Shiquan Xiong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Shiquan Xiong has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Fazhi Xie
School of Environmental and Energy Engineering, Anhui Jianzhu University, Hefei 230601, China
2 shared publications Juncui Xu
Department of Chemical and Chemical Engineering
2 shared publicationsChuanjie Cai
Key Laboratory of Ion Beam Bioengineering
1 shared publicationDongqing Cai
Key Laboratory of Ion Beam Bioengineering
1 shared publication- Fanglin Liu
Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China; University of Science and Technology of China, Hefei 230026, China
1 shared publication Guilong Zhang
Key Laboratory of Ion Beam Bioengineering
1 shared publication
Latest Publications
- 24 March 2021
- Published by Springer Nature in Electrocatalysis
- Vol. 12 (4) , 381-389
Electroanalysis of Cd2+ and Pb2+ Based on Bi/Fe3O4/RTIL Electrode
- 24 March 2021
- Published by Springer Nature in Electrocatalysis
- Vol. 12 (4) , 381-389
Electroanalysis of Cd2+ and Pb2+ Based on Bi/Fe3O4/RTIL Electrode
- 6 April 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (17) , 2026-2033
Electrochemical detection of Cu( ii ) using amino-functionalized MgFe 2 O 4 /Reduced graphene oxide composite
An amino-functionalized MgFe 2 O 4 /reduced graphene oxide (rGO) was prepared by the combination of MgFe 2 O 4 /rGO and 1,6-hexanediamine, and employed for the electrochemical detection of Cu( ii ) ions.
- 6 April 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (17) , 2026-2033
Electrochemical detection of Cu( ii ) using amino-functionalized MgFe 2 O 4 /Reduced graphene oxide composite
An amino-functionalized MgFe 2 O 4 /reduced graphene oxide (rGO) was prepared by the combination of MgFe 2 O 4 /rGO and 1,6-hexanediamine, and employed for the electrochemical detection of Cu( ii ) ions.
- Open Access
- 10 October 2016
- Published by Springer Nature in Analytical Sciences
- Vol. 32 (10) , 1053-1058
Electrochemical Detection of As(III) by a rGO/Fe3O4-modified Screen-Printed Carbon Electrode
A reduced graphene oxide (rGO)/Fe3O4 composites modified screen-printed carbon electrode (SPCE) was used to determinate As(III) in a HAc-NaAc buffer solution. The rGO/Fe3O4 composites were prepared by a simple and one-pot synthesis method, and characterized by X-ray diffraction (XRD), field emission scanning electron microscopy (SEM), FT-IR and Raman spectra. The electrochemical behaviors of the composite electrode were characterized by cycle voltammetry and electrochemical impedance spectroscopy. The experimental parameters, such as supporting electrolyte, solution pH, deposition potential, deposition time were optimized, respectively. The calibration curve for the detection of As(III) in the range of 2 to 20 ppb was I = -4.495 + 1.922C, with a coefficient of 0.994. The sensitivity was 1.922 μA/ppb, and with about twice Fe3O4 modified SPCE, a detection limit as low as 0.3 ppb was achieved. The proposed electrode was validated by analyzing the As(III) content in real water samples.
- 10 October 2016
- Published by Springer Nature in Analytical Sciences
- Vol. 32 (10) , 1053-1058
Open AccessElectrochemical Detection of As(III) by a rGO/Fe3O4-modified Screen-Printed Carbon Electrode
A reduced graphene oxide (rGO)/Fe3O4 composites modified screen-printed carbon electrode (SPCE) was used to determinate As(III) in a HAc-NaAc buffer solution. The rGO/Fe3O4 composites were prepared by a simple and one-pot synthesis method, and characterized by X-ray diffraction (XRD), field emission scanning electron microscopy (SEM), FT-IR and Raman spectra. The electrochemical behaviors of the composite electrode were characterized by cycle voltammetry and electrochemical impedance spectroscopy. The experimental parameters, such as supporting electrolyte, solution pH, deposition potential, deposition time were optimized, respectively. The calibration curve for the detection of As(III) in the range of 2 to 20 ppb was I = -4.495 + 1.922C, with a coefficient of 0.994. The sensitivity was 1.922 μA/ppb, and with about twice Fe3O4 modified SPCE, a detection limit as low as 0.3 ppb was achieved. The proposed electrode was validated by analyzing the As(III) content in real water samples.
- 13 November 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (2) , 303-310
Preparation of an amino functionalized Fe3O4/Gd2O3 network composite and application in electrochemical detection of Cu2+
A nano-network-structured amino functionalized Gd2O3/Fe3O4 composite was prepared and used as a sensing platform to detect Cu2+.
- 13 November 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (2) , 303-310
Preparation of an amino functionalized Fe3O4/Gd2O3 network composite and application in electrochemical detection of Cu2+
A nano-network-structured amino functionalized Gd2O3/Fe3O4 composite was prepared and used as a sensing platform to detect Cu2+.