Jean-Philippe Martin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jean-Philippe Martin has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Serge Pierfederici
9 shared publicationsB. Davat
8 shared publications- Babak Nahid-Mobarakeh
McMaster Automotive Resource Centre, McMaster University, Hamilton, ON, Canada
6 shared publications Bernard Davat
Groupe de Recherche en Electronique et Electrotechnique de Nancy (GREEN) Université de Lorraine 2, avenue de la forêt de Haye, TSA 60604 54518 Vandoeuvre lés Nancy France
6 shared publicationsS. Pierfederici
6 shared publications- Serge Pierfederici
Université de Lorraine, CNRS, LEMTA
5 shared publications
Latest Publications
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 5396-5406
Large-Signal Stability Control for Multiple Cascaded Filter DC Microgrid Based on Modified IDA-PBC
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 5396-5406
Large-Signal Stability Control for Multiple Cascaded Filter DC Microgrid Based on Modified IDA-PBC
- 16 October 2025
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 241, 257-270
Novel singularity-free IDA-PBC design method for stable interconnection of boost converters
- 16 October 2025
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 241, 257-270
Novel singularity-free IDA-PBC design method for stable interconnection of boost converters
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (12) , 14224-14235
General Design Method of Modified Damping Assignment-PBC in Shipboard Evolutive Microgrids
Passivity based control (PBC) is an appealing solution to control power converters while ensuring the stability of more and more complex and modular electrical systems. However, the original interconnection and damping assignment-PBC (IDA-PBC) controller design method generates singularities in the control-variables leading to their saturation and spikes of current. This article highlights this nondesired phenomenon by applying the original IDA-PBC to the control of a boost converter. A novel controller design is then proposed to remove the singularities of the control-variables while preserving the proof of passivity of the whole controlled system. The proposed method introduces a new damping assignment approach to tune the performances of the system. This design can be applied to a specific subclass of port controlled Hamiltonian (PCH) systems which includes the average models of different converters. To highlight the generalization of the proposed method, it is applied to a 5th-order 2 kW 2-input modular three-level boost converter (MTL-BC), and validated experimentally. The advantage of the controller is presented for a microgrid system (MGS) application compared to other conventional control strategies and how it improves the stability margin in the presence of a constant power load (CPL).
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (12) , 14224-14235
General Design Method of Modified Damping Assignment-PBC in Shipboard Evolutive Microgrids
Passivity based control (PBC) is an appealing solution to control power converters while ensuring the stability of more and more complex and modular electrical systems. However, the original interconnection and damping assignment-PBC (IDA-PBC) controller design method generates singularities in the control-variables leading to their saturation and spikes of current. This article highlights this nondesired phenomenon by applying the original IDA-PBC to the control of a boost converter. A novel controller design is then proposed to remove the singularities of the control-variables while preserving the proof of passivity of the whole controlled system. The proposed method introduces a new damping assignment approach to tune the performances of the system. This design can be applied to a specific subclass of port controlled Hamiltonian (PCH) systems which includes the average models of different converters. To highlight the generalization of the proposed method, it is applied to a 5th-order 2 kW 2-input modular three-level boost converter (MTL-BC), and validated experimentally. The advantage of the controller is presented for a microgrid system (MGS) application compared to other conventional control strategies and how it improves the stability margin in the presence of a constant power load (CPL).
- 1 June 2021
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 184, 21-40
Series hybrid fuel cell/supercapacitor power source
- 1 June 2021
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 184, 21-40
Series hybrid fuel cell/supercapacitor power source
- Open Access
- 1 November 2015
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 8 (11) , 2195-2203
Estimation of the bifurcation point of a modulated‐hysteresis current‐controlled DC–DC boost converter: stability analysis and experimental verification
It is known that power electronic circuits such as DC–DC converters are rich in non‐linear phenomena. It is often necessary to determine when the system becomes unstable. The authors investigate a continuous‐time averaging model for a modulated‐hysteresis current controller. This model is applied to a boost converter working in continuous conduction mode to estimate the bifurcation point and to study the stability of the controlled system. This controller ensures a fixed‐switching frequency, a zero static error and high robustness properties of the system parameter variations. Simulation and experimental results are presented to validate the proposed approach.
- 1 November 2015
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 8 (11) , 2195-2203
Open AccessEstimation of the bifurcation point of a modulated‐hysteresis current‐controlled DC–DC boost converter: stability analysis and experimental verification
It is known that power electronic circuits such as DC–DC converters are rich in non‐linear phenomena. It is often necessary to determine when the system becomes unstable. The authors investigate a continuous‐time averaging model for a modulated‐hysteresis current controller. This model is applied to a boost converter working in continuous conduction mode to estimate the bifurcation point and to study the stability of the controlled system. This controller ensures a fixed‐switching frequency, a zero static error and high robustness properties of the system parameter variations. Simulation and experimental results are presented to validate the proposed approach.
- Top Cited Papers
- 9 July 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 62 (2) , 1047-1058
A PSO-Based Global MPPT Technique for Distributed PV Power Generation
Photovoltaic (PV) systems are one of the main actors in distributed power generation. In particular, in urban contexts, the PV generators can be subjected to mismatching phenomena due to the different orientation of the modules with respect to the sun rays or due to shadowing. In these cases, the maximum power point tracking (MPPT) function must be designed carefully. In this paper, architecture, including one dc/dc converter for each PV generator, is considered. The converters' output terminals are series connected to a high-voltage dc bus, where also a bidirectional dc/dc converter managing the power from/to a storage device is plugged. The functional constraints deriving from the dc/dc converters' connection, the mismatching phenomena, the MPPT capabilities of the inverter, connected with its input terminals at the dc bus, are taken into account in order to determine the best operating point of the system as a whole. The real-time constrained optimization problem is solved by using the particle swarm optimization method, which needs the knowledge of the actual current versus voltage curve of each PV generator. The practical impact of this need is also discussed in the paper. The feasibility and the performances of the proposed approach are experimentally validated by using a laboratory prototype.
- 9 July 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 62 (2) , 1047-1058
Top Cited PapersA PSO-Based Global MPPT Technique for Distributed PV Power Generation
Photovoltaic (PV) systems are one of the main actors in distributed power generation. In particular, in urban contexts, the PV generators can be subjected to mismatching phenomena due to the different orientation of the modules with respect to the sun rays or due to shadowing. In these cases, the maximum power point tracking (MPPT) function must be designed carefully. In this paper, architecture, including one dc/dc converter for each PV generator, is considered. The converters' output terminals are series connected to a high-voltage dc bus, where also a bidirectional dc/dc converter managing the power from/to a storage device is plugged. The functional constraints deriving from the dc/dc converters' connection, the mismatching phenomena, the MPPT capabilities of the inverter, connected with its input terminals at the dc bus, are taken into account in order to determine the best operating point of the system as a whole. The real-time constrained optimization problem is solved by using the particle swarm optimization method, which needs the knowledge of the actual current versus voltage curve of each PV generator. The practical impact of this need is also discussed in the paper. The feasibility and the performances of the proposed approach are experimentally validated by using a laboratory prototype.
- 8 July 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 51 (1) , 491-497
Control of a Hybrid Energy Source Comprising a Fuel Cell and Two Storage Devices Using Isolated Three-Port Bidirectional DC–DC Converters
This paper deals with a hybrid energy source consisting of a proton exchange membrane fuel cell, two storage devices, and a load. Generally, this type of source constitutes of nonisolated dc-dc converters. In order to have galvanic isolation for safety reasons and a high voltage ratio, we introduce another system based on the use of three-port isolated dc-dc converters. The storage device can be either a battery or a supercapacitor. This paper presents a control strategy for the hybrid source and includes a global efficiency analysis of power sharing between modules. The proposed system is validated through different simulation results. Additionally, some experimental results are given for the single module operation.
- 8 July 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 51 (1) , 491-497
Control of a Hybrid Energy Source Comprising a Fuel Cell and Two Storage Devices Using Isolated Three-Port Bidirectional DC–DC Converters
This paper deals with a hybrid energy source consisting of a proton exchange membrane fuel cell, two storage devices, and a load. Generally, this type of source constitutes of nonisolated dc-dc converters. In order to have galvanic isolation for safety reasons and a high voltage ratio, we introduce another system based on the use of three-port isolated dc-dc converters. The storage device can be either a battery or a supercapacitor. This paper presents a control strategy for the hybrid source and includes a global efficiency analysis of power sharing between modules. The proposed system is validated through different simulation results. Additionally, some experimental results are given for the single module operation.
- 19 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 63 (9) , 4178-4191
A Control Strategy for Electric Traction Systems Using a PM-Motor Fed by a Bidirectional $Z$-Source Inverter
This paper deals with a control method that adapts the dc bus voltage of electric traction systems using permanent-magnet synchronous machine (PMSM) fed by bidirectional Z-source inverter (ZSI) or other improved topologies. This control allows reducing both the overestimation of the dc bus voltage and losses in the inverter. The sliding-mode control (SMC) method is used to control the Z-source converter, whereas flatness-based control is proposed to drive the actuator and generate the peak dc bus voltage reference. Flatness-based control is chosen because the actuator transients are well mastered. Extra shoot-through zero inverter states are inserted by means of implemented algorithm on a space-vector-modulation (SVM) scheme. Different short-circuit strategies are studied and compared according to constraint criteria. Both simulation and experimental results are presented and discussed to validate the proposed voltage adaptation strategy and the improvement on global efficiency.
- 19 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 63 (9) , 4178-4191
A Control Strategy for Electric Traction Systems Using a PM-Motor Fed by a Bidirectional $Z$-Source Inverter
This paper deals with a control method that adapts the dc bus voltage of electric traction systems using permanent-magnet synchronous machine (PMSM) fed by bidirectional Z-source inverter (ZSI) or other improved topologies. This control allows reducing both the overestimation of the dc bus voltage and losses in the inverter. The sliding-mode control (SMC) method is used to control the Z-source converter, whereas flatness-based control is proposed to drive the actuator and generate the peak dc bus voltage reference. Flatness-based control is chosen because the actuator transients are well mastered. Extra shoot-through zero inverter states are inserted by means of implemented algorithm on a space-vector-modulation (SVM) scheme. Different short-circuit strategies are studied and compared according to constraint criteria. Both simulation and experimental results are presented and discussed to validate the proposed voltage adaptation strategy and the improvement on global efficiency.
- 9 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 2 (3) , 467-476
Comparison Criteria for Electric Traction System Using Z-Source/Quasi Z-Source Inverter and Conventional Architectures
This paper deals with objective criteria to compare conventional electric traction systems composed of a dc-dc boost converter, a voltage source inverter, and a permanent magnet synchronous machine with alternative topologies such as Z-source inverter (ZSI) or quasi Z-source inverter (QZSI). Rather focusing only on efficiencies issues, this paper deals with other relevant criteria. The stored energy in the systems is for instance linked with their passive elements weight, size, or cost. The currents rms values and the stepup voltage ratio are also considered. A complete losses evaluation is given and validated by both simulation and experimental results. The results show that the QZSI exhibits real advantages in terms of passive elements size since the stored energy during one operating cycle is lower than that for the conventional topologies.
- 9 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 2 (3) , 467-476
Comparison Criteria for Electric Traction System Using Z-Source/Quasi Z-Source Inverter and Conventional Architectures
This paper deals with objective criteria to compare conventional electric traction systems composed of a dc-dc boost converter, a voltage source inverter, and a permanent magnet synchronous machine with alternative topologies such as Z-source inverter (ZSI) or quasi Z-source inverter (QZSI). Rather focusing only on efficiencies issues, this paper deals with other relevant criteria. The stored energy in the systems is for instance linked with their passive elements weight, size, or cost. The currents rms values and the stepup voltage ratio are also considered. A complete losses evaluation is given and validated by both simulation and experimental results. The results show that the QZSI exhibits real advantages in terms of passive elements size since the stored energy during one operating cycle is lower than that for the conventional topologies.
- 1 May 2013
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 91, 262-273
Predicting the onset of bifurcation and stability study of a hybrid current controller for a boost converter
- 1 May 2013
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 91, 262-273
Predicting the onset of bifurcation and stability study of a hybrid current controller for a boost converter