EGEwa Guzniczak

Ewa Guzniczak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ewa Guzniczak has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Oliver Otto

    Zentrum für Innovationskompetenz: Humorale Immunreaktionen bei kardiovaskulären Erkrankungen, Universität Greifswald, Fleischmannstr. 42, Greifswald, 17489, Germany

    5 shared publications
  • Helen Bridle

    School of Engineering and Physical Science, Department of Biological Chemistry, Biophysics and Bioengineering Edinburgh Campus, Heriot-Watt University, Edinburgh, EH14 4AS, Scotland, UK.

    4 shared publications
  • Melanie Jimenez

    Biomedical Engineering Division, James Watt School of Engineering, University of Glasgow, G12 8LT, UK

    4 shared publications
  • Nik Willoughby

    Heriot-Watt Univ. (United Kingdom)

    4 shared publications
  • Graeme Whyte

    Cavendish Laboratory, Department of Physics, University of Cambridge, J.J. Thomson Ave, Cambridge CB3 0HE, UK

    3 shared publications
  • Helen Bridle

    Affiliation Institute of Biological Chemistry, Biophysics and Bioengineering, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, United Kingdom

    2 shared publications

Latest Publications

  • Limitation of spiral microchannels for particle separation in heterogeneous mixtures: Impact of particles’ size and deformability

    by Ewa Guzniczak, Timm Krüger, Helen Bridle, Melanie Jimenez

    Spiral microchannels have shown promising results for separation applications. Hydrodynamic particle–particle interactions are a known factor strongly influencing focusing behaviors in inertial devices, with recent work highlighting how the performance of bidisperse mixtures is altered when compared with pure components in square channels. This phenomenon has not been previously investigated in detail for spiral channels. Here, we demonstrate that, in spiral channels, both the proportion and deformability of larger particles (13 μm diameter) impact upon the recovery (up to 47% decrease) of small rigid particles (4 μm). The effect, observed at low concentrations (volume fraction <0.0012), is attributed to the hydrodynamic capture of beads by larger cells. These changes in particles focusing behavior directly impede the efficiency of the separation—diverting beads from locations expected from measurements with pure populations to co-collection with larger cells—and could hamper deployment of technology for certain applications. Similar focusing behavior alterations were noted when working with purification of stem cell end products.


  • Open Access

    Correction: Deformability-induced lift force in spiral microchannels for cell separation

    by Ewa Guzniczak, Oliver Otto, Graeme Whyte, Nicholas Willoughby, Melanie Jimenez, Helen Bridle

    Correction for ‘Deformability-induced lift force in spiral microchannels for cell separation’ by Ewa Guzniczak et al., Lab Chip, 2020, 20, 614–625.


  • Open Access

    Purifying stem cell‐derived red blood cells: a high‐throughput label‐free downstream processing strategy based on microfluidic spiral inertial separation and membrane filtration

    by Ewa Guzniczak, Oliver Otto, Graeme Whyte, Tamir Chandra, Neil A. Robertson, Nik Willoughby, Melanie Jimenez, Helen Bridle

    Cell‐based therapeutics, such as in vitro manufactured red blood cells (mRBC), are different to traditional biopharmaceutical products (the final product being the cells themselves as opposed to biological molecules such as proteins) and that presents a challenge of developing new robust and economically feasible manufacturing processes, especially for sample purification. Current purification technologies have limited throughput, rely on expensive fluorescent or magnetic immuno‐labelling with a significant (up to 70%) cell loss and quality impairment. To address this challenge, previously characterised mechanical properties of umbilical cord blood CD34+ cells undergoing in vitro erythropoiesis were used to develop a mRBC purification strategy. The approach consists of two main stages: (1) a microfluidic separation using inertial focusing for deformability‐based sorting of enucleated cells (mRBC) from nuclei and nucleated cells resulting in 70% purity and (2) membrane filtration to enhance the purity to 99%. Herein, we propose a new route for high‐throughput (processing millions of cells /min and mls of medium /min) purification process for mRBC, leading to high mRBC purity while maintaining cells integrity and no alterations in their global gene expression profile. Further adaption of this separation approach offers a potential route for processing of a wide range of cellular products.


  • Open Access

    Deformability-induced lift force in spiral microchannels for cell separation

    by Ewa Guzniczak, Oliver Otto, Graeme Whyte, Nicholas Willoughby, Melanie Jimenez, Helen Bridle

    We introduce a novel combination of deformability-induced lift force ( F D ) and secondary Dean flow in spiral microchannel translated into a label-free purification approach applicable to mammalian cells, processing of millions of cells per min, up to high purities and recovery.


  • Open Access

    Cardiomyocyte mechanodynamics under conditions of actin remodelling

    by Ricardo H. Pires, Nithya Shree, Emmanuel Manu, Ewa Guzniczak, Oliver Otto

    The mechanical performance of cardiomyocytes (CMs) is an important indicator of their maturation state and of primary importance for the development of therapies based on cardiac stem cells. As the mechanical analysis of adherent cells at high-throughput remains challenging, we explore the applicability of real-time deformability cytometry (RT-DC) to probe cardiomyocytes in suspension. RT-DC is a microfluidic technology allowing for real-time mechanical analysis of thousands of cells with a throughput exceeding 1000 cells per second. For CMs derived from human-induced pluripotent stem cells, we determined a Young's modulus of 1.25 ± 0.08 kPa which is in close range to previous reports. Upon challenging the cytoskeleton with cytochalasin D (CytoD) to induce filamentous actin depolymerization, we distinguish three different regimes in cellular elasticity. Transitions are observed below 10 nM and above 10 3 nM and are characterized by a decrease in Young's modulus. These regimes can be linked to cytoskeletal and sarcomeric actin contributions by CM contractility measurements at varying CytoD concentrations, where we observe a significant reduction in pulse duration only above 10 3 nM while no change is found for compound exposure at lower concentrations. Comparing our results to mechanical cell measurements using atomic force microscopy, we demonstrate for the first time to our knowledge, the feasibility of using a microfluidic technique to measure mechanical properties of large samples of adherent cells while linking our results to the composition of the cytoskeletal network. This article is part of a discussion meeting issue ‘Single cell ecology'.


  • Impact of poloxamer 188 (Pluronic F-68) additive on cell mechanical properties, quantification by real-time deformability cytometry

    by Ewa Guzniczak, Melanie Jimenez, Matthew Irwin, Oliver Otto, Nicholas Willoughby, Helen Bridle

    Advances in cellular therapies have led to the development of new approaches for cell product purification and formulation, e.g., utilizing cell endogenous properties such as size and deformability as a basis for separation from potentially harmful undesirable by-products. However, commonly used additives such as Pluronic F-68 and other poloxamer macromolecules can change the mechanical properties of cells and consequently alter their processing. In this paper, we quantified the short-term effect of Pluronic F-68 on the mechanotype of three different cell types (Jurkat cells, red blood cells, and human embryonic kidney cells) using real-time deformability cytometry. The impact of the additive concentration was assessed in terms of cell size and deformability. We observed that cells respond progressively to the presence of Pluronic F-68 within first 3 h of incubation and become significantly stiffer (p-value < 0.001) in comparison to a serum-free control and a control containing serum. We also observed that the short-term response manifested as cell stiffening is true (p-value < 0.001) for the concentration reaching 1% (w/v) of the poloxamer additive in tested buffers. Additionally, using flow cytometry, we assessed that changes in cell deformability triggered by addition of Pluronic F-68 are not accompanied by size or viability alterations.


  • Open Access

    High-throughput assessment of mechanical properties of stem cell derived red blood cells, toward cellular downstream processing

    by Ewa Guzniczak, Maryam Mohammad Zadeh, Fiona Dempsey, Melanie Jimenez, Henry Bock, Graeme Whyte, Nicholas Willoughby, Helen Bridle

    Stem cell products, including manufactured red blood cells, require efficient sorting and purification methods to remove components potentially harmful for clinical application. However, standard approaches for cellular downstream processing rely on the use of specific and expensive labels (e.g. FACS or MACS). Techniques relying on inherent mechanical and physical properties of cells offer high-throughput scalable alternatives but knowledge of the mechanical phenotype is required. Here, we characterized for the first time deformability and size changes in CD34+ cells, and expelled nuclei, during their differentiation process into red blood cells at days 11, 14, 18 and 21, using Real-Time Deformability Cytometry (RT-DC) and Atomic Force Microscopy (AFM). We found significant differences (p < 0.0001; standardised mixed model) between the deformability of nucleated and enucleated cells, while they remain within the same size range. Expelled nuclei are smaller thus could be removed by size-based separation. An average Young’s elastic modulus was measured for nucleated cells, enucleated cells and nuclei (day 14) of 1.04 ± 0.47 kPa, 0.53 ± 0.12 kPa and 7.06 ± 4.07 kPa respectively. Our identification and quantification of significant differences (p < 0.0001; ANOVA) in CD34+ cells mechanical properties throughout the differentiation process could enable development of new routes for purification of manufactured red blood cells.