Rafał BIAŁEK
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rafał BIAŁEK has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Kamila Jadczak
1 Military University of Technology, Wojskowa Akademia Techniczna, 01-476 Warszawa, Poland
4 shared publicationsMarek Kuchta
Military Univ. of Technology (Poland)
3 shared publications- Kamila Białek
Faculty of Electronics, Military University of Technology, 00-908 Warsaw, Poland
2 shared publications - Dariusz Laskowski
Faculty of Electronics, Military University of Technology, 00-908 Warsaw, Poland
1 shared publication - Jacek Jakubowski
Faculty of Electronics, Military University of Technology, 00-908 Warsaw, Poland
1 shared publication Jacek Paś
1 Military University of Technology, Wojskowa Akademia Techniczna, 01-476 Warszawa, Poland
1 shared publication
Latest Publications
- Open Access
A Quasi-Isotropic Probe for High-Power Microwave Field Measurement
In the paper, a new design of a quasi-isotropic antenna for high-power electromagnetic (EM) field measurement is presented, along with its investigation into suitability. The measuring probe is intended for assessing pulsed microwaves, which cannot be measured by available meters due to the high value of electric field strength and short pulse duration. The measurement of such a strong field is required according to guidelines for protecting people against microwave fields, especially those emitted by radars. The proposed probe is based on the concept of dipole–diode detection. To enable high-power measurement, the receiving antenna is electrically “small,” allowing diode detection within the diode square-law characteristics range. Additionally, the shortened dipole length minimizes the spatial integration error, which can be significant in the case of microwave measurement. To obtain the desired antenna polarization, a new dipole geometry was proposed. Fulfilling the requirement of measuring all incident EM field polarizations, the receiving antenna was based on three dipoles arranged within a specific “magic” angular arrangement, ensuring a suitable quasi-isotropic radiation pattern. The proposed probe can operate in a frequency range from 1 GHz to 12 GHz.
Open AccessA Quasi-Isotropic Probe for High-Power Microwave Field Measurement
In the paper, a new design of a quasi-isotropic antenna for high-power electromagnetic (EM) field measurement is presented, along with its investigation into suitability. The measuring probe is intended for assessing pulsed microwaves, which cannot be measured by available meters due to the high value of electric field strength and short pulse duration. The measurement of such a strong field is required according to guidelines for protecting people against microwave fields, especially those emitted by radars. The proposed probe is based on the concept of dipole–diode detection. To enable high-power measurement, the receiving antenna is electrically “small,” allowing diode detection within the diode square-law characteristics range. Additionally, the shortened dipole length minimizes the spatial integration error, which can be significant in the case of microwave measurement. To obtain the desired antenna polarization, a new dipole geometry was proposed. Fulfilling the requirement of measuring all incident EM field polarizations, the receiving antenna was based on three dipoles arranged within a specific “magic” angular arrangement, ensuring a suitable quasi-isotropic radiation pattern. The proposed probe can operate in a frequency range from 1 GHz to 12 GHz.
- 19 March 2024
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (3) , 277-279
Parametrization of handwriting for the assessment of neurodegenerative disorders on the example of Parkinson’s disease
The following paper will present the methodology of determining handwriting parameters, the assessment of which can be used in the diagnosis of Parkinson's disease. The proposed parameters were determined on the basis of the recording of the entire sentence recorded using a graphic electromagnetic tablet
- 19 March 2024
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (3) , 277-279
Parametrization of handwriting for the assessment of neurodegenerative disorders on the example of Parkinson’s disease
The following paper will present the methodology of determining handwriting parameters, the assessment of which can be used in the diagnosis of Parkinson's disease. The proposed parameters were determined on the basis of the recording of the entire sentence recorded using a graphic electromagnetic tablet
- Open Access
Three Dimensional Membrane Vibration Measurement Using a Two Dimensional Position Sensitive Device
This study presents the outcome of research into membrane vibrations in a 3D space performed using a system based on position sensitive device (PSD) sensors. Here, measurements were conducted for harmonic vibrations. The use of such detectors for assessing the movement of objects within a plane or space requires determining the position of more than one marker. The article reviews two methods for detecting the position of several light spots on a sensor’s photosensitive plane: a marker sequential control method, and a method based on Fast Fourier Transform (FFT) that employs a square wave control signal. The authors present an approach to improving measurement accuracy for both methods. They also discuss the advantages and disadvantages of each.
Open AccessThree Dimensional Membrane Vibration Measurement Using a Two Dimensional Position Sensitive Device
This study presents the outcome of research into membrane vibrations in a 3D space performed using a system based on position sensitive device (PSD) sensors. Here, measurements were conducted for harmonic vibrations. The use of such detectors for assessing the movement of objects within a plane or space requires determining the position of more than one marker. The article reviews two methods for detecting the position of several light spots on a sensor’s photosensitive plane: a marker sequential control method, and a method based on Fast Fourier Transform (FFT) that employs a square wave control signal. The authors present an approach to improving measurement accuracy for both methods. They also discuss the advantages and disadvantages of each.
- 9 December 2022
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (12) , 223-226
Stanowisko laboratoryjne do automatycznego pomiaru wybranych charakterystyk przetwornic DC/DC oraz liniowych stabilizatorów napięcia
W pracy przedstawiono stanowisko laboratoryjne do badania przetwornic DC/DC. Podstawowymi elementami stanowiska są komputer z autorskim oprogramowaniem oraz przyrządy programowalne. W artykule przedstawiono możliwości wykonanego oprogramowania oraz wyniki badań przykładowych układów przetwarzających napięcie: impulsowego i liniowego.
- 9 December 2022
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (12) , 223-226
Stanowisko laboratoryjne do automatycznego pomiaru wybranych charakterystyk przetwornic DC/DC oraz liniowych stabilizatorów napięcia
W pracy przedstawiono stanowisko laboratoryjne do badania przetwornic DC/DC. Podstawowymi elementami stanowiska są komputer z autorskim oprogramowaniem oraz przyrządy programowalne. W artykule przedstawiono możliwości wykonanego oprogramowania oraz wyniki badań przykładowych układów przetwarzających napięcie: impulsowego i liniowego.
- 1 January 2020
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 96 (12) , 154-157
Laboratory stands for generating an alternating magnetic field
The research paper reviews two laboratory stands, based on a Helmholtz coil, for generating an alternating magnetic field. The first stand enables generating an alternating magnetic field of any shape and frequency up to 26 Hz. The task of the second one is to generate an attenuated harmonic signal, with a fundamental frequency of 7.7 kHz. The article also presents a time waveform of the generated magnetic field.
- 1 January 2020
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 96 (12) , 154-157
Laboratory stands for generating an alternating magnetic field
The research paper reviews two laboratory stands, based on a Helmholtz coil, for generating an alternating magnetic field. The first stand enables generating an alternating magnetic field of any shape and frequency up to 26 Hz. The task of the second one is to generate an attenuated harmonic signal, with a fundamental frequency of 7.7 kHz. The article also presents a time waveform of the generated magnetic field.
- 5 December 2019
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (12) , 95-98
Badania prototypowego detektora pola magnetycznego, w szczególności impulsów HPEM
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- 5 December 2019
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (12) , 95-98
Badania prototypowego detektora pola magnetycznego, w szczególności impulsów HPEM
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- 5 November 2019
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (11) , 142-145
Badanie modułu przyspieszenia na potrzeby diagnostyki czujników inercyjnych
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- 5 November 2019
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (11) , 142-145
Badanie modułu przyspieszenia na potrzeby diagnostyki czujników inercyjnych
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- 27 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11055, 16
Testing of the detector based on the Faraday effect for the detection of high-power electromagnetic pulses
Currently, high-power electromagnetic pulses are detected through antennas with conductive elements, which can causing the measured wave to interfere with waves reflected from metal elements. Moreover, they are characterized by a strongly non-linear frequency nature. Additional measuring system elements, such as a balun, attenuators, a limiter, which also impact the transmittance of the entire system are also used frequently. Appropriate selection of attenuation values when testing electromagnetic signals with unknown parameters is also problematic. An important aspect is also ensuring adequate detector resistance to the impact of high-power electromagnetic pulses. The paper discusses the test results for a prototype optoelectronic transducer based on the Faraday effect. The detector is designed in the fully dielectric technology. The system enables detecting a magnetic component of an electromagnetic field. Very similar amplitude values and signal shapes were obtained during the first tests involving the recording of system responses upon harmonic excitations with selected frequencies. The transfer characteristics for selected optical signal wavelengths (660 nm and 880 nm) were also measured, and a system response upon magnetic field pulse excitation was also recorded. Based on the measurements taken when determining the transfer characteristics, the linear correlation coefficients for a system operating at various optical light wavelengths were calculated. The incidence results also showed the need to conduct further studies in terms of increasing the sensitivity of the constructed detector. The disturbance level on the detector output should also be limited.
- 27 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11055, 16
Testing of the detector based on the Faraday effect for the detection of high-power electromagnetic pulses
Currently, high-power electromagnetic pulses are detected through antennas with conductive elements, which can causing the measured wave to interfere with waves reflected from metal elements. Moreover, they are characterized by a strongly non-linear frequency nature. Additional measuring system elements, such as a balun, attenuators, a limiter, which also impact the transmittance of the entire system are also used frequently. Appropriate selection of attenuation values when testing electromagnetic signals with unknown parameters is also problematic. An important aspect is also ensuring adequate detector resistance to the impact of high-power electromagnetic pulses. The paper discusses the test results for a prototype optoelectronic transducer based on the Faraday effect. The detector is designed in the fully dielectric technology. The system enables detecting a magnetic component of an electromagnetic field. Very similar amplitude values and signal shapes were obtained during the first tests involving the recording of system responses upon harmonic excitations with selected frequencies. The transfer characteristics for selected optical signal wavelengths (660 nm and 880 nm) were also measured, and a system response upon magnetic field pulse excitation was also recorded. Based on the measurements taken when determining the transfer characteristics, the linear correlation coefficients for a system operating at various optical light wavelengths were calculated. The incidence results also showed the need to conduct further studies in terms of increasing the sensitivity of the constructed detector. The disturbance level on the detector output should also be limited.
- 5 December 2018
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (12) , 268-271
Studying fibre-optic link used to transmission an analogue signals
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- 5 December 2018
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (12) , 268-271
Studying fibre-optic link used to transmission an analogue signals
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- Open Access
- 30 September 2018
- Published by JVE International Ltd. in Journal of Measurements in Engineering
- Vol. 6 (3) , 137-142
Modelling and static analysis of the alar cast partial with regard to the base elasticity
The paper presents an analysis of a unilateral cast partial denture supported by the gum soft tissue with the use of the Finite Element Method (FEM) [1, 2]. In the previous considerations in the papers [3, 4], the analysis of the denture is carried out for the case, in which a movable wing is not supported, while in real conditions, the denture is placed on the elastic base of the palate soft tissues. However, the model of the elastic support, proposed in the paper [5, 6], was used only for the analysis of the bilateral cast partial denture. In the following paper, this model was used for the static analysis of the unilateral alar cast partial [7].
- 30 September 2018
- Published by JVE International Ltd. in Journal of Measurements in Engineering
- Vol. 6 (3) , 137-142
Open AccessModelling and static analysis of the alar cast partial with regard to the base elasticity
The paper presents an analysis of a unilateral cast partial denture supported by the gum soft tissue with the use of the Finite Element Method (FEM) [1, 2]. In the previous considerations in the papers [3, 4], the analysis of the denture is carried out for the case, in which a movable wing is not supported, while in real conditions, the denture is placed on the elastic base of the palate soft tissues. However, the model of the elastic support, proposed in the paper [5, 6], was used only for the analysis of the bilateral cast partial denture. In the following paper, this model was used for the static analysis of the unilateral alar cast partial [7].