Ali Sahin Tasligedik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ali Sahin Tasligedik has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Palermo
Department of Civil and Natural Resources Engineering, University of Canterbury, Christchurch, New Zealand
5 shared publications Stefano Pampanin
Department of Civil and Natural Resources Engineering, University of Canterbury, Christchurch, New Zealand
4 shared publications- Stefano Pampanin
Department of Structural and Geotechnical Engineering Sapienza University of Rome Rome Italy
3 shared publications Andrew Baird
BECA, Auckland, New Zealand
2 shared publications- Egemen Sönmez
İzmir University of Economics
2 shared publications - Fırat Sondilek
Middle East Technical University Northern Cyprus Campus
2 shared publications
Latest Publications
- 3 September 2024
- Published by Springer Nature
- p. 11-23
Effect of Column-to-Beam Strength Ratio on the Performance of Code-Conforming Frame Buildings for 2023 Türkiye Earthquakes
- 3 September 2024
- Published by Springer Nature
- p. 11-23
Effect of Column-to-Beam Strength Ratio on the Performance of Code-Conforming Frame Buildings for 2023 Türkiye Earthquakes
- 29 April 2024
- Published by Springer Nature
- p. 296-306
Effect of Column-to-Beam Strength Ratio Distribution on the Seismic Behavior of Reinforced Concrete Frame Structures
- 29 April 2024
- Published by Springer Nature
- p. 296-306
Effect of Column-to-Beam Strength Ratio Distribution on the Seismic Behavior of Reinforced Concrete Frame Structures
- 30 March 2023
- Published by Golden Light Publishing in Journal of Structural Engineering & Applied Mechanics
- Vol. 6 (1) , 1-9
State-of-art summary of the strength hierarchy assessment and its applications
Strength hierarchy assessment is a method developed to be able to identify the governing failure mechanisms at reinforced concrete (RC) beam-column joints. The main failures that can be identified in this method are: i) beam plastic hinge; ii) column plastic hinge/shear failure; iii) beam-column joint shear failure. Through the identification of the governing failure mode in a joint, the validity of the capacity design principles can be checked for the considered RC beam-column joint. The obtained observations can then be used in finding the most optimal repair/strengthening application. This method has been going through updates and developments in the last decade and new applications have emerged. In this article, a state-of-the-art summary of the procedure is reported with its most recent updates as well as its practical engineering applications.
- 30 March 2023
- Published by Golden Light Publishing in Journal of Structural Engineering & Applied Mechanics
- Vol. 6 (1) , 1-9
State-of-art summary of the strength hierarchy assessment and its applications
Strength hierarchy assessment is a method developed to be able to identify the governing failure mechanisms at reinforced concrete (RC) beam-column joints. The main failures that can be identified in this method are: i) beam plastic hinge; ii) column plastic hinge/shear failure; iii) beam-column joint shear failure. Through the identification of the governing failure mode in a joint, the validity of the capacity design principles can be checked for the considered RC beam-column joint. The obtained observations can then be used in finding the most optimal repair/strengthening application. This method has been going through updates and developments in the last decade and new applications have emerged. In this article, a state-of-the-art summary of the procedure is reported with its most recent updates as well as its practical engineering applications.
- 22 June 2020
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 26 (5) , 2194-2224
Shear Capacity N-M Interaction Envelope for RC Beam-Column Joints with Transverse Reinforcement: A Concept Derived from Strength Hierarchy
Strength hierarchy assessment method is a capacity analysis procedure that can be used to identify the sequence of failures likely to occur within reinforced concrete (RC) frame buildings under lateral actions such as earthquakes or wind loads. Previous publication on this method mainly focused on the application of this method to (a) the vulnerable RC beam-column joints without any joint shear reinforcement where principal tensile stresses were considered critical, (b) modern RC beam-column joints with joint shear reinforcement where extreme principal compression stresses were considered critical. In this paper, joint shear capacity representation for modern RC beam-column joints (with transverse reinforcements in the joint) is generalized to include both critical components: principal tensile and principal compression stresses. Using strength hierarchy assessment, the investigation showed that it is possible to express the joint shear capacity as an N-M interaction envelope analogous to the N-M interaction of columns. The resulting joint shear capacity N-M interaction concept is validated using a database of 22 external and 22 internal RC beam-column joint tests with joint shear reinforcement at their joint core which resulted in joint shear failure in their tests. Considering the importance of axial load levels on the expected performance of RC beam-column joints, the proposed concept can be used for the general assessment of the joint shear capacity or for beam-column joint modeling purposes, which can be practically used by the design engineers.
- 22 June 2020
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 26 (5) , 2194-2224
Shear Capacity N-M Interaction Envelope for RC Beam-Column Joints with Transverse Reinforcement: A Concept Derived from Strength Hierarchy
Strength hierarchy assessment method is a capacity analysis procedure that can be used to identify the sequence of failures likely to occur within reinforced concrete (RC) frame buildings under lateral actions such as earthquakes or wind loads. Previous publication on this method mainly focused on the application of this method to (a) the vulnerable RC beam-column joints without any joint shear reinforcement where principal tensile stresses were considered critical, (b) modern RC beam-column joints with joint shear reinforcement where extreme principal compression stresses were considered critical. In this paper, joint shear capacity representation for modern RC beam-column joints (with transverse reinforcements in the joint) is generalized to include both critical components: principal tensile and principal compression stresses. Using strength hierarchy assessment, the investigation showed that it is possible to express the joint shear capacity as an N-M interaction envelope analogous to the N-M interaction of columns. The resulting joint shear capacity N-M interaction concept is validated using a database of 22 external and 22 internal RC beam-column joint tests with joint shear reinforcement at their joint core which resulted in joint shear failure in their tests. Considering the importance of axial load levels on the expected performance of RC beam-column joints, the proposed concept can be used for the general assessment of the joint shear capacity or for beam-column joint modeling purposes, which can be practically used by the design engineers.
- 1 November 2017
- Published by Wiley in Earthquake Spectra
- Vol. 33 (4) , 1627-1654
Fully Floating Suspended Ceiling System: Experimental Evaluation of Structural Feasibility and Challenges
Full scale shake table testing is conducted on a novel type of suspended ceiling called fully floating ceiling system, which is freely hung from the floor above lacking any lateral bracing and connections with the perimeters. A gap is provided on all sides of the ceiling. Throughout different tests, a satisfactory agreement between the fully floating ceiling response and simple pendulum theory was demonstrated. When subjected to input motions with significant energy in the floating ceiling's resonant frequency, the horizontal displacement of the ceiling exceeded the gap width resulting in pounding induced large acceleration pulses. To mitigate such effects, the perimeter gap fillers of a compressible material are proposed. The addition of perimeter isolation was found effective in inducing extra damping and protecting the ceiling from pounding impact; resulting in much reduced ceiling displacements and accelerations. Throughout the tests a single panel dislodgement was observed as the only instance of damage.
- 1 November 2017
- Published by Wiley in Earthquake Spectra
- Vol. 33 (4) , 1627-1654
Fully Floating Suspended Ceiling System: Experimental Evaluation of Structural Feasibility and Challenges
Full scale shake table testing is conducted on a novel type of suspended ceiling called fully floating ceiling system, which is freely hung from the floor above lacking any lateral bracing and connections with the perimeters. A gap is provided on all sides of the ceiling. Throughout different tests, a satisfactory agreement between the fully floating ceiling response and simple pendulum theory was demonstrated. When subjected to input motions with significant energy in the floating ceiling's resonant frequency, the horizontal displacement of the ceiling exceeded the gap width resulting in pounding induced large acceleration pulses. To mitigate such effects, the perimeter gap fillers of a compressible material are proposed. The addition of perimeter isolation was found effective in inducing extra damping and protecting the ceiling from pounding impact; resulting in much reduced ceiling displacements and accelerations. Throughout the tests a single panel dislodgement was observed as the only instance of damage.
- 26 October 2017
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 16 (3) , 1323-1340
Capacity estimation of FRP strengthened RC beam-column joints using hierarchy of strength assessment
- 26 October 2017
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 16 (3) , 1323-1340
Capacity estimation of FRP strengthened RC beam-column joints using hierarchy of strength assessment
- 28 November 2016
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 22 (3) , 454-487
Strength Hierarchy at Reinforced Concrete Beam-Column Joints and Global Capacity
Strength hierarchy assessment is a method that can be utilized to identify the weakest structural element at a reinforced concrete (RC) beam-column joint. The method was extensively used in various research activities at the University of Canterbury, which mainly involved beam-column joint subassembly tests. However, this method required improvements and refinements in order to be adopted in multi-story building applications. In this paper, the improvements made to the method are reported. In the improved method, capacity of the weakest element at every beam-column joint in an RC frame building can be related to the corresponding global base shear demand. The method has been illustrated via two example applications: an RC frame lacking joint shear reinforcement and a modern RC frame with adequate joint shear reinforcement. The case study examples confirmed the accuracy and the effectiveness of the method.
- 28 November 2016
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 22 (3) , 454-487
Strength Hierarchy at Reinforced Concrete Beam-Column Joints and Global Capacity
Strength hierarchy assessment is a method that can be utilized to identify the weakest structural element at a reinforced concrete (RC) beam-column joint. The method was extensively used in various research activities at the University of Canterbury, which mainly involved beam-column joint subassembly tests. However, this method required improvements and refinements in order to be adopted in multi-story building applications. In this paper, the improvements made to the method are reported. In the improved method, capacity of the weakest element at every beam-column joint in an RC frame building can be related to the corresponding global base shear demand. The method has been illustrated via two example applications: an RC frame lacking joint shear reinforcement and a modern RC frame with adequate joint shear reinforcement. The case study examples confirmed the accuracy and the effectiveness of the method.
- 27 July 2016
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 21 (7) , 1023-1049
Rocking Cantilever Clay Brick Infill Wall Panels: A Novel Low Damage Infill Wall System
In this article, the development of a new low damage clay brick infill wall system has been reported. The solution enables an engineer to control the drift level after which the infill wall damage can be allowed. This is achieved by utilizing a system of individual rocking clay brick infill panels rather than a single squat infill wall, which minimizes the interaction between the infill wall and the structural system until a selected design drift level. The solution is a workaround for the controversial aspects of clay brick infill walls, which are brittleness, or lack of deformability/ductility and unreliable strength. The seismic performances of an as-built unreinforced clay brick infill wall and the developed low damage clay brick infill wall system were evaluated by 2D quasi static tests. The results were calibrated and used for the analysis of a typical New Zealand building model in order to observe the effects of the as-built and the low damage infill wall systems on the maximum inter-story drift profiles of the structure. Past design codes consider infill walls within frame buildings as non-structural elements; thus, these walls have been typically neglected in the analysis of a building. The observations made after major earthquakes in recent years have repeatedly shown that infill walls interact with the structural system during seismic actions and modify the behavior of the structure. More recent code design provisions recognize the complexity of such interactions and require either (a) consider these effects of frame-infill interaction during the design and modeling phase or (b) assure no or low-interaction of the two systems with proper detailing and arrangements in the construction phase. To consider the interaction in the design stage can be impractical and in most cases does not solve the actual problem related to their brittle behavior. On the other hand, considering the low interaction, not much technical information/design guide is available to the engineers, which is the problem tackled in this article.
- 27 July 2016
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 21 (7) , 1023-1049
Rocking Cantilever Clay Brick Infill Wall Panels: A Novel Low Damage Infill Wall System
In this article, the development of a new low damage clay brick infill wall system has been reported. The solution enables an engineer to control the drift level after which the infill wall damage can be allowed. This is achieved by utilizing a system of individual rocking clay brick infill panels rather than a single squat infill wall, which minimizes the interaction between the infill wall and the structural system until a selected design drift level. The solution is a workaround for the controversial aspects of clay brick infill walls, which are brittleness, or lack of deformability/ductility and unreliable strength. The seismic performances of an as-built unreinforced clay brick infill wall and the developed low damage clay brick infill wall system were evaluated by 2D quasi static tests. The results were calibrated and used for the analysis of a typical New Zealand building model in order to observe the effects of the as-built and the low damage infill wall systems on the maximum inter-story drift profiles of the structure. Past design codes consider infill walls within frame buildings as non-structural elements; thus, these walls have been typically neglected in the analysis of a building. The observations made after major earthquakes in recent years have repeatedly shown that infill walls interact with the structural system during seismic actions and modify the behavior of the structure. More recent code design provisions recognize the complexity of such interactions and require either (a) consider these effects of frame-infill interaction during the design and modeling phase or (b) assure no or low-interaction of the two systems with proper detailing and arrangements in the construction phase. To consider the interaction in the design stage can be impractical and in most cases does not solve the actual problem related to their brittle behavior. On the other hand, considering the low interaction, not much technical information/design guide is available to the engineers, which is the problem tackled in this article.
- 1 March 2016
- Published by Springer Nature in Earthquake Engineering and Engineering Vibration
- Vol. 15 (1) , 1-17
Seismic performance of non-structural components and contents in buildings: an overview of NZ research
- 1 March 2016
- Published by Springer Nature in Earthquake Engineering and Engineering Vibration
- Vol. 15 (1) , 1-17
Seismic performance of non-structural components and contents in buildings: an overview of NZ research
- 30 July 2014
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 13 (4) , 1029-1050
Low damage seismic solutions for non-structural drywall partitions
- 30 July 2014
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 13 (4) , 1029-1050
Low damage seismic solutions for non-structural drywall partitions