NSNikhil Vivek Shrivas

Nikhil Vivek Shrivas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nikhil Vivek Shrivas has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design optimization and structural analysis of a 3D printed robotic manipulator using polymer materials

    by Santosh Kumar Rai, Neha Ahlawat, Nikhil Vivek Shrivas, Domadala Pranav


  • Computation of physiological loading induced interstitial fluid motion in muscle standardized femur: Healthy vs. osteoporotic bone

    by Nikhil Vivek Shrivas, Subham Badhyal, Abhishek Kumar Tiwari, Ashutosh Mishra, Dharmendra Tripathi, Santosh Patil


  • Retracted
    Open Access

    Applications of Healthcare Robots in Combating the COVID-19 Pandemic

    by Shruti Raje, Nikunj Reddy, Houssem Jerbi, Princy Randhawa, Georgios Tsaramirsis, Nikhil Vivek Shrivas, Athanasia Pavlopoulou, Miloš Stojmenović, Dimitris Piromalis

    Due to the increasing number of COVID-19 cases, there is a remarkable demand for robots, especially in the clinical sector. SARS-CoV-2 mainly propagates due to close human interactions and contaminated surfaces, and hence, maintaining social distancing has become a mandatory preventive measure. This generates the need to treat patients with minimal doctor-patient interaction. Introducing robots in the healthcare sector protects the frontline healthcare workers from getting exposed to the coronavirus as well as decreases the need for medical personnel as robots can partially take over some medical roles. The aim of this paper is to highlight the emerging role of robotic applications in the healthcare sector and allied areas. To this end, a systematic review was conducted regarding the various robots that have been implemented worldwide during the COVID-19 pandemic to attenuate and contain the virus. The results obtained from this study reveal that the implementation of robotics into the healthcare field has a substantial effect in controlling the spread of SARS-CoV-2, as it blocks coronavirus propagation between patients and healthcare workers, along with other advantages such as disinfection or cleaning.


  • Physiological Loading-Induced Interstitial Fluid Dynamics in Osteon of Osteogenesis Imperfecta Bone

    by Nikhil Vivek Shrivas, Abhishek Kumar Tiwari, Rakesh Kumar, Santosh Patil, Dharmendra Tripathi, Subham Badhyal

    Osteogenesis imperfecta (OI), also known as “brittle bone disease,” is a genetic bone disorder. OI bones experience frequent fractures. Surgical procedures are usually followed by clinicians in the management of OI. It has been observed physical activity is equally beneficial in reducing OI bone fractures in both children and adults as mechanical stimulation improves bone mass and strength. Loading-induced mechanical strain and interstitial fluid flow stimulate bone remodeling activities. Several studies have characterized strain environment in OI bones, whereas very few studies attempted to characterize the interstitial fluid flow. OI significantly affects bone micro-architecture. Thus, this study anticipates that canalicular fluid flow reduces in OI bone in comparison to the healthy bone in response to physiological loading due to altered poromechanical properties. This work attempts to understand the canalicular fluid distribution in single osteon models of OI and healthy bone. A poromechanical model of osteon is developed to compute pore-pressure and interstitial fluid flow as a function of gait loading pattern reported for OI and healthy subjects. Fluid distribution patterns are compared at different time-points of the stance phase of the gait cycle. It is observed that fluid flow significantly reduces in OI bone. Additionally, flow is more static than dynamic in OI osteon in comparison to healthy subjects. This work attempts to identify the plausible explanation behind the diminished mechanotransduction capability of OI bone. This work may further be extended for designing better biomechanical therapies to enhance the fluid flow in order to improve osteogenic activities in OI bone.


  • Design and development of a structurally stable quadruped robot for surveillance

    by Nakul Yadav, Tejasvi Raina, Naman Gupta, Nikhil Vivek Shrivas

    Quadrupeds have the ability to access diverse environment where other living creatures and humans can’t go in a very effective way. Their such attributes are taken into consideration and used into this project to develop a quadruped robot with the abilities to have various kind of motions like to transverse different terrains in all directions along with ascending and descending motions over obstacles. The major weight contributing factor of a mobile robot is the actuation system, thus appropriate numbers of actuators should be used, hence challenging to minimize the weight of the bot. Mechanism here emulates the locomotive motion of the usual quadrupeds with reduced number of actuators which in turn reduces both weight and cost. The number of actuators is reduced by performing a Von Mises Static structural analysis so that the mechanism performs the desired motion without any constraint. The material used for designing the quadruped robot is Nylon 6,6 and using finite element analysis the effect of loading on material strength has been investigated. The quadruped is loaded with varying load to calculate the variations produced in the stresses, strain and deflection in the robot for various walking configurations of quadruped and the results are plotted accordingly. Different types of gait motions are also studied to get a stable walking motion for the quadruped.


  • Canalicular fluid flow induced by loading waveforms: A comparative analysis

    by Rakesh Kumar, Abhishek Kumar Tiwari, Dharmendra Tripathi, Nikhil Vivek Shrivas, Fahad Nizam


  • Investigation on Loading-Induced Fluid Flow in Osteogenesis Imperfecta Bone

    by Nikhil V. Shrivas, Abhishek Kumar Tiwari, Rakesh Kumar, Dharmendra Tripathi, Vasu Raman Sharma

    Osteogenesis Imperfecta (OI) is a genetic bone disorder which is typically characterized by brittle bones with frequent fractures. It is also known as brittle bone disease. Surgical procedure is one of the ways adopted by clinicians for the management of OI. In recent years, it has however become clear that physical activity is equally important for managing OI in both children and adults. Exogenous mechanical stimulation e.g. prophylactic exercises may be useful in improving the bone mass and strength of OI bones as loading-induced mechanical components e.g. normal strain and canalicular fluid flow stimulate remodeling activities. Several studies have characterized the strain environment in OI bones, whereas, very few studies attempted to characterize the canalicular fluid flow. In the present study, we anticipate that canalicular fluid flow reduces in OI bone as compared to healthy bone under physiological loading. This work accordingly computes the canalicular fluid distribution in the single osteon model of OI and control/normal bones subjected to normal physiological loadings. A transversely isotropic poroelastic model of osteon is developed. Loading is applied in accordance with gait cycles reported for OI and healthy bones. Fluid distribution patterns computed for OI and healthy bones are compared at different time-points of stance phase of the gait cycle. A significant reduction in fluid flow is observed in case of OI bone as compared to healthy bone. This clearly indicates that improvements in physical activities or exercises can be designed to enhance the level of canalicular fluid flow to initiate possible osteogenic activities and the bone.


  • Development of sensor based front end collision avoidance system for highways

    by Tanuja Sheorey, Nikhil Vivek Shrivas

    Potential of hazards due to collision between the automobiles are severe and often life threatening. The reason found for collision in most of the cases was inattention of the driver due to long and exhausting drive. The chances of front end collision thus become unavoidable in highways. Front end collision avoidance system (FECAS) work independently and is designed to reduce the speed of a vehicle automatically on probability of potential crash. The work done on FECAS for minimizing the chances of collision is presented here. The work focuses on the collision avoidance between the two vehicles moving one after another by detecting the position of the preceding vehicle and controlling the speed of the host vehicle that carries the FECAS. A fusion of sensors was used to get the information about the position and speed of the preceding vehicle. Speed of the host vehicle was gradually or immediately reduced accordingly. Virtual system modeling was carried out and tested with hardware in loop simulation for sensors and actuation performance. Finally, the FECAS was incorporated on scaled model of a car and tested in the real environment. Successful controlling of the car was achieved under all conditions. The car came to complete halt at a distance varying between 0.65 m to 2.5 m and no incidence of collision occurred when the car was in the critical zone.