Waander L. van Heerde
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Waander L. van Heerde has a total of 156 co-authors. Here are the top co-authors by number of shared publications:
- Saskia E. M. Schols
Department of Hematology Radboud University Medical Center Nijmegen The Netherlands
8 shared publications - Nicole M. A. Blijlevens
Department of Hematology, Radboud University Medical Centre, Nijmegen, The Netherlands
4 shared publications - Aernoud P. Bavinck
Department of Hematology Radboud University Medical Centre Nijmegen The Netherlands
3 shared publications - Amy D. Shapiro
Indiana Hemophilia and Thrombosis Center, Indianapolis, IN
3 shared publications - Johanna G. van der Bom
Department of Clinical Epidemiology Leiden University Medical Center Leiden the Netherlands
3 shared publications - Karin Fijnvandraat
Amsterdam UMC, Pediatric Hematology, University of Amsterdam, Emma Children's Hospital, Amsterdam, Netherlands
3 shared publications
Latest Publications
- Open Access
- 19 June 2026
- Published by Elsevier in Blood Vessels, Thrombosis & Hemostasis
- Vol. 3 (3)
A rapid ADAMTS13 activity assay using a portable readout device.
- 19 June 2026
- Published by Elsevier in Blood Vessels, Thrombosis & Hemostasis
- Vol. 3 (3)
Open AccessA rapid ADAMTS13 activity assay using a portable readout device.
- 28 February 2026
- Published by MyJove Corporation
- No. 228,p. e69701
JoVE Video Dataset
Thrombin and plasmin both play a central role in hemostasis, regulating coagulation and fibrinolysis, respectively. Conventional hemostatic assays often focus on isolated components or limited phases of hemostasis; for example, activated partial thromboplastin time and prothrombin time evaluate only the initiation of fibrin formation, while factor activity assays assess the function of individual coagulation factors. Although valuable, these assays lack a comprehensive view of the overall process of secondary hemostasis and fibrinolysis, which unfolds dynamically over time. The Nijmegen Hemostasis Assay (NHA) addresses this limitation by enabling simultaneous, time-resolved measurement of thrombin and plasmin generation in a single microplate well. Using two synthetic fluorogenic substrates with distinct excitation and emission spectra and no cross-reactivity, the assay allows accurate quantification of both enzymes in parallel. Hemostasis is initiated in platelet-poor plasma using tissue factor, calcium and tissue-type plasminogen activator, and fluorescence is recorded every 30 s over 70 min at 37 °C. Enzyme activity curves are generated using calibration standards, from which parameters such as lag time, thrombin potential, fibrin lysis time, and plasmin peak height are derived. The assay reliably captures simultaneous thrombin and plasmin generation with good intra- and inter-assay precision, and detects modulation of coagulation and fibrinolysis by effectors such as heparin, activated protein C, and epsilon-aminocaproic acid. In clinical samples, significantly reduced thrombin generation was observed in patients with coagulation factor deficiencies, while patients with fibrinolytic disorders showed elevated plasmin generation profiles. By combining thrombin and plasmin generation measurements, the NHA provides a comprehensive insight into the hemostatic balance beyond conventional assays. This integrated approach holds promise for research and clinical applications, such as the characterization of hemostatic phenotypes, assessment of bleeding and thrombotic risk, and monitoring of targeted therapeutic interventions. This protocol outlines the NHA procedure that aims to enhance the understanding and assessment of hemostatic balance.
- 28 February 2026
- Published by MyJove Corporation
- No. 228,p. e69701
JoVE Video Dataset
Thrombin and plasmin both play a central role in hemostasis, regulating coagulation and fibrinolysis, respectively. Conventional hemostatic assays often focus on isolated components or limited phases of hemostasis; for example, activated partial thromboplastin time and prothrombin time evaluate only the initiation of fibrin formation, while factor activity assays assess the function of individual coagulation factors. Although valuable, these assays lack a comprehensive view of the overall process of secondary hemostasis and fibrinolysis, which unfolds dynamically over time. The Nijmegen Hemostasis Assay (NHA) addresses this limitation by enabling simultaneous, time-resolved measurement of thrombin and plasmin generation in a single microplate well. Using two synthetic fluorogenic substrates with distinct excitation and emission spectra and no cross-reactivity, the assay allows accurate quantification of both enzymes in parallel. Hemostasis is initiated in platelet-poor plasma using tissue factor, calcium and tissue-type plasminogen activator, and fluorescence is recorded every 30 s over 70 min at 37 °C. Enzyme activity curves are generated using calibration standards, from which parameters such as lag time, thrombin potential, fibrin lysis time, and plasmin peak height are derived. The assay reliably captures simultaneous thrombin and plasmin generation with good intra- and inter-assay precision, and detects modulation of coagulation and fibrinolysis by effectors such as heparin, activated protein C, and epsilon-aminocaproic acid. In clinical samples, significantly reduced thrombin generation was observed in patients with coagulation factor deficiencies, while patients with fibrinolytic disorders showed elevated plasmin generation profiles. By combining thrombin and plasmin generation measurements, the NHA provides a comprehensive insight into the hemostatic balance beyond conventional assays. This integrated approach holds promise for research and clinical applications, such as the characterization of hemostatic phenotypes, assessment of bleeding and thrombotic risk, and monitoring of targeted therapeutic interventions. This protocol outlines the NHA procedure that aims to enhance the understanding and assessment of hemostatic balance.
- 27 February 2026
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 228,p. e69701
The Nijmegen Hemostasis Assay: Simultaneous Fluorogenic Measurement of Thrombin and Plasmin Generation in a Single Well
Thrombin and plasmin both play a central role in hemostasis, regulating coagulation and fibrinolysis, respectively. Conventional hemostatic assays often focus on isolated components or limited phases of hemostasis; for example, activated partial thromboplastin time and prothrombin time evaluate only the initiation of fibrin formation, while factor activity assays assess the function of individual coagulation factors. Although valuable, these assays lack a comprehensive view of the overall process of secondary hemostasis and fibrinolysis, which unfolds dynamically over time. The Nijmegen Hemostasis Assay (NHA) addresses this limitation by enabling simultaneous, time-resolved measurement of thrombin and plasmin generation in a single microplate well. Using two synthetic fluorogenic substrates with distinct excitation and emission spectra and no cross-reactivity, the assay allows accurate quantification of both enzymes in parallel. Hemostasis is initiated in platelet-poor plasma using tissue factor, calcium and tissue-type plasminogen activator, and fluorescence is recorded every 30 s over 70 min at 37 °C. Enzyme activity curves are generated using calibration standards, from which parameters such as lag time, thrombin potential, fibrin lysis time, and plasmin peak height are derived. The assay reliably captures simultaneous thrombin and plasmin generation with good intra- and inter-assay precision, and detects modulation of coagulation and fibrinolysis by effectors such as heparin, activated protein C, and epsilon-aminocaproic acid. In clinical samples, significantly reduced thrombin generation was observed in patients with coagulation factor deficiencies, while patients with fibrinolytic disorders showed elevated plasmin generation profiles. By combining thrombin and plasmin generation measurements, the NHA provides a comprehensive insight into the hemostatic balance beyond conventional assays. This integrated approach holds promise for research and clinical applications, such as the characterization of hemostatic phenotypes, assessment of bleeding and thrombotic risk, and monitoring of targeted therapeutic interventions. This protocol outlines the NHA procedure that aims to enhance the understanding and assessment of hemostatic balance.
- 27 February 2026
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 228,p. e69701
The Nijmegen Hemostasis Assay: Simultaneous Fluorogenic Measurement of Thrombin and Plasmin Generation in a Single Well
Thrombin and plasmin both play a central role in hemostasis, regulating coagulation and fibrinolysis, respectively. Conventional hemostatic assays often focus on isolated components or limited phases of hemostasis; for example, activated partial thromboplastin time and prothrombin time evaluate only the initiation of fibrin formation, while factor activity assays assess the function of individual coagulation factors. Although valuable, these assays lack a comprehensive view of the overall process of secondary hemostasis and fibrinolysis, which unfolds dynamically over time. The Nijmegen Hemostasis Assay (NHA) addresses this limitation by enabling simultaneous, time-resolved measurement of thrombin and plasmin generation in a single microplate well. Using two synthetic fluorogenic substrates with distinct excitation and emission spectra and no cross-reactivity, the assay allows accurate quantification of both enzymes in parallel. Hemostasis is initiated in platelet-poor plasma using tissue factor, calcium and tissue-type plasminogen activator, and fluorescence is recorded every 30 s over 70 min at 37 °C. Enzyme activity curves are generated using calibration standards, from which parameters such as lag time, thrombin potential, fibrin lysis time, and plasmin peak height are derived. The assay reliably captures simultaneous thrombin and plasmin generation with good intra- and inter-assay precision, and detects modulation of coagulation and fibrinolysis by effectors such as heparin, activated protein C, and epsilon-aminocaproic acid. In clinical samples, significantly reduced thrombin generation was observed in patients with coagulation factor deficiencies, while patients with fibrinolytic disorders showed elevated plasmin generation profiles. By combining thrombin and plasmin generation measurements, the NHA provides a comprehensive insight into the hemostatic balance beyond conventional assays. This integrated approach holds promise for research and clinical applications, such as the characterization of hemostatic phenotypes, assessment of bleeding and thrombotic risk, and monitoring of targeted therapeutic interventions. This protocol outlines the NHA procedure that aims to enhance the understanding and assessment of hemostatic balance.
- Open Access
- 17 December 2025
- Published by Wiley in Haemophilia
- Vol. 32 (2) , 481-489
Acceptability and Determinants for Implementation of the EnzySystem, a Novel Near‐Patient Testing Platform for Haemophilia A
Introduction: Coagulation testing in haemophilia A is limited by the scarcity of testing facilities capable of performing relevant assays. This issue incentivized the development of the EnzySystem for haemophilia A, a near‐patient testing platform aimed to measure Factor VIII activity and thrombin generation simultaneously within 1 h from 100 µL of whole blood. Involving end‐users throughout the development ensures innovations are well‐suited to meet real‐world clinical needs. Aim: To determine EnzySystem's acceptance, envisioned use scenarios and determinants for implementation according to healthcare providers (HCPs) and persons with haemophilia A and caregivers (PwHA/C). Methods: A single‐centre, cross‐sectional mixed methods study was performed involving two participant groups. The first involved 36 PwHA/C. The second group comprised five advanced practice providers, eight nurses, four pharmacists and five haematologists, all involved in haemophilia A care. The participants’ attitudes and preferences toward the EnzySystem for haemophilia A were assessed through questionnaires and focus groups. Results: Acceptability was high for both groups. The platform was considered suitable for use in various scenarios, but self‐testing at home was prioritized by PwHA/C. HCPs placed equal emphasis on near‐patient testing in clinic to address issues with current test accessibility and turnaround time. For all potential use scenarios, demonstrating assay accuracy was a non‐negotiable prerequisite. The turnaround time and accessibility were identified as other key attributes by both groups. Conclusion: The results of this study support the further development of the EnzySystem for haemophilia A and highlight barriers that should be addressed to facilitate implementation.
- 17 December 2025
- Published by Wiley in Haemophilia
- Vol. 32 (2) , 481-489
Open AccessAcceptability and Determinants for Implementation of the EnzySystem, a Novel Near‐Patient Testing Platform for Haemophilia A
Introduction: Coagulation testing in haemophilia A is limited by the scarcity of testing facilities capable of performing relevant assays. This issue incentivized the development of the EnzySystem for haemophilia A, a near‐patient testing platform aimed to measure Factor VIII activity and thrombin generation simultaneously within 1 h from 100 µL of whole blood. Involving end‐users throughout the development ensures innovations are well‐suited to meet real‐world clinical needs. Aim: To determine EnzySystem's acceptance, envisioned use scenarios and determinants for implementation according to healthcare providers (HCPs) and persons with haemophilia A and caregivers (PwHA/C). Methods: A single‐centre, cross‐sectional mixed methods study was performed involving two participant groups. The first involved 36 PwHA/C. The second group comprised five advanced practice providers, eight nurses, four pharmacists and five haematologists, all involved in haemophilia A care. The participants’ attitudes and preferences toward the EnzySystem for haemophilia A were assessed through questionnaires and focus groups. Results: Acceptability was high for both groups. The platform was considered suitable for use in various scenarios, but self‐testing at home was prioritized by PwHA/C. HCPs placed equal emphasis on near‐patient testing in clinic to address issues with current test accessibility and turnaround time. For all potential use scenarios, demonstrating assay accuracy was a non‐negotiable prerequisite. The turnaround time and accessibility were identified as other key attributes by both groups. Conclusion: The results of this study support the further development of the EnzySystem for haemophilia A and highlight barriers that should be addressed to facilitate implementation.
- Open Access
- 16 October 2025
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 9 (1) , e77621
Measuring FVIII Activity and Thrombin Generation Simultaneously With a Novel Point of Care Platform (EnzySystem HemA): Qualitative Usability Evaluation
Background: Hemophilia A is an inherited bleeding disorder with an increased risk of excessive bleeding. People affected by hemophilia A with a severe bleeding phenotype are treated prophylactically with hemostatic agents. Monitoring treatment and adjusting it to the individual patient’s needs is complicated by the scarcity of laboratories equipped to perform relevant coagulation assays and the absence of point-of-care testing platforms. A novel near-patient testing platform called the EnzySystem HemA aims to address this issue by measuring factor VIII (FVIII) activity and thrombin generation within 1 hour of 100 µL of whole blood. Objective: This study assessed the usability of the EnzySystem HemA by health care professionals without prior training and gathered information on its perceived usability, effectiveness, usefulness, and acceptability. Methods: A qualitative, single-center formative usability assessment was performed. Participants performed an FVIII activity assay with a mockup of the EnzySystem HemA and were interviewed about its acceptability, usability, effectiveness, and usefulness. Video recordings of the sessions were obtained with permission and subsequently reviewed to assess usability; thematic analysis was performed on the interview transcripts. Results: A total of 7 health care providers participated, all unaffiliated with the EnzySystem’s developer. Participants included 1 (14%) pediatric hematologist, 3 (43%; pediatric) nurses, and 3 (43%; pediatric) nurse practitioners. Two (29%) of the participants also held management positions. Five (71%) participants successfully performed the FVIII activity assay as intended. Of the remaining 2 participants, one applied insufficient force when inserting the blood tube, whereas the other was unable to transfer the blood into the EnzySystem. This latter step caused difficulties in 3 (60%) other participants; however, they completed it correctly. Five (71%) participants did not dispose of the EnzySystem components as intended, primarily due to compatibility issues of the disposable parts with the inlet of the US standard medical waste containers. Five themes were generated from the interviews: functional the way it is focuses on the acceptance of the prototype despite suggestions for various improvements, utility through faster results and increased access and potential for patient engagement relate to the envisioned benefits of the platform, and financial investment and return and ensuring accuracy reflect on potential barriers for implementation. Conclusions: Despite significant usability issues, the need for faster and more accessible testing led participants to conclude that the current platform was acceptable for use, provided that proof of assay accuracy was demonstrated. The results of this study will form the basis for further development of the EnzySystem HemA. The effectiveness of any updates will be evaluated in future usability studies, which will also include people with hemophilia A as participants.
- 16 October 2025
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 9 (1) , e77621
Open AccessMeasuring FVIII Activity and Thrombin Generation Simultaneously With a Novel Point of Care Platform (EnzySystem HemA): Qualitative Usability Evaluation
Background: Hemophilia A is an inherited bleeding disorder with an increased risk of excessive bleeding. People affected by hemophilia A with a severe bleeding phenotype are treated prophylactically with hemostatic agents. Monitoring treatment and adjusting it to the individual patient’s needs is complicated by the scarcity of laboratories equipped to perform relevant coagulation assays and the absence of point-of-care testing platforms. A novel near-patient testing platform called the EnzySystem HemA aims to address this issue by measuring factor VIII (FVIII) activity and thrombin generation within 1 hour of 100 µL of whole blood. Objective: This study assessed the usability of the EnzySystem HemA by health care professionals without prior training and gathered information on its perceived usability, effectiveness, usefulness, and acceptability. Methods: A qualitative, single-center formative usability assessment was performed. Participants performed an FVIII activity assay with a mockup of the EnzySystem HemA and were interviewed about its acceptability, usability, effectiveness, and usefulness. Video recordings of the sessions were obtained with permission and subsequently reviewed to assess usability; thematic analysis was performed on the interview transcripts. Results: A total of 7 health care providers participated, all unaffiliated with the EnzySystem’s developer. Participants included 1 (14%) pediatric hematologist, 3 (43%; pediatric) nurses, and 3 (43%; pediatric) nurse practitioners. Two (29%) of the participants also held management positions. Five (71%) participants successfully performed the FVIII activity assay as intended. Of the remaining 2 participants, one applied insufficient force when inserting the blood tube, whereas the other was unable to transfer the blood into the EnzySystem. This latter step caused difficulties in 3 (60%) other participants; however, they completed it correctly. Five (71%) participants did not dispose of the EnzySystem components as intended, primarily due to compatibility issues of the disposable parts with the inlet of the US standard medical waste containers. Five themes were generated from the interviews: functional the way it is focuses on the acceptance of the prototype despite suggestions for various improvements, utility through faster results and increased access and potential for patient engagement relate to the envisioned benefits of the platform, and financial investment and return and ensuring accuracy reflect on potential barriers for implementation. Conclusions: Despite significant usability issues, the need for faster and more accessible testing led participants to conclude that the current platform was acceptable for use, provided that proof of assay accuracy was demonstrated. The results of this study will form the basis for further development of the EnzySystem HemA. The effectiveness of any updates will be evaluated in future usability studies, which will also include people with hemophilia A as participants.
- Open Access
- 21 July 2025
- Published by Elsevier in Journal of Thrombosis and Haemostasis
- Vol. 23 (10) , 3124-3133
Impaired tolerance in the International Immune Tolerance Induction study due to the presence of very low-titer inhibitors
- 21 July 2025
- Published by Elsevier in Journal of Thrombosis and Haemostasis
- Vol. 23 (10) , 3124-3133
Open AccessImpaired tolerance in the International Immune Tolerance Induction study due to the presence of very low-titer inhibitors
- Open Access
- 16 May 2025
- Published by JMIR Publications Inc. in JMIR Preprints
The EnzySystem HemA, a novel point-of-care platform to measure FVIII activity and Thrombin Generation simultaneously: Qualitative usability evaluation (Preprint)
BACKGROUND Hemophilia A is an inherited bleeding disorder with an increased risk of excessive bleeding. People affected by hemophilia A with a severe bleeding phenotype are treated prophylactically with hemostatic agents. Monitoring treatment and adjusting it to the individual patient’s needs is complicated by the scarcity of laboratories equipped to perform relevant coagulation assays and the absence of point-of-care testing platforms. A novel near-patient testing platform called the EnzySystem HemA aims to address this issue by measuring Factor VIII activity and Thrombin Generation within one hour out of 100 µL of whole blood. OBJECTIVE This study assessed the usability of the EnzySystem HemA by healthcare professionals without prior training and gathered information on its perceived usability, effectiveness, usefulness, and acceptability. METHODS A qualitative, single-center formative usability assessment was performed. Seven healthcare providers participated, all unaffiliated with the EnzySystem’s developer (Enzyre). Participants included one pediatric hematologist, three (pediatric) nurses, and three (pediatric) nurse practitioners. Two of the participants also held management positions. Participants performed a FVIII activity assay with a mockup of the EnzySystem HemA and were interviewed about its acceptability, usability, effectiveness, and usefulness. Video recordings of the sessions were obtained with permission and subsequently reviewed to assess usability; thematic analysis was performed on the interview transcripts. RESULTS Five participants (71%, 5/7) successfully performed the FVIII activity assay as intended. Of the remaining two participants, one applied insufficient force when inserting the blood tube, while the other was unable to transfer the blood into the EnzySystem. This latter step caused difficulties in three other participants, however they completed it correctly. Five participants (71%, 5/7) did not dispose of the EnzySystem components as intended, primarily due to compatibility issues of the disposable parts with the inlet of US standard medical waste containers. Five themes were generated from the interviews: “Functional the way it is” focuses on the acceptance of the prototype despite suggestions for various improvements; “Utility through faster results and increased access” and “Potential for patient engagement” relate to the envisioned benefits of the platform; and “Financial investment and return” and “Ensuring accuracy” reflect on potential barriers for implementation. CONCLUSIONS Despite significant usability issues, the need for faster and more accessible testing led participants to conclude that the current platform was acceptable for use, provided that proof of assay accuracy was demonstrated. The results of this study will form the basis for further development of the EnzySystem HemA. The effectiveness of any updates will be evaluated in future usability studies, which will also include people with hemophilia A as participants. CLINICALTRIAL
- 16 May 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessThe EnzySystem HemA, a novel point-of-care platform to measure FVIII activity and Thrombin Generation simultaneously: Qualitative usability evaluation (Preprint)
BACKGROUND Hemophilia A is an inherited bleeding disorder with an increased risk of excessive bleeding. People affected by hemophilia A with a severe bleeding phenotype are treated prophylactically with hemostatic agents. Monitoring treatment and adjusting it to the individual patient’s needs is complicated by the scarcity of laboratories equipped to perform relevant coagulation assays and the absence of point-of-care testing platforms. A novel near-patient testing platform called the EnzySystem HemA aims to address this issue by measuring Factor VIII activity and Thrombin Generation within one hour out of 100 µL of whole blood. OBJECTIVE This study assessed the usability of the EnzySystem HemA by healthcare professionals without prior training and gathered information on its perceived usability, effectiveness, usefulness, and acceptability. METHODS A qualitative, single-center formative usability assessment was performed. Seven healthcare providers participated, all unaffiliated with the EnzySystem’s developer (Enzyre). Participants included one pediatric hematologist, three (pediatric) nurses, and three (pediatric) nurse practitioners. Two of the participants also held management positions. Participants performed a FVIII activity assay with a mockup of the EnzySystem HemA and were interviewed about its acceptability, usability, effectiveness, and usefulness. Video recordings of the sessions were obtained with permission and subsequently reviewed to assess usability; thematic analysis was performed on the interview transcripts. RESULTS Five participants (71%, 5/7) successfully performed the FVIII activity assay as intended. Of the remaining two participants, one applied insufficient force when inserting the blood tube, while the other was unable to transfer the blood into the EnzySystem. This latter step caused difficulties in three other participants, however they completed it correctly. Five participants (71%, 5/7) did not dispose of the EnzySystem components as intended, primarily due to compatibility issues of the disposable parts with the inlet of US standard medical waste containers. Five themes were generated from the interviews: “Functional the way it is” focuses on the acceptance of the prototype despite suggestions for various improvements; “Utility through faster results and increased access” and “Potential for patient engagement” relate to the envisioned benefits of the platform; and “Financial investment and return” and “Ensuring accuracy” reflect on potential barriers for implementation. CONCLUSIONS Despite significant usability issues, the need for faster and more accessible testing led participants to conclude that the current platform was acceptable for use, provided that proof of assay accuracy was demonstrated. The results of this study will form the basis for further development of the EnzySystem HemA. The effectiveness of any updates will be evaluated in future usability studies, which will also include people with hemophilia A as participants. CLINICALTRIAL
- Open Access
- 25 April 2025
- Published by American Society of Hematology in Blood
- Vol. 146 (3) , 369-381
Clinical phenotype and pathophysiological mechanisms underlying qualitative Low VWF
Previous reports have highlighted that some low VWF patients with significant bleeding were diagnosed based upon an isolated but persistent reduction in plasma VWF activity levels in the 30-50 IU/dL range. These patients had plasma VWF:Ag levels > 50 IU/dL and thus had 'qualitative' rather than 'quantitative' low VWF. Although the clinical importance of functional VWF defects in type 2 VWD is well recognized, the translational implications of mild functional defects in patients with qualitative low VWF (low VWF-QL) have not been defined. To address this clinically important question, we combined low VWF datasets from the low VWF in Ireland cohort and the low VWF in Erasmus MC studies. Overall, we observed that low VWF-QL was common and accounted for approximately 50% of our combined low VWF cohort. Importantly, our findings demonstrate that many of these patients with mild isolated functional VWF defects in the 30-50 IU/dl range had significant bleeding phenotypes, even though their plasma VWF:Ag levels were within the normal range. In addition, we further show that low VWF-QL is a distinct clinic-pathological entity compared to type 2 VWD. Finally, our studies highlight that low VWF-QL is predominantly due to abnormalities in VWF biosynthesis within endothelial cells that are occurring largely independent of identifiable pathological VWF sequence variants. Cumulatively, these novel observations have important clinical implications for the diagnosis and management of patients with mild functional VWF defects.
- 25 April 2025
- Published by American Society of Hematology in Blood
- Vol. 146 (3) , 369-381
Open AccessClinical phenotype and pathophysiological mechanisms underlying qualitative Low VWF
Previous reports have highlighted that some low VWF patients with significant bleeding were diagnosed based upon an isolated but persistent reduction in plasma VWF activity levels in the 30-50 IU/dL range. These patients had plasma VWF:Ag levels > 50 IU/dL and thus had 'qualitative' rather than 'quantitative' low VWF. Although the clinical importance of functional VWF defects in type 2 VWD is well recognized, the translational implications of mild functional defects in patients with qualitative low VWF (low VWF-QL) have not been defined. To address this clinically important question, we combined low VWF datasets from the low VWF in Ireland cohort and the low VWF in Erasmus MC studies. Overall, we observed that low VWF-QL was common and accounted for approximately 50% of our combined low VWF cohort. Importantly, our findings demonstrate that many of these patients with mild isolated functional VWF defects in the 30-50 IU/dl range had significant bleeding phenotypes, even though their plasma VWF:Ag levels were within the normal range. In addition, we further show that low VWF-QL is a distinct clinic-pathological entity compared to type 2 VWD. Finally, our studies highlight that low VWF-QL is predominantly due to abnormalities in VWF biosynthesis within endothelial cells that are occurring largely independent of identifiable pathological VWF sequence variants. Cumulatively, these novel observations have important clinical implications for the diagnosis and management of patients with mild functional VWF defects.
- 17 April 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 282, 117469
Novel microfluidic device for factor VIII quantification by chemiluminescence in hemophilia A patients
- 17 April 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 282, 117469
Novel microfluidic device for factor VIII quantification by chemiluminescence in hemophilia A patients
- Open Access
- 17 February 2024
- Published by Springer Nature in European Journal of Drug Metabolism and Pharmacokinetics
- Vol. 49 (2) , 191-205
Pharmacokinetic–Pharmacodynamic Modelling in Hemophilia A: Relating Thrombin and Plasmin Generation to Factor VIII Activity After Administration of a VWF/FVIII Concentrate
Background Hemophilia A patients are treated with factor (F) VIII prophylactically to prevent bleeding. In general, dosage and frequency are based on pharmacokinetic measurements. Ideally, an alternative dose adjustment can be based on the hemostatic potential, measured with a thrombin generation assay (TGA), like the Nijmegen hemostasis assay. Objective The objective of this study was to investigate the predicted performance of a previously developed pharmacokinetic–pharmacodynamic model for FVIII replacement therapy, relating FVIII dose and FVIII activity levels with thrombin and plasmin generation parameters. Methods Pharmacokinetic and pharmacodynamic measurements were obtained from 29 severe hemophilia A patients treated with pdVWF/FVIII concentrate (Haemate P®). The predictive performance of the previously developed pharmacokinetic–pharmacodynamic model was evaluated using nonlinear mixed-effects modeling (NONMEM). When predictions of FVIII activity or TGA parameters were inadequate [median prediction error (MPE) > 20%], a new model was developed. Results The original pharmacokinetic model underestimated clearance and was refined based on a two-compartment model. The pharmacodynamic model displays no bias in the observed normalized thrombin peak height and normalized thrombin potential (MPE of 6.83% and 7.46%). After re-estimating pharmacodynamic parameters, EC50 and Emax values were relatively comparable between the original model and this group. Prediction of normalized plasmin peak height was inaccurate (MPE 58.9%). Conclusion Our predictive performance displayed adequate thrombin pharmacodynamic predictions of the original model, but a new pharmacokinetic model was required. The pharmacodynamic model is not factor specific and applicable to multiple factor concentrates. A prospective study is needed to validate the impact of the FVIII dosing pharmacodynamic model on bleeding reduction in patients.
- 17 February 2024
- Published by Springer Nature in European Journal of Drug Metabolism and Pharmacokinetics
- Vol. 49 (2) , 191-205
Open AccessPharmacokinetic–Pharmacodynamic Modelling in Hemophilia A: Relating Thrombin and Plasmin Generation to Factor VIII Activity After Administration of a VWF/FVIII Concentrate
Background Hemophilia A patients are treated with factor (F) VIII prophylactically to prevent bleeding. In general, dosage and frequency are based on pharmacokinetic measurements. Ideally, an alternative dose adjustment can be based on the hemostatic potential, measured with a thrombin generation assay (TGA), like the Nijmegen hemostasis assay. Objective The objective of this study was to investigate the predicted performance of a previously developed pharmacokinetic–pharmacodynamic model for FVIII replacement therapy, relating FVIII dose and FVIII activity levels with thrombin and plasmin generation parameters. Methods Pharmacokinetic and pharmacodynamic measurements were obtained from 29 severe hemophilia A patients treated with pdVWF/FVIII concentrate (Haemate P®). The predictive performance of the previously developed pharmacokinetic–pharmacodynamic model was evaluated using nonlinear mixed-effects modeling (NONMEM). When predictions of FVIII activity or TGA parameters were inadequate [median prediction error (MPE) > 20%], a new model was developed. Results The original pharmacokinetic model underestimated clearance and was refined based on a two-compartment model. The pharmacodynamic model displays no bias in the observed normalized thrombin peak height and normalized thrombin potential (MPE of 6.83% and 7.46%). After re-estimating pharmacodynamic parameters, EC50 and Emax values were relatively comparable between the original model and this group. Prediction of normalized plasmin peak height was inaccurate (MPE 58.9%). Conclusion Our predictive performance displayed adequate thrombin pharmacodynamic predictions of the original model, but a new pharmacokinetic model was required. The pharmacodynamic model is not factor specific and applicable to multiple factor concentrates. A prospective study is needed to validate the impact of the FVIII dosing pharmacodynamic model on bleeding reduction in patients.