Fabio Carli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Fabio Carli has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
- Carlo Banfi
Université Catholique de Louvain, Yvoir, Belgium
2 shared publications Claudio Carino
University of Pavia
2 shared publications- Marco Pasian
University of Pavia
2 shared publications - Maurizio Bozzi
University of Pavia, Pavia, Italy
2 shared publications S Salvi
2 shared publications- Stefano Nazari
Department of Surgery, IRCCS San Matteo, University of Pavia, Italy
2 shared publications
Latest Publications
- 3 September 2016
- Published by Springer Nature
- p. 131-141
Evolutionary Model for Synthetic Spectrum Compatible Accelerograms
- 3 September 2016
- Published by Springer Nature
- p. 131-141
Evolutionary Model for Synthetic Spectrum Compatible Accelerograms
- 28 August 2013
- Published by Civil-Comp, Ltd.
- Vol. 103
An Evolutionary Approach for the Synthesis of Spectrum Compatible and Site-Dependent Earthquake Accelerograms
- 28 August 2013
- Published by Civil-Comp, Ltd.
- Vol. 103
An Evolutionary Approach for the Synthesis of Spectrum Compatible and Site-Dependent Earthquake Accelerograms
- Open Access
- 1 April 2013
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 7 (6) , 391-398
Multiphysics design and experimental verification of a quad‐band dichroic mirror for deep space ground stations
This study presents the multi‐disciplinary approach used to study a quad‐band dichroic mirror to be installed in the European Space Agency deep space antennas. Traditional electromagnetic (EM) analyses based on a uniform plane wave incidence were augmented by advanced numerical techniques to investigate the impact of the dichroic mirror on the overall antenna performance. In addition, along with the EM design, a parallel study considering mechanical, thermal and power‐handling aspects allowed their impact on the EM behaviour of the dichroic mirror to be evaluated. This comprehensive study permitted an optimum design to be achieved for the dichroic mirror, which accounts for the actual operational conditions of the mirror itself when installed in the antenna. The device was manufactured and measured, verifying also the mechanical and thermal theoretical predictions, obtaining an excellent agreement between simulations and experimental results.
- 1 April 2013
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 7 (6) , 391-398
Open AccessMultiphysics design and experimental verification of a quad‐band dichroic mirror for deep space ground stations
This study presents the multi‐disciplinary approach used to study a quad‐band dichroic mirror to be installed in the European Space Agency deep space antennas. Traditional electromagnetic (EM) analyses based on a uniform plane wave incidence were augmented by advanced numerical techniques to investigate the impact of the dichroic mirror on the overall antenna performance. In addition, along with the EM design, a parallel study considering mechanical, thermal and power‐handling aspects allowed their impact on the EM behaviour of the dichroic mirror to be evaluated. This comprehensive study permitted an optimum design to be achieved for the dichroic mirror, which accounts for the actual operational conditions of the mirror itself when installed in the antenna. The device was manufactured and measured, verifying also the mechanical and thermal theoretical predictions, obtaining an excellent agreement between simulations and experimental results.
- 1 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 25-28
Multi-physics design and manufacturing of a quad-band frequency selective surface for space applications
This paper presents the multi-disciplinary approach used to study a quad-band frequency selective surface to be installed in the European Space Agency deep space antennas. The electromagnetic design is augmented by the reciprocal interaction with mechanical, thermal and power handling analyses that allow a comprehensive study able to meet the severe specifications required to this frequency selective surface. The device is manufactured and tested and an excellent agreement is achieved.
- 1 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 25-28
Multi-physics design and manufacturing of a quad-band frequency selective surface for space applications
This paper presents the multi-disciplinary approach used to study a quad-band frequency selective surface to be installed in the European Space Agency deep space antennas. The electromagnetic design is augmented by the reciprocal interaction with mechanical, thermal and power handling analyses that allow a comprehensive study able to meet the severe specifications required to this frequency selective surface. The device is manufactured and tested and an excellent agreement is achieved.
- 24 July 2009
- Published by Civil-Comp, Ltd.
Mechanical Model of Net Reinforced Blood Vessel
- 19 January 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (8) , 1349-1353
Validation of esophageal Doppler for noninvasive hemodynamic monitoring under pneumoperitoneum
Commonly used perioperative measurements of hemodynamics, such as Swan-Ganz catheter assessment, are invasive and may not be reliable under pneumoperitoneum. The purpose of this study was to validate the use of esophageal Doppler for noninvasive hemodynamic monitoring under pneumoperitoneum in an experimental pig model.
- 19 January 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (8) , 1349-1353
Validation of esophageal Doppler for noninvasive hemodynamic monitoring under pneumoperitoneum
Commonly used perioperative measurements of hemodynamics, such as Swan-Ganz catheter assessment, are invasive and may not be reliable under pneumoperitoneum. The purpose of this study was to validate the use of esophageal Doppler for noninvasive hemodynamic monitoring under pneumoperitoneum in an experimental pig model.
- 22 January 2004
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 48 (2) , 169-173
Effect of desflurane/remifentanil anaesthesia on glucose metabolism during surgery: a comparison with desflurane/epidural anaesthesia
Background: The aim of this study was to investigate the effect of general anaesthesia combined with remifentanil or epidural blockade on glucose metabolism during surgery.Methods: We randomly assigned patients undergoing elective colorectal surgery to receive either desflurane anaesthesia supplemented with intravenous remifentanil (n = 7) or desflurane anaesthesia supplemented with epidural bupivacaine (n = 7). Plasma concentrations of glucose, lactate, free fatty acids (FFA), insulin, glucagon and cortisol were measured before and after 2 h of surgery. Pre‐ and intraoperative whole body glucose production and glucose clearance, an indicator of glucose uptake, were determined by an isotope dilution technique using [6,6–2H2]glucose.Results: In both groups intraoperative glucose production ( P< 0.05) and uptake ( P< 0.05) decreased. Plasma glucose concentrations ( P< 0.05) increased during surgery but did not exceed the normal range (remifentanil group: 5.7 ± 0.7 mmol l−1, epidural group: 5.8 ± 0.4 mmol l−1). The plasma concentrations of lactate, FFA, insulin and glucagon remained unchanged during the operation. The plasma cortisol concentration in both groups increased intraoperatively (P< 0.05).Conclusion: Both desflurane/remifentanil and desflurane/epidural anaesthesia decrease the intraoperative rate of whole body glucose production, thereby attenuating the hyperglycaemic response to colorectal surgery.
- 22 January 2004
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 48 (2) , 169-173
Effect of desflurane/remifentanil anaesthesia on glucose metabolism during surgery: a comparison with desflurane/epidural anaesthesia
Background: The aim of this study was to investigate the effect of general anaesthesia combined with remifentanil or epidural blockade on glucose metabolism during surgery.Methods: We randomly assigned patients undergoing elective colorectal surgery to receive either desflurane anaesthesia supplemented with intravenous remifentanil (n = 7) or desflurane anaesthesia supplemented with epidural bupivacaine (n = 7). Plasma concentrations of glucose, lactate, free fatty acids (FFA), insulin, glucagon and cortisol were measured before and after 2 h of surgery. Pre‐ and intraoperative whole body glucose production and glucose clearance, an indicator of glucose uptake, were determined by an isotope dilution technique using [6,6–2H2]glucose.Results: In both groups intraoperative glucose production ( P< 0.05) and uptake ( P< 0.05) decreased. Plasma glucose concentrations ( P< 0.05) increased during surgery but did not exceed the normal range (remifentanil group: 5.7 ± 0.7 mmol l−1, epidural group: 5.8 ± 0.4 mmol l−1). The plasma concentrations of lactate, FFA, insulin and glucagon remained unchanged during the operation. The plasma cortisol concentration in both groups increased intraoperatively (P< 0.05).Conclusion: Both desflurane/remifentanil and desflurane/epidural anaesthesia decrease the intraoperative rate of whole body glucose production, thereby attenuating the hyperglycaemic response to colorectal surgery.
- 1 January 2003
- Published by ASME International
- p. 1-6
Polysilicon Failure Stress and Young’s Modulus Evaluation in MEMS Devices
The main object of the paper is the implementation of two different approaches for the estimation of the modulus of elasticity and of the failure strain/stress in micro machined structures manufactured of epitaxial polycrystalline silicon (15 μm thick film). The micro-test-structures are produced using a standard THELMA process becoming an integral part of a MEMS actuator of comb-finger type. The micro-motor is designed to develop electrostatic in plane forces of desired intensity when fed by suitable electric potential difference.
- 1 January 2003
- Published by ASME International
- p. 1-6
Polysilicon Failure Stress and Young’s Modulus Evaluation in MEMS Devices
The main object of the paper is the implementation of two different approaches for the estimation of the modulus of elasticity and of the failure strain/stress in micro machined structures manufactured of epitaxial polycrystalline silicon (15 μm thick film). The micro-test-structures are produced using a standard THELMA process becoming an integral part of a MEMS actuator of comb-finger type. The micro-motor is designed to develop electrostatic in plane forces of desired intensity when fed by suitable electric potential difference.
- 1 May 2000
- Published by Elsevier in Nuclear Physics B - Proceedings Supplements
- Vol. 85 (1-3) , 119-124
ICARUS 600 ton: A status report
- 1 May 2000
- Published by Elsevier in Nuclear Physics B - Proceedings Supplements
- Vol. 85 (1-3) , 119-124
ICARUS 600 ton: A status report
- 1 April 2000
- Vol. 41 (2) , 193-202
Patterns of systolic stress distribution on mitral valve anterior leaflet chordal apparatus. A structural mechanical theoretical analysis.
Increasing diffusion and complexity of mitral valve repair procedures may prompt an interest in the evaluation of the patterns of stress distribution on the chords, which are, from the structural mechanical point of view, the weakest element of valve apparatus. This theoretical analysis concentrates in particular on the mitral valve anterior leaflet. As is known, the vast majority of the chordae are attached to the anterior leaflet within the coaptation area; during systole they are then necessarily parallel, aligned along the same plane as that of the leaflets' coaptation surface, to which they are attached; moreover the thickness of the chordae increases significantly from the marginal chordae to the more central ones. In normal conditions during systole the progressively wider coaptation surface causes the increasing stress to be supported by an increasing number of progressively thicker chords, which are substantially parallel and aligned on the coaptation surface plane in such a way that they can share the stress between them, according to their thickness; in other words chords form a multifilament functional unit which enrolls elements of increasing thickness in response to the mounting stress. The geometrical modifications of the valve apparatus architecture (annulus dilatation, leaflet retraction, chordal elongation or retraction) often associated with valve insufficiency due to chordal rupture, have the common result of causing, during systole, a radial disarrangement of the direction of most of the secondary chordae which are no longer parallel, aligned on the coaptation surface plane. Due to the negligible elastic module of the valve leaflet, in this new arrangement the various chordae cannot share the stress between themselves as they do in a normal physiological situation; on the contrary the thinner chordae nearer to the free margin are also loaded with the peak systolic stress, thus generating conditions favoring their rupture. It can, therefore, be hypothesized that the anatomopathological picture of valve insufficiency due to chordal rupture may be the final event of a series of geometrical modifications of valve apparatus architecture, the common consequence of which is to load thinner marginal chords with peak systolic stress from which they are normally spared, thus favoring their rupture.
- 1 April 2000
- Vol. 41 (2) , 193-202
Patterns of systolic stress distribution on mitral valve anterior leaflet chordal apparatus. A structural mechanical theoretical analysis.
Increasing diffusion and complexity of mitral valve repair procedures may prompt an interest in the evaluation of the patterns of stress distribution on the chords, which are, from the structural mechanical point of view, the weakest element of valve apparatus. This theoretical analysis concentrates in particular on the mitral valve anterior leaflet. As is known, the vast majority of the chordae are attached to the anterior leaflet within the coaptation area; during systole they are then necessarily parallel, aligned along the same plane as that of the leaflets' coaptation surface, to which they are attached; moreover the thickness of the chordae increases significantly from the marginal chordae to the more central ones. In normal conditions during systole the progressively wider coaptation surface causes the increasing stress to be supported by an increasing number of progressively thicker chords, which are substantially parallel and aligned on the coaptation surface plane in such a way that they can share the stress between them, according to their thickness; in other words chords form a multifilament functional unit which enrolls elements of increasing thickness in response to the mounting stress. The geometrical modifications of the valve apparatus architecture (annulus dilatation, leaflet retraction, chordal elongation or retraction) often associated with valve insufficiency due to chordal rupture, have the common result of causing, during systole, a radial disarrangement of the direction of most of the secondary chordae which are no longer parallel, aligned on the coaptation surface plane. Due to the negligible elastic module of the valve leaflet, in this new arrangement the various chordae cannot share the stress between themselves as they do in a normal physiological situation; on the contrary the thinner chordae nearer to the free margin are also loaded with the peak systolic stress, thus generating conditions favoring their rupture. It can, therefore, be hypothesized that the anatomopathological picture of valve insufficiency due to chordal rupture may be the final event of a series of geometrical modifications of valve apparatus architecture, the common consequence of which is to load thinner marginal chords with peak systolic stress from which they are normally spared, thus favoring their rupture.