Haifeng Zong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haifeng Zong has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Chuanzhong Yang
Department of Neonatology, Shenzhen Maternity and Child Healthcare Hospital, The First School of Clinical Medicine, Southern Medical University, Shenzhen, China
10 shared publications Guo Guo
Department of Neonatology and NICU, Beijing Chaoyang District Maternal and Child Healthcare Hospital, Beijing, China
4 shared publications- Jing Liu
Department of Neonatology and NICU, Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing Maternal and Child Health Care Hospital, China
4 shared publications Yingsui Huang
Neonatal Intensive Care Unit, Shenzhen Maternity and Child Healthcare Hospital, Women and Children's Medical Center Southern Medical University Shenzhen China
4 shared publicationsBingchun Lin
Neonatal Intensive Care Unit, Shenzhen Maternity and Child Healthcare Hospital, Women and Children's Medical Center Southern Medical University Shenzhen China
3 shared publicationsHongyan Sun
Neonatal Intensive Care Unit, Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, China
3 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Wiley in The Clinical Respiratory Journal
- Vol. 20 (9) , e70228
Pulmonary Surfactant Treatment for Preterm Infants With Respiratory Distress Syndrome: A Nationwide Survey
Background: Pulmonary surfactant is essential for neonatal respiratory distress syndrome (RDS) management, yet national data on how surfactant is used in China are limited. We surveyed current practices and variation in surfactant availability and administration. Methods: In October–December 2022, a nationwide cross‐sectional online survey was completed by one neonatologist from each of 394 hospitals across 30 provinces. Items covered surfactant availability (including delivery room access), product selection, dosing, timing, and administration techniques. Results: Surfactant was available in 96.7% of hospitals; poractant alfa and calsurf were available in 88.6% and 58.1%, respectively. Only 51.6% of hospitals reported surfactant availability in delivery rooms. For the first dose, 200 mg/kg was preferred for poractant alfa (68.8%) and 100 mg/kg for calsurf (63.8%). The reported median time to first dose was 2.0 h after birth; poractant alfa was administered sooner than calsurf (10 vs. 30 min estimated administration time; p < 0.001). Most respondents (79.7%) reported giving surfactant after noninvasive ventilation failure in infants who subsequently required mechanical ventilation, with higher use in tertiary vs. secondary hospitals (82.1% vs. 71.7%; p = 0.03). Intubation‐surfactant‐extubation (INSURE) and less invasive surfactant administration (LISA)/minimally invasive surfactant therapy (MIST) were available in 86.5% and 49.7% of hospitals, respectively. Additionally, 25.1% of the respondents reported combining a surfactant with glucocorticoids for treating RDS. Conclusion: Surfactant use in China shows substantial between‐hospital variation, particularly in delivery room access and less invasive administration. Standardized training and improved resource allocation may reduce disparities and support timely, evidence‐based surfactant therapy.
- 1 September 2026
- Published by Wiley in The Clinical Respiratory Journal
- Vol. 20 (9) , e70228
Open AccessPulmonary Surfactant Treatment for Preterm Infants With Respiratory Distress Syndrome: A Nationwide Survey
Background: Pulmonary surfactant is essential for neonatal respiratory distress syndrome (RDS) management, yet national data on how surfactant is used in China are limited. We surveyed current practices and variation in surfactant availability and administration. Methods: In October–December 2022, a nationwide cross‐sectional online survey was completed by one neonatologist from each of 394 hospitals across 30 provinces. Items covered surfactant availability (including delivery room access), product selection, dosing, timing, and administration techniques. Results: Surfactant was available in 96.7% of hospitals; poractant alfa and calsurf were available in 88.6% and 58.1%, respectively. Only 51.6% of hospitals reported surfactant availability in delivery rooms. For the first dose, 200 mg/kg was preferred for poractant alfa (68.8%) and 100 mg/kg for calsurf (63.8%). The reported median time to first dose was 2.0 h after birth; poractant alfa was administered sooner than calsurf (10 vs. 30 min estimated administration time; p < 0.001). Most respondents (79.7%) reported giving surfactant after noninvasive ventilation failure in infants who subsequently required mechanical ventilation, with higher use in tertiary vs. secondary hospitals (82.1% vs. 71.7%; p = 0.03). Intubation‐surfactant‐extubation (INSURE) and less invasive surfactant administration (LISA)/minimally invasive surfactant therapy (MIST) were available in 86.5% and 49.7% of hospitals, respectively. Additionally, 25.1% of the respondents reported combining a surfactant with glucocorticoids for treating RDS. Conclusion: Surfactant use in China shows substantial between‐hospital variation, particularly in delivery room access and less invasive administration. Standardized training and improved resource allocation may reduce disparities and support timely, evidence‐based surfactant therapy.
- Open Access
- 5 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (15) , 2474
The Diagnostic Value of Lung Ultrasound in Bronchopulmonary Dysplasia Among Preterm Infants with Gestational Age ≤ 28 Weeks
Objective: The aim of this study was to explore the diagnostic value of lung ultrasound (LUS) for bronchopulmonary dysplasia (BPD) in extremely premature infants. Methods: This was a prospective observational cohort study in which infants with gestational age (GA) ≤ 28+6 weeks were included. LUS was performed at least once a week until 36 weeks of postmenstrual age. The LUS characteristics of infants with moderate–severe BPD were compared with those of infants with non–mild BPD. Results: A total of 114 infants were included, of which 69 (60.5%) had non–mild BPD, and 45 (39.5%) had moderate–severe BPD. The mean GA and birth weight of infants with non–mild BPD and moderate–severe BPD were 27.0 ± 1.4 and 26.3 ± 1.6 weeks and 969 ± 184 and 802 ± 228 g, respectively. The proportions of rough pleural lines, fused B-lines, patch-like anechoic appearance on the pleural surface, subpleural speckled hyperechoic appearance, lung consolidation (≥0.5 cm), fuzzy or invisible A-lines, and pleural insect erosion (PIE)-like changes in the moderate–severe BPD group were significantly greater than those in the non–mild BPD group (100% vs. 37.7%, 88.9% vs. 13.0%, 84.4% vs. 7.2%, 73.3% vs. 8.7%, 80.0% vs. 11.6%, 86.7% vs. 10.1%, and 75.6% vs. 5.8%, respectively; p < 0.001). In evaluating moderate–severe BPD, rough pleura had 100.0% (95% CI: 0.921–1.000) in sensitivity, 63.4% (95% CI: 0.518–0.736) in PPV, and 62.3% (95% CI: 0.505–0.728) in specificity. PIE-like changes had 75.6% (95% CI: 0.613–0.858) in sensitivity, 89.5% (95% CI: 0.759–0.958) in PPV, and 94.2% (95% CI: 0.860–0.977) in specificity. Pleura surface irregular patch-like anechoic had 84.4% (95% CI: 0.712–0.923) in sensitivity, 88.4% (95% CI: 0.755–0.949) in PPV, and 92.8% (95% CI: 0.841–0.969) in specificity. Subpleural speckled hyperechogenicity had 73.3% (95% CI: 0.592–0.840) in sensitivity, 84.6% (95% CI: 0.704–0.930) in PPV, and 91.3% (95% CI: 0.824–0.960) in specificity. Conclusions: LUS is a valuable tool for evaluating and diagnosing BPD.
- 5 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (15) , 2474
Open AccessThe Diagnostic Value of Lung Ultrasound in Bronchopulmonary Dysplasia Among Preterm Infants with Gestational Age ≤ 28 Weeks
Objective: The aim of this study was to explore the diagnostic value of lung ultrasound (LUS) for bronchopulmonary dysplasia (BPD) in extremely premature infants. Methods: This was a prospective observational cohort study in which infants with gestational age (GA) ≤ 28+6 weeks were included. LUS was performed at least once a week until 36 weeks of postmenstrual age. The LUS characteristics of infants with moderate–severe BPD were compared with those of infants with non–mild BPD. Results: A total of 114 infants were included, of which 69 (60.5%) had non–mild BPD, and 45 (39.5%) had moderate–severe BPD. The mean GA and birth weight of infants with non–mild BPD and moderate–severe BPD were 27.0 ± 1.4 and 26.3 ± 1.6 weeks and 969 ± 184 and 802 ± 228 g, respectively. The proportions of rough pleural lines, fused B-lines, patch-like anechoic appearance on the pleural surface, subpleural speckled hyperechoic appearance, lung consolidation (≥0.5 cm), fuzzy or invisible A-lines, and pleural insect erosion (PIE)-like changes in the moderate–severe BPD group were significantly greater than those in the non–mild BPD group (100% vs. 37.7%, 88.9% vs. 13.0%, 84.4% vs. 7.2%, 73.3% vs. 8.7%, 80.0% vs. 11.6%, 86.7% vs. 10.1%, and 75.6% vs. 5.8%, respectively; p < 0.001). In evaluating moderate–severe BPD, rough pleura had 100.0% (95% CI: 0.921–1.000) in sensitivity, 63.4% (95% CI: 0.518–0.736) in PPV, and 62.3% (95% CI: 0.505–0.728) in specificity. PIE-like changes had 75.6% (95% CI: 0.613–0.858) in sensitivity, 89.5% (95% CI: 0.759–0.958) in PPV, and 94.2% (95% CI: 0.860–0.977) in specificity. Pleura surface irregular patch-like anechoic had 84.4% (95% CI: 0.712–0.923) in sensitivity, 88.4% (95% CI: 0.755–0.949) in PPV, and 92.8% (95% CI: 0.841–0.969) in specificity. Subpleural speckled hyperechogenicity had 73.3% (95% CI: 0.592–0.840) in sensitivity, 84.6% (95% CI: 0.704–0.930) in PPV, and 91.3% (95% CI: 0.824–0.960) in specificity. Conclusions: LUS is a valuable tool for evaluating and diagnosing BPD.
- Open Access
- 8 January 2026
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 39 (1) , 2611637
Lung ultrasound features during the evolution of BPD: a study from an animal model
To explore lung ultrasound (LUS) in the evolution of bronchopulmonary dysplasia (BPD) and the diagnostic value of LUS in BPD. Newborn rats were randomly assigned to the room air (RA) group or the oxygen (O2) group. LUS were performed at 12 h and on the 3rd, 7th, and 10th days to explore the LUS in BPD rats. Hematoxylin-eosin staining and immunohistochemical were analyzed to evaluate pathological characteristics. LUS score (LUSs) in the O2 group was significantly increased on the 7th and 10th days. In the early stage, LUS revealed multiple B-lines and air bronchograms. In the late stage, LUS revealed anechoic echoic areas on the pleural surface and scattered dot-like hyperechoic patterns in the lung field. The LUS findings were consistent with the pathological results. There was a strong positive correlation between LUS and pathological findings. LUS can be used to monitor the evolution of BPD.
- 8 January 2026
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 39 (1) , 2611637
Open AccessLung ultrasound features during the evolution of BPD: a study from an animal model
To explore lung ultrasound (LUS) in the evolution of bronchopulmonary dysplasia (BPD) and the diagnostic value of LUS in BPD. Newborn rats were randomly assigned to the room air (RA) group or the oxygen (O2) group. LUS were performed at 12 h and on the 3rd, 7th, and 10th days to explore the LUS in BPD rats. Hematoxylin-eosin staining and immunohistochemical were analyzed to evaluate pathological characteristics. LUS score (LUSs) in the O2 group was significantly increased on the 7th and 10th days. In the early stage, LUS revealed multiple B-lines and air bronchograms. In the late stage, LUS revealed anechoic echoic areas on the pleural surface and scattered dot-like hyperechoic patterns in the lung field. The LUS findings were consistent with the pathological results. There was a strong positive correlation between LUS and pathological findings. LUS can be used to monitor the evolution of BPD.
- Open Access
- 9 October 2025
- Published by Wiley in Clinical Case Reports
- Vol. 13 (10)
A Preterm Infant With Gestational Age of 21 +4 Weeks
We report a case of a male infant who was conceived through in vitro fertilization, with a gestational age of 21 +4 weeks. The infant was discharged home at 42 weeks' postmenstrual age without significant cranial morbidities.
- 9 October 2025
- Published by Wiley in Clinical Case Reports
- Vol. 13 (10)
Open AccessA Preterm Infant With Gestational Age of 21 +4 Weeks
We report a case of a male infant who was conceived through in vitro fertilization, with a gestational age of 21 +4 weeks. The infant was discharged home at 42 weeks' postmenstrual age without significant cranial morbidities.
- 14 January 2025
- Published by Springer Nature in Journal of Perinatology
- Vol. 45 (6) , 830-836
Accuracy of lung ultrasound in predicting successful extubation in preterm infants born ≤ 25 weeks
Objective The aim of this study was to examine the predictive value of the lung ultrasound score (LUS) for successful extubation in preterm infants born at ≤25+6 weeks. Methods This was a single-center, prospective cohort study. Preterm infants with gestational age (GA) ≤ 25+6 weeks who received invasive mechanical ventilation (IMV) for ≥72 h were included. Lung ultrasound was performed every day. Multivariate logistic regression analysis was used to evaluate factors that predict extubation outcomes. Results Ninety-three infants with GA ≤ 25+6 weeks were included. The mean GA was 24.5 ± 1.2 weeks. Extubation failure occurred in 55 (59.1%) neonates, and success occurred in 38 (40.9%) neonates. The LUS was significantly lower in the successful group than in the failed group (24.0 ± 2.5 vs. 32.1 ± 3.1 p < 0.001). Logistic regression analysis showed that LUS was an independent predictor of successful extubation (odd ratio 0.15 [95% CI 0.045–0.508], P = 0.002). The area under the receiver operating characteristic curve was 0.98 (p < 0.001) for LUS, and a cutoff value of ≥ 28 had 94.6% sensitivity and 92.7% specificity in detecting extubation failure. Conclusion The LUS has good accuracy for predicting successful extubation in extremely preterm infants with GA ≤ 25+6 weeks.
- 14 January 2025
- Published by Springer Nature in Journal of Perinatology
- Vol. 45 (6) , 830-836
Accuracy of lung ultrasound in predicting successful extubation in preterm infants born ≤ 25 weeks
Objective The aim of this study was to examine the predictive value of the lung ultrasound score (LUS) for successful extubation in preterm infants born at ≤25+6 weeks. Methods This was a single-center, prospective cohort study. Preterm infants with gestational age (GA) ≤ 25+6 weeks who received invasive mechanical ventilation (IMV) for ≥72 h were included. Lung ultrasound was performed every day. Multivariate logistic regression analysis was used to evaluate factors that predict extubation outcomes. Results Ninety-three infants with GA ≤ 25+6 weeks were included. The mean GA was 24.5 ± 1.2 weeks. Extubation failure occurred in 55 (59.1%) neonates, and success occurred in 38 (40.9%) neonates. The LUS was significantly lower in the successful group than in the failed group (24.0 ± 2.5 vs. 32.1 ± 3.1 p < 0.001). Logistic regression analysis showed that LUS was an independent predictor of successful extubation (odd ratio 0.15 [95% CI 0.045–0.508], P = 0.002). The area under the receiver operating characteristic curve was 0.98 (p < 0.001) for LUS, and a cutoff value of ≥ 28 had 94.6% sensitivity and 92.7% specificity in detecting extubation failure. Conclusion The LUS has good accuracy for predicting successful extubation in extremely preterm infants with GA ≤ 25+6 weeks.
- Open Access
- 3 September 2024
- Published by Wiley in Clinical Case Reports
- Vol. 12 (9) , e9341
Severe generalized edema in a premature neonate: A case report and literature review
Key Clinical Message: With no family history, and an atypical phenotype, the clinical diagnosing of Noonan syndrome (NS) can be very difficult. The present case emphasized that generalized edema in neonates may be the potential first symptom of NS. Severe generalized edema is a rare pathological condition with high mortality in newborns, in particular the premature infants. It is characterized by the extensive subcutaneous tissue edema and the accumulation of fluid in neonatal body fluid compartments. The etiology and pathogenesis of hydrops in neonates are quite complex. Generally speaking, hydrops can be divided into immune hydrops and non‐immune hydrops according to the etiology. It is still challenging in treating severe neonatal edema. In this study, we presented a preterm newborn with severe generalized edema after birth, which was finally diagnosed with Noonan syndrome (NS). The infant clinically manifested as severe generalized edema alone, without the involvement of multiple organ malformation. Generalized edema in neonates was probably the first symptom of NS. Therefore, differential diagnosis of NS is necessary for infants developing generalized edema.
- 3 September 2024
- Published by Wiley in Clinical Case Reports
- Vol. 12 (9) , e9341
Open AccessSevere generalized edema in a premature neonate: A case report and literature review
Key Clinical Message: With no family history, and an atypical phenotype, the clinical diagnosing of Noonan syndrome (NS) can be very difficult. The present case emphasized that generalized edema in neonates may be the potential first symptom of NS. Severe generalized edema is a rare pathological condition with high mortality in newborns, in particular the premature infants. It is characterized by the extensive subcutaneous tissue edema and the accumulation of fluid in neonatal body fluid compartments. The etiology and pathogenesis of hydrops in neonates are quite complex. Generally speaking, hydrops can be divided into immune hydrops and non‐immune hydrops according to the etiology. It is still challenging in treating severe neonatal edema. In this study, we presented a preterm newborn with severe generalized edema after birth, which was finally diagnosed with Noonan syndrome (NS). The infant clinically manifested as severe generalized edema alone, without the involvement of multiple organ malformation. Generalized edema in neonates was probably the first symptom of NS. Therefore, differential diagnosis of NS is necessary for infants developing generalized edema.
- 12 December 2023
- Published by Springer Nature in Journal of Perinatology
- Vol. 44 (2) , 273-279
Lung ultrasound score as a tool to predict severity of bronchopulmonary dysplasia in neonates born ≤25 weeks of gestational age
Objective The primary aim was to evaluate whether the addition of the posterior lung aided in diagnostic accuracy of predicting bronchopulmonary dysplasia (BPD) vs moderate-severe BPD (msBPD); the secondary aim was to explore the diagnostic accuracy of two protocols for BPD vs msBPD. Study design This was a single-center prospective observational study. Preterm infants with a gestational age ≤ 25 weeks were included. Two LUS score protocols were evaluated on the 14th day of life (DOL): (A) evaluating the anterolateral (LUS score-al) lung and (B) the anterolateral combined with posterior (LUS score-alp) lung. The LUS score range for the two protocols was 0–32 and 0–48, respectively. Results A total of eighty-nine infants were enrolled. Both the LUS score-al and LUS score-alp were higher in neonates developing BPD and msBPD than in the rest of the cohort (LUS score-al 24 (23,26) vs 22 (20,23); LUS score-alp 36 (34,39) vs 28 (25,32)) (LUS score-al 25 (24,26) vs 23 (21,24); LUS score-alp 40 (39,40) vs 34 (28,36)). The LUS score-al on the 14th DOL showed a moderate diagnostic accuracy to predict BPD and msBPD (AUC 95% CI: 0.797 [0.697–0.896]; 0.811[0.713–0.909]), while the LUS score-alp significantly improved diagnostic accuracy of BPD and msBPD (AUC 95% CI: 0.902 [0.834–0.970]; 0.922 [0.848–0.996]). A cutoff of 25 points in the LUS score-al provided a sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of 76.9%, 79.4%, 3.7, and 0.3 respectively to predict msBPD. Meanwhile, that of 39 points in the LUS score-alp provided a sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of 81%, 98.4%, 50.5 and 0.19 to predict msBPD, respectively. Conclusions The LUS score on the 14th DOL can predict BPD and msBPD with moderate diagnostic accuracy. Apart from that, scanning posterior enhanced diagnostic accuracy.
- 12 December 2023
- Published by Springer Nature in Journal of Perinatology
- Vol. 44 (2) , 273-279
Lung ultrasound score as a tool to predict severity of bronchopulmonary dysplasia in neonates born ≤25 weeks of gestational age
Objective The primary aim was to evaluate whether the addition of the posterior lung aided in diagnostic accuracy of predicting bronchopulmonary dysplasia (BPD) vs moderate-severe BPD (msBPD); the secondary aim was to explore the diagnostic accuracy of two protocols for BPD vs msBPD. Study design This was a single-center prospective observational study. Preterm infants with a gestational age ≤ 25 weeks were included. Two LUS score protocols were evaluated on the 14th day of life (DOL): (A) evaluating the anterolateral (LUS score-al) lung and (B) the anterolateral combined with posterior (LUS score-alp) lung. The LUS score range for the two protocols was 0–32 and 0–48, respectively. Results A total of eighty-nine infants were enrolled. Both the LUS score-al and LUS score-alp were higher in neonates developing BPD and msBPD than in the rest of the cohort (LUS score-al 24 (23,26) vs 22 (20,23); LUS score-alp 36 (34,39) vs 28 (25,32)) (LUS score-al 25 (24,26) vs 23 (21,24); LUS score-alp 40 (39,40) vs 34 (28,36)). The LUS score-al on the 14th DOL showed a moderate diagnostic accuracy to predict BPD and msBPD (AUC 95% CI: 0.797 [0.697–0.896]; 0.811[0.713–0.909]), while the LUS score-alp significantly improved diagnostic accuracy of BPD and msBPD (AUC 95% CI: 0.902 [0.834–0.970]; 0.922 [0.848–0.996]). A cutoff of 25 points in the LUS score-al provided a sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of 76.9%, 79.4%, 3.7, and 0.3 respectively to predict msBPD. Meanwhile, that of 39 points in the LUS score-alp provided a sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of 81%, 98.4%, 50.5 and 0.19 to predict msBPD, respectively. Conclusions The LUS score on the 14th DOL can predict BPD and msBPD with moderate diagnostic accuracy. Apart from that, scanning posterior enhanced diagnostic accuracy.
- 2 June 2023
- Published by Wiley in Pediatric Pulmonology
- Vol. 58 (9) , 2487-2494
Lung ultrasound score predicts patent ductus arteriosus ligation among neonates ≤25 weeks
Background: This prospective study aimed to investigate whether lung ultrasound score (LUSs) can predict the patent ductus arteriosus (PDA) ligation.Methods: Preterm infants ≤25 weeks of gestational age (GA) were enrolled. A lung ultrasound was performed on the 14th day of life. Each lung zone was given a score between 0 and 4. A receiver‐operating characteristic (ROC) curve was constructed to evaluate the ability of the LUSs for predicting ligation.Results: A total of 81 infants were eligible with a median GA and birth weight (BW) of 25 weeks (24.1–25.2) and 710 g (645–770), respectively. The median time from birth to ligation was 35 days (32–51). Those who underwent ligation had a longer time of mechanical ventilation (34 [26–39] vs. 19 [12–30], p < 0.001), shorter time of noninvasive respiratory support (39 [32–51] vs. 50 [41.5–57], p < 0.01), higher incidence of the bronchopulmonary dysplasia (BPD) (p < 0.01), and severe BPD (p < 0.001). The LUSs had an area under the ROC of 0.96 (95% confidence interval: 0.93–0.99) for the prediction of ligation. A LUSs cutoff of 36 has a sensitivity and specificity of 96% and 86% and positive and negative predictive values of 82% and 98%, respectively.Conclusions: LUSs at an early stage of life can predict PDA ligation in extremely preterm infants. It would be helpful to reduce morbidity by reducing the duration and magnitude of respiratory support.
- 2 June 2023
- Published by Wiley in Pediatric Pulmonology
- Vol. 58 (9) , 2487-2494
Lung ultrasound score predicts patent ductus arteriosus ligation among neonates ≤25 weeks
Background: This prospective study aimed to investigate whether lung ultrasound score (LUSs) can predict the patent ductus arteriosus (PDA) ligation.Methods: Preterm infants ≤25 weeks of gestational age (GA) were enrolled. A lung ultrasound was performed on the 14th day of life. Each lung zone was given a score between 0 and 4. A receiver‐operating characteristic (ROC) curve was constructed to evaluate the ability of the LUSs for predicting ligation.Results: A total of 81 infants were eligible with a median GA and birth weight (BW) of 25 weeks (24.1–25.2) and 710 g (645–770), respectively. The median time from birth to ligation was 35 days (32–51). Those who underwent ligation had a longer time of mechanical ventilation (34 [26–39] vs. 19 [12–30], p < 0.001), shorter time of noninvasive respiratory support (39 [32–51] vs. 50 [41.5–57], p < 0.01), higher incidence of the bronchopulmonary dysplasia (BPD) (p < 0.01), and severe BPD (p < 0.001). The LUSs had an area under the ROC of 0.96 (95% confidence interval: 0.93–0.99) for the prediction of ligation. A LUSs cutoff of 36 has a sensitivity and specificity of 96% and 86% and positive and negative predictive values of 82% and 98%, respectively.Conclusions: LUSs at an early stage of life can predict PDA ligation in extremely preterm infants. It would be helpful to reduce morbidity by reducing the duration and magnitude of respiratory support.
- 21 February 2021
- Published by Georg Thieme Verlag KG in American Journal of Perinatology
- Vol. 29 (14) , 1586-1595
Influence of Alveolar Fluid on Aquaporins and Na+/K+-ATPase and Its Possible Theoretical or Clinical Significance
Objective Pulmonary edema is the most common pathophysiological change in pulmonary disease. Aquaporins (AQPs) and Na+/K+-ATPase play pivotal roles in alveolar fluid clearance. This study aimed to explore the influence of increased alveolar fluid on the absorption of lung fluid. Study Design Eighty New Zealand rabbits were randomly divided into eight groups (n = 10 in each group), and models of different alveolar fluid contents were established by the infusion of different volumes of normal saline (NS) via the endotracheal tube. Five animals in each group were sacrificed immediately after infusion to determine the wet/dry ratio, while the remaining animals in each group were killed 4 hours later to determine the wet/dry ratio at 4 hours. Additionally, lung specimens were collected from each group, and quantitative real-time PCR (qRT-PCR), western blot, and immunohistochemical (IHC) analyses of AQPs and Na+/K+-ATPase were performed. Results The qRT-PCR analysis and western blot studies showed markedly decreased mRNA and protein levels of AQP1 and Na+/K+-ATPase when the alveolar fluid volume was ≥6 mL/kg, and the mRNA level of AQP5 was significantly reduced when the alveolar fluid volume was ≥4 mL/kg. In addition, IHC analysis showed the same results. At 4 hours, the lung wet/dry ratio was significantly increased when the alveolar fluid volume was ≥6 mL/kg; however, compared with 0 hours after NS infusion, there was still a significant absorption of alveolar fluid for a period of 4 hours. Conclusion The results of this study suggest that increased alveolar fluid may induce the downregulation of the mRNA and protein expression of AQPs and Na+/K+-ATPase, which appear to affect alveolar fluid clearance in rabbit lungs. Early intervention is required to avoid excessive alveolar fluid accumulation. Key Points J.L. participated in the study design and revised the draft manuscript. H.F.Z. and G.G. coordinated the study, participated in the study design, performed the ultrasound examinations, undertook the statistical analysis, and wrote the draft manuscript. C.Z.Y. and L.L.B. undertook the statistical analysis and wrote the draft manuscript. All authors read and approved the final manuscript. Received: 17 August 2020 Accepted: 14 January 2021 Article published online: 21 February 2021 © 2021. Thieme. All rights reserved. Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USA
- 21 February 2021
- Published by Georg Thieme Verlag KG in American Journal of Perinatology
- Vol. 29 (14) , 1586-1595
Influence of Alveolar Fluid on Aquaporins and Na+/K+-ATPase and Its Possible Theoretical or Clinical Significance
Objective Pulmonary edema is the most common pathophysiological change in pulmonary disease. Aquaporins (AQPs) and Na+/K+-ATPase play pivotal roles in alveolar fluid clearance. This study aimed to explore the influence of increased alveolar fluid on the absorption of lung fluid. Study Design Eighty New Zealand rabbits were randomly divided into eight groups (n = 10 in each group), and models of different alveolar fluid contents were established by the infusion of different volumes of normal saline (NS) via the endotracheal tube. Five animals in each group were sacrificed immediately after infusion to determine the wet/dry ratio, while the remaining animals in each group were killed 4 hours later to determine the wet/dry ratio at 4 hours. Additionally, lung specimens were collected from each group, and quantitative real-time PCR (qRT-PCR), western blot, and immunohistochemical (IHC) analyses of AQPs and Na+/K+-ATPase were performed. Results The qRT-PCR analysis and western blot studies showed markedly decreased mRNA and protein levels of AQP1 and Na+/K+-ATPase when the alveolar fluid volume was ≥6 mL/kg, and the mRNA level of AQP5 was significantly reduced when the alveolar fluid volume was ≥4 mL/kg. In addition, IHC analysis showed the same results. At 4 hours, the lung wet/dry ratio was significantly increased when the alveolar fluid volume was ≥6 mL/kg; however, compared with 0 hours after NS infusion, there was still a significant absorption of alveolar fluid for a period of 4 hours. Conclusion The results of this study suggest that increased alveolar fluid may induce the downregulation of the mRNA and protein expression of AQPs and Na+/K+-ATPase, which appear to affect alveolar fluid clearance in rabbit lungs. Early intervention is required to avoid excessive alveolar fluid accumulation. Key Points J.L. participated in the study design and revised the draft manuscript. H.F.Z. and G.G. coordinated the study, participated in the study design, performed the ultrasound examinations, undertook the statistical analysis, and wrote the draft manuscript. C.Z.Y. and L.L.B. undertook the statistical analysis and wrote the draft manuscript. All authors read and approved the final manuscript. Received: 17 August 2020 Accepted: 14 January 2021 Article published online: 21 February 2021 © 2021. Thieme. All rights reserved. Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USA
- 17 November 2020
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 34 (13) , 2197-2205
Wet lung leading to RDS: the lung ultrasound findings and possible mechanisms - a pilot study from an animal mode
Clinically, the lung ultrasound (LUS) showed wet lung could cause respiratory distress syndrome (RDS) in newborns. This work aimed to investigate LUS changes over time and its potential mechanism a...
- 17 November 2020
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 34 (13) , 2197-2205
Wet lung leading to RDS: the lung ultrasound findings and possible mechanisms - a pilot study from an animal mode
Clinically, the lung ultrasound (LUS) showed wet lung could cause respiratory distress syndrome (RDS) in newborns. This work aimed to investigate LUS changes over time and its potential mechanism a...