Kamal S. Ayyat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kamal S. Ayyat has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Kenneth R. McCurry
Department of Thoracic and Cardiovascular Surgery, Cleveland Clinic Research, Cleveland, Ohio, USA
7 shared publications Toshihiro Okamoto
Department of Inflammation and Immunity, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
6 shared publicationsHiromichi Niikawa
Department of Inflammation and Immunity, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
5 shared publicationsYoshifumi Itoda
Department of Inflammation and Immunity, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
5 shared publicationsCarol F. Farver
Department of Anatomic Pathology, Cleveland Clinic, Cleveland, Ohio
3 shared publications- Hiromichi Niikawa
Department of Thoracic Surgery, Department of Public Health, Tohoku Medical and Pharmaceutical University, 983-8536, Japan, 1-15-1 Fukumuro, Miyagino-ku, Sendai City, Miyagi Prefecture
3 shared publications
Latest Publications
- Open Access
- 1 February 2025
- Published by AME Publishing Company in Current Challenges in Thoracic Surgery
- Vol. 7, 2
A narrative review on ex vivo lung perfusion: up-to-date role in lung transplantation
Background and Objective: Ex vivo lung perfusion (EVLP) is a method of perfusing and ventilating the lung outside of the donor body prior to lung transplantation (LTx). This was first described by Dr. Steen out of Lund, Sweden, and it has been adapted into multiple other protocols, including the Toronto protocol and the TransMedics Organ Care System (OCS) protocol, which is a portable EVLP system. As EVLP expands across institutions, there have been numerous additions to the abilities and utilizations of this ex vivo perfusion system. However, there is a varying degree of its use and the role it plays in transplantation, and a lack of consensus in its outcomes thus far. Thus, we summarize the roles of EVLP including assessment, preservation, and therapeutics of donor lungs, and provide our own clinical experience to further clarify its role. Methods: Studies listed on PubMed from March 2000, when EVLP was first described, until July 2024 were screened and considered for inclusion. Search language included: EVLP; ex vivo lung perfusion; ex vivo lung therapeutics; ex vivo lung assessment; ex vivo lung preservation. Publications that pertained to EVLP, reported novel data, or reviewed previously peer-reviewed manuscripts were included, and language inclusion was English. Key Content and Findings: The primary role of EVLP continues to be assessment of donor lungs, which allows for a more detailed interrogation of lungs that may have otherwise been rejected. However, EVLP also allows for extended preservation of lungs, as shown by both animal models and human studies. Now, experimental studies continue to find novel methods that EVLP may be used as a therapeutic tool as well. Our own institution has utilized EVLP in the development of unique scoring systems and lung preservation. We provide examples of EVLP prognosticating the successful transplantation of lungs that would otherwise not be transplanted, extending the preservation of donor lungs, and identifying donor lungs unsuitable for transplant that may have otherwise been used. Conclusions: EVLP has grown into a valuable assessment tool, while also providing opportunities for diagnostics, therapeutics, and organ preservation. Thus, EVLP has begun to expand the donor pool and continues to provide new opportunities within the transplant community.
- 1 February 2025
- Published by AME Publishing Company in Current Challenges in Thoracic Surgery
- Vol. 7, 2
Open AccessA narrative review on ex vivo lung perfusion: up-to-date role in lung transplantation
Background and Objective: Ex vivo lung perfusion (EVLP) is a method of perfusing and ventilating the lung outside of the donor body prior to lung transplantation (LTx). This was first described by Dr. Steen out of Lund, Sweden, and it has been adapted into multiple other protocols, including the Toronto protocol and the TransMedics Organ Care System (OCS) protocol, which is a portable EVLP system. As EVLP expands across institutions, there have been numerous additions to the abilities and utilizations of this ex vivo perfusion system. However, there is a varying degree of its use and the role it plays in transplantation, and a lack of consensus in its outcomes thus far. Thus, we summarize the roles of EVLP including assessment, preservation, and therapeutics of donor lungs, and provide our own clinical experience to further clarify its role. Methods: Studies listed on PubMed from March 2000, when EVLP was first described, until July 2024 were screened and considered for inclusion. Search language included: EVLP; ex vivo lung perfusion; ex vivo lung therapeutics; ex vivo lung assessment; ex vivo lung preservation. Publications that pertained to EVLP, reported novel data, or reviewed previously peer-reviewed manuscripts were included, and language inclusion was English. Key Content and Findings: The primary role of EVLP continues to be assessment of donor lungs, which allows for a more detailed interrogation of lungs that may have otherwise been rejected. However, EVLP also allows for extended preservation of lungs, as shown by both animal models and human studies. Now, experimental studies continue to find novel methods that EVLP may be used as a therapeutic tool as well. Our own institution has utilized EVLP in the development of unique scoring systems and lung preservation. We provide examples of EVLP prognosticating the successful transplantation of lungs that would otherwise not be transplanted, extending the preservation of donor lungs, and identifying donor lungs unsuitable for transplant that may have otherwise been used. Conclusions: EVLP has grown into a valuable assessment tool, while also providing opportunities for diagnostics, therapeutics, and organ preservation. Thus, EVLP has begun to expand the donor pool and continues to provide new opportunities within the transplant community.
- Open Access
- 1 April 2021
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 40 (4) , S69-S70
Real-Time Lung Weight Measurement during Ex Vivo Lung Perfusion: Clinical Importance of Early Weight Gain
- 1 April 2021
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 40 (4) , S69-S70
Open AccessReal-Time Lung Weight Measurement during Ex Vivo Lung Perfusion: Clinical Importance of Early Weight Gain
- 15 October 2020
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 59 (1) , 217-225
Ventricular assist device bridging with gender-mismatch increases rejection and decreases survival following a heart transplant
OBJECTIVES: Survival is poor following an orthotopic heart transplant with gender-mismatched donors and recipients. Patients bridged to an orthotopic heart transplant with a ventricular assist device (VAD) frequently become sensitized. We hypothesized that the combination of VAD bridging and gender-mismatch may result in greater rejection and poorer survival. METHODS: Data were obtained from the United Network of Organ Sharing database. Patients were divided into 4 groups: (i) VAD recipients who received a heart from a gender-matched donor (VAD-M); (ii) VAD recipients who received a heart from a gender-mismatched donor (VAD-MM); (iii) noVAD recipients who received a heart from a gender-matched donor (noVAD-M); and (iv) noVAD recipients who received a heart from a gender-mismatched donor (noVAD-MM). Rejection episodes within 1-year post-transplant and transplant survival were compared in VAD-M versus VAD-MM and noVAD-M versus noVAD-MM groups, respectively. RESULTS: Between January 2000 and June 2017, of 33 401 adult patients who underwent heart transplants, 8648, 2441, 12 761 and 4992 patients were identified as VAD-M, VAD-MM, noVAD-M and noVAD-MM, respectively. Rejection within 1-year post-transplant occurred in 23.3% and 27.3% of the VAD-M and VAD-MM groups, respectively (P < 0.01) and in 21.8% and 23.6% of the noVAD-M and noVAD-MM groups (P = 0.02), respectively. In an adjusted survival analysis, the VAD-MM group showed significantly worse survival than the VAD-M group (P < 0.01), whereas there was no significant difference between the noVAD-M and noVAD-MM groups (P = 0.21). CONCLUSIONS: Our results indicated that the combination of VAD bridging and gender-mismatch caused greater rejection and worse survival following a transplant. Further study is necessary to prove comparable post-transplant survival of gender-matched or -mismatched recipients without VAD bridging.
- 15 October 2020
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 59 (1) , 217-225
Ventricular assist device bridging with gender-mismatch increases rejection and decreases survival following a heart transplant
OBJECTIVES: Survival is poor following an orthotopic heart transplant with gender-mismatched donors and recipients. Patients bridged to an orthotopic heart transplant with a ventricular assist device (VAD) frequently become sensitized. We hypothesized that the combination of VAD bridging and gender-mismatch may result in greater rejection and poorer survival. METHODS: Data were obtained from the United Network of Organ Sharing database. Patients were divided into 4 groups: (i) VAD recipients who received a heart from a gender-matched donor (VAD-M); (ii) VAD recipients who received a heart from a gender-mismatched donor (VAD-MM); (iii) noVAD recipients who received a heart from a gender-matched donor (noVAD-M); and (iv) noVAD recipients who received a heart from a gender-mismatched donor (noVAD-MM). Rejection episodes within 1-year post-transplant and transplant survival were compared in VAD-M versus VAD-MM and noVAD-M versus noVAD-MM groups, respectively. RESULTS: Between January 2000 and June 2017, of 33 401 adult patients who underwent heart transplants, 8648, 2441, 12 761 and 4992 patients were identified as VAD-M, VAD-MM, noVAD-M and noVAD-MM, respectively. Rejection within 1-year post-transplant occurred in 23.3% and 27.3% of the VAD-M and VAD-MM groups, respectively (P < 0.01) and in 21.8% and 23.6% of the noVAD-M and noVAD-MM groups (P = 0.02), respectively. In an adjusted survival analysis, the VAD-MM group showed significantly worse survival than the VAD-M group (P < 0.01), whereas there was no significant difference between the noVAD-M and noVAD-MM groups (P = 0.21). CONCLUSIONS: Our results indicated that the combination of VAD bridging and gender-mismatch caused greater rejection and worse survival following a transplant. Further study is necessary to prove comparable post-transplant survival of gender-matched or -mismatched recipients without VAD bridging.
- 1 June 2020
- Published by Elsevier in Journal of Surgical Research
- Vol. 250, 88-96
Cellular Ex Vivo Lung Perfusion Beyond 1 Hour May Improve Marginal Donor Lung Assessment
- 1 June 2020
- Published by Elsevier in Journal of Surgical Research
- Vol. 250, 88-96
Cellular Ex Vivo Lung Perfusion Beyond 1 Hour May Improve Marginal Donor Lung Assessment
- 1 December 2019
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 108 (6) , 1913-1921
Combined Coronary Artery Bypass Surgery With Bone Marrow Stem Cell Transplantation: Are We There Yet?
- 1 December 2019
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 108 (6) , 1913-1921
Combined Coronary Artery Bypass Surgery With Bone Marrow Stem Cell Transplantation: Are We There Yet?
- 1 July 2019
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 38 (7) , 757-766
DireCt Lung Ultrasound Evaluation (CLUE): A novel technique for monitoring extravascular lung water in donor lungs
- 1 July 2019
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 38 (7) , 757-766
DireCt Lung Ultrasound Evaluation (CLUE): A novel technique for monitoring extravascular lung water in donor lungs
- 20 March 2019
- Published by Frontiers Media SA in Transplant International
- Vol. 32 (8) , 797-807
A novel concept for evaluation of pulmonary function utilizing PaO2/FiO2 difference at the distinctive FiO2 in cellularex vivolung perfusion—an experimental study
Background For more accurate lung evaluation in ex vivo lung perfusion (EVLP), we have devised a new parameter, PaO2/FiO2 ratio difference (PFD); PFD1‐0.4 = P/F ratio at FiO2 1.0 ‐ P/F ratio at FiO2 0.4. The aim of this study is to compare PFD and transplant suitability, and physiological parameters utilized in cellular EVLP. Methods Thirty‐nine human donor lungs were perfused. At 2 hours EVLP, PFD1‐0.4 was compared with transplant suitability and physiological parameters. In a second study, 10 pig lungs were perfused in same fashion. PFD1‐0.4 were calculated by blood from upper and lower lobe pulmonary veins (PV) and compared with lobe wet/dry ratio and pathological findings. Results In human model, receiver operating characteristic curve analysis showed PFD1‐0.4 had the highest area under curve, 0.90, sensitivity, 0.96, to detect non‐suitable lungs, and significant negative correlation with lung weight ratio (R2=0.26, p1‐0.4 on lower and upper lobe PV were significantly associated with corresponding lobe wet/dry ratios (R2=0.51, p=0.019; R2=0.37, p=0.060) respectively. Conclusion PFD1‐0.4 in EVLP demonstrated a significant correlation with lung weight ratio and allowed more precise assessment of individual lobes in detecting lung edema. Moreover, it might support decision‐making in evaluation with current EVLP criteria.
- 20 March 2019
- Published by Frontiers Media SA in Transplant International
- Vol. 32 (8) , 797-807
A novel concept for evaluation of pulmonary function utilizing PaO2/FiO2 difference at the distinctive FiO2 in cellularex vivolung perfusion—an experimental study
Background For more accurate lung evaluation in ex vivo lung perfusion (EVLP), we have devised a new parameter, PaO2/FiO2 ratio difference (PFD); PFD1‐0.4 = P/F ratio at FiO2 1.0 ‐ P/F ratio at FiO2 0.4. The aim of this study is to compare PFD and transplant suitability, and physiological parameters utilized in cellular EVLP. Methods Thirty‐nine human donor lungs were perfused. At 2 hours EVLP, PFD1‐0.4 was compared with transplant suitability and physiological parameters. In a second study, 10 pig lungs were perfused in same fashion. PFD1‐0.4 were calculated by blood from upper and lower lobe pulmonary veins (PV) and compared with lobe wet/dry ratio and pathological findings. Results In human model, receiver operating characteristic curve analysis showed PFD1‐0.4 had the highest area under curve, 0.90, sensitivity, 0.96, to detect non‐suitable lungs, and significant negative correlation with lung weight ratio (R2=0.26, p1‐0.4 on lower and upper lobe PV were significantly associated with corresponding lobe wet/dry ratios (R2=0.51, p=0.019; R2=0.37, p=0.060) respectively. Conclusion PFD1‐0.4 in EVLP demonstrated a significant correlation with lung weight ratio and allowed more precise assessment of individual lobes in detecting lung edema. Moreover, it might support decision‐making in evaluation with current EVLP criteria.
- 1 January 2019
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 157 (1) , 425-433
The protective effect of prone lung position on ischemia–reperfusion injury and lung function in an ex vivo porcine lung model
- 1 January 2019
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 157 (1) , 425-433
The protective effect of prone lung position on ischemia–reperfusion injury and lung function in an ex vivo porcine lung model
- 6 December 2018
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 28 (5) , 767-774
Significant parameters in the evaluation of donor lungs in single-lung cellular ex vivo lung perfusion
Typically, single-lung ex vivo lung perfusion (SL-EVLP) is preferred when there is concern of contamination from the opposite lung. However, a comprehensive assessment of the SL-EVLP has not been completed. The purpose of this study is to compare the physiological parameters of SL-EVLP and double-lung EVLP (DL-EVLP) in the assessment of transplant suitability. Seven pairs of rejected donor lungs were perfused in cellular EVLP, with a tidal volume of 6 ml/kg ideal body weight and a perfusion flow of 70 ml/kg/min. The transplant suitability of each side was judged in the DL-EVLP. Subsequently, the tidal volume and flow were reduced by half. The right SL-EVLP was maintained for 10 min by clamping the left main pulmonary artery and the bronchus. Similarly, left SL-EVLP was performed. The physiological parameters were compared between SL-EVLP and DL-EVLP. PO2/FiO2 ratio was significantly lower in SL-EVLP than in DL-EVLP [182.5 (127.5-309.5) vs 311.5 (257.5-377.0) mmHg, P < 0.001]. There was a significant correlation with a higher shunt fraction and PCO2 in the pulmonary vein in SL-EVLP when compared to DL-EVLP. There was no difference in peak inspiratory and plateau pressures between SL-EVLP and DL-EVLP. Suitable lungs (n = 6) were associated with better PO2/FiO2 ratios and lower airway pressures than non-suitable lungs (n = 8). In SL-EVLP, peak inspiratory and plateau pressures have clinical utility in the assessment of the transplant suitability. It is important that PO2/FiO2 ratio in SL-EVLP is appreciably lower than that in DL-EVLP. This discrepancy should be considered in the evaluation of the transplant suitability in SL-EVLP.
- 6 December 2018
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 28 (5) , 767-774
Significant parameters in the evaluation of donor lungs in single-lung cellular ex vivo lung perfusion
Typically, single-lung ex vivo lung perfusion (SL-EVLP) is preferred when there is concern of contamination from the opposite lung. However, a comprehensive assessment of the SL-EVLP has not been completed. The purpose of this study is to compare the physiological parameters of SL-EVLP and double-lung EVLP (DL-EVLP) in the assessment of transplant suitability. Seven pairs of rejected donor lungs were perfused in cellular EVLP, with a tidal volume of 6 ml/kg ideal body weight and a perfusion flow of 70 ml/kg/min. The transplant suitability of each side was judged in the DL-EVLP. Subsequently, the tidal volume and flow were reduced by half. The right SL-EVLP was maintained for 10 min by clamping the left main pulmonary artery and the bronchus. Similarly, left SL-EVLP was performed. The physiological parameters were compared between SL-EVLP and DL-EVLP. PO2/FiO2 ratio was significantly lower in SL-EVLP than in DL-EVLP [182.5 (127.5-309.5) vs 311.5 (257.5-377.0) mmHg, P < 0.001]. There was a significant correlation with a higher shunt fraction and PCO2 in the pulmonary vein in SL-EVLP when compared to DL-EVLP. There was no difference in peak inspiratory and plateau pressures between SL-EVLP and DL-EVLP. Suitable lungs (n = 6) were associated with better PO2/FiO2 ratios and lower airway pressures than non-suitable lungs (n = 8). In SL-EVLP, peak inspiratory and plateau pressures have clinical utility in the assessment of the transplant suitability. It is important that PO2/FiO2 ratio in SL-EVLP is appreciably lower than that in DL-EVLP. This discrepancy should be considered in the evaluation of the transplant suitability in SL-EVLP.