LMLia Toledo Moreira Mota

Lia Toledo Moreira Mota

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lia Toledo Moreira Mota has a total of 79 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Characterization of Vegetable Resin-Based Coatings for Application as Cool Roof Paint

    by Fátima Yubero, Fernando Luís Fertonani, Janine Padilha Botton, Noelia Alchapar, Ezekiel Martin, Cláudia Cotrim Pezzuto, Lia Toledo Moreira Mota

  • Open Access

    Analysis of the Suitability of Implementing a Photovoltaic Energy Generation System for a University Campus

    by Sidney Riva, Marcius Fabius Henriques de Carvalho, Lia Toledo Moreira Mota, Claudia Cotrim Pezzuto

    Objective: The objective of this study is to investigate the feasibility of implementing a photovoltaic power generation system at Campus II of the Pontifical Catholic University of Campinas. This campus serves the teaching and research area and the hospital area occupied by the Celso Pierro Hospital and Maternity Ward (HMCP). Theoretical Framework: Given the growth in electricity consumption, it is necessary to develop and apply alternative energy sources with a sustainable objective. Method: Energy is supplied by Companhia Paulista de Força e Luz (CPFL) from a single power source to the main cabin. The main cabin feeds the secondary distribution cabins, some of which are interconnected with diesel generators. This study evaluates the implementation of a photovoltaic solar energy supply system as a complement to the CPFL supply and begins by understanding the behavior of current energy consumption. In this sense, the internal consumption of the different activity sectors was monitored to identify the criticality of those with the highest consumption. Results and Discussion: This research presents, in the analysis stage, the behavior of the energy supplied to Campus II of PUC Campinas. Internal distribution is evaluated based on monitoring the demand and consumption of all main substations. The internal energy distribution substations are positioned to provide energy distribution to two main areas, which are the Hospital area and the University area. As the University area is the object of study in this work and evaluating the consumption and demand of cabins 4, 5, and 8, it was pointed out that the UF (utilization factor) of the University cabins are: cabin 4 operates at 68.00%, cabin 5 operates at 88.30%, and cabin 8 operates at 13.10%. Internal optimizations were proposed with the aim of improving the distribution and utilization factor of the cabins in the University area. Given the need for expansion, studies indicate that dividing the power supply could make more power available to the hospital and improve optimization and distribution for the university area, with the option of supplementing the power supply through photovoltaic solar panels to generate electricity from solar energy. Research Implications: Based on this data, improvements were proposed to more efficiently serve critical sectors, in accordance with the ABNT NBR ISO 50001:2018 standard. The improvement proposals considered were: changing the usage policy, replacing inefficient equipment, and integrating with a system for alternative energy generation. Originality/Value: This work is expected to develop suggestions that will contribute to reducing costs and increasing the level of service for users.

  • Open Access

    Estimativa do equivalente de CO2 atmosférico por modificação do albedo em cidades latino-americanas

    by Noelia Liliana Alchapar, Cláudia Cotrim Pezzzuto, Dario Ricardo Jaime, Fátima Yubero, Lia Toledo Moreira Mota, Ezekiel Martin, Hashem Akbari

    O objetivo da pesquisa é quantificar o potencial de CO2 atmosférico equivalente associado à modificação doalbedo das superfícies urbanas (telhados e pisos) de cidades latino-americanas, com base na metodologiaproposta por Akbari em 2023. O estudo terá como foco a análise de cinco cidades latino-americanas que fazemparte do projeto de cooperação internacional sobre transição energética -Mendoza e Posadas, na Argentina;Campinas, no Brasil; e Assunção, no Paraguai. Espera-se que gere um quadro de referência para avaliar osbenefícios ambientais das tecnologias de nanorrevestimento para telhados frios e compensar as emissões dedióxido de carbono geradas nas cidades. Para isso, foi desenvolvido um algoritmo em Python que sistematiza asequações da metodologia de Akbari. Os resultados mostram que, ao aumentar em 1% o albedo das superfíciesdas cidades estudadas, a compensação de CO2 varia entre 2.7 e 3.6 kg por m2, sendo maior em regiões commaior insolação e menor percentual de nebulosidade.


  • Open Access

    Metodologia para Avaliação da Caminhabilidade em Centros Urbanos

    by Marcius Fabius Henriques de Carvalho, Guilherme Kato Rodrigues, Lia Toledo Moreira Mota, Cláudia Cotrim Pezzuto

    Rapid urbanization has turned urban mobility into one of the biggest challenges for modern cities. Intense competition for public spaces in downtown areas of medium and large cities leads to accidents, congestion, increased costs and travel time, and environmental pollution caused by individual motorized and public transport. Searching for a contribution to social, economic, and environmental sustainability this work, considering walking as an essential form of mobility in an urban center of developing countries, proposes a methodology for supporting citizens who arrive at the downtown public bus terminal to select the best walking route to reach essential public services places in the city. Three macro indicators are considered in determining the best walking route: The ambiance indicator results from six sub-indicators, representing physical characteristics of the walking space; the Comfort indicator results from two sub-indicators, representing the visual attractiveness and local comfort; and the Safety indicator results from four sub-indicators; representing public and personal sensations of safety. The proposed methodology is based on two steps: the first reduces the twelve sub-indicators of each route segment to three main indicators. In the second step, a multi-objective optimization problem is formulated to determine the best route from the origin point (public urban terminals) to the citizen interest point. The identification of the most suitable downtown walkability areas can assist local authorities in developing improvement strategies for their ambiance, safety, and comfort standards, actions that will contribute to environmental sustainability and providing urban areas with walking spaces that meet the citizen's expectations.

  • Open Access

    Use of long-range wireless technology for air temperature monitoring in urban areas

    by Paulo Pisconti Kato, Lia Toledo Moreira Mota, Cláudia Cotrim Pezzuto, Marcius Fabius Henriques de Carvalho, Jean Victor Barrozo Chaves

    Monitoring air temperature is absolutely crucial in smart cities for several reasons. It directly impacts the comfort and health of urban residents, significantly influencing their daily activities and well-being. Continuous monitoring of air temperature allows city authorities to identify areas prone to heat stress and implement targeted interventions, such as urban green spaces or cooling infrastructure, to effectively mitigate the effects of extreme heat events. Additionally, accurate temperature data plays a vital role in optimizing energy usage for heating and cooling systems, leading to more efficient resource allocation and a reduced environmental impact. Furthermore, understanding temperature variations across different city zones helps urban planners make informed decisions regarding urban design and infrastructure development to create more resilient and sustainable cities in the face of climate change. Integrating temperature monitoring into the framework of smart cities enhances livability, promotes environmental sustainability, and fosters resilience in the face of changing climatic conditions. This work proposes the usage of long-range data transmission technology for air temperature monitoring in urban areas.

  • Open Access

    Urban occupation and surface runoff in cities: a study case in Piracicaba - SP

    by Leonardo da Silva Granziera, Marcius Fabius Henriques de Carvalho, Lia Toledo Moreira Mota, Cláudia Cotrim Pezzuto

    This study analyzes how uncontrolled human occupation can negatively impact surface runoff conditions in urban environments. For this purpose, the study assesses the correlation between rainfall, Piracicaba River flow and the urban occupation growth regarding the incidence of floods in Piracicaba-SP. To address the research question: Is the increase in flooding caused by the increased population density? The following data was used: flow and precipitation data in the urban perimeter, obtained from the Piracicaba Water and Electricity Department; population and density data from five neighborhoods based on the "Google Earth Pro" software, covering sixteen years of study. The findings indicate that three districts experienced increased flooding, while two other well-established districts did not encounter significant changes in flood frequency.

  • Open Access

    Uso de sensor eletrônico para a avaliação de teor de dióxido de carbono no Parque Industrial de Paulínia

    by Jô Vinícius Barrozo Chaves, Lia Toledo Moreira Mota, Regina Márcia Longo, Admilson Írio Ribeiro, Cláudia Cotrim Pezzuto, Marcius Fabius Henriques De Carvalho

    Os impactos associados ao ambiente urbano, como danos físicos pela falta de vegetação e aumento da emissão de dióxido de carbono (CO2) em decorrência da atividade econômica, têm trazido a necessidade da mitigação de danos. Dessa forma, como propostas como a de preservação de áreas verde e inserção de vegetação em ambientes impermeabilizados têm sido uma das principais respostas. No entanto, para garantir a tomada de decisão e criação um ambiente sustentável ressalta-se a necessidade de informações. Para isso, têm sido desenvolvidas novas tecnologias voltadas ao monitoramento ambiental a partir de novos instrumentos e metodologias de aquisição de dados. Frente a esse contexto, o presente estudo tem como objetivo o desenvolvimento de um medidor de concentração de CO2, e a partir desse equipamento, avaliar a diferença da concentração de CO2 atmosférico numa área industrial em relação a um fragmento florestal. Os resultados indicaram em ambos os períodos monitorados, que o fragmento vegetação apresentou menor concentração de CO2 em relação a área industrial, enquanto a parcela rural apresentou menores concentrações de CO2. Foi, também, identificado erro na coleta final do sensor, causando perda de dados, destacando a necessidade de aprofundamento no tema e no aparato construído.

  • Open Access

    Comportamento térmico de fachadas urbanas com diferentes revestimentos cerâmicos

    by Ana Júlia Pilon Castello, Marcius Fabius Henriques de Carvalho, Lia Toledo Moreira Mota, Claudia Cotrim Pezzuto

    A radiação solar incidente em revestimentos das fachadas urbanas pode gerar acúmulo de calor nas cidades. Em consequência, as envoltórias das construções podem causar desconforto térmico aos habitantes e potencializar a demanda energética para resfriamento dos ambientes. Neste sentido, o objetivo deste trabalho é avaliar o desempenho térmico de fachadas com revestimentos cerâmicos de diferentes refletâncias solares investigando a influência das orientações norte, sul, leste e oeste. A partir de amostras expostas ao sol em painéis verticais, em ambiente externo, em dia de verão, foram realizadas medições de temperatura superficial, refletância solar e temperatura do ar. Os resultados mostram que a fachada leste apresentou a maior temperatura superficial média durante o período diurno, 33,0°C, em comparação com 28,3°C, 27,8°C e 27,7°C nas fachadas norte, sul e oeste, respectivamente. Entretanto, apresentou um rápido resfriamento no período noturno com temperatura superficial média de 26,4°C, em comparação com 28,5, 26,7 e 34,7 nas fachadas norte, sul, e oeste, respectivamente. Destaca-se que a fachada oeste apresentou a maior temperatura superficial média máxima, 63,9°C, com diferença de 24,9°C da fachada sul. Por outro lado, revestimentos de diferentes cores e refletâncias apresentam comportamento térmico distinto nas diferentes fachadas. Notou-se que o aumento da refletância de 3,7% (AZE_LB) para 50,5% (BR_LB) pode gerar uma diferença na temperatura superficial máxima de 18,9°C (oeste), 15,1°C (leste), 7,6°C (norte) e 3°C (sul). Assim ressalta-se a considerável influência da característica e da orientação da superfície no desempenho térmico das fachadas urbanas, para correta utilização dos revestimentos e para mitigação do aquecimento urbano.


  • Open Access

    Optimal Power Flow Technique for Distribution System Considering Distributed Energy Resources (DER)

    by Adolfo Blengini Neto, Maria Beatriz Barbosa, Lia Moreira Mota, Marina Lavorato, Marcius F. H. de Carvalho

    Modern electric power systems consist of large-scale, highly complex interconnected systems projected to match the intense demand growth for electrical energy. This involves the decision of generation, transmission, and distribution of resources at different time horizons. They also face challenges in incorporating new forms of generation, distributed generations, which are located close to consumer centers, and new loads such as electric vehicles. Traditionally, the nonlinear Newton–Raphson optimization method is used to support operational decisions in such systems, known as Optimal Power Flow (OPF). Although OPF is one of the most practically important and well-researched sub-fields of constrained nonlinear optimization and has a rich history of research, it faces the convergence difficulties associated with all problems represented using non-linear power flow constraints. The proposal is to present an approach in a software component in cloud Application Programming Interface (API) format, with alternative modeling of the electrical optimization problem as a non-linear objective function and representing electric network constraints modeled through both current and voltage Kirchhoff linear equations. This representation overcomes the non-linearity of the OPF problem considering Distributed Energy Resources (DER). The robustness, scalability, and availability of the method are tested on the IEEE-34 bus system with several modifications to accommodate the DER testing under conditions and in radial or meshed distribution systems under different load scenarios.


  • Sensors networkfor the evaluations of the meteorological variables in urban green areas: developmentand applications.

    by Jô Vinícius Barrozo Chaves, Lia Toledo Moreira Mota, Regina Márcia Longo, Admilson Írio Ribeiro, Daniel Braga Barros, José Ricardo Alves