Daisuke Setoguchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daisuke Setoguchi has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Koichi Kinoshita
Department of Orthopaedic Surgery, Fukuoka University Faculty of Medicine, Fukuoka, Japan
2 shared publicationsTakuaki Yamamoto
Department of Orthopaedic Surgery, Fukuoka University Faculty of Medicine, Fukuoka, Japan
2 shared publicationsEtsuji Shiota
Department of Rehabilitation Medicine, Fukuoka University Hospital, Fukuoka, Japan
1 shared publicationKoichi Uehara
Laboratory of Plant Morphology, Faculty of Horticulture, Chiba University, 648 Matsudo, Chiba, 271–8510, Japan
1 shared publicationKyosuke Goto
Department of Rehabilitation Medicine, Fukuoka University Hospital, Fukuoka, Japan
1 shared publicationMasami Watanabe
Laboratory of Plant Nutrition
1 shared publication
Latest Publications
- 2 January 2020
- Published by Taylor & Francis in Assistive Technology
- Vol. 34 (1) , 112-120
Hybrid Assistive Limb improves restricted hip extension after total hip arthroplasty
The Hybrid Assistive Limb (HAL) was developed as an exoskeleton robot that supports gait training. The purpose of this study was to assess the usefulness of training using the HAL after total hip arthroplasty (THA). We targeted 16 consecutive patients who underwent THA via the posterior approach. We randomized patients to the HAL group (8 hips), in which the HAL was used as part of physical therapy, or the control group (8 hips), in which only typical physical therapy was performed. Gait analysis was performed before and after surgery, and comparisons were made between the two groups. We evaluated the single support time (%), double support time (%), cadence (steps/min), velocity (cm/s), stride length (cm), and anteroposterior and lateral variability, and assessed the hip and knee joint range of motion in the sagittal plane. The results showed improvements in the hip extension angle and other gait parameters in the HAL group. Among gait-related problems after THA, a decreased peak hip extension angle is reported to be a significant factor that affects gait disability. This study revealed that HAL usage after THA seems to be a useful method to obtain sufficient extension angle.
- 2 January 2020
- Published by Taylor & Francis in Assistive Technology
- Vol. 34 (1) , 112-120
Hybrid Assistive Limb improves restricted hip extension after total hip arthroplasty
The Hybrid Assistive Limb (HAL) was developed as an exoskeleton robot that supports gait training. The purpose of this study was to assess the usefulness of training using the HAL after total hip arthroplasty (THA). We targeted 16 consecutive patients who underwent THA via the posterior approach. We randomized patients to the HAL group (8 hips), in which the HAL was used as part of physical therapy, or the control group (8 hips), in which only typical physical therapy was performed. Gait analysis was performed before and after surgery, and comparisons were made between the two groups. We evaluated the single support time (%), double support time (%), cadence (steps/min), velocity (cm/s), stride length (cm), and anteroposterior and lateral variability, and assessed the hip and knee joint range of motion in the sagittal plane. The results showed improvements in the hip extension angle and other gait parameters in the HAL group. Among gait-related problems after THA, a decreased peak hip extension angle is reported to be a significant factor that affects gait disability. This study revealed that HAL usage after THA seems to be a useful method to obtain sufficient extension angle.
- 11 July 2019
- Published by SAGE Publications in HIP International
- Vol. 30 (6) , 718-724
The short external rotators dissection during the posterior approach in total hip arthroplasty did not change the blood flow
Objectives: The posterior approach in total hip arthroplasty (THA) often requires dissection of the short external rotators (SERs), which could increase the postoperative dislocation rate. The reattachment of the dissected SERs has been reported to reduce the dislocation rate, while such repair generally causes progression of muscle atrophy. 1 of the suggested causes of atrophy is reduced blood flow to the repaired SERs. The present study aimed to measure the blood flow of the SERs before dissection (pre-tenotomy) and after reattachment (post-reattachment) during the posterior approach in THA. Methods: This prospective study included 26 patients who underwent THA via the posterior approach. A laser-Doppler rheometer was used to measure the blood flow in the following SERs at the time of pre-tenotomy and post-reattachment: the piriformis muscle (PM), superior gemellus (SG), inferior gemellus (IG), obturator internus (OI), and subcutaneous tissue as a control. Results: The average pre-tenotomy and post-reattachment blood flows (mL/minutes/100 g) were: 1.90 ± 0.28 and 1.92 ± 0.40 in the PM, 1.94 ± 0.20 and 1.99 ± 0.39 in the SG, 1.91 ± 0.21 and 1.94 ± 0.30 in the IG, 1.93 ± 0.22 and 1.98 ± 0.36 in the OI, and 1.94 ± 0.24 and 1.87 ± 0.38 in the subcutaneous tissue. The pre-tenotomy and post-reattachment blood flows did not show significant difference in any muscle. Conclusions: Laser-Doppler blood flow measurements showed that the blood flow is preserved, even when the SERs are dissected and reattached in THA via the posterior approach.
- 11 July 2019
- Published by SAGE Publications in HIP International
- Vol. 30 (6) , 718-724
The short external rotators dissection during the posterior approach in total hip arthroplasty did not change the blood flow
Objectives: The posterior approach in total hip arthroplasty (THA) often requires dissection of the short external rotators (SERs), which could increase the postoperative dislocation rate. The reattachment of the dissected SERs has been reported to reduce the dislocation rate, while such repair generally causes progression of muscle atrophy. 1 of the suggested causes of atrophy is reduced blood flow to the repaired SERs. The present study aimed to measure the blood flow of the SERs before dissection (pre-tenotomy) and after reattachment (post-reattachment) during the posterior approach in THA. Methods: This prospective study included 26 patients who underwent THA via the posterior approach. A laser-Doppler rheometer was used to measure the blood flow in the following SERs at the time of pre-tenotomy and post-reattachment: the piriformis muscle (PM), superior gemellus (SG), inferior gemellus (IG), obturator internus (OI), and subcutaneous tissue as a control. Results: The average pre-tenotomy and post-reattachment blood flows (mL/minutes/100 g) were: 1.90 ± 0.28 and 1.92 ± 0.40 in the PM, 1.94 ± 0.20 and 1.99 ± 0.39 in the SG, 1.91 ± 0.21 and 1.94 ± 0.30 in the IG, 1.93 ± 0.22 and 1.98 ± 0.36 in the OI, and 1.94 ± 0.24 and 1.87 ± 0.38 in the subcutaneous tissue. The pre-tenotomy and post-reattachment blood flows did not show significant difference in any muscle. Conclusions: Laser-Doppler blood flow measurements showed that the blood flow is preserved, even when the SERs are dissected and reattached in THA via the posterior approach.
- Open Access
- 24 November 2002
- Published by Wiley in New Phytologist
- Vol. 156 (3) , 417-426
Apoptosis‐like cell death of Brassica napus leaf protoplasts
• The cleavage of nuclear DNA into oligonucleosomal fragments that is the hallmark of apoptosis in animal cells occurs during the culture of Brass...
- 24 November 2002
- Published by Wiley in New Phytologist
- Vol. 156 (3) , 417-426
Open AccessApoptosis‐like cell death of Brassica napus leaf protoplasts
• The cleavage of nuclear DNA into oligonucleosomal fragments that is the hallmark of apoptosis in animal cells occurs during the culture of Brass...