n=1). Mean tumor size was 13.5 mm (range, 3.0–32.0 mm). The mean sequential ablation during each MWA was 2.3±1.1 times (range, 1–5 times). The outcomes of ablation were evaluated by follow-up computed tomography (CT) scans and the complications were assessed by medical records and CT scan after ablation. Results: The mean follow-up interval of each tumor was 446.8 days (range, 196–902 days). Local tumor recurrence was found in 5 of the 32 tumors resulting in a local control rate 84.4%. No MWA-related mortality was noted. After MWA, the incidence of pneumothorax was 37.5% (12/32). Only one patient with pneumothorax required air evacuation. Third-degree skin burn adjacent to the entry site occurred in one patient and required debridement and closure with flap. Conclusions: After appropriate patient selection, MWA with a dynamic frequency range (902–928 MHz) and power (10–32 W) is an effective and safe procedure for local tumor control of recurrent and metastatic lung tumors.
- 1 October 2016
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 8 (S9) , S666-S671
Preoperative computed tomography-guided dye injection to localize multiple lung nodules for video-assisted thoracoscopic surgery
Background: Preoperative computed tomography (CT)-guided localization of small lung nodules is important for accurate and efficient video-assisted thoracoscopic surgery (VATS). Resection of multiple small pulmonary nodules in one VATS procedure can aid in patient management. The aim of this study was to evaluate the usefulness of CT-guided Patent Blue V (PBV) dye localization in patients with multiple pulmonary nodules who underwent VATS. Methods: This retrospective study was conducted from January 2013 to December 2015. One hundred consecutive patients (59.9±10.5 years of age) with 217 nodules who underwent preoperative CT-guided PBV dye localization for multiple (2 to 4) nodules before VATS were enrolled. Results: The mean nodule size was 0.8±0.4 cm, with a mean depth from the pleura or fissure of 0.7±0.7 cm. The mean procedure duration was 50±20 minutes. The mean amount of injected PBV dye was 0.2±0.1 mL per nodule. The overall success rate was 99% by nodule. Failed localization of two nodules in two patients was due to poor dye visualization (n=1) and significant pneumothorax (n=1). Cases of hemorrhage (24%) were mild and asymptomatic, and none of the patients had hemoptysis. None of the cases of pneumothorax (40%) required chest tube placement before VATS. One (1%) patient developed anaphylaxis. The mean post-operative hospital stay was 6.4±4.4 days. Conclusions: CT-guided PBV dye localization for multiple small pulmonary nodules before VATS is a safe, feasible, and accurate method with high success rate. This approach makes it easy to perform multiple nodule resections during one VATS operation.
- 1 October 2016
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 8 (S9) , S666-S671
Preoperative computed tomography-guided dye injection to localize multiple lung nodules for video-assisted thoracoscopic surgery
Background: Preoperative computed tomography (CT)-guided localization of small lung nodules is important for accurate and efficient video-assisted thoracoscopic surgery (VATS). Resection of multiple small pulmonary nodules in one VATS procedure can aid in patient management. The aim of this study was to evaluate the usefulness of CT-guided Patent Blue V (PBV) dye localization in patients with multiple pulmonary nodules who underwent VATS. Methods: This retrospective study was conducted from January 2013 to December 2015. One hundred consecutive patients (59.9±10.5 years of age) with 217 nodules who underwent preoperative CT-guided PBV dye localization for multiple (2 to 4) nodules before VATS were enrolled. Results: The mean nodule size was 0.8±0.4 cm, with a mean depth from the pleura or fissure of 0.7±0.7 cm. The mean procedure duration was 50±20 minutes. The mean amount of injected PBV dye was 0.2±0.1 mL per nodule. The overall success rate was 99% by nodule. Failed localization of two nodules in two patients was due to poor dye visualization (n=1) and significant pneumothorax (n=1). Cases of hemorrhage (24%) were mild and asymptomatic, and none of the patients had hemoptysis. None of the cases of pneumothorax (40%) required chest tube placement before VATS. One (1%) patient developed anaphylaxis. The mean post-operative hospital stay was 6.4±4.4 days. Conclusions: CT-guided PBV dye localization for multiple small pulmonary nodules before VATS is a safe, feasible, and accurate method with high success rate. This approach makes it easy to perform multiple nodule resections during one VATS operation.
- Open Access
- 1 March 2016
- Vol. 32 (2) , 167-173
The Emerging Roles of Coronary Computed Tomographic Angiography: Acute Chest Pain Evaluation and Screening for Asymptomatic Individuals
Coronary computed tomographic angiography (CCTA) has been widely available since 2004. After that, the diagnostic accuracy of CCTA has been extensively validated with invasive coronary angiography for detection of coronary arterial stenosis. In this paper, we reviewed the updated evidence of the role of CCTA in both scenarios including acute chest pain and screening in asymptomatic adults.
- 1 March 2016
- Vol. 32 (2) , 167-173
Open AccessThe Emerging Roles of Coronary Computed Tomographic Angiography: Acute Chest Pain Evaluation and Screening for Asymptomatic Individuals
Coronary computed tomographic angiography (CCTA) has been widely available since 2004. After that, the diagnostic accuracy of CCTA has been extensively validated with invasive coronary angiography for detection of coronary arterial stenosis. In this paper, we reviewed the updated evidence of the role of CCTA in both scenarios including acute chest pain and screening in asymptomatic adults.