Nicolino Stasio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nicolino Stasio has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Demetri Psaltis
Optics Laboratory (LO), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
7 shared publications Christophe Moser
Laboratory of Applied Photonic Devices, École Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland
4 shared publications- Emmanuel Bossy
Univ. Grenoble Alpes, CNRS, LIPhy, 38000 Grenoble, France
3 shared publications - Augusto Nascetti
School of Aerospace Engineering, Sapienza University of Rome, Via Salaria 851, 00138 Rome, Italy
2 shared publications - Christophe Moser
Ecole Polytechnique Federale de Lausanne (Switzerland)
2 shared publications - Domenico Caputo
Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, Via Eudossiana 18, 00184 Rome, Italy
2 shared publications
Latest Publications
- 7 September 2017
- Published by SPIE-Intl Soc Optical Eng
Femtosecond pulse delivery through multi-core fibers for imaging and ablation
- 7 September 2017
- Published by SPIE-Intl Soc Optical Eng
Femtosecond pulse delivery through multi-core fibers for imaging and ablation
- 3 March 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 100641O-100641O-5
Multiple speckle illumination for optical-resolution photoacoustic imaging
- 3 March 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 100641O-100641O-5
Multiple speckle illumination for optical-resolution photoacoustic imaging
- Open Access
- 13 November 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23 (23) , 30532-30544
Light control in a multicore fiber using the memory effect
Endoscopic imaging through a multicore fiber (MCF) is widely used but is affected by pixelated images, which limits its resolution to a few micrometers. This is due to the spacing between the cores in the MCF, which is large enough to avoid core-to-core light coupling. Wavefront shaping techniques have been shown to focus light to a resolution finer than the inter core spacing, however a long calibration procedure is needed. Moreover the calibration depends on the optical fiber conformation. Here, we show a calibration method using only one digital hologram. The method is based on digital phase conjugation and the memory effect of the MCF to focus and scan a spot. In addition, we show how simple patterns can be projected using the same multicore fiber.
- 13 November 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23 (23) , 30532-30544
Open AccessLight control in a multicore fiber using the memory effect
Endoscopic imaging through a multicore fiber (MCF) is widely used but is affected by pixelated images, which limits its resolution to a few micrometers. This is due to the spacing between the cores in the MCF, which is large enough to avoid core-to-core light coupling. Wavefront shaping techniques have been shown to focus light to a resolution finer than the inter core spacing, however a long calibration procedure is needed. Moreover the calibration depends on the optical fiber conformation. Here, we show a calibration method using only one digital hologram. The method is based on digital phase conjugation and the memory effect of the MCF to focus and scan a spot. In addition, we show how simple patterns can be projected using the same multicore fiber.
- Open Access
- 2 November 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (12) , 4619-4631
Towards new applications using capillary waveguides
In this paper we demonstrate the enhancement of the sensing capabilities of glass capillaries. We exploit their properties as optical and acoustic waveguides to transform them potentially into high resolution minimally invasive endoscopic devices. We show two possible applications of silica capillary waveguides demonstrating fluorescence and optical-resolution photoacoustic imaging using a single 330 μm-thick silica capillary. A nanosecond pulsed laser is focused and scanned in front of a capillary by digital phase conjugation through the silica annular ring of the capillary, used as an optical waveguide. We demonstrate optical-resolution photoacoustic images of a 30 μm-thick nylon thread using the water-filled core of the same capillary as an acoustic waveguide, resulting in a fully passive endoscopic device. Moreover, fluorescence images of 1.5 μm beads are obtained collecting the fluorescence signal through the optical waveguide. This kind of silica-capillary waveguide together with wavefront shaping techniques such as digital phase conjugation, paves the way to minimally invasive multi-modal endoscopy.
- 2 November 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (12) , 4619-4631
Open AccessTowards new applications using capillary waveguides
In this paper we demonstrate the enhancement of the sensing capabilities of glass capillaries. We exploit their properties as optical and acoustic waveguides to transform them potentially into high resolution minimally invasive endoscopic devices. We show two possible applications of silica capillary waveguides demonstrating fluorescence and optical-resolution photoacoustic imaging using a single 330 μm-thick silica capillary. A nanosecond pulsed laser is focused and scanned in front of a capillary by digital phase conjugation through the silica annular ring of the capillary, used as an optical waveguide. We demonstrate optical-resolution photoacoustic images of a 30 μm-thick nylon thread using the water-filled core of the same capillary as an acoustic waveguide, resulting in a fully passive endoscopic device. Moreover, fluorescence images of 1.5 μm beads are obtained collecting the fluorescence signal through the optical waveguide. This kind of silica-capillary waveguide together with wavefront shaping techniques such as digital phase conjugation, paves the way to minimally invasive multi-modal endoscopy.
- Open Access
- 9 October 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23 (21) , 27484-27493
Enhanced resolution in a multimode fiber imaging system
Multimode fibers have recently been demonstrated to be a promising candidate for ultrathin and high resolution endoscopy. However, this method does not offer depth discrimination for fluorescence imaging and the numerical aperture of the fiber limits its resolution. In this paper we demonstrate optical sectioning and enhanced resolution using saturated excitation and temporal modulation. Using a continuous wave laser excitation, we demonstrate improved resolution in all three dimensions and increased image contrast by rejecting out of focus light.
- 9 October 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23 (21) , 27484-27493
Open AccessEnhanced resolution in a multimode fiber imaging system
Multimode fibers have recently been demonstrated to be a promising candidate for ultrathin and high resolution endoscopy. However, this method does not offer depth discrimination for fluorescence imaging and the numerical aperture of the fiber limits its resolution. In this paper we demonstrate optical sectioning and enhanced resolution using saturated excitation and temporal modulation. Using a continuous wave laser excitation, we demonstrate improved resolution in all three dimensions and increased image contrast by rejecting out of focus light.
- 2 March 2015
- Published by AIP Publishing in Applied Physics Letters
- Vol. 106 (9) , 094102
Optical-resolution photoacoustic imaging through thick tissue with a thin capillary as a dual optical-in acoustic-out waveguide
We demonstrate the ability to guide high-frequency photoacoustic waves through thick tissue with a water-filled silica-capillary (150 μm inner diameter and 30 mm long). An optical-resolution photoacoustic image of a 30 μm diameter absorbing nylon thread was obtained by guiding the acoustic waves in the capillary through a 3 cm thick fat layer. The transmission loss through the capillary was about −20 dB, much lower than the −120 dB acoustic attenuation through the fat layer. The overwhelming acoustic attenuation of high-frequency acoustic waves by biological tissue can therefore be avoided by the use of a small footprint capillary acoustic waveguide for remote detection. We finally demonstrate that the capillary can be used as a dual optical-in acoustic-out waveguide, paving the way for the development of minimally invasive optical-resolution photoacoustic endoscopes free of any acoustic or optical elements at their imaging tip.
- 2 March 2015
- Published by AIP Publishing in Applied Physics Letters
- Vol. 106 (9) , 094102
Optical-resolution photoacoustic imaging through thick tissue with a thin capillary as a dual optical-in acoustic-out waveguide
We demonstrate the ability to guide high-frequency photoacoustic waves through thick tissue with a water-filled silica-capillary (150 μm inner diameter and 30 mm long). An optical-resolution photoacoustic image of a 30 μm diameter absorbing nylon thread was obtained by guiding the acoustic waves in the capillary through a 3 cm thick fat layer. The transmission loss through the capillary was about −20 dB, much lower than the −120 dB acoustic attenuation through the fat layer. The overwhelming acoustic attenuation of high-frequency acoustic waves by biological tissue can therefore be avoided by the use of a small footprint capillary acoustic waveguide for remote detection. We finally demonstrate that the capillary can be used as a dual optical-in acoustic-out waveguide, paving the way for the development of minimally invasive optical-resolution photoacoustic endoscopes free of any acoustic or optical elements at their imaging tip.
- 19 December 2014
- Published by Optica Publishing Group in Optica
- Vol. 1 (6) , 455-460
Resolution enhancement in nonlinear scanning microscopy through post-detection digital computation
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 19 December 2014
- Published by Optica Publishing Group in Optica
- Vol. 1 (6) , 455-460
Resolution enhancement in nonlinear scanning microscopy through post-detection digital computation
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 25 October 2013
- Published by Springer Nature
- p. 23-27
Thermally Actuated Microfluidic System for Polymerase Chain Reaction Applications
- 25 October 2013
- Published by Springer Nature
- p. 23-27
Thermally Actuated Microfluidic System for Polymerase Chain Reaction Applications
- 25 October 2013
- Published by Springer Nature
- p. 183-187
On-Chip Diagnosis of Celiac Disease by an Amorphous Silicon Chemiluminescence Detector
- 25 October 2013
- Published by Springer Nature
- p. 183-187
On-Chip Diagnosis of Celiac Disease by an Amorphous Silicon Chemiluminescence Detector
- 1 June 2013
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 110 (3) , 333-342
Optimal control for SIRC epidemic outbreak
- 1 June 2013
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 110 (3) , 333-342
Optimal control for SIRC epidemic outbreak