TSTravis Smith

Travis Smith

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Travis Smith has a total of 83 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • OPEN-CODE, REAL-TIME EMULATION TESTBED OF GRID-CONNECTED TYPE-3 WIND TURBINE SYSTEM WITH HARDWARE VALIDATION

    by Maximiliano Ferrari, Michael Orendorff, Travis Smith, Mark A. Buckner

    This paper presents the design and development of an open-code Type-3 wind turbine virtual-testbed for real-time simulations. The proposed testbed includes the bare code for all the models required to emulate a Type-3 wind turbine system: the Doubly-Fed Induction Generator (DFIG) dynamic model, single-mass drive train, wind turbine system, and average model of the back to back power. This testbed can be executed in PC-layer for offline simulations or can be executed in real-time on the National Instruments (NI)-CompactRIO (cRIO) platform. The discrete-time models are implemented on the Field Programmable Gate Array (FPGA), using LabVIEW, and validated against a physical hardware setup. The emulated stator and rotor currents and DC-link voltage are compared against physical measurements creating a validated platform independent from third-party models and suitable for applications in real-time. The proposed testbed is intended to be available to researchers, wind turbine manufacturers, and utility companies to perform tests using a validated platform to verify proposed control designs of DFIG wind turbines.


  • GMLC Southeast Regional Consortium: Technology Driven Improvements to Power Grid Resiliency

    by Alexander Melin, Travis Smith, Philip Irminger, Isabelle Snyder, Peter Fuhr, Ben Ollis, Marissa Morales Rodriguez, Bailu Xiao, Dan King, Jr. Drew Herron, et al.

    Recognizing that electric grid challenges can differ by geographical regions across the US, the Department of Energy (DOE) created a pioneer regional partnership to provide technical assistance to stakeholders facing grid modernization challenges. The southeast regional teams will transfer technologies developed under DOE auspices to stakeholders for testing, evaluation, and market validation. Regional members will help define critical challenges and pave the way for transition of technologies to the commercial sector. Using the depth and expertise at Oak Ridge National Laboratory, Savannah River National Laboratory, University of Tennessee’s CURENT, CAPER and the Clemson 20 MVA Electrical Grid Laboratory—along with critical industry partners, such as Duke Energy, TVA, Southern Company, EPB, and Santee Cooper—the Southeast Regional Consortium team will conduct collaborative research to advance the state of the grid in the Southeast region and improve power system resiliency to enhance responsiveness, enable faster restoration of power, and increase distributed energy resource (DER) concentrations. This report provides details of the technical research and demonstration projects accomplished by Oak Ridge National Laboratory (ORNL) as part of the Southeast Regional Consortium. Specifically, ORNL analyzed the application of optical current and voltage measurements impedance relays which would enable step distance protection to be deployed onmore » distribution systems. This would improve the precision of determining the geographic location of faults, increase network topology flexibility, and allow bi-directional power flow. Next, ORNL deployed time sensitive networking technology on the EPB fiberoptic data network to study the impact of increased sensor traffic on existing supervisory control and data acquisition data. The deterministic latency and high bandwidth were demonstrated by remotely inspecting a substation using a drone with full HD streaming video operated at the EPB Control Center. Finally, a new application-based communication and control system developed at ORNL call CSEISMIC was tested for future deployment on the EPB Control Center microgrid using a hardware-in-the-loop testbed that was also developed at ORNL. The controller was able to successfully optimize ancillary service when the microgrid is connected to the distribution network. The seamless islanding, resynchronization, and reconnection of the microgrid was also demonstrated through the testing. « less

  • Frequency measurement methods and impact in presence of frequency responsive loads and distributed energy resources

    by Isabelle Snyder, Travis Smith

    Frequency monitoring on the power system is used to balance load and generation, as load increases the frequency value decrease and as generation increases the frequency values increases. Under normal operation the frequency is maintained between 59.98Hz and 60.02Hz in a 60Hz system. Today the balance between load and generation is achieved by controlling generation only [1]. However, as more load control is being introduced to the power system, using the frequency value to turn on and off frequency responsive loads present a mechanism to provide regulation as well [2]. This method relies on local frequency measurement and local trigger set point. This paper illustrates the impact of frequency measurement on frequency responsive load application and on protection devices in presence of distributed generation.


  • Air conditioning stall phenomenon - Testing, model development, and simulation

    by Philip Irminger, D. Tom Rizy, Huijuan Li, Travis Smith, Keith Rice, Fangxing Li, Sarina Adhikari

    Electric distribution systems are experiencing power quality issues of extended reduced voltage due to fault-induced delayed voltage recovery (FIDVR). FIDVR occurs in part because modern air conditioner (A/C) and heat pump compressor motors are much more susceptible to stalling during a voltage sag or dip such as a sub-transmission fault. They are more susceptible than older A/C compressor motors due to the low inertia of these newer and more energy efficient motors. There is a concern that these local reduced voltage events on the distribution system will become more frequent and prevalent and will combine over larger areas and challenge transmission system voltage and ultimately power grid reliability. The Distributed Energy Communications and Controls (DECC) Laboratory at Oak Ridge National Laboratory (ORNL) has been employed to (1) test, (2) characterize and (3) model the A/C stall phenomenon.


  • Wind power plant SCADA and controls

    by B. Badrzadeh, M. Bradt, N. Castillo, R. Janakiraman, R. Kennedy, S. Klein, T. Smith, L. Vargas

    This paper discusses the range of application for SCADA and control systems in a wind power plant, the most important SCADA and control system considerations, and contractual requirements for SCADA and control systems.


  • Short circuit analysis of induction machines - wind power application

    by Dustin F. Howard, Travis M. Smith, Michael Starke, Ronald G. Harley

    The short circuit behavior of Type I (fixed speed) wind turbine-generators is analyzed in this paper to aid in the protection coordination of wind plants of this type. A simple network consisting of one wind turbine-generator is analyzed for two network faults: a three phase short circuit and a phase A to ground fault. Electromagnetic transient simulations and sequence network calculations are compared for the two fault scenarios. It is found that traditional sequence network calculations give accurate results for the short circuit currents in the balanced fault case, but are inaccurate for the un-faulted phases in the unbalanced fault case. The time-current behavior of the fundamental frequency component of the short circuit currents for both fault cases are described, and found to differ significantly in the unbalanced and balanced fault cases.


  • Harmonics and resonance issues in wind power plants

    by M. Bradt, B. Badrzadeh, E. Camm, D. Mueller, J. Schoene, T. Siebert, T. Smith, M. Starke, R. Walling

    This paper presents a summary of the most important issues with respect to harmonics and resonances within wind power plants. An introduction is given to provide an overview of the various power quality related issues encountered when designing, commissioning, or operating a wind power plant, as well as typical characteristics of the components associated with wind power plants. The many variables, which influence harmonics and resonance in wind power plants, will be described with respect to analysis methods, avoidance, mitigation, and compliance with IEEE Std 519-1992 recommended practices.


  • Harmonics and resonance issues in wind power plants

    by M. Bradt, B. Badrzadeh, E. Camm, D. Mueller, J. Schoene, T. Siebert, T. Smith, M. Starke, R. Walling

    This paper presents a summary of the most important issues with respect to harmonics and resonances within wind power plants. An introduction is given to provide an overview of the various power quality related issues encountered when designing, commissioning, or operating a wind power plant, as well as typical characteristics of the components associated with wind power plants. The many variables, which influence harmonics and resonance in wind power plants, will be described with respect to analysis methods, avoidance, mitigation, and compliance with IEEE Std 519-1992 recommended practices.


  • Wind power plant SCADA and controls

    by B. Badrzadeh, M. Bradt, N. Castillo, R. Janakiraman, R. Kennedy, S. Klein, T. Smith, L. Vargas

    This paper discusses the range of application for SCADA and control systems in a wind power plant, the most important SCADA and control system considerations, and contractual requirements for SCADA and control systems.