VNVyacheslav M. Nekrasov

Vyacheslav M. Nekrasov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vyacheslav M. Nekrasov has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Analytically optimized noise redistribution in pulsed dipolar EPR spectroscopy

    by Vyacheslav M. Nekrasov, Anna G. Matveeva, Victoria N. Syryamina, Semyon Andreevich Agarkin, Michael K. Bowman

    Non-uniform data acquisition protocols are derived analytically for optimizing the measurement of nanometer distance using pulsed dipolar spectroscopy methods, such as DEER (double electron–electron resonance).

  • Application of RBF Neural Networks for Solving the Inverse Light Scattering Problem of Platelets

    by Evgeniy A. Aleksandrov, Konstantin V. Gilev, Alena L. Litvinenko, Vyacheslav M. Nekrasov, Dmitry I. Strokotov, Valeri P. Maltsev

    In this paper, the possibility of using Radial Basis Function (RBF) neural networks to solve the inverse problem of light scattering for platelets is considered. The database of theoretical signals has been generated by the discrete dipole approximation (DDA) method and has been used to train the predictive model. The method is tested on model and experimental data. The main features of the RBF neural network solution method have been considered and compared with the DATABASE method. The error of solving the inverse problem for the proposed neural network model was 6.4-11 % with a solution time of 8ms.

  • Open Access

    Non-uniform sampling in pulse dipolar spectroscopy by EPR: the redistribution of noise and the optimization of data acquisition

    by Anna G. Matveeva, Victoria N. Syryamina, Vyacheslav M. Nekrasov, Michael K. Bowman

    Pulse dipolar spectroscopy (PDS) in Electron Paramagnetic Resonance (EPR) is the method of choice for determining the distance distribution function for mono-, bi- or multi- spin-labeled macromolecules and nanostructures. PDS acquisition schemes conventionally use uniform sampling of the dipolar trace, but non-uniform sampling (NUS) schemes can decrease the total measurement time or increase the accuracy of the resulting distance distributions. NUS requires optimization of the data acquisition scheme, as well as changes in data processing algorithms to accommodate the non-uniformly sampled data. We investigate in silico the applicability of the NUS approach in PDS, considering its effect on random, truncation and sampling noise in the experimental data. Each type of noise in the time-domain data propagates differently and non-uniformly into the distance spectrum as errors in the distance distribution. NUS schemes seem to be a valid approach for increasing sensitivity and/or throughput in PDS by decreasing and redistributing noise in the distance spectrum so that it has less impact on the distance spectrum.


  • Kinetic turbidimetry of patchy colloids aggregation: Latex particles immunoagglutination

    by Alexey A. Polshchitsin, Vyacheslav M. Nekrasov, Valentin S. Zakovryashin, Galina E. Yakovleva, Valeri P. Maltsev, Maxim A. Yurkin, Andrei V. Chernyshev


  • Open Access

    Fluorescence‐free flow cytometry for measurement of shape index distribution of resting, partially activated, and fully activated platelets

    by A.L. Litvinenko, A.E. Moskalensky, N.A. Karmadonova, V.M. Nekrasov, D.I. Strokotov, A.I. Konokhova, M.A. Yurkin, E.A. Pokushalov, A.V. Chernyshev, V.P. Maltsev

    Whereas commercially available hematological analyzers measure volume of individual platelets, angle‐resolved light‐scattering provides unique ability to additionally measure their shape index. We utilized the scanning flow cytometer to measure light‐scattering profiles (LSPs) of individual platelets taken from 16 healthy donors and the solution of the inverse light‐scattering problem to retrieve the volume and shape index of each platelet. In normal conditions, the platelet shape index distribution (PSID) demonstrates three peaks, which relate to resting, partially activated, and fully activated platelets. We developed an algorithm, based on fitting PSID by a sum of three peak functions, to determine the percentage, mean platelet shape index, and distribution width of each platelet fraction. In total, this method gives eight additional parameters of platelet morphology and function to be used in clinical hematological analysis. We also stimulated the platelets with adenosine diphosphate (ADP) and measured the dependence of equilibrium PSID, including the total percentage of activated platelets, on ADP concentration. © 2016 International Society for Advancement of Cytometry


  • Erratum to Dynamic quantification of antigen molecules with flow cytometry [Journal of Immunological Methods, Volume 418, March 2015, Pages 66–74]

    by A.E. Moskalensky, A.V. Chernyshev, M.A. Yurkin, V.M. Nekrasov, A.A. Polshchitsin, D.R. Parks, W.A. Moore, A. Filatenkov, V.P. Maltsev, D.Y. Orlova


  • Dynamic quantification of antigen molecules with flow cytometry

    by A.E. Moskalensky, A.V. Chernyshev, M.A. Yurkin, V.M. Nekrasov, A.A. Polshchitsin, D.R. Parks, W.A. Moore, A. Filatenkov, V.P. Maltsev, D.Y. Orlova


  • Brownian aggregation rate of colloid particles with several active sites

    by Vyacheslav M. Nekrasov, Alexey A. Polshchitsin, Maxim A. Yurkin, Galina E. Yakovleva, Valeri P. Maltsev, Andrei V. Chernyshev

    We theoretically analyze the aggregation kinetics of colloid particles with several active sites. Such particles (so-called “patchy particles”) are well known as chemically anisotropic reactants, but the corresponding rate constant of their aggregation has not yet been established in a convenient analytical form. Using kinematic approximation for the diffusion problem, we derived an analytical formula for the diffusion-controlled reaction rate constant between two colloid particles (or clusters) with several small active sites under the following assumptions: the relative translational motion is Brownian diffusion, and the isotropic stochastic reorientation of each particle is Markovian and arbitrarily correlated. This formula was shown to produce accurate results in comparison with more sophisticated approaches. Also, to account for the case of a low number of active sites per particle we used Monte Carlo stochastic algorithm based on Gillespie method. Simulations showed that such discrete model is required when this number is less than 10. Finally, we applied the developed approach to the simulation of immunoagglutination, assuming that the formed clusters have fractal structure.


  • Accurate measurement of volume and shape of resting and activated blood platelets from light scattering

    by Alexander E. Moskalensky, Maxim A. Yurkin, Anastasiya I. Konokhova, Dmitry I. Strokotov, Vyacheslav M. Nekrasov, Andrei V. Chernyshev, Galina A. Tsvetovskaya, Elena D. Chikova, Valeri P. Maltsev

    We introduce a novel approach for determination of volume and shape of individual blood platelets modeled as an oblate spheroid from angle-resolved light scattering with flow-cytometric technique. The light-scattering profiles (LSPs) of individual platelets were measured with the scanning flow cytometer and the platelet characteristics were determined from the solution of the inverse light-scattering problem using the precomputed database of theoretical LSPs. We revealed a phenomenon of parameter compensation, which is partly explained in the framework of anomalous diffraction approximation. To overcome this problem, additional a priori information on the platelet refractive index was used. It allowed us to determine the size of each platelet with subdiffraction precision and independent of the particular value of the platelet aspect ratio. The shape (spheroidal aspect ratio) distributions of platelets showed substantial differences between native and activated by 10 μM adenosine diphosphate samples. We expect that the new approach may find use in hematological analyzers for accurate measurement of platelet volume distribution and for determination of the platelet activation efficiency.


  • Open Access

    Polarized light‐scattering profile—advanced characterization of nonspherical particles with scanning flow cytometry

    by Dmitry I. Strokotov, Alexander E. Moskalensky, Vyacheslav M. Nekrasov, Valeri P. Maltsev

    We instrumentally, theoretically, and experimentally demonstrate a new approach for characterization of nonspherical individual particles from light scattering. Unlike the original optical scheme of the scanning flow cytometer that measures an angle-resolved scattering corresponding in general to S11 element of the light-scattering matrix, the modernized instrument allows us to measure the polarized light-scattering profile of individual particles simultaneously. Theoretically, the polarized profile is expressed by the combination of a few light-scattering matrix elements. This approach supports us with additional independent data to characterize a particle with a complex shape and an internal structure. Applicability of the new method was demonstrated from analysis of polymer bispheres. The bisphere characteristics, sizes, and refractive indices of each sphere composing the bisphere were successfully retrieved from the solution of the inverse light-scattering problem. The solution provides determination of the Eulerian angles, which describe the orientation of the bispheres relative to the direction of the incident laser beam and detecting polarizer of the optical system. Both the ordinary and polarized profiles show a perfect agreement with T-matrix simulation resulting to 50-nm precision for sizing of bispheres. © 2011 International Society for Advancement of Cytometry.