    Diagnosis of Inter-Turn Shorts of Loaded Transformer Under Various Load Currents and Power Factors; Impulse Voltage-Based Frequency Response Approach

    by Natarajan Shanmugam, Srinivasan Gopal, Balasubramanian Madanmohan, S. P. Balaji, Rajesh Rajamani

    Inter-turn short circuits within the transformer winding are diagnosable through the impulse voltage based frequency response analysis (IFRA). If the diagnosis is made Online, interruption to the power network can be avoided. However, the transformer’s load may influence the frequency response based diagnostic process, and this aspect has not yet been investigated. Motivated by this research gap, experimental investigations were carried out on a three-phase 5 kVA, 440 V/440 V Star/Delta transformer and a three-phase 315 kVA, 11 kV/433 V, Dyn11 distribution transformer, when they were supplying power to loads of different magnitudes and power factors. The influence of the load current and its power factor on the IFRA was observed under the transformer’s healthy condition and with inter-turn short circuits in one of the windings. Investigations under these different loaded conditions revealed that a signature FRA plot developed at a particular load condition cannot be directly used for assessing the condition of the transformer at a different load. Both the magnitude and the power factor of the load are found to influence the frequency response. A careful interpretation of the Frequency response of the transformer, based on its load, was found effective in detecting and locating the inter-turn shorts.


  • Open Access

    Extended Application for the Impulse-Based Frequency Response Analysis: Preliminary Diagnosis of Partial Discharges in Transformer

    by Kamalaselvan Arunachalam, Balasubramanian Madanmohan, Rajesh Rajamani

    Frequency response analysis (FRA) with low impulse voltage signals (IFRA) is useful in diagnosing faults like the mechanical displacements and inter-turn shorts in transformers. However, they fail to diagnose the presence of any source of partial discharges (PD) across the oil-paper insulation. PD is happening only above its inception voltage level for the applied signal, thereby changing the loading effect of the insulation system and becoming detectable. If FRA tests are extended carefully up to high voltages, they can be even useful for the preliminary diagnosis of the potential sources of PD. Investigations were not carried out so far to get an insight into this aspect. Motivated by this, an investigation was done, first time, on a 315 kVA, 11 kV/433 V transformer. IFRA was carried out carefully at various voltage levels, up to 50% of the Basic impulse insulation level. The IFRA results of the transformer under its healthier condition, under the emulated inter-turn shorts and, the PD sources across the major-insulation were, observed and compared. Low-voltage IFRA is found sufficient, only for diagnosing the inter-turn shorts. When IFRA is extended to moderately high voltage, it is found useful in the preliminary diagnosis of the PD sources.


  • Open Access

    Extended Use for the Frequency Response Analysis: Switching Impulse Voltage Based Preliminary Diagnosis of Potential Sources of Partial Discharges in Transformer

    by Kamalaselvan Arunachalam, Balasubramanian Madanmohan, Rajesh Rajamani, Natarajan Prabaharan, Hassan Haes Alhelou, Pierluigi Siano

    The Frequency Response Analysis approach (FRA) is useful in the fault diagnosis of transformers. However, its usefulness in diagnosing any potential sources of Partial Discharge (PD) in transformers has not been thoroughly investigated so far. In this work, the use of Impulse voltage-based FRA (IFRA) in diagnosing inter-turn shorts and potential sources of PD were investigated on a 315 kVA, 11 kV/433 V transformer. Inter-turn shorts and PD sources were emulated and the usefulness of IFRA in their diagnosis was investigated while using switching impulse voltage at different magnitude levels as the test signals. For emulating the inter-turn shorts and the PDs, special tappings were provided on one of the 11 kV windings through the low capacitance bushings. Low voltage impulse was successful in diagnosing the inter-turn shorts, but unsuccessful in identifying the sources of PDs. During the test condition, the test voltage was adjusted with the presence of artificially created PD sources. The frequency response of the transformer before and after the inception of PD was observed and analyzed in this article. The FRA results demonstrated that the switching impulse voltage based IFRA approach at moderate voltages could be useful in diagnosing the presence of the potential sources of PDs.


  • Open Access

    Influence of the Load on the Impulse Frequency Response Approach Based Diagnosis of Transformer’s Inter-Turn Short-Circuit

    by Natarajan Shanmugam, Balasubramanian Madanmohan, Rajesh Rajamani

    Frequency Response Analysis (FRA) is an Off-line condition monitoring technique for the transformers and is successful, in diagnosing mechanical faults and inter-turn short-circuits. Only limited literature is available for On-line FRA works, and the effect of the transformer’s load on the fault diagnosing capability of FRA has not yet been analysed. Motivated by this research gap, an experimental investigation was done to analyze the effect of load on IFRA based inter-turn short-circuit diagnosis. A single-phase 1 kVA, 240V/240 V transformer supplying R and R-L loads and a three-phase 5 kVA, 440 V/440 V transformer supplying an induction motor at various load levels were tested. Inter-turn short-circuits were emulated in their windings and, the effectiveness of IFRA in diagnosing the same was investigated. Comparisons were made between the frequency response of the loaded transformers in their healthier conditions and emulated fault conditions, based on the transfer function plots and the statistical parameters. Investigations reveal that the loads alter the useful spectrum of IFRA. The frequency response of the healthier transformer itself varies based on the transformer’s load and necessitates a careful focus on the sensitive frequency spectra for effective inter-turn short-circuit diagnosis in loaded transformers.


  • Open Access

    Interturn short diagnosis in small transformers through impulse injection: on‐line on‐load self‐impedance transfer function approach

    by Rajesh Rajamani, Muthaiah Rajappa, Kamalaselvan Arunachalam, Balasubramanian Madanmohan

    Electrical shorts in transformers on load can be diagnosed by frequency response analysis (FRA) using impulse or sinusoidal sweep signal. At HV laboratory of SASTRA, a low‐voltage impulse based on‐line on‐load FRA (OLOL FRA) was carried out on a single phase 50 Hz, 1 kVA, 240 V/240 V small laboratory transformer while delivering power to lamp load, and the effectiveness in electrical short diagnosis was analysed. For this purpose, some artificial faults were created within one of the windings of the transformer investigated, and the responses of the winding to different frequency components of the impulse voltages were observed before and after introducing these faults. Comparison of the frequency response (impedance) of the winding under normal condition with frequency response under fault condition was made, which clearly indicated that faults had altered the winding impedance for some frequency components of the impulse. This reveals that fault within the winding can be identified and located, by the OLOL FRA technique, through careful comparisons of frequency response. Statistical analysis of transfer function magnitudes with correlation coefficient, standard deviation and absolute sum of logarithmic error has also validated the same.


  • Open Access

    Sweep frequency response analysis based diagnosis of shorts within transformer windings

    by Rajesh Rajamani, Muthaiah Rajappa, Balasubramanian Madanmohan

    Sweep frequency response analysis (SFRA) is a diagnostic technique which can identify faults within transformers. Though SFRA approaches are used to identify faults, their effectiveness in discriminating two same level faults at two different locations within transformer is not much analysed and reported. Experiments were carried out on a 1 kVA, single phase, 240 V/240 V laboratory transformers and on a 315 kVA, three phase, 11 kV/433 V, Dyn11, ONAN, distribution transformer, to analyse the usefulness of SFRA in inter turn short identification and discriminations. Faulty conditions were created artificially in transformers, by shorting the tappings provided in one of their windings, at different levels and locations. Open circuit self‐impedance and transfer voltage transfer function approaches were experimented and transfer function plots representing winding impedance and voltage transfer ratios at various frequencies were developed for transformers, under normal and faulty conditions. Significant differences were identified at some frequencies while comparing normal case plots with faulty case plots. It was observed that the SFRA is effective in identifying shorts within transformer winding as well as, discriminating two same level shorts (i.e.) locating shorts. Statistical analysis using absolute difference and min–max ratio also confirmed the efficacy of these approaches.


  • Development of a portable PDC diagnostic system for discriminating transformer insulation and winding faults using Homoscedastic Probabilistic Neural Network

    by S. Natarajan, R. Rajesh, S. Venkatesh, S. Mohamed Ghouse

    Assessment of the healthiness of insulation in transformers is a vital aspect for power system utilities since most in-service transformers which form the crux of the power system have reached its lifetime duration. Among many factors, moisture and ageing significantly influence the dielectric properties of a transformer. Recently, several researchers have proposed new diagnostic methods that are complementary to the classical measurement systems such as insulation resistance, power frequency dissipation factor, polarization index measurements etc. Dielectric diagnosis with polarization and depolarization currents (PDC) uses the dielectric system response in time domain. In this research a laboratory-built, compact and easy to construct PDC measurement system is implemented without compromising on the reliability of the measurement system. The capability of the measuring system is ascertained by carrying out detailed studies on scaled down laboratory models and a 315 kVA, 11kV/433V, Dyn 11, ONAN distribution transformer with artificially simulated insulation flaws namely moisture content in oil, inter-disc/ inter-turn shorts, winding asymmetry etc. Simulation studies on the transformer R-C equivalent representation are also carried out to validate the response of the PDC system. In addition, the Homoscedastic Probabilistic Neural Network (HOPNN) which utilized the Expectation Maximization (EM) with the Maximum Likelihood (ML) algorithm is implemented for obtaining a parsimonious training for subsequent identification of faults.

  • Experimental Investigations on IEC Suggested Methods for Improving Waveshape During Impulse Voltage Testing

    by B. Karthikeyan, R. Rajesh, M. Balasubramanian, S. Saravanan

    The objective of lightning impulse voltage (LI Voltage) test on power transformer is to check the dielectric strength of the transformer against over voltages of atmospheric origin. Mostly when transformers of high transformation ratio is subjected to LI voltage test, the standard LI voltage waveshape distorts and consequently the wavetail falls much below the specified tolerance and swings to opposite polarity. In these cases, IEC has suggested some waveshape improvement techniques in the test circuit or energy enhancement of the impulse generator. This paper elucidates the experimental investigations carried out on a 315 kVA, 11 kV/433 V, Dyn 11, three phase transformer. Investigations was carried out based on the voltage and stress analysis on the transformer windings. For this analysis, tapping are provided on one of the HV winding at 100%, 87.5%, 62.5%, 37.5%, and 12.5%. The investigations include voltage and stress distribution on the windings, voltage across the waveshape component and analysis of stress across major and minor insulation. Apart from voltage and stress distribution analysis, a few novel techniques of waveshape improvement are attempted and a comparative analysis with IEC methods is also presented in this paper


  • Dielectric Integrity Test- A Tuned Circuit Approach

    by S. Saravanan, R. Rajesh, B. Karthikeyan, S Venkatesh

    Dielectric integrity tests usually performed to check the dielectric strength of an electrical insulation are power frequency withstand, lightning impulse (LI) and switching impulse (SI) withstand voltage tests. These standard testing techniques involve subjecting the insulation to over voltages which are several times the rated voltage. Incidentally, breakdown of insulation occurs mainly due to stresses in the insulation due to free volume charges and thermal agitation. It is observed that the stress and heat produced in the insulation of an alternating voltage of comparatively lesser magnitude at high frequencies can be achieved across the insulation i.e., at certain levels the volume charges and thermal agitation due to dipole spinning increases, leading to lower breakdown values. This concept may be effectively utilized as a supplementary testing technique where the need for testing the dielectric integrity of apparatus in laboratory with limitations on test voltages arises. A tuned high frequency high voltage (HVHF) generating setup has been proposed for conducting an exhaustive experimental study and analysis on the frequency response of air and transformer oil test set up with different electrode configurations. Impulse voltage tests for breakdown have also been carried out for the purpose of comparison of the proposed scheme