Rodrigo Sergio Wiederkehr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rodrigo Sergio Wiederkehr has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Maarten Fauvart
IMEC, Leuven, Belgium
8 shared publications - Maria Cecilia Salvadori
Instituto de Física, Universidade de São Paulo, São Paulo, SP, Brazil
8 shared publications - Mauro Cattani
Universidade de São Paulo
7 shared publications Tim Stakenborg
Department of Life Science Technologies, Imec, 3001, Leuven, Belgium
5 shared publications- Fernanda S. Teixeira
Instituto de Física Universidade de Sao Paulo São Paulo Brazil
4 shared publications - Mustafa M. Aslan
TÜBITAK Marmara Research Ctr. (Turkey)
4 shared publications
Latest Publications
- Open Access
- 26 February 2026
- Published by Elsevier in Talanta Open
- Vol. 13
A sensitive and compact on-site and real time quantitative detection of foodborne and clinical pathogens by on-chip qPCR
- 26 February 2026
- Published by Elsevier in Talanta Open
- Vol. 13
Open AccessA sensitive and compact on-site and real time quantitative detection of foodborne and clinical pathogens by on-chip qPCR
- 26 March 2025
- Published by Springer Nature in Biomedical Microdevices
- Vol. 27 (2) , 1-11
A capillary-driven microfluidic device for performing spatial multiplex PCR
Multiplex polymerase chain reaction (PCR) tests multiple biomarkers or pathogens that cause overlapping symptoms, making it an essential tool in syndromic testing. To achieve a multiplex PCR on chip, a design based on capillary-driven fluidic actuation is proposed. Our silicon chip features 22 reaction chambers and allows primers and probes to be pre-spotted in the reaction chambers prior to use. The design facilitates rapid sample loading through a common inlet channel, delivering reagents to all reaction chambers in less than 10 s. A custom clamping mechanism combined with a double depth cavity design ensures proper sealing during temperature cycling without the need for extra reagents like oil. Temperature cycling and fluorescence imaging were performed using custom-made hardware. As a proof of concept, two single nucleotide polymorphisms (SNPs), CyP2C19*2 and PCSK9 were detected. These results demonstrate the feasibility of on-chip multiplex PCR, compatible with different assays in parallel and requiring only a single pipetting step for reagent loading, without active fluidic actuation like pumping.
- 26 March 2025
- Published by Springer Nature in Biomedical Microdevices
- Vol. 27 (2) , 1-11
A capillary-driven microfluidic device for performing spatial multiplex PCR
Multiplex polymerase chain reaction (PCR) tests multiple biomarkers or pathogens that cause overlapping symptoms, making it an essential tool in syndromic testing. To achieve a multiplex PCR on chip, a design based on capillary-driven fluidic actuation is proposed. Our silicon chip features 22 reaction chambers and allows primers and probes to be pre-spotted in the reaction chambers prior to use. The design facilitates rapid sample loading through a common inlet channel, delivering reagents to all reaction chambers in less than 10 s. A custom clamping mechanism combined with a double depth cavity design ensures proper sealing during temperature cycling without the need for extra reagents like oil. Temperature cycling and fluorescence imaging were performed using custom-made hardware. As a proof of concept, two single nucleotide polymorphisms (SNPs), CyP2C19*2 and PCSK9 were detected. These results demonstrate the feasibility of on-chip multiplex PCR, compatible with different assays in parallel and requiring only a single pipetting step for reagent loading, without active fluidic actuation like pumping.
- 3 November 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (45) , 15781-15789
Amplification Efficiency and Template Accessibility as Distinct Causes of Rain in Digital PCR: Monte Carlo Modeling and Experimental Validation
Partitions in digital PCR (dPCR) assays do not reach the detection threshold at the same time. This heterogeneity in amplification results in intermediate endpoint fluorescence values (i.e., rain) and misclassification of partitions, which has a major impact on the accuracy of nucleic acid quantification. Rain most often results from a reduced amplification efficiency or template inaccessibility; however, exactly how these contribute to rain has not been described. We developed and experimentally validated an analytical model that mechanistically explains the relationship between amplification efficiency, template accessibility, and rain. Using Monte Carlo simulations, we show that a reduced amplification efficiency leads to broader threshold cycle (Ct) distributions that can be fitted using a log-normal probability distribution. From the fit parameters, the amplification efficiency can be calculated. Template inaccessibility, on the other hand, leads to a different rain pattern, in which a distinct exponential tail in the Ct distribution can be observed. Using our model, it is possible to determine if the amplification efficiency, template accessibility, or another source is the main contributor of rain in dPCR assays. We envision that this model will facilitate and speed up dPCR assay optimization and provide an indication for the accuracy of the assay.
- 3 November 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (45) , 15781-15789
Amplification Efficiency and Template Accessibility as Distinct Causes of Rain in Digital PCR: Monte Carlo Modeling and Experimental Validation
Partitions in digital PCR (dPCR) assays do not reach the detection threshold at the same time. This heterogeneity in amplification results in intermediate endpoint fluorescence values (i.e., rain) and misclassification of partitions, which has a major impact on the accuracy of nucleic acid quantification. Rain most often results from a reduced amplification efficiency or template inaccessibility; however, exactly how these contribute to rain has not been described. We developed and experimentally validated an analytical model that mechanistically explains the relationship between amplification efficiency, template accessibility, and rain. Using Monte Carlo simulations, we show that a reduced amplification efficiency leads to broader threshold cycle (Ct) distributions that can be fitted using a log-normal probability distribution. From the fit parameters, the amplification efficiency can be calculated. Template inaccessibility, on the other hand, leads to a different rain pattern, in which a distinct exponential tail in the Ct distribution can be observed. Using our model, it is possible to determine if the amplification efficiency, template accessibility, or another source is the main contributor of rain in dPCR assays. We envision that this model will facilitate and speed up dPCR assay optimization and provide an indication for the accuracy of the assay.
- Open Access
- 14 May 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Silicon µPCR Chip for Forensic STR Profiling with Hybeacon Probe Melting Curves
The demand to perform forensic DNA profiling outside of centralized laboratories and on the crime scene is increasing. Several criminal investigations would benefit tremendously from having DNA based information available in the first hours rather than days or weeks. However, due to the complexity and time-consuming nature of standard DNA fingerprinting methods, rapid and automated analyses are hard to achieve. We here demonstrate the implementation of an alternative DNA fingerprinting method in a single microchip. By combining PCR amplification and HyBeacon melting assays in a silicon Lab-on-a-chip (LoC), a significant step towards rapid on-site DNA fingerprinting is taken. The small form factor of a LoC reduces reagent consumption and increases portability. Additional miniaturization is achieved through an integrated heating element covering 24 parallel micro-reactors with a reaction volume of 0.14 µl each. The high level of parallelization allows the simultaneous analysis of 4 short tandem repeat (STR) loci and the amelogenin gender marker commonly included in forensic DNA analysis. A reference and crime scene sample can be analyzed simultaneously for direct comparison. Importantly, by using industry-standard semiconductor manufacturing processes, mass manufacturability can be guaranteed. Following assay design and optimization, complete 5-loci profiles could be robustly generated on-chip that are on par with those obtained using conventional benchtop real-time PCR thermal cyclers. Together, our results are an important step towards the development of commercial, mass-produced, portable devices for on-site testing in forensic DNA analysis.
- 14 May 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Open AccessSilicon µPCR Chip for Forensic STR Profiling with Hybeacon Probe Melting Curves
The demand to perform forensic DNA profiling outside of centralized laboratories and on the crime scene is increasing. Several criminal investigations would benefit tremendously from having DNA based information available in the first hours rather than days or weeks. However, due to the complexity and time-consuming nature of standard DNA fingerprinting methods, rapid and automated analyses are hard to achieve. We here demonstrate the implementation of an alternative DNA fingerprinting method in a single microchip. By combining PCR amplification and HyBeacon melting assays in a silicon Lab-on-a-chip (LoC), a significant step towards rapid on-site DNA fingerprinting is taken. The small form factor of a LoC reduces reagent consumption and increases portability. Additional miniaturization is achieved through an integrated heating element covering 24 parallel micro-reactors with a reaction volume of 0.14 µl each. The high level of parallelization allows the simultaneous analysis of 4 short tandem repeat (STR) loci and the amelogenin gender marker commonly included in forensic DNA analysis. A reference and crime scene sample can be analyzed simultaneously for direct comparison. Importantly, by using industry-standard semiconductor manufacturing processes, mass manufacturability can be guaranteed. Following assay design and optimization, complete 5-loci profiles could be robustly generated on-chip that are on par with those obtained using conventional benchtop real-time PCR thermal cyclers. Together, our results are an important step towards the development of commercial, mass-produced, portable devices for on-site testing in forensic DNA analysis.
- Open Access
- 14 January 2019
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 411 (6) , 1127-1134
Development and validation of a glass-silicon microdroplet-based system to measure sulfite concentrations in beverages
Abstract Sulfite is often added to beverages as an antioxidant and antimicrobial agent. In fermented beverages, sulfite is also naturally produced by yeast cells. However, sulfite causes adverse health effects in asthmatic patients and accurate measurement of the sulfite concentration is therefore very important. Current sulfite analysis methods are time- and reagent-consuming and often require costly equipment. Here, we present a system allowing sensitive, ultralow-volume sulfite measurements based on a reusable glass-silicon microdroplet platform on which microdroplet generation, addition of enzymes through chemical-induced emulsion destabilization and pillar-induced droplet merging, emulsion restabilization, droplet incubation, and fluorescence measurements are integrated. In a first step, we developed and verified a fluorescence-based enzymatic assay for sulfite by measuring its analytical performance (LOD, LOQ, the dynamic working range, and the influence of salts, colorant, and sugars) and comparing fluorescent microplate readouts of fermentation samples with standard colorimetric measurements using the 5,5′-dithiobis-(2-nitrobenzoic acid) assay of the standard Gallery Plus Beermaster analysis platform. Next, samples were analyzed on the microdroplet platform, which also showed good correlation with the standard colorimetric analysis. Although the presented platform does not allow stable reinjection of droplets due to the presence of a tight array of micropillars at the fluidics entrances to prevent channel clogging by dust, removing the pillars, and integrating miniaturized pumps and optics in a future design would allow to use this platform for high-throughput, automated, and portable screening of microbes, plant, or mammalian cells. ᅟ
- 14 January 2019
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 411 (6) , 1127-1134
Open AccessDevelopment and validation of a glass-silicon microdroplet-based system to measure sulfite concentrations in beverages
Abstract Sulfite is often added to beverages as an antioxidant and antimicrobial agent. In fermented beverages, sulfite is also naturally produced by yeast cells. However, sulfite causes adverse health effects in asthmatic patients and accurate measurement of the sulfite concentration is therefore very important. Current sulfite analysis methods are time- and reagent-consuming and often require costly equipment. Here, we present a system allowing sensitive, ultralow-volume sulfite measurements based on a reusable glass-silicon microdroplet platform on which microdroplet generation, addition of enzymes through chemical-induced emulsion destabilization and pillar-induced droplet merging, emulsion restabilization, droplet incubation, and fluorescence measurements are integrated. In a first step, we developed and verified a fluorescence-based enzymatic assay for sulfite by measuring its analytical performance (LOD, LOQ, the dynamic working range, and the influence of salts, colorant, and sugars) and comparing fluorescent microplate readouts of fermentation samples with standard colorimetric measurements using the 5,5′-dithiobis-(2-nitrobenzoic acid) assay of the standard Gallery Plus Beermaster analysis platform. Next, samples were analyzed on the microdroplet platform, which also showed good correlation with the standard colorimetric analysis. Although the presented platform does not allow stable reinjection of droplets due to the presence of a tight array of micropillars at the fluidics entrances to prevent channel clogging by dust, removing the pillars, and integrating miniaturized pumps and optics in a future design would allow to use this platform for high-throughput, automated, and portable screening of microbes, plant, or mammalian cells. ᅟ
Ultra-fast, sensitive and quantitative on-chip detection of group B streptococci in clinical samples
- Open Access
- 29 June 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-8
Multiplex STR amplification sensitivity in a silicon microchip
The demand for solutions to perform forensic DNA profiling outside of centralized laboratories is increasing. We here demonstrate highly sensitive STR amplification using a silicon micro-PCR (µPCR) chip. Exploiting industry-standard semiconductor manufacturing processes, a device was fabricated that features a small form factor thanks to an integrated heating element covering three parallel micro-reactors with a reaction volume of 0.5 µl each. Diluted reference DNA samples (1 ng–31 pg) were amplified on the µPCR chip using the forensically validated AmpFISTR Identifier Plus kit, followed by conventional capillary electrophoresis. Complete STR profiles were generated with input DNA quantities down to 62 pg. Occasional allelic dropouts were observed from 31 pg downward. On-chip STR profiles were compared with those of identical samples amplified using a conventional thermal cycler for direct comparison of amplification sensitivity in a forensic setting. The observed sensitivity was in line with kit specifications for both µPCR and conventional PCR. Finally, a rapid amplification protocol was developed. Complete STR profiles could be generated in less than 17 minutes from as little as 125 pg template DNA. Together, our results are an important step towards the development of commercial, mass-produced, relatively cheap, handheld devices for on-site testing in forensic DNA analysis.
- 29 June 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-8
Open AccessMultiplex STR amplification sensitivity in a silicon microchip
The demand for solutions to perform forensic DNA profiling outside of centralized laboratories is increasing. We here demonstrate highly sensitive STR amplification using a silicon micro-PCR (µPCR) chip. Exploiting industry-standard semiconductor manufacturing processes, a device was fabricated that features a small form factor thanks to an integrated heating element covering three parallel micro-reactors with a reaction volume of 0.5 µl each. Diluted reference DNA samples (1 ng–31 pg) were amplified on the µPCR chip using the forensically validated AmpFISTR Identifier Plus kit, followed by conventional capillary electrophoresis. Complete STR profiles were generated with input DNA quantities down to 62 pg. Occasional allelic dropouts were observed from 31 pg downward. On-chip STR profiles were compared with those of identical samples amplified using a conventional thermal cycler for direct comparison of amplification sensitivity in a forensic setting. The observed sensitivity was in line with kit specifications for both µPCR and conventional PCR. Finally, a rapid amplification protocol was developed. Complete STR profiles could be generated in less than 17 minutes from as little as 125 pg template DNA. Together, our results are an important step towards the development of commercial, mass-produced, relatively cheap, handheld devices for on-site testing in forensic DNA analysis.
- 9 May 2018
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 28 (8) , 085014
A comprehensive methodology for design and development of an integrated microheater for on-chip DNA amplification
This paper presents the design and development of an optimized aluminum microheater integrated onto a biochip for the amplification of DNA using polymerase chain reaction (PCR). A coupled 3D finite element electro-thermal simulation has been used to aid in the design of the microheater and the PCR reactor. The microheater has a special shape, designed to provide a uniform temperature throughout the PCR chamber. The microreactor is fabricated at the center of a 20 mm × 20 mm silicon chip. It has a meandered shape, a volume of 1.89 µ l and occupies a square area with a side of 3.8 mm. Microchannels to transport fluid in and out of the reactor are also provided. After heater design optimization, the simulated temperature of the fluid volume within the PCR chamber is very uniform (95% of the volume has a temperature within ±0.2 °C when the average temperature is 60 °C). This result is validated by DNA melting point experiments, showing a very similar uniformity. A PCR experiment, consisting of 50 cycles of amplification is conducted to demonstrate functionality of the system; amplifications is uniform across the reactor with variation of the threshold cycle within about 0.5 units.
- 9 May 2018
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 28 (8) , 085014
A comprehensive methodology for design and development of an integrated microheater for on-chip DNA amplification
This paper presents the design and development of an optimized aluminum microheater integrated onto a biochip for the amplification of DNA using polymerase chain reaction (PCR). A coupled 3D finite element electro-thermal simulation has been used to aid in the design of the microheater and the PCR reactor. The microheater has a special shape, designed to provide a uniform temperature throughout the PCR chamber. The microreactor is fabricated at the center of a 20 mm × 20 mm silicon chip. It has a meandered shape, a volume of 1.89 µ l and occupies a square area with a side of 3.8 mm. Microchannels to transport fluid in and out of the reactor are also provided. After heater design optimization, the simulated temperature of the fluid volume within the PCR chamber is very uniform (95% of the volume has a temperature within ±0.2 °C when the average temperature is 60 °C). This result is validated by DNA melting point experiments, showing a very similar uniformity. A PCR experiment, consisting of 50 cycles of amplification is conducted to demonstrate functionality of the system; amplifications is uniform across the reactor with variation of the threshold cycle within about 0.5 units.
- 1 May 2018
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (11) , 2596-2603
Rapid and sensitive detection of viral nucleic acids using silicon microchips
Rapid and sensitive amplification of viral nucleic acids is feasible on a flexible silicon microchip technology platform.
- 1 May 2018
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (11) , 2596-2603
Rapid and sensitive detection of viral nucleic acids using silicon microchips
Rapid and sensitive amplification of viral nucleic acids is feasible on a flexible silicon microchip technology platform.
- 9 September 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 16 (20) , 4012-4019
Multiplex SNP genotyping in whole blood using an integrated microfluidic lab-on-a-chip
Pharmacogenetics has often been touted as a cornerstone for precision medicine as detailed knowledge of a specific genetic makeup may allow for accurate predictions of a patient's individual drug response. Still, the widespread use of genetic tests is limited as they remain expensive and cumbersome, requiring sophisticated tools and highly trained personnel. In order for pharmacogenetics to reach its full potential, more cost-effective and easily accessible genotyping methods are desired. To meet these challenges, we present a silicon-based integrated microsystem for the detection of multiple single nucleotide polymorphisms (SNPs) directly from human blood. The device combines a blood lysis chamber, a cross-flow filter, a T-junction mixer, and a microreactor for quantitative polymerase chain reaction (qPCR). Using this device, successful on-chip genotyping of two clinically relevant SNPs in human CYP2C9 gene was demonstrated with TaqMan assays, starting from blood. The two SNPs were detected simultaneously by introducing a sequence of plugs, each containing a different set of primers and probes. The method can be easily extended to detect several SNPs. The microsystem described here offers a rapid, reproducible, and accurate sample-to-answer technology enabling multiplex SNP profiling in point-of-care settings, bringing pharmacogenetics-based precision medicine a step closer to reality.
- 9 September 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 16 (20) , 4012-4019
Multiplex SNP genotyping in whole blood using an integrated microfluidic lab-on-a-chip
Pharmacogenetics has often been touted as a cornerstone for precision medicine as detailed knowledge of a specific genetic makeup may allow for accurate predictions of a patient's individual drug response. Still, the widespread use of genetic tests is limited as they remain expensive and cumbersome, requiring sophisticated tools and highly trained personnel. In order for pharmacogenetics to reach its full potential, more cost-effective and easily accessible genotyping methods are desired. To meet these challenges, we present a silicon-based integrated microsystem for the detection of multiple single nucleotide polymorphisms (SNPs) directly from human blood. The device combines a blood lysis chamber, a cross-flow filter, a T-junction mixer, and a microreactor for quantitative polymerase chain reaction (qPCR). Using this device, successful on-chip genotyping of two clinically relevant SNPs in human CYP2C9 gene was demonstrated with TaqMan assays, starting from blood. The two SNPs were detected simultaneously by introducing a sequence of plugs, each containing a different set of primers and probes. The method can be easily extended to detect several SNPs. The microsystem described here offers a rapid, reproducible, and accurate sample-to-answer technology enabling multiplex SNP profiling in point-of-care settings, bringing pharmacogenetics-based precision medicine a step closer to reality.