Pablo Garcia-Carreno
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pablo Garcia-Carreno has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Jose-Antonio Lopez-Perez
Centro de Desarrollos Tecnológicos, Observatorio de Yebes (IGN)
7 shared publications - Felix Tercero
Centro de Desarrollos Tecnológicos, Observatorio de Yebes (IGN)
4 shared publications - Isaac Lopez Fernandez
Centro de Desarrollos Tecnológicos, Observatorio de Yebes (IGN), 19141 Yebes, Guadalajara, Spain
4 shared publications - María Patino-Esteban
Yebes Observatory, Centro de Desarrollos Tecnológicos, Instituto Geográfico Nacional, Ministerio de Transportes, Movilidad y Agenda Urbana, Cerro de la Palera s.n., 19141 Yebes, Spain
4 shared publications - Pablo de Vicente
10Yebes Observatory, Instituto Geográfico Nacional, Cerro de la Palera, Yebes, Guadalajara, 19143, Spain
4 shared publications F. Beltrán
Centro de Desarrollos Tecnológicos, Observatorio de Yebes (IGN)
3 shared publications
Latest Publications
- Open Access
- 7 January 2026
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 705, A17
A new broad K/Ka-band receiver (18.0–32.3 GHz) for the Yebes Observatory’s 40 meter radio telescope
Since 2010, the 40 m radio telescope of the Yebes Observatory has been devoted to very long baseline interferometry (VLBI) and single-dish observations. Up until 2019, it covered frequency bands between 2 GHz and 90 GHz in discontinuous and narrow radio windows that met the needs of the European VLBI Network (EVN) and the Global Millimeter VLBI Array (GMVA). The situation changed in 2019 when new receivers were built and installed at the telescope for the Q- (31.5–50 GHz) and W- (72–90.5 GHz) bands in the frame of the Nanocosmos 1 project, a synergy project funded by the European Research Council. The 18.5 GHz instantaneous bandwidth is now fully covered in the two polarisations with 16 fast Fourier transform (FFT) spectrometers of 38 kHz resolution. This has allowed us to achieve an unprecedented level of ultra-sensitivity for line surveys, leading to the discovery of around 95 molecules in space over the last six years. These results have encouraged the construction of a new low-noise cryogenic receiver between 18 GHz and 32.3 GHz for the 40 m radio telescope with orthogonal polarisations (H & V) and 19 kHz of spectral resolution. Due to the frequency resolution requirement and the limited number of FFT boards, the band has been split into two sub-bands for each polarisation: low-band (18–26 GHz) and high-band (26–32.3 GHz), with eight FFT spectrometers of 1 GHz instantaneous bandwidths per sub-band and per polarisation. Alternatively, the receiver can be configured to analyze the full receiver band (18–32.3 GHz) in a single polarisation (either H-pol or V-pol). Here, we present the characteristics of the receiver and the first astrophysical results demonstrating its performance. A detailed analysis of the radio frequency interferences (RFIs) generated by satellite down-link communications and its impact on spectroscopic studies of the interstellar and circumstellar media is also provided. In this context, we conclude that the radio astronomy community must continue to strive to protect the still RFI-free K/Ka radio windows from harmful radiocommunication signals.
- 7 January 2026
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 705, A17
Open AccessA new broad K/Ka-band receiver (18.0–32.3 GHz) for the Yebes Observatory’s 40 meter radio telescope
Since 2010, the 40 m radio telescope of the Yebes Observatory has been devoted to very long baseline interferometry (VLBI) and single-dish observations. Up until 2019, it covered frequency bands between 2 GHz and 90 GHz in discontinuous and narrow radio windows that met the needs of the European VLBI Network (EVN) and the Global Millimeter VLBI Array (GMVA). The situation changed in 2019 when new receivers were built and installed at the telescope for the Q- (31.5–50 GHz) and W- (72–90.5 GHz) bands in the frame of the Nanocosmos 1 project, a synergy project funded by the European Research Council. The 18.5 GHz instantaneous bandwidth is now fully covered in the two polarisations with 16 fast Fourier transform (FFT) spectrometers of 38 kHz resolution. This has allowed us to achieve an unprecedented level of ultra-sensitivity for line surveys, leading to the discovery of around 95 molecules in space over the last six years. These results have encouraged the construction of a new low-noise cryogenic receiver between 18 GHz and 32.3 GHz for the 40 m radio telescope with orthogonal polarisations (H & V) and 19 kHz of spectral resolution. Due to the frequency resolution requirement and the limited number of FFT boards, the band has been split into two sub-bands for each polarisation: low-band (18–26 GHz) and high-band (26–32.3 GHz), with eight FFT spectrometers of 1 GHz instantaneous bandwidths per sub-band and per polarisation. Alternatively, the receiver can be configured to analyze the full receiver band (18–32.3 GHz) in a single polarisation (either H-pol or V-pol). Here, we present the characteristics of the receiver and the first astrophysical results demonstrating its performance. A detailed analysis of the radio frequency interferences (RFIs) generated by satellite down-link communications and its impact on spectroscopic studies of the interstellar and circumstellar media is also provided. In this context, we conclude that the radio astronomy community must continue to strive to protect the still RFI-free K/Ka radio windows from harmful radiocommunication signals.
- Open Access
New Cable Delay Measurement System for VGOS Stations
This paper presents the new cable delay measurement system (CDMS) designed at Yebes Observatory (IGN, Spain), which is required for the VLBI Global Observing System (VGOS) stations. This system measures the phase difference between the 5 MHz reference signal from the hydrogen maser and the 5 MHz signal that reaches the broadband receiver through a coaxial cable, for the generation of calibration tones. As a result, the system detects the changes in the length of that coaxial cable due to temperature variations along the cable run and flexures caused by VGOS radio telescope movements. This CDMS outperforms the previous versions: firstly, it does not require a frequency counter for phase/delay measurements; secondly, it largely reduces the use of digital circuits; hence, reducing digital noise; and thirdly, it has a remotely controlled automatic calibration subsystem. The system was tested in the laboratory and in the radio telescope, and the measurements of both set-ups are shown. These measurements include the total noise, accuracy, hysteresis, and stability. The results in the radio telescope can be correlated with the different factors that affect the cable, such as temperature and flexures. The system allows to achieve an RMS noise of less than 0.5 ps, significantly improving the requirements established in VGOS. The system is currently installed in the Red Atlántica de Estaciones Geodinámicas y Espaciales (RAEGE)Yebes VGOS 13.2 m radio telescope, and will be installed in the Norwegian Mapping Authority (NMA) twin VGOS radio telescopes, in the Finnish Geospatial Research Institute (FGI) VGOS station and in the RAEGE Santa María VGOS radio telescope (Açores, Portugal).
Open AccessNew Cable Delay Measurement System for VGOS Stations
This paper presents the new cable delay measurement system (CDMS) designed at Yebes Observatory (IGN, Spain), which is required for the VLBI Global Observing System (VGOS) stations. This system measures the phase difference between the 5 MHz reference signal from the hydrogen maser and the 5 MHz signal that reaches the broadband receiver through a coaxial cable, for the generation of calibration tones. As a result, the system detects the changes in the length of that coaxial cable due to temperature variations along the cable run and flexures caused by VGOS radio telescope movements. This CDMS outperforms the previous versions: firstly, it does not require a frequency counter for phase/delay measurements; secondly, it largely reduces the use of digital circuits; hence, reducing digital noise; and thirdly, it has a remotely controlled automatic calibration subsystem. The system was tested in the laboratory and in the radio telescope, and the measurements of both set-ups are shown. These measurements include the total noise, accuracy, hysteresis, and stability. The results in the radio telescope can be correlated with the different factors that affect the cable, such as temperature and flexures. The system allows to achieve an RMS noise of less than 0.5 ps, significantly improving the requirements established in VGOS. The system is currently installed in the Red Atlántica de Estaciones Geodinámicas y Espaciales (RAEGE)Yebes VGOS 13.2 m radio telescope, and will be installed in the Norwegian Mapping Authority (NMA) twin VGOS radio telescopes, in the Finnish Geospatial Research Institute (FGI) VGOS station and in the RAEGE Santa María VGOS radio telescope (Açores, Portugal).
- Open Access
A Tri-Band Cooled Receiver for Geodetic VLBI
This paper shows a simultaneous tri-band (S: 2.2–2.7 GHz, X: 7.5–9 GHz and Ka: 28–33 GHz) low-noise cryogenic receiver for geodetic Very Long Baseline Interferometry (geo-VLBI) which has been developed at Yebes Observatory laboratories in Spain. A special feature is that the whole receiver front-end is fully coolable down to cryogenic temperatures to minimize receiver noise. It was installed in the first radio telescope of the Red Atlántica de Estaciones Geodinámicas y Espaciales (RAEGE) project, which is located in Yebes Observatory, in the frame of the VLBI Global Observing System (VGOS). After this, the receiver was borrowed by the Norwegian Mapping Autorithy (NMA) for the commissioning of two VGOS radiotelescopes in Svalbard (Norway). A second identical receiver was built for the Ishioka VGOS station of the Geospatial Information Authority (GSI) of Japan, and a third one for the second RAEGE VGOS station, located in Santa María (Açores Archipelago, Portugal). The average receiver noise temperatures are 21, 23, and 25 Kelvin and the measured antenna efficiencies are 70%, 75%, and 60% in S-band, X-band, and Ka-band, respectively.
Open AccessA Tri-Band Cooled Receiver for Geodetic VLBI
This paper shows a simultaneous tri-band (S: 2.2–2.7 GHz, X: 7.5–9 GHz and Ka: 28–33 GHz) low-noise cryogenic receiver for geodetic Very Long Baseline Interferometry (geo-VLBI) which has been developed at Yebes Observatory laboratories in Spain. A special feature is that the whole receiver front-end is fully coolable down to cryogenic temperatures to minimize receiver noise. It was installed in the first radio telescope of the Red Atlántica de Estaciones Geodinámicas y Espaciales (RAEGE) project, which is located in Yebes Observatory, in the frame of the VLBI Global Observing System (VGOS). After this, the receiver was borrowed by the Norwegian Mapping Autorithy (NMA) for the commissioning of two VGOS radiotelescopes in Svalbard (Norway). A second identical receiver was built for the Ishioka VGOS station of the Geospatial Information Authority (GSI) of Japan, and a third one for the second RAEGE VGOS station, located in Santa María (Açores Archipelago, Portugal). The average receiver noise temperatures are 21, 23, and 25 Kelvin and the measured antenna efficiencies are 70%, 75%, and 60% in S-band, X-band, and Ka-band, respectively.
- 5 January 2021
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 645, A37
Yebes 40 m radio telescope and the broad band Nanocosmos receivers at 7 mm and 3 mm for line surveys
Context. Yebes 40 m radio telescope is the main and largest observing instrument at Yebes Observatory and is devoted to very long baseline interferometry (VLBI) and single-dish observations since 2010. It has been covering frequency bands between 2 GHz and 90 GHz in discontinuous and narrow windows in most cases in order to match the current needs of the European VLBI Network (EVN) and the Global Millimeter VLBI Array (GMVA). Aims. The Nanocosmos project, a European Union-funded synergy grant, has enabled an increase in the instantaneous frequency coverage of the Yebes 40 m radio telescope, making it possible to observe many molecular transitions with single tunings in single-dish mode. This reduces the observing time and maximises the output from the telescope. Methods. We present technical specifications of the recently installed 31.5−50 GHz (Q band) and 72−90.5 GHz (W band) receivers along with the main characteristics of the telescope at these frequency ranges. We observed IRC+10216, CRL 2688, and CRL 618, which harbour a rich molecular chemistry, to demonstrate the capabilities of the new instrumentation for spectral observations in single-dish mode. Results. Our results show the high sensitivity of the telescope in the Q band. The spectrum of IRC+10126 offers an unprecedented signal-to-noise ratio for this source in this band. On the other hand, the spectrum normalised by the continuum flux towards CRL 618 in the W band demonstrates that the 40 m radio telescope produces comparable results to those from the IRAM 30 m radio telescope, although with a lower sensitivity. The new receivers fulfil one of the main goals of Nanocosmos and open up the possibility to study the spectrum of different astrophysical media with unprecedented sensitivity.
- 5 January 2021
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 645, A37
Yebes 40 m radio telescope and the broad band Nanocosmos receivers at 7 mm and 3 mm for line surveys
Context. Yebes 40 m radio telescope is the main and largest observing instrument at Yebes Observatory and is devoted to very long baseline interferometry (VLBI) and single-dish observations since 2010. It has been covering frequency bands between 2 GHz and 90 GHz in discontinuous and narrow windows in most cases in order to match the current needs of the European VLBI Network (EVN) and the Global Millimeter VLBI Array (GMVA). Aims. The Nanocosmos project, a European Union-funded synergy grant, has enabled an increase in the instantaneous frequency coverage of the Yebes 40 m radio telescope, making it possible to observe many molecular transitions with single tunings in single-dish mode. This reduces the observing time and maximises the output from the telescope. Methods. We present technical specifications of the recently installed 31.5−50 GHz (Q band) and 72−90.5 GHz (W band) receivers along with the main characteristics of the telescope at these frequency ranges. We observed IRC+10216, CRL 2688, and CRL 618, which harbour a rich molecular chemistry, to demonstrate the capabilities of the new instrumentation for spectral observations in single-dish mode. Results. Our results show the high sensitivity of the telescope in the Q band. The spectrum of IRC+10126 offers an unprecedented signal-to-noise ratio for this source in this band. On the other hand, the spectrum normalised by the continuum flux towards CRL 618 in the W band demonstrates that the 40 m radio telescope produces comparable results to those from the IRAM 30 m radio telescope, although with a lower sensitivity. The new receivers fulfil one of the main goals of Nanocosmos and open up the possibility to study the spectrum of different astrophysical media with unprecedented sensitivity.
- Open Access
- 7 June 2019
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 626, A34
Broad-band high-resolution rotational spectroscopy for laboratory astrophysics
We present a new experimental set-up devoted to the study of gas phase molecules and processes using broad-band high spectral resolution rotational spectroscopy. A reactor chamber is equipped with radio receivers similar to those used by radio astronomers to search for molecular emission in space. The whole range of the Q (31.5–50 GHz) and W bands (72–116.5 GHz) is available for rotational spectroscopy observations. The receivers are equipped with 16 × 2.5 GHz fast Fourier transform spectrometers with a spectral resolution of 38.14 kHz allowing the simultaneous observation of the complete Q band and one-third of the W band. The whole W band can be observed in three settings in which the Q band is always observed. Species such as CH3CN, OCS, and SO2 are detected, together with many of their isotopologues and vibrationally excited states, in very short observing times. The system permits automatic overnight observations, and integration times as long as 2.4 × 105 s have been reached. The chamber is equipped with a radiofrequency source to produce cold plasmas, and with four ultraviolet lamps to study photochemical processes. Plasmas of CH4, N2, CH3CN, NH3, O2, and H2, among other species, have been generated and the molecular products easily identified by the rotational spectrum, and via mass spectrometry and optical spectroscopy. Finally, the rotational spectrum of the lowest energy conformer of CH3CH2NHCHO (N-ethylformamide), a molecule previously characterized in microwave rotational spectroscopy, has been measured up to 116.5 GHz, allowing the accurate determination of its rotational and distortion constants and its search in space.
- 7 June 2019
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 626, A34
Open AccessBroad-band high-resolution rotational spectroscopy for laboratory astrophysics
We present a new experimental set-up devoted to the study of gas phase molecules and processes using broad-band high spectral resolution rotational spectroscopy. A reactor chamber is equipped with radio receivers similar to those used by radio astronomers to search for molecular emission in space. The whole range of the Q (31.5–50 GHz) and W bands (72–116.5 GHz) is available for rotational spectroscopy observations. The receivers are equipped with 16 × 2.5 GHz fast Fourier transform spectrometers with a spectral resolution of 38.14 kHz allowing the simultaneous observation of the complete Q band and one-third of the W band. The whole W band can be observed in three settings in which the Q band is always observed. Species such as CH3CN, OCS, and SO2 are detected, together with many of their isotopologues and vibrationally excited states, in very short observing times. The system permits automatic overnight observations, and integration times as long as 2.4 × 105 s have been reached. The chamber is equipped with a radiofrequency source to produce cold plasmas, and with four ultraviolet lamps to study photochemical processes. Plasmas of CH4, N2, CH3CN, NH3, O2, and H2, among other species, have been generated and the molecular products easily identified by the rotational spectrum, and via mass spectrometry and optical spectroscopy. Finally, the rotational spectrum of the lowest energy conformer of CH3CH2NHCHO (N-ethylformamide), a molecule previously characterized in microwave rotational spectroscopy, has been measured up to 116.5 GHz, allowing the accurate determination of its rotational and distortion constants and its search in space.
- Open Access
- 14 December 2018
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 51 (32) , 34-39
Robust Disturbance Rejection by the Attractive Ellipsoid Method – Part I: Continuous-time Systems
- 14 December 2018
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 51 (32) , 34-39
Open AccessRobust Disturbance Rejection by the Attractive Ellipsoid Method – Part I: Continuous-time Systems
- Open Access
- 12 April 2018
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 12 (8) , 1293-1301
Superconducting spiral bandpass filter designed by a pseudo‐Fourier technique
An iterative technique to adjust ripple in a bandpass filter has been developed by curve‐fitting numerical data. It gives an approximate relation of ripple against filter coupling coefficients and resonator resonant frequencies instead of finding a Jacobian matrix for each individual filter, in exchange for making more iterations. Numerical examples show reasonable convergence for Chebyshev filters up to the 16th‐order, coupled quadruplets, coupled triplets and folded cross‐coupled filters. A bandpass filter for a radio telescope in Yebes, Spain is designed and measured, a tenth‐order superconducting spiral filter with 7% bandwidth, 2295 MHz centre frequency, <0.1 dB ripple and overall substrate size 30 mm × 8 mm. The 11 iterative simulations totalled 8.5 h of computer processing time.
- 12 April 2018
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 12 (8) , 1293-1301
Open AccessSuperconducting spiral bandpass filter designed by a pseudo‐Fourier technique
An iterative technique to adjust ripple in a bandpass filter has been developed by curve‐fitting numerical data. It gives an approximate relation of ripple against filter coupling coefficients and resonator resonant frequencies instead of finding a Jacobian matrix for each individual filter, in exchange for making more iterations. Numerical examples show reasonable convergence for Chebyshev filters up to the 16th‐order, coupled quadruplets, coupled triplets and folded cross‐coupled filters. A bandpass filter for a radio telescope in Yebes, Spain is designed and measured, a tenth‐order superconducting spiral filter with 7% bandwidth, 2295 MHz centre frequency, <0.1 dB ripple and overall substrate size 30 mm × 8 mm. The 11 iterative simulations totalled 8.5 h of computer processing time.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 136, 476-479
Geodetic VLBI ultra low noise broad-band receiver for 13 meter VGOS radiotelescopes
This paper shows the design, construction and characterization of an ultra-low noise and broad-band receiver system, to be used for geodetic very long baseline interferometry (VLBI) observations with the Spanish new 13.2 meter radiotelescopes, in the frame of the VLBI Global Observing System (VGOS). The cryogenic receiver front-end covers the frequency range 2-14 GHz in two simultaneous linear polarizations. It has an average receiver noise temperature lower than 20 Kelvin, except for those frequencies affected by radio frequency intereferences (RFI). The detected signals are sent to the back-end room using broad-band RF over fiber optic links. Then, the signals are distributed to four dual-channel frequency up/down converters, which provide the base-band signals for the digital VLBI back-ends.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 136, 476-479
Geodetic VLBI ultra low noise broad-band receiver for 13 meter VGOS radiotelescopes
This paper shows the design, construction and characterization of an ultra-low noise and broad-band receiver system, to be used for geodetic very long baseline interferometry (VLBI) observations with the Spanish new 13.2 meter radiotelescopes, in the frame of the VLBI Global Observing System (VGOS). The cryogenic receiver front-end covers the frequency range 2-14 GHz in two simultaneous linear polarizations. It has an average receiver noise temperature lower than 20 Kelvin, except for those frequencies affected by radio frequency intereferences (RFI). The detected signals are sent to the back-end room using broad-band RF over fiber optic links. Then, the signals are distributed to four dual-channel frequency up/down converters, which provide the base-band signals for the digital VLBI back-ends.