Ruiming Luo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ruiming Luo has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Zhichuan Tang
Industrial Design Institute, Zhejiang University of Technology, Hangzhou, China
2 shared publications - Chao Li
College of Computer Science and Technology, Zhejiang University, Hangzhou 310027, China
1 shared publication - Ning Zhang
Key Laboratory of Advanced Manufacturing Technology of the Ministry of Education, Guizhou University, Guiyang, China
1 shared publication Shouqian Sun
College of Computer Science and Technology, Zhejiang University, Hangzhou 310027, China
1 shared publication- Si-Yuan Huang
College of Mechanical Engineering, Guizhou University, Guiyang, China
1 shared publication Weide Wang
College of Computer Science and Technology, Zhejiang University, Hangzhou 310027, China
1 shared publication
Latest Publications
- Open Access
- 17 March 2022
- Published by Springer Nature in SN Applied Sciences
- Vol. 4 (4) , 1-18
Mid-air gestures for in-vehicle media player: elicitation, segmentation, recognition, and eye-tracking testing
There was a problem of great distraction in traditional touch interactive operation of in-vehicle information interface, but the application of gesture recognition technology on in-vehicle system improved this problem. However, users had less experience in this new interactive mode, and the cognitive deviation of the agreement between gestures and commands could directly affect the safety of drivers. The main purpose of this paper was to obtain the user's preference mid-air gestures for the in-vehicle information interface by using the user-elicitation method. In addition, the optimized gesture recognition network structure was applied to the prototype system of in-vehicle information interaction with user-defined mid-air gestures developed by us, and the effectiveness of the system was evaluated by collecting eye movement indicators of users through the simulation of driving eye movement experiments. In the process of user elicitation, the principle of command prompt and agreement rate was introduced. According to the agreement rate elicited by users (AR = .397), we got the gesture consensus set design direction of in-vehicle information control. The experimental results of the eye movement index showed that the method of user-defined mid-air gestures can effectively improve driving safety on in-vehicle media control, and reduced the distraction of users when driving compared with the traditional touch-based method. Article highlights: The user's preferred in-vehicle media control task gestures were obtained through the user elicitation method. Constructed an in-vehicle secondary task control prototype system based on gesture recognition. The eye movement experiment proved that the prototype system can reduce the user's distraction when operating the in-vehicle's secondary tasks.
- 17 March 2022
- Published by Springer Nature in SN Applied Sciences
- Vol. 4 (4) , 1-18
Open AccessMid-air gestures for in-vehicle media player: elicitation, segmentation, recognition, and eye-tracking testing
There was a problem of great distraction in traditional touch interactive operation of in-vehicle information interface, but the application of gesture recognition technology on in-vehicle system improved this problem. However, users had less experience in this new interactive mode, and the cognitive deviation of the agreement between gestures and commands could directly affect the safety of drivers. The main purpose of this paper was to obtain the user's preference mid-air gestures for the in-vehicle information interface by using the user-elicitation method. In addition, the optimized gesture recognition network structure was applied to the prototype system of in-vehicle information interaction with user-defined mid-air gestures developed by us, and the effectiveness of the system was evaluated by collecting eye movement indicators of users through the simulation of driving eye movement experiments. In the process of user elicitation, the principle of command prompt and agreement rate was introduced. According to the agreement rate elicited by users (AR = .397), we got the gesture consensus set design direction of in-vehicle information control. The experimental results of the eye movement index showed that the method of user-defined mid-air gestures can effectively improve driving safety on in-vehicle media control, and reduced the distraction of users when driving compared with the traditional touch-based method. Article highlights: The user's preferred in-vehicle media control task gestures were obtained through the user elicitation method. Constructed an in-vehicle secondary task control prototype system based on gesture recognition. The eye movement experiment proved that the prototype system can reduce the user's distraction when operating the in-vehicle's secondary tasks.
- Open Access
The Impact of Load Style Variation on Gait Recognition Based on sEMG Images Using a Convolutional Neural Network
Surface electromyogram (sEMG) signals are widely employed as a neural control source for lower-limb exoskeletons, in which gait recognition based on sEMG is particularly important. Many scholars have taken measures to improve the accuracy of gait recognition, but several real-time limitations affect its applicability, of which variation in the load styles is obvious. The purposes of this study are to (1) investigate the impact of different load styles on gait recognition; (2) study whether good gait recognition performance can be obtained when a convolutional neural network (CNN) is used to deal with the sEMG image from sparse multichannel sEMG (SMC-sEMG); and (3) explore whether the control system of the lower-limb exoskeleton trained by sEMG from part of the load styles still works efficiently in a real-time environment where multiload styles are required. In addition, we discuss an effective method to improve gait recognition at the levels of the load styles. In our experiment, fifteen able-bodied male graduate students with load (20% of body weight) and using three load styles (SBP = backpack, SCS = cross shoulder, SSS = straight shoulder) were asked to walk uniformly on a treadmill. Each subject performed 50 continuous gait cycles under three speeds (V3 = 3 km/h, V5 = 5 km/h, and V7 = 7 km/h). A CNN was employed to deal with sEMG images from sEMG signals for gait recognition, and back propagation neural networks (BPNNs) and support vector machines (SVMs) were used for comparison by dealing with the same sEMG signal. The results indicated that (1) different load styles had remarkable impact on the gait recognition at three speeds under three load styles (p < 0.001); (2) the performance of gait recognition from the CNN was better than that from the SVM and BPNN at each speed (84.83%, 81.63%, and 83.76% at V3; 93.40%, 88.48%, and 92.36% at V5; and 90.1%, 86.32%, and 85.42% at V7, respectively); and (3) when all the data from three load styles were pooled as testing sets at each speed, more load styles were included in the training set, better performance was obtained, and the statistical analysis suggested that the kinds of load styles included in training set had a significant effect on gait recognition (p = 0.002), from which it can be concluded that the control system of a lower-limb exoskeleton trained by sEMG using only some load styles is not sufficient in a real-time environment.
Open AccessThe Impact of Load Style Variation on Gait Recognition Based on sEMG Images Using a Convolutional Neural Network
Surface electromyogram (sEMG) signals are widely employed as a neural control source for lower-limb exoskeletons, in which gait recognition based on sEMG is particularly important. Many scholars have taken measures to improve the accuracy of gait recognition, but several real-time limitations affect its applicability, of which variation in the load styles is obvious. The purposes of this study are to (1) investigate the impact of different load styles on gait recognition; (2) study whether good gait recognition performance can be obtained when a convolutional neural network (CNN) is used to deal with the sEMG image from sparse multichannel sEMG (SMC-sEMG); and (3) explore whether the control system of the lower-limb exoskeleton trained by sEMG from part of the load styles still works efficiently in a real-time environment where multiload styles are required. In addition, we discuss an effective method to improve gait recognition at the levels of the load styles. In our experiment, fifteen able-bodied male graduate students with load (20% of body weight) and using three load styles (SBP = backpack, SCS = cross shoulder, SSS = straight shoulder) were asked to walk uniformly on a treadmill. Each subject performed 50 continuous gait cycles under three speeds (V3 = 3 km/h, V5 = 5 km/h, and V7 = 7 km/h). A CNN was employed to deal with sEMG images from sEMG signals for gait recognition, and back propagation neural networks (BPNNs) and support vector machines (SVMs) were used for comparison by dealing with the same sEMG signal. The results indicated that (1) different load styles had remarkable impact on the gait recognition at three speeds under three load styles (p < 0.001); (2) the performance of gait recognition from the CNN was better than that from the SVM and BPNN at each speed (84.83%, 81.63%, and 83.76% at V3; 93.40%, 88.48%, and 92.36% at V5; and 90.1%, 86.32%, and 85.42% at V7, respectively); and (3) when all the data from three load styles were pooled as testing sets at each speed, more load styles were included in the training set, better performance was obtained, and the statistical analysis suggested that the kinds of load styles included in training set had a significant effect on gait recognition (p = 0.002), from which it can be concluded that the control system of a lower-limb exoskeleton trained by sEMG using only some load styles is not sufficient in a real-time environment.
- 29 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 28 (1) , 267-276
A Low-Cost End-to-End sEMG-Based Gait Sub-Phase Recognition System
As surface electromyogram (sEMG) signals have the ability to detect human movement intention, they are commonly used to be control inputs. However, gait sub-phase classification typically requires monotonous manual labeling process, and commercial sEMG acquisition devices are quite bulky and expensive, thus current sEMG-based gait sub-phase recognition systems are complex and have poor portability. This study presents a low-cost but effective end-to-end sEMG-based gait sub-phase recognition system, which contains a wireless multi-channel signal acquisition device simultaneously collecting sEMG of thigh muscles and plantar pressure signals, and a novel neural network-based sEMG signal classifier combining long-short term memory (LSTM) with multilayer perceptron (MLP). We evaluated the system with subjects walking under five conditions: flat terrain at 5 km/h, flat terrain at 3 km/h, 20 kg backpack at 5 km/h, 20 kg shoulder bag at 5 km/h and 15∘ slope at 5 km/h. Experimental results show that the proposed method achieved average classification accuracies of 94.10%, 87.25%, 90.71%, 94.02%, and 87.87%, respectively, which were significantly higher than existing recognition methods. Additionally, the proposed system had a good real-time performance with low average inference time in the range of 3.25 3.31 ms.
- 29 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 28 (1) , 267-276
A Low-Cost End-to-End sEMG-Based Gait Sub-Phase Recognition System
As surface electromyogram (sEMG) signals have the ability to detect human movement intention, they are commonly used to be control inputs. However, gait sub-phase classification typically requires monotonous manual labeling process, and commercial sEMG acquisition devices are quite bulky and expensive, thus current sEMG-based gait sub-phase recognition systems are complex and have poor portability. This study presents a low-cost but effective end-to-end sEMG-based gait sub-phase recognition system, which contains a wireless multi-channel signal acquisition device simultaneously collecting sEMG of thigh muscles and plantar pressure signals, and a novel neural network-based sEMG signal classifier combining long-short term memory (LSTM) with multilayer perceptron (MLP). We evaluated the system with subjects walking under five conditions: flat terrain at 5 km/h, flat terrain at 3 km/h, 20 kg backpack at 5 km/h, 20 kg shoulder bag at 5 km/h and 15∘ slope at 5 km/h. Experimental results show that the proposed method achieved average classification accuracies of 94.10%, 87.25%, 90.71%, 94.02%, and 87.87%, respectively, which were significantly higher than existing recognition methods. Additionally, the proposed system had a good real-time performance with low average inference time in the range of 3.25 3.31 ms.