Kamatam Venkata Subbaiah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kamatam Venkata Subbaiah has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
A. Natarajan
Indira Gandhi Centre for Atomic Research, Safety Research and Health Physics Program Kalpakkam-603102, Tamilnadu, India
7 shared publicationsD. V. Gopinath
Indira Gandhi Centre for Atomic Research, Safety Research and Health Physics Program Kalpakkam-603102, Tamilnadu, India
6 shared publicationsC. Sunil Sunny
5 shared publicationsL. Thilagam
AERB-Safety Research Institute, Kalpakkam 603 102, India
3 shared publicationsP. Mohanakrishnan
Indira Gandhi Centre for Atomic Research; Kalpakkam-603102 Tamilnadu India
3 shared publicationsR. Sarangapani
Radiological Safety Division, IGCAR, Kalpakkam 603 102, India
3 shared publications
Latest Publications
- 1 July 2013
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 57, 246-255
An inverse calculation technique for optimization of gamma ray shielding designs
- 1 July 2013
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 57, 246-255
An inverse calculation technique for optimization of gamma ray shielding designs
- 1 June 2011
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 241 (6) , 2257-2270
Passive system reliability analysis using Response Conditioning Method with an application to failure frequency estimation of Decay Heat Removal of PFBR
- 1 June 2011
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 241 (6) , 2257-2270
Passive system reliability analysis using Response Conditioning Method with an application to failure frequency estimation of Decay Heat Removal of PFBR
- 1 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 597-603
Variance quantification of functional reliability estimates using re-sampling techniques
Passive systems, which completely depend on natural phenomena such as gravity, conduction and convection to accomplish the safety functions, are increasingly being used in new generation nuclear reactor designs. However, since the driving forces of passive systems are weak, they are more vulnerable to associated uncertainties and there may be a non-zero probability for the system to deviate from the intended behavior and leads to functional failure. Methods for quantification of the functional failure include Monte-Carlo simulation of the system uncertainties using a validated mechanistic code. Generally, the mechanistic codes used for complex system modeling are computationally expensive and Monte-Carlo simulation for estimating small failure probabilities requires more time and often become prohibitive. In this respect, recently, functional reliability methodologies including advanced simulation techniques such as subset simulation, Markov chain Monte-Carlo, importance sampling, and response conditioning method are reported in open literature. Unlike in the case of direct Monte Carlo simulation, for the probability estimates obtained using these advanced simulations, analytical formulas are not available to estimate standard error and confidence interval. In this paper, the estimation of standard error and confidence interval of functional reliability estimates using computationally efficient re-sampling methods based on bootstrap technique are described. Numerical application of these methods, to quantify the variability of functional reliability estimates, is also explained.
- 1 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 597-603
Variance quantification of functional reliability estimates using re-sampling techniques
Passive systems, which completely depend on natural phenomena such as gravity, conduction and convection to accomplish the safety functions, are increasingly being used in new generation nuclear reactor designs. However, since the driving forces of passive systems are weak, they are more vulnerable to associated uncertainties and there may be a non-zero probability for the system to deviate from the intended behavior and leads to functional failure. Methods for quantification of the functional failure include Monte-Carlo simulation of the system uncertainties using a validated mechanistic code. Generally, the mechanistic codes used for complex system modeling are computationally expensive and Monte-Carlo simulation for estimating small failure probabilities requires more time and often become prohibitive. In this respect, recently, functional reliability methodologies including advanced simulation techniques such as subset simulation, Markov chain Monte-Carlo, importance sampling, and response conditioning method are reported in open literature. Unlike in the case of direct Monte Carlo simulation, for the probability estimates obtained using these advanced simulations, analytical formulas are not available to estimate standard error and confidence interval. In this paper, the estimation of standard error and confidence interval of functional reliability estimates using computationally efficient re-sampling methods based on bootstrap technique are described. Numerical application of these methods, to quantify the variability of functional reliability estimates, is also explained.
- 30 November 2010
- Published by Elsevier in Medical Dosimetry
- Vol. 35 (3) , 230-237
Evaluation of Scatter Contribution and Distance Error by Iterative Methods for Strength Determination of HDR 192Ir Brachytherapy Source
- 30 November 2010
- Published by Elsevier in Medical Dosimetry
- Vol. 35 (3) , 230-237
Evaluation of Scatter Contribution and Distance Error by Iterative Methods for Strength Determination of HDR 192Ir Brachytherapy Source
- Open Access
- 20 March 2010
- Published by Springer Nature in Pramana
- Vol. 74 (3) , 457-468
Dosimetric measurements and Monte Carlo simulation for achieving uniform surface dose in pulsed electron beam irradiation facility
- 20 March 2010
- Published by Springer Nature in Pramana
- Vol. 74 (3) , 457-468
Open AccessDosimetric measurements and Monte Carlo simulation for achieving uniform surface dose in pulsed electron beam irradiation facility
- 28 February 2010
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 37 (2) , 144-165
Inter-comparison of JEF-2.2 and JEFF-3.1 evaluated nuclear data through Monte Carlo analysis of VVER-1000 MOX Core Computational Benchmark
- 28 February 2010
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 37 (2) , 144-165
Inter-comparison of JEF-2.2 and JEFF-3.1 evaluated nuclear data through Monte Carlo analysis of VVER-1000 MOX Core Computational Benchmark
- Open Access
- 1 January 2010
- Published by Medknow in Journal of Medical Physics
- Vol. 35 (2) , 88-99
Suitability of point kernel dose calculation techniques in brachytherapy treatment planning
Brachytherapy treatment planning system (TPS) is necessary to estimate the dose to target volume and organ at risk (OAR). TPS is always recommended to account for the effect of tissue, applicator and shielding material heterogeneities exist in applicators. However, most brachytherapy TPS software packages estimate the absorbed dose at a point, taking care of only the contributions of individual sources and the source distribution, neglecting the dose perturbations arising from the applicator design and construction. There are some degrees of uncertainties in dose rate estimations under realistic clinical conditions. In this regard, an attempt is made to explore the suitability of point kernels for brachytherapy dose rate calculations and develop new interactive brachytherapy package, named as BrachyTPS, to suit the clinical conditions. BrachyTPS is an interactive point kernel code package developed to perform independent dose rate calculations by taking into account the effect of these heterogeneities, using two regions build up factors, proposed by Kalos. The primary aim of this study is to validate the developed point kernel code package integrated with treatment planning computational systems against the Monte Carlo (MC) results. In the present work, three brachytherapy applicators commonly used in the treatment of uterine cervical carcinoma, namely (i) Board of Radiation Isotope and Technology (BRIT) low dose rate (LDR) applicator and (ii) Fletcher Green type LDR applicator (iii) Fletcher Williamson high dose rate (HDR) applicator, are studied to test the accuracy of the software. Dose rates computed using the developed code are compared with the relevant results of the MC simulations. Further, attempts are also made to study the dose rate distribution around the commercially available shielded vaginal applicator set (Nucletron). The percentage deviations of BrachyTPS computed dose rate values from the MC results are observed to be within plus/minus 5.5% for BRIT LDR applicator, found to vary from 2.6 to 5.1% for Fletcher green type LDR applicator and are up to -4.7% for Fletcher-Williamson HDR applicator. The isodose distribution plots also show good agreements with the results of previous literatures. The isodose distributions around the shielded vaginal cylinder computed using BrachyTPS code show better agreement (less than two per cent deviation) with MC results in the unshielded region compared to shielded region, where the deviations are observed up to five per cent. The present study implies that the accurate and fast validation of complicated treatment planning calculations is possible with the point kernel code package.
- 1 January 2010
- Published by Medknow in Journal of Medical Physics
- Vol. 35 (2) , 88-99
Open AccessSuitability of point kernel dose calculation techniques in brachytherapy treatment planning
Brachytherapy treatment planning system (TPS) is necessary to estimate the dose to target volume and organ at risk (OAR). TPS is always recommended to account for the effect of tissue, applicator and shielding material heterogeneities exist in applicators. However, most brachytherapy TPS software packages estimate the absorbed dose at a point, taking care of only the contributions of individual sources and the source distribution, neglecting the dose perturbations arising from the applicator design and construction. There are some degrees of uncertainties in dose rate estimations under realistic clinical conditions. In this regard, an attempt is made to explore the suitability of point kernels for brachytherapy dose rate calculations and develop new interactive brachytherapy package, named as BrachyTPS, to suit the clinical conditions. BrachyTPS is an interactive point kernel code package developed to perform independent dose rate calculations by taking into account the effect of these heterogeneities, using two regions build up factors, proposed by Kalos. The primary aim of this study is to validate the developed point kernel code package integrated with treatment planning computational systems against the Monte Carlo (MC) results. In the present work, three brachytherapy applicators commonly used in the treatment of uterine cervical carcinoma, namely (i) Board of Radiation Isotope and Technology (BRIT) low dose rate (LDR) applicator and (ii) Fletcher Green type LDR applicator (iii) Fletcher Williamson high dose rate (HDR) applicator, are studied to test the accuracy of the software. Dose rates computed using the developed code are compared with the relevant results of the MC simulations. Further, attempts are also made to study the dose rate distribution around the commercially available shielded vaginal applicator set (Nucletron). The percentage deviations of BrachyTPS computed dose rate values from the MC results are observed to be within plus/minus 5.5% for BRIT LDR applicator, found to vary from 2.6 to 5.1% for Fletcher green type LDR applicator and are up to -4.7% for Fletcher-Williamson HDR applicator. The isodose distribution plots also show good agreements with the results of previous literatures. The isodose distributions around the shielded vaginal cylinder computed using BrachyTPS code show better agreement (less than two per cent deviation) with MC results in the unshielded region compared to shielded region, where the deviations are observed up to five per cent. The present study implies that the accurate and fast validation of complicated treatment planning calculations is possible with the point kernel code package.
- 1 October 2009
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 36 (10) , 1502-1515
VVER-1000 MOX Core Computational Benchmark analysis using indigenous codes EXCEL, TRIHEX-FA and HEXPIN
- 1 October 2009
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 36 (10) , 1502-1515
VVER-1000 MOX Core Computational Benchmark analysis using indigenous codes EXCEL, TRIHEX-FA and HEXPIN
- 1 May 2009
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 36 (4) , 505-519
A VVER-1000 LEU and MOX assembly computational benchmark analysis using the lattice burnup code EXCEL
- 1 May 2009
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 36 (4) , 505-519
A VVER-1000 LEU and MOX assembly computational benchmark analysis using the lattice burnup code EXCEL
- 1 May 2009
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 36 (4) , 481-492
Integration of functional reliability analysis with hardware reliability: An application to safety grade decay heat removal system of Indian 500MWe PFBR
- 1 May 2009
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 36 (4) , 481-492
Integration of functional reliability analysis with hardware reliability: An application to safety grade decay heat removal system of Indian 500MWe PFBR