Azwatee Abdul Aziz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Azwatee Abdul Aziz has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Noor Azlin Yahya
Department of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia
2 shared publications Noor Hayaty Abu Kasim
2 shared publicationsNorasmatul Akma Ahmad
2 shared publications- Nozimjon Tuygunov
Department of Restorative Dentistry, Kimyo International University in Tashkent, Tashkent, Uzbekistan
2 shared publications Rana Ahmed Abuzaid
2 shared publicationsSaedah Siraj
2 shared publications
Latest Publications
- Open Access
- 29 October 2026
- Published by Springer Nature in BMC Oral Health
Quantitative in vivo monitoring of early erosion-associated enamel optical changes using swept-source optical coherence tomography (SS-OCT)
- 29 October 2026
- Published by Springer Nature in BMC Oral Health
Open AccessQuantitative in vivo monitoring of early erosion-associated enamel optical changes using swept-source optical coherence tomography (SS-OCT)
- Open Access
- 29 June 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Effects of energy drinks on flexural and optical properties of conventional and bulk-fill resin composites: an in vitro swept-source optical coherence tomography (SS-OCT) study
Energy drinks are widely consumed acidic beverages that may compromise the longevity of resin composite restorations. Furthermore, limited information is available regarding the application of swept-source optical coherence tomography (SS-OCT) for detecting early beverage-induced alterations in resin composites.This study aimed to evaluate the effects of commercially available energy drinks on the flexural and optical properties of conventional and bulk-fill resin composites. A total of 150 specimens were prepared from a conventional nano-hybrid resin composite (Aura Easy, AE) and a bulk-fill nano-hybrid resin composite (Aura Bulk Fill, BF). One hundred rectangular specimens (12 × 2 × 2 mm; n = 10/group) were fabricated for flexural testing, while 50 disc-shaped specimens (10 × 2 mm; n = 5/group) were prepared for optical assessment. Specimens were immersed in Red Bull, Monster, Gatorade, or Extra Joss for 7 days at 37 °C. Control specimens were stored in air for flexural testing and distilled water for optical assessment. Flexural strength and flexural modulus were evaluated using a three-point bending test. Surface and subsurface alterations were qualitatively assessed using SS-OCT. Data were analysed using one-way ANOVA and independent-samples t-tests (α = 0.05). No statistically significant differences in flexural strength or flexural modulus were observed between control and energy drink groups for either composite material (p > 0.05). Flexural strength values ranged from 69.16 to 87.82 MPa, while flexural modulus values ranged from 3.35 to 4.45 GPa. Despite the absence of significant mechanical deterioration, SS-OCT revealed localized increases in backscattered intensity and surface discontinuities in AE specimens immersed in Red Bull, Monster, and Extra Joss, and in BF specimens immersed in Monster and Extra Joss, suggesting early surface degradation and optical alterations. Short-term exposure to energy drinks did not significantly affect the flexural properties of the tested resin composites. However, qualitative SS-OCT assessment revealed localized optical alterations suggestive of possible surface and subsurface changes that were not reflected by conventional mechanical testing. These findings highlight the potential of SS-OCT as a non-destructive tool for evaluating early material alterations following acidic beverage exposure.
- 29 June 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Open AccessEffects of energy drinks on flexural and optical properties of conventional and bulk-fill resin composites: an in vitro swept-source optical coherence tomography (SS-OCT) study
Energy drinks are widely consumed acidic beverages that may compromise the longevity of resin composite restorations. Furthermore, limited information is available regarding the application of swept-source optical coherence tomography (SS-OCT) for detecting early beverage-induced alterations in resin composites.This study aimed to evaluate the effects of commercially available energy drinks on the flexural and optical properties of conventional and bulk-fill resin composites. A total of 150 specimens were prepared from a conventional nano-hybrid resin composite (Aura Easy, AE) and a bulk-fill nano-hybrid resin composite (Aura Bulk Fill, BF). One hundred rectangular specimens (12 × 2 × 2 mm; n = 10/group) were fabricated for flexural testing, while 50 disc-shaped specimens (10 × 2 mm; n = 5/group) were prepared for optical assessment. Specimens were immersed in Red Bull, Monster, Gatorade, or Extra Joss for 7 days at 37 °C. Control specimens were stored in air for flexural testing and distilled water for optical assessment. Flexural strength and flexural modulus were evaluated using a three-point bending test. Surface and subsurface alterations were qualitatively assessed using SS-OCT. Data were analysed using one-way ANOVA and independent-samples t-tests (α = 0.05). No statistically significant differences in flexural strength or flexural modulus were observed between control and energy drink groups for either composite material (p > 0.05). Flexural strength values ranged from 69.16 to 87.82 MPa, while flexural modulus values ranged from 3.35 to 4.45 GPa. Despite the absence of significant mechanical deterioration, SS-OCT revealed localized increases in backscattered intensity and surface discontinuities in AE specimens immersed in Red Bull, Monster, and Extra Joss, and in BF specimens immersed in Monster and Extra Joss, suggesting early surface degradation and optical alterations. Short-term exposure to energy drinks did not significantly affect the flexural properties of the tested resin composites. However, qualitative SS-OCT assessment revealed localized optical alterations suggestive of possible surface and subsurface changes that were not reflected by conventional mechanical testing. These findings highlight the potential of SS-OCT as a non-destructive tool for evaluating early material alterations following acidic beverage exposure.
- 30 October 2025
- Published by Springer Nature
- p. 1-34
Sustainability in Dental Education
- 24 October 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 163, 106196
Nano-structural reinforcement of glass ionomer cement: unleashing the potential of hydroxyapatite and tetracalcium phosphate
- 24 October 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 163, 106196
Nano-structural reinforcement of glass ionomer cement: unleashing the potential of hydroxyapatite and tetracalcium phosphate
- 18 October 2025
- Published by Springer Nature
- p. 1-35
Treatment Strategies in Dentistry: Core Concepts and Future Issues
- 18 October 2025
- Published by Springer Nature
- p. 1-35
Treatment Strategies in Dentistry: Core Concepts and Future Issues
- 2 May 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 169, 107044
The impact of resin coatings on the properties and performance of glass ionomer cements: A systematic review
- 2 May 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 169, 107044
The impact of resin coatings on the properties and performance of glass ionomer cements: A systematic review
- 8 February 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 133 (4) , 1057.e1-1057.e7
Effects of different fabrication techniques on the marginal gap of interim crowns as assessed by optical coherence tomography: An in vitro study
- 8 February 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 133 (4) , 1057.e1-1057.e7
Effects of different fabrication techniques on the marginal gap of interim crowns as assessed by optical coherence tomography: An in vitro study
- 1 March 2024
- Published by Operative Dentistry in Operative Dentistry
- Vol. 49 (2) , 178-188
Surface Degradation of Ion-releasing Restorative Materials With Cariogenic Challenge
SUMMARY: This study examined the influence of cariogenic environments on the surface roughness of ion-releasing restorative materials (IRMs). Custom-made stainless steel molds with holes of 5 mm × 2mm were used to fabricate 60 disc-shaped specimens of each of the following materials: Activa Bioactive (AV), Beautifil Bulk Restorative (BB), Cention N (Bulk-fill) (CN), and Filtek Z350XT (FZ) (Control). Baseline surface roughness (Ra) measurements were obtained using an optical 3D measurement machine (Alicona Imaging GmbH, Graz, Austria). The specimens were then randomly divided into five subgroups (n=12) and exposed to 10 ml of the following mediums at 37°C: distilled water (DW), demineralization solution (DM), remineralization solution (RM), pH cycling (PC) and air (AR) (control). Ra measurements were again recorded after one week and one month, followed by statistical evaluations with two-way analysis of variance (ANOVA) to determine interactions between materials and mediums. One-way ANOVA and post hoc Games Howell tests were performed for intergroup comparisons at a significance level of 0.05. Mean Ra values ranged from 0.085 ± 0.004 (µm) to 0.198 ± 0.001 µm for the various material-medium combinations. All IRMs showed significant differences in Ra values after exposure to the aqueous mediums. The smoothest surfaces were observed in the AR for all materials. When comparing materials, AV presented the roughest surfaces for all mediums. All IRM materials showed increased surface roughness over time in all cariogenic environments but were below the threshold value for bacterial adhesion, except for AV 1-month post immersion with pH cycling. Therefore, besides AV, the surface roughness of IRMs did not deteriorate to an extent that it is clinically relevant.
- 1 March 2024
- Published by Operative Dentistry in Operative Dentistry
- Vol. 49 (2) , 178-188
Surface Degradation of Ion-releasing Restorative Materials With Cariogenic Challenge
SUMMARY: This study examined the influence of cariogenic environments on the surface roughness of ion-releasing restorative materials (IRMs). Custom-made stainless steel molds with holes of 5 mm × 2mm were used to fabricate 60 disc-shaped specimens of each of the following materials: Activa Bioactive (AV), Beautifil Bulk Restorative (BB), Cention N (Bulk-fill) (CN), and Filtek Z350XT (FZ) (Control). Baseline surface roughness (Ra) measurements were obtained using an optical 3D measurement machine (Alicona Imaging GmbH, Graz, Austria). The specimens were then randomly divided into five subgroups (n=12) and exposed to 10 ml of the following mediums at 37°C: distilled water (DW), demineralization solution (DM), remineralization solution (RM), pH cycling (PC) and air (AR) (control). Ra measurements were again recorded after one week and one month, followed by statistical evaluations with two-way analysis of variance (ANOVA) to determine interactions between materials and mediums. One-way ANOVA and post hoc Games Howell tests were performed for intergroup comparisons at a significance level of 0.05. Mean Ra values ranged from 0.085 ± 0.004 (µm) to 0.198 ± 0.001 µm for the various material-medium combinations. All IRMs showed significant differences in Ra values after exposure to the aqueous mediums. The smoothest surfaces were observed in the AR for all materials. When comparing materials, AV presented the roughest surfaces for all mediums. All IRM materials showed increased surface roughness over time in all cariogenic environments but were below the threshold value for bacterial adhesion, except for AV 1-month post immersion with pH cycling. Therefore, besides AV, the surface roughness of IRMs did not deteriorate to an extent that it is clinically relevant.
- 1 June 2021
- Vol. 52 (6) , 476-486
Impact of early biofilm on the assessment of initial enamel erosion with swept-source optical coherence tomography
Objective: This study examined the impact of early biofilm on the tooth surface, during the assessment of initial enamel erosion using swept-source optical coherence tomography (SS-OCT). Method and materials: Forty-five enamel windows of 2 x 4 mm(2) were prepared on 23 extracted human teeth. The specimens were exposed to citric acid (pH 3.2) for 30 minutes and randomly divided into three groups (n = 15): Group 1, no biofilm; Group 2, 1- day-old biofilm; and Group 3, 3-day-old biofilm. Specimens in Groups 2 and 3 were inoculated with oral bacteria (Streptococcus sanguinis, Streptococcus mitis, and Actinomyces naeslundii) to produce early laboratory-cultivated biofilms for 1 and 3 days respectively. Surface microhardness (SMH) measurements were taken at pre- (t(1)) and post-erosion (t(2)); and SS-OCT scans were done at t(1), t(2), and post-biofilm cultivation (t(3)). Integrated reflectivity (IR) of the tooth-air interface (IRsurface) and enamel (IRenamel) were computed from the mean A-scans. Statistical analysis was performed using paired t tests and one-way ANOVA (a =.05). Results: A significant increase in IRenamel was observed at t(2) (P <.05). At t(3), IRsurface between Group 1 (control) and Group 2 (P =.012) as well as Group 3 (P =.001) were significantly different. Significant variances in IR(ename)l were perceived between t(2) and t(3) for Groups 2 and 3 but not for Group 1. Conclusion: As early biofilm affected SS-OCT assessment of initial enamel erosion, they should be removed from the tooth surface prior to OCT procedures.
- 1 June 2021
- Vol. 52 (6) , 476-486
Impact of early biofilm on the assessment of initial enamel erosion with swept-source optical coherence tomography
Objective: This study examined the impact of early biofilm on the tooth surface, during the assessment of initial enamel erosion using swept-source optical coherence tomography (SS-OCT). Method and materials: Forty-five enamel windows of 2 x 4 mm(2) were prepared on 23 extracted human teeth. The specimens were exposed to citric acid (pH 3.2) for 30 minutes and randomly divided into three groups (n = 15): Group 1, no biofilm; Group 2, 1- day-old biofilm; and Group 3, 3-day-old biofilm. Specimens in Groups 2 and 3 were inoculated with oral bacteria (Streptococcus sanguinis, Streptococcus mitis, and Actinomyces naeslundii) to produce early laboratory-cultivated biofilms for 1 and 3 days respectively. Surface microhardness (SMH) measurements were taken at pre- (t(1)) and post-erosion (t(2)); and SS-OCT scans were done at t(1), t(2), and post-biofilm cultivation (t(3)). Integrated reflectivity (IR) of the tooth-air interface (IRsurface) and enamel (IRenamel) were computed from the mean A-scans. Statistical analysis was performed using paired t tests and one-way ANOVA (a =.05). Results: A significant increase in IRenamel was observed at t(2) (P <.05). At t(3), IRsurface between Group 1 (control) and Group 2 (P =.012) as well as Group 3 (P =.001) were significantly different. Significant variances in IR(ename)l were perceived between t(2) and t(3) for Groups 2 and 3 but not for Group 1. Conclusion: As early biofilm affected SS-OCT assessment of initial enamel erosion, they should be removed from the tooth surface prior to OCT procedures.
- 30 September 2019
- Published by Penerbit Universiti Kebangsaan Malaysia (UKM Press) in Sains Malaysiana
- Vol. 48 (9) , 1969-1974
The Association between Epstein-Barr virus (EBV) Past Infection with the Risk of Oral Squamous Cell Carcinoma (OSCC)
- 30 September 2019
- Published by Penerbit Universiti Kebangsaan Malaysia (UKM Press) in Sains Malaysiana
- Vol. 48 (9) , 1969-1974
The Association between Epstein-Barr virus (EBV) Past Infection with the Risk of Oral Squamous Cell Carcinoma (OSCC)