Junsong Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Junsong Liu has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
Chongwen Xu
Department of Otorhinolaryngology-Head and Neck Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, Shaanxi Province, China
5 shared publicationsHonghui Li
Department of Otorhinolaryngology-Head and Neck Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, Shaanxi Province, China
5 shared publicationsRuimin Zhao
Department of Otorhinolaryngology-Head and Neck Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, Shaanxi Province, China
5 shared publicationsLin Fan
Department of General Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, Shaanxi Province, 710061, China
4 shared publicationsRui Wang
Department of Anesthesiology, The First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, Shaanxi, 710061, People's Republic of China
4 shared publicationsShaoqiang Zhang
Department of Otorhinolaryngology-Head and Neck Surgery, 277 West Yanta Road, Xi'an, Shaanxi, 710061, People's Republic of China
4 shared publications
Latest Publications
- 16 September 2025
- Published by Elsevier in Molecules and Cells
- Vol. 48 (10) , 100266
Corrigendum to “SKP2 contributes to AKT activation by ubiquitination degradation of PHLPP1, impedes autophagy, and facilitates the survival of thyroid carcinoma” [Molecules and Cells Volume 46, Issue 6, June 2023, 360-373]
- 16 September 2025
- Published by Elsevier in Molecules and Cells
- Vol. 48 (10) , 100266
Corrigendum to “SKP2 contributes to AKT activation by ubiquitination degradation of PHLPP1, impedes autophagy, and facilitates the survival of thyroid carcinoma” [Molecules and Cells Volume 46, Issue 6, June 2023, 360-373]
- 13 June 2024
- Published by Elsevier in Journal of Energy Storage
- Vol. 94, 112446
CoNi2S4/Co9S8 nanorods as advanced electrode material for supercapacitors
- 13 June 2024
- Published by Elsevier in Journal of Energy Storage
- Vol. 94, 112446
CoNi2S4/Co9S8 nanorods as advanced electrode material for supercapacitors
- Open Access
- 25 January 2023
- Published by Elsevier in Molecules and Cells
- Vol. 46 (6) , 360-373
SKP2 Contributes to AKT Activation by Ubiquitination Degradation of PHLPP1, Impedes Autophagy, and Facilitates the Survival of Thyroid Carcinoma
Yuan Shao, Wanli Ren, Hao Dai, Fangli Yang, Xiang Li, Shaoqiang Zhang, Junsong Liu, Xiaobao Yao, Qian Zhao, Xin Sun, Zhiwei Zheng, and Chongwen Xu. Mol. Cells -0001;0:. https://doi.org/10.14348/molcells.2022.2242
- 25 January 2023
- Published by Elsevier in Molecules and Cells
- Vol. 46 (6) , 360-373
Open AccessSKP2 Contributes to AKT Activation by Ubiquitination Degradation of PHLPP1, Impedes Autophagy, and Facilitates the Survival of Thyroid Carcinoma
Yuan Shao, Wanli Ren, Hao Dai, Fangli Yang, Xiang Li, Shaoqiang Zhang, Junsong Liu, Xiaobao Yao, Qian Zhao, Xin Sun, Zhiwei Zheng, and Chongwen Xu. Mol. Cells -0001;0:. https://doi.org/10.14348/molcells.2022.2242
- Open Access
- 6 January 2020
- Published by Springer Nature in BMC Surgery
- Vol. 20 (1) , 1-7
Near-infrared auto-fluorescence spectroscopy combining with Fisher’s linear discriminant analysis improves intraoperative real-time identification of normal parathyroid in thyroidectomy
Background: To evaluate the efficacy of a sensitive, real-time tool for identification and protection for parathyroid glands during thyroidectomy. Methods: Near-infrared (NIR) auto-fluorescence was measured intraoperatively from 20 patients undergoing thyroidectomy. Spectra were measured from suspicious parathyroid glands and surrounding neck tissues during the operation with a NIR fluorescence system. Fast frozen sections were performed on the suspicious parathyroid glands. Accuracy was evaluated by comparison with histology and NIR identification. Data were attracted for Fisher’s linear discriminant analysis. Results: The auto-fluorescence intensity of parathyroid was significantly higher than that of thyroid, fat and lymph node. The peak intensity of auto-fluorescence from parathyroid was 5.55 times of that from thyroid at the corresponding wave number. Of the 20 patients, the parathyroid was accurately detected and identified in 19 patients by NIR system, compared with their histologic results. One suspicious parathyroid did not exhibit typical spectra, and was proved to be fat tissue by histology. The NIR auto-fluorescence method had a 100% sensitivity of parathyroid glands identification and a high accuracy of 95%. The positive predictive value was 95%. The parathyroid gland have specific auto-fluorescence spectrum and can be separated from the other three samples through the Fisher’s linear discriminant analysis. Conclusions: NIR auto-fluorescence spectroscopy can accurately identify normal parathyroid gland during thyroidectomy. The Fisher’s linear discriminant analysis demonstrated the specificity of the NIR auto-fluorescence of parathyroid tissue and its efficacy in parathyroid discrimination.
- 6 January 2020
- Published by Springer Nature in BMC Surgery
- Vol. 20 (1) , 1-7
Open AccessNear-infrared auto-fluorescence spectroscopy combining with Fisher’s linear discriminant analysis improves intraoperative real-time identification of normal parathyroid in thyroidectomy
Background: To evaluate the efficacy of a sensitive, real-time tool for identification and protection for parathyroid glands during thyroidectomy. Methods: Near-infrared (NIR) auto-fluorescence was measured intraoperatively from 20 patients undergoing thyroidectomy. Spectra were measured from suspicious parathyroid glands and surrounding neck tissues during the operation with a NIR fluorescence system. Fast frozen sections were performed on the suspicious parathyroid glands. Accuracy was evaluated by comparison with histology and NIR identification. Data were attracted for Fisher’s linear discriminant analysis. Results: The auto-fluorescence intensity of parathyroid was significantly higher than that of thyroid, fat and lymph node. The peak intensity of auto-fluorescence from parathyroid was 5.55 times of that from thyroid at the corresponding wave number. Of the 20 patients, the parathyroid was accurately detected and identified in 19 patients by NIR system, compared with their histologic results. One suspicious parathyroid did not exhibit typical spectra, and was proved to be fat tissue by histology. The NIR auto-fluorescence method had a 100% sensitivity of parathyroid glands identification and a high accuracy of 95%. The positive predictive value was 95%. The parathyroid gland have specific auto-fluorescence spectrum and can be separated from the other three samples through the Fisher’s linear discriminant analysis. Conclusions: NIR auto-fluorescence spectroscopy can accurately identify normal parathyroid gland during thyroidectomy. The Fisher’s linear discriminant analysis demonstrated the specificity of the NIR auto-fluorescence of parathyroid tissue and its efficacy in parathyroid discrimination.
- Open Access
- 27 December 2019
- Published by Springer Nature in Research Square
Near-infrared auto-fluorescence spectroscopy combining with Fisher’s linear discriminant analysis improves intraoperative real-time identification of normal parathyroid in thyroidectomy
Background To evaluate the efficacy of a sensitive, real-time tool for identification and protection of parathyroid glands during thyroidectomy. Methods Near-infrared (NIR) auto-fluorescence was measured intraoperatively from 20 patients undergoing thyroidectomy. To determine the accuracy of NIR identification furtherly, intraoperative fast frozen pathological examination and postoperative immunohistochemical staining were performed on the suspicious parathyroid glands and other neck tissues. Data were extracted for Fisher’s linear discriminant analysis. Results The auto-fluorescence intensity of parathyroid was significantly higher than that of thyroid, fat and lymph node. The peak intensity of auto-fluorescence from parathyroid was 5.55 times as much as that from thyroid at the corresponding wave number. Of the 20 patients, the parathyroid was accurately detected and identified in 19 patients by NIR system, compared with their histopathological results. One suspicious parathyroid tissue did not exhibit characteristic spectra, and finally was proved to be fat tissue by histopathological examination. The NIR auto-fluorescence method had a 100% (19/19) sensitivity of parathyroid glands identification and a high accuracy of 95% (19/20). The positive predictive value was 95%. The parathyroid gland has specific auto-fluorescence spectrum and can be separated from the other three types of tissues through the Fisher’s linear discriminant analysis with the average accuracy rate around 90%. Conclusions NIR auto-fluorescence spectoscopy can accurately identify normal parathyroid glands during thyroidectomy. The Fisher’s linear discriminant analysis demonstrated the specificity of the NIR auto-fluorescence of parathyroid tissue and its efficacy in parathyroid discrimination.
- 27 December 2019
- Published by Springer Nature in Research Square
Open AccessNear-infrared auto-fluorescence spectroscopy combining with Fisher’s linear discriminant analysis improves intraoperative real-time identification of normal parathyroid in thyroidectomy
Background To evaluate the efficacy of a sensitive, real-time tool for identification and protection of parathyroid glands during thyroidectomy. Methods Near-infrared (NIR) auto-fluorescence was measured intraoperatively from 20 patients undergoing thyroidectomy. To determine the accuracy of NIR identification furtherly, intraoperative fast frozen pathological examination and postoperative immunohistochemical staining were performed on the suspicious parathyroid glands and other neck tissues. Data were extracted for Fisher’s linear discriminant analysis. Results The auto-fluorescence intensity of parathyroid was significantly higher than that of thyroid, fat and lymph node. The peak intensity of auto-fluorescence from parathyroid was 5.55 times as much as that from thyroid at the corresponding wave number. Of the 20 patients, the parathyroid was accurately detected and identified in 19 patients by NIR system, compared with their histopathological results. One suspicious parathyroid tissue did not exhibit characteristic spectra, and finally was proved to be fat tissue by histopathological examination. The NIR auto-fluorescence method had a 100% (19/19) sensitivity of parathyroid glands identification and a high accuracy of 95% (19/20). The positive predictive value was 95%. The parathyroid gland has specific auto-fluorescence spectrum and can be separated from the other three types of tissues through the Fisher’s linear discriminant analysis with the average accuracy rate around 90%. Conclusions NIR auto-fluorescence spectoscopy can accurately identify normal parathyroid glands during thyroidectomy. The Fisher’s linear discriminant analysis demonstrated the specificity of the NIR auto-fluorescence of parathyroid tissue and its efficacy in parathyroid discrimination.
- Open Access
- 5 November 2019
- Published by Springer Nature in Research Square
Near-infrared auto-fluorescence spectroscopy combining with Fisher’s linear discriminant analysis improves intraoperative real-time identification of normal parathyroid in thyroidectomy
Background To evaluate the efficacy of a sensitive, real-time tool for identification and protection of parathyroid glands during thyroidectomy. Methods Near-infrared (NIR) auto-fluorescence was measured intraoperatively from 20 patients undergoing thyroidectomy. To determine the accuracy of NIR identification furtherly, intraoperative fast frozen pathological examination and postoperative immunohistochemical staining were performed on the suspicious parathyroid glands and other neck tissues. Data were extracted for Fisher’s linear discriminant analysis. Results The auto-fluorescence intensity of parathyroid was significantly higher than that of thyroid, fat and lymph node. The peak intensity of auto-fluorescence from parathyroid was 5.55 times as much as that from thyroid at the corresponding wave number. Of the 20 patients, the parathyroid was accurately detected and identified in 19 patients by NIR system, compared with their histopathological results. One suspicious parathyroid tissue did not exhibit characteristic spectra, and finally was proved to be fat tissue by histopathological examination. The NIR auto-fluorescence method had a 100% (19/19) sensitivity of parathyroid glands identification and a high accuracy of 95% (19/20). The positive predictive value was 95%. The parathyroid gland has specific auto-fluorescence spectrum and can be separated from the other three types of tissues through the Fisher’s linear discriminant analysis with the average accuracy rate around 90%.Conclusions NIR auto-fluorescence spectoscopy can accurately identify normal parathyroid glands during thyroidectomy. The Fisher’s linear discriminant analysis demonstrated the specificity of the NIR auto-fluorescence of parathyroid tissue and its efficacy in parathyroid discrimination.
- 5 November 2019
- Published by Springer Nature in Research Square
Open AccessNear-infrared auto-fluorescence spectroscopy combining with Fisher’s linear discriminant analysis improves intraoperative real-time identification of normal parathyroid in thyroidectomy
Background To evaluate the efficacy of a sensitive, real-time tool for identification and protection of parathyroid glands during thyroidectomy. Methods Near-infrared (NIR) auto-fluorescence was measured intraoperatively from 20 patients undergoing thyroidectomy. To determine the accuracy of NIR identification furtherly, intraoperative fast frozen pathological examination and postoperative immunohistochemical staining were performed on the suspicious parathyroid glands and other neck tissues. Data were extracted for Fisher’s linear discriminant analysis. Results The auto-fluorescence intensity of parathyroid was significantly higher than that of thyroid, fat and lymph node. The peak intensity of auto-fluorescence from parathyroid was 5.55 times as much as that from thyroid at the corresponding wave number. Of the 20 patients, the parathyroid was accurately detected and identified in 19 patients by NIR system, compared with their histopathological results. One suspicious parathyroid tissue did not exhibit characteristic spectra, and finally was proved to be fat tissue by histopathological examination. The NIR auto-fluorescence method had a 100% (19/19) sensitivity of parathyroid glands identification and a high accuracy of 95% (19/20). The positive predictive value was 95%. The parathyroid gland has specific auto-fluorescence spectrum and can be separated from the other three types of tissues through the Fisher’s linear discriminant analysis with the average accuracy rate around 90%.Conclusions NIR auto-fluorescence spectoscopy can accurately identify normal parathyroid glands during thyroidectomy. The Fisher’s linear discriminant analysis demonstrated the specificity of the NIR auto-fluorescence of parathyroid tissue and its efficacy in parathyroid discrimination.
- Open Access
- 7 September 2019
- Published by Springer Nature in Research Square
Near-infrared auto-fluorescence spectroscopy combining with Fisher’s linear discriminant analysis improves intraoperative real-time identification of normal parathyroid in thyroidectomy
Background To evaluate the efficacy of a sensitive, real-time tool for identification and protection for parathyroid glands during thyroidectomy.Methods NIR fluorescence was measured intraoperatively from 20 patients undergoing thyroidectomy. Spectra were measured from suspicious parathyroid glands and surrounding neck tissues during the operation with a NIR fluorescence system. Fast frozen sections were performed on the suspicious parathyroid glands. Accuracy was evaluated by comparison with histology or NIR recognition. Data were attracted for Fisher’s linear discriminant analysis.Results The auto-fluorescence intensity of parathyroid was significantly higher than that of thyroid, fat and lymph node. The peak intensity of auto-fluorescence from parathyroid was 5.55 times of that from thyroid at the corresponding wave number. Of the 20 patients, the parathyroid was accurately detected and identified in 19 patients by NIR system, compared with their pathologic findings. One suspicious parathyroid did not exhibit typical spectra, and was proved to be fat tissue by pathology. The parathyroid gland have specific auto-fluorescence spectrum and can be separated from the other three samples through the Fisher’s linear discriminant analysis.Conclusions NIR auto-fluorescence spectroscopy can accurately identify normal parathyroid gland during thyroidectomy. The Fisher’s linear discriminant analysis demonstrated the specificity of the NIR auto-fluorescence of parathyroid tissue and its efficacy in parathyroid discrimination.
- 7 September 2019
- Published by Springer Nature in Research Square
Open AccessNear-infrared auto-fluorescence spectroscopy combining with Fisher’s linear discriminant analysis improves intraoperative real-time identification of normal parathyroid in thyroidectomy
Background To evaluate the efficacy of a sensitive, real-time tool for identification and protection for parathyroid glands during thyroidectomy.Methods NIR fluorescence was measured intraoperatively from 20 patients undergoing thyroidectomy. Spectra were measured from suspicious parathyroid glands and surrounding neck tissues during the operation with a NIR fluorescence system. Fast frozen sections were performed on the suspicious parathyroid glands. Accuracy was evaluated by comparison with histology or NIR recognition. Data were attracted for Fisher’s linear discriminant analysis.Results The auto-fluorescence intensity of parathyroid was significantly higher than that of thyroid, fat and lymph node. The peak intensity of auto-fluorescence from parathyroid was 5.55 times of that from thyroid at the corresponding wave number. Of the 20 patients, the parathyroid was accurately detected and identified in 19 patients by NIR system, compared with their pathologic findings. One suspicious parathyroid did not exhibit typical spectra, and was proved to be fat tissue by pathology. The parathyroid gland have specific auto-fluorescence spectrum and can be separated from the other three samples through the Fisher’s linear discriminant analysis.Conclusions NIR auto-fluorescence spectroscopy can accurately identify normal parathyroid gland during thyroidectomy. The Fisher’s linear discriminant analysis demonstrated the specificity of the NIR auto-fluorescence of parathyroid tissue and its efficacy in parathyroid discrimination.
- 24 May 2016
- Published by Springer Nature in Tumor Biology
- Vol. 37 (9) , 12141-12151
MicroRNA-125b promotes invasion and metastasis of gastric cancer by targeting STARD13 and NEU1
MicroRNAs have been documented playing key roles in cancer development and progression. Here, we investigate the role of miR-125b in gastric cancer metastasis. We found that the expression of miR-125b was up-regulated in gastric cancer tissue specimens compared with their corresponding nontumorous tissues, and the up-regulated miR-125b level was significantly associated with TNM stage and lymph node-metastasis. Overexpression of miR-125b promoted gastric cancer cell migration and invasion in vitro and metastasis in vivo. STARD13 and NEU1 were identified as direct target genes of miR-125b by luciferase assays, and they were involved in the cell migration and invasion regulated by miR-125b in gastric cancer. Taken together, miR-125b functions as an oncogene in gastric cancer and represents a new potential therapeutic target for gastric cancer.
- 24 May 2016
- Published by Springer Nature in Tumor Biology
- Vol. 37 (9) , 12141-12151
MicroRNA-125b promotes invasion and metastasis of gastric cancer by targeting STARD13 and NEU1
MicroRNAs have been documented playing key roles in cancer development and progression. Here, we investigate the role of miR-125b in gastric cancer metastasis. We found that the expression of miR-125b was up-regulated in gastric cancer tissue specimens compared with their corresponding nontumorous tissues, and the up-regulated miR-125b level was significantly associated with TNM stage and lymph node-metastasis. Overexpression of miR-125b promoted gastric cancer cell migration and invasion in vitro and metastasis in vivo. STARD13 and NEU1 were identified as direct target genes of miR-125b by luciferase assays, and they were involved in the cell migration and invasion regulated by miR-125b in gastric cancer. Taken together, miR-125b functions as an oncogene in gastric cancer and represents a new potential therapeutic target for gastric cancer.
- 13 April 2016
- Published by Spandidos Publications in Oncology Reports
- Vol. 35 (6) , 3577-3585
HOTTIP and HOXA13 are oncogenes associated with gastric cancer progression
Spandidos Publications is a scientific publisher with a long-standing international reputation for excellent standards and high quality science publications
- 13 April 2016
- Published by Spandidos Publications in Oncology Reports
- Vol. 35 (6) , 3577-3585
HOTTIP and HOXA13 are oncogenes associated with gastric cancer progression
Spandidos Publications is a scientific publisher with a long-standing international reputation for excellent standards and high quality science publications