Azuhar Ripin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Azuhar Ripin has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Asyraf Aman
NuclearScience Program, Faculty of Science and Technology, Universiti Kebangsaan Malaysia (UKM), 43650 Bandar Baru Bangi, Selangor, Malaysia
1 shared publicationF. Mohamed
1 shared publicationFaizal Mohamed
NuclearScience Program, Faculty of Science and Technology, Universiti Kebangsaan Malaysia (UKM), 43650 Bandar Baru Bangi, Selangor, Malaysia
1 shared publication- Faizal Mohamed
School of Applied Physics Studies
1 shared publication M.R. Yusof
1 shared publication- Mohd Idzat Idris
Universiti Kebangsaan Malaysia
1 shared publication
Latest Publications
- Open Access
- 28 February 2019
- Published by Penerbit Universiti Kebangsaan Malaysia (UKM Press) in Sains Malaysiana
- Vol. 48 (2) , 443-449
Kesan Integriti Pemerisaian Sinaran Seramik Mullite-Barite (MBC) terhadap Kejadian Kebakaran
- 28 February 2019
- Published by Penerbit Universiti Kebangsaan Malaysia (UKM Press) in Sains Malaysiana
- Vol. 48 (2) , 443-449
Open AccessKesan Integriti Pemerisaian Sinaran Seramik Mullite-Barite (MBC) terhadap Kejadian Kebakaran
- 4 April 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1940 (1) , 020008
Synthesis of mullite (3Al2O32SiO2) from local kaolin for radiation shielding
Raw kaolin from Kota Tinggi, Johor was used in this study to produce ceramic mullite (3Al2O22SiO2) for radiation shielding materials. In this work, an attempt was made to study the potential of local minerals to be used as a shielding barrier for diagnostic radiology radiation facilities in hospitals and medical centers throughout Malaysia. The conventional ceramic processing route was employed in the study using different pressing strength and sintering time. The obtained samples were characterized using X-ray diffractometer (XRD) for phase identification of each of the samples. The lead equivalent (LE) test was carried out using 15.05 mCi Cobalt-57 with gamma energy of 122 keV to compute the abilities of the mullite ceramic samples to attenuate the radiation. XRD patterns of prepared ceramics revealed the presence of orthorhombic mullite, hexagonal quartz and orthorhombic sillimanite structures. Furthermore, the radiation test displayed the ability of ceramics to shield of 70 % of gamma radiation at the distance of 60 cm from the radiation source. The highest lead equivalent thickness is 1.0 mm Pb and the lowest is about 0.06 mm Pb. From the result, it is shown that the ceramic has the potential to use as a shielding barrier in diagnostic radiology facilities due to the ability of reducing the radiation dose up to 70 % from its initial value.
- 4 April 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1940 (1) , 020008
Synthesis of mullite (3Al2O32SiO2) from local kaolin for radiation shielding
Raw kaolin from Kota Tinggi, Johor was used in this study to produce ceramic mullite (3Al2O22SiO2) for radiation shielding materials. In this work, an attempt was made to study the potential of local minerals to be used as a shielding barrier for diagnostic radiology radiation facilities in hospitals and medical centers throughout Malaysia. The conventional ceramic processing route was employed in the study using different pressing strength and sintering time. The obtained samples were characterized using X-ray diffractometer (XRD) for phase identification of each of the samples. The lead equivalent (LE) test was carried out using 15.05 mCi Cobalt-57 with gamma energy of 122 keV to compute the abilities of the mullite ceramic samples to attenuate the radiation. XRD patterns of prepared ceramics revealed the presence of orthorhombic mullite, hexagonal quartz and orthorhombic sillimanite structures. Furthermore, the radiation test displayed the ability of ceramics to shield of 70 % of gamma radiation at the distance of 60 cm from the radiation source. The highest lead equivalent thickness is 1.0 mm Pb and the lowest is about 0.06 mm Pb. From the result, it is shown that the ceramic has the potential to use as a shielding barrier in diagnostic radiology facilities due to the ability of reducing the radiation dose up to 70 % from its initial value.
- 1 March 2018
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 144, 63-68
X-ray shielding behaviour of kaolin derived mullite-barites ceramic
- 1 March 2018
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 144, 63-68
X-ray shielding behaviour of kaolin derived mullite-barites ceramic