Xiaojia Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xiaojia Jin has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- Michael S. Strano
Massachusetts Institute of Technology
12 shared publications - Volodymyr B. Koman
Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, United States
6 shared publications Manki Son
Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, United States
5 shared publicationsXun Gong
Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, USA
5 shared publications- Freddy T. Nguyen
Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, USA
4 shared publications Michael A. Lee
Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
4 shared publications
Latest Publications
- Open Access
- 6 July 2026
- Published by Springer Nature in Nature Nanotechnology
- Vol. 21 (8) , 1215
Publisher Correction: Chemical efflux imaging using an annular nanosensor array for in situ bladder cancer detection
- 6 July 2026
- Published by Springer Nature in Nature Nanotechnology
- Vol. 21 (8) , 1215
Open AccessPublisher Correction: Chemical efflux imaging using an annular nanosensor array for in situ bladder cancer detection
- 27 May 2026
- Published by Springer Nature in Nature Nanotechnology
- Vol. 21 (6) , 869-879
Chemical efflux imaging using an annular nanosensor array for in situ bladder cancer detection
Detection of analytes in extracted biofluids, such as urine for bladder cancer biomarkers, is challenging owing to sample dilution and instability outside the human body. Here we demonstrate an annular nanosensor array grafted onto a standard biomedical catheter, which enables three-dimensional chemical efflux imaging from within a tissue compartment or luminal space. This platform integrates near-infrared fluorescent single-walled carbon nanotubes with the catheter, leveraging a ball-lens scanning optical device for chemical signal mapping. We develop nanosensors based on a phospholipid copolymer that selectively detect nuclear matrix protein (NMP-22), a biomarker for bladder cancer. The results show differential sensor responses between apoptosis in six bladder cancer cell lines and healthy fibroblast cells. Nanosensor-functionalized catheters track gemcitabine-stimulated cell death and monitor protein efflux in vitro. We demonstrate spatial imaging of incident chemical flux using this platform, achieving localization of biomarker sources in complex tissues and organs with 182-fold signal enhancement compared with extracted biofluid sampling. As an application, the catheter equipped with a rotating ball lens chemically images porcine bladders, detecting biomarker efflux up to 2 cm away, highlighting its potential as a point-of-care diagnostic tool.
- 27 May 2026
- Published by Springer Nature in Nature Nanotechnology
- Vol. 21 (6) , 869-879
Chemical efflux imaging using an annular nanosensor array for in situ bladder cancer detection
Detection of analytes in extracted biofluids, such as urine for bladder cancer biomarkers, is challenging owing to sample dilution and instability outside the human body. Here we demonstrate an annular nanosensor array grafted onto a standard biomedical catheter, which enables three-dimensional chemical efflux imaging from within a tissue compartment or luminal space. This platform integrates near-infrared fluorescent single-walled carbon nanotubes with the catheter, leveraging a ball-lens scanning optical device for chemical signal mapping. We develop nanosensors based on a phospholipid copolymer that selectively detect nuclear matrix protein (NMP-22), a biomarker for bladder cancer. The results show differential sensor responses between apoptosis in six bladder cancer cell lines and healthy fibroblast cells. Nanosensor-functionalized catheters track gemcitabine-stimulated cell death and monitor protein efflux in vitro. We demonstrate spatial imaging of incident chemical flux using this platform, achieving localization of biomarker sources in complex tissues and organs with 182-fold signal enhancement compared with extracted biofluid sampling. As an application, the catheter equipped with a rotating ball lens chemically images porcine bladders, detecting biomarker efflux up to 2 cm away, highlighting its potential as a point-of-care diagnostic tool.
- Open Access
- 21 April 2026
- Published by Springer Nature in Nature Synthesis
- Vol. 5 (9) , 1385-1393
Handle-free attachment of small molecules on single-walled carbon nanotubes
Few chemical methods controllably generate sp 3 defects on single-walled carbon nanotubes, and fewer still create quantum wells that localize excitons and enhance near-infrared emission. Here we describe an aqueous, nanotube-catalysed Fenton reaction that enables the conjugation of an extensive range of small molecules lacking traditional single-walled carbon nanotube conjugation handles, generating quantum well defects with tunable electro-optical properties. We demonstrate the attachment of over 150 unique small molecules, including alcohols, amines, carbonyls, acrylates, amino acids and peptides. The resulting optical properties are governed by the electronic structure of the attached group, which determines the relative configuration of defects (ortho or para) within the graphitic lattice. Time-dependent density functional theory calculations confirm the assignment of the observed emission peaks to specific defect configurations. These molecularly driven effects enable precise control over the optical properties of the nanotubes, broadening the design space of rationally engineered quantum well-bearing nanomaterials.
- 21 April 2026
- Published by Springer Nature in Nature Synthesis
- Vol. 5 (9) , 1385-1393
Open AccessHandle-free attachment of small molecules on single-walled carbon nanotubes
Few chemical methods controllably generate sp 3 defects on single-walled carbon nanotubes, and fewer still create quantum wells that localize excitons and enhance near-infrared emission. Here we describe an aqueous, nanotube-catalysed Fenton reaction that enables the conjugation of an extensive range of small molecules lacking traditional single-walled carbon nanotube conjugation handles, generating quantum well defects with tunable electro-optical properties. We demonstrate the attachment of over 150 unique small molecules, including alcohols, amines, carbonyls, acrylates, amino acids and peptides. The resulting optical properties are governed by the electronic structure of the attached group, which determines the relative configuration of defects (ortho or para) within the graphitic lattice. Time-dependent density functional theory calculations confirm the assignment of the observed emission peaks to specific defect configurations. These molecularly driven effects enable precise control over the optical properties of the nanotubes, broadening the design space of rationally engineered quantum well-bearing nanomaterials.
- 29 May 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (6) , 4423-4433
A Nanosensor Platform for Biologging in Marine Animals
Biologging has significantly advanced ecological biology by enabling the collection of data from free-roaming animals in their natural habitats. Traditionally, these measurements have largely been limited to temperature, pressure, and movement. Incorporating physiological data of animal biomarkers could yield valuable orthogonal data sets, providing a more nuanced understanding of organisms in the context of their environments and behaviors. Despite this potential, successful collection of such biochemical information remains absent and thus motivates new sensor platforms. Toward this end, we explore the hardware and nanosensor optimization of animal implantable sensors for tracking hormone levels in marine animals. The transducer element is based on polymer-wrapped single-walled carbon nanotubes that act as nanosensors embedded within a biocompatible poly(ethylene glycol) diacrylate hydrogel. This work investigates the performance of the nanosensor hydrogel under various temperatures, illumination conditions, and nanoparticle concentrations in the hydrogel. We further prototype a miniaturized fluorescent system for integration into existing, commercially available acoustic tags widely used in marine biology studies. We demonstrate a baseline of 100 nM for the detection limit of progesterone as an example of an important hormone in marine animals using the integrated nanosensor hydrogel in this platform. Further improvement is possible with optimization of the signal-to-noise ratio via hardware development. This developed form-factor will complement the presently collected data by providing insights into the physiological state of the animals in the context of their behavior and environments.
- 29 May 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (6) , 4423-4433
A Nanosensor Platform for Biologging in Marine Animals
Biologging has significantly advanced ecological biology by enabling the collection of data from free-roaming animals in their natural habitats. Traditionally, these measurements have largely been limited to temperature, pressure, and movement. Incorporating physiological data of animal biomarkers could yield valuable orthogonal data sets, providing a more nuanced understanding of organisms in the context of their environments and behaviors. Despite this potential, successful collection of such biochemical information remains absent and thus motivates new sensor platforms. Toward this end, we explore the hardware and nanosensor optimization of animal implantable sensors for tracking hormone levels in marine animals. The transducer element is based on polymer-wrapped single-walled carbon nanotubes that act as nanosensors embedded within a biocompatible poly(ethylene glycol) diacrylate hydrogel. This work investigates the performance of the nanosensor hydrogel under various temperatures, illumination conditions, and nanoparticle concentrations in the hydrogel. We further prototype a miniaturized fluorescent system for integration into existing, commercially available acoustic tags widely used in marine biology studies. We demonstrate a baseline of 100 nM for the detection limit of progesterone as an example of an important hormone in marine animals using the integrated nanosensor hydrogel in this platform. Further improvement is possible with optimization of the signal-to-noise ratio via hardware development. This developed form-factor will complement the presently collected data by providing insights into the physiological state of the animals in the context of their behavior and environments.
- Open Access
- 21 August 2023
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Information Systems
- Vol. 42 (1) , 1-32
M3GAT: A Multi-modal, Multi-task Interactive Graph Attention Network for Conversational Sentiment Analysis and Emotion Recognition
Sentiment and emotion, which correspond to long-term and short-lived human feelings, are closely linked to each other, leading to the fact that sentiment analysis and emotion recognition are also two interdependent tasks in natural language processing (NLP). One task often leverages the shared knowledge from another task and performs better when solved in a joint learning paradigm. Conversational context dependency, multi-modal interaction, and multi-task correlation are three key factors that contribute to this joint paradigm. However, none of the recent approaches have considered them in a unified framework. To fill this gap, we propose a multi-modal, multi-task interactive graph attention network, termed M3GAT, to simultaneously solve the three problems. At the heart of the model is a proposed interactive conversation graph layer containing three core sub-modules, which are: (1) local-global context connection for modeling both local and global conversational context, (2) cross-modal connection for learning multi-modal complementary and (3) cross-task connection for capturing the correlation across two tasks. Comprehensive experiments on three benchmarking datasets, MELD, MEISD, and MSED, show the effectiveness of M3GAT over state-of-the-art baselines with the margin of 1.88%, 5.37%, and 0.19% for sentiment analysis, and 1.99%, 3.65%, and 0.13% for emotion recognition, respectively. In addition, we also show the superiority of multi-task learning over the single-task framework.
- 21 August 2023
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Information Systems
- Vol. 42 (1) , 1-32
Open AccessM3GAT: A Multi-modal, Multi-task Interactive Graph Attention Network for Conversational Sentiment Analysis and Emotion Recognition
Sentiment and emotion, which correspond to long-term and short-lived human feelings, are closely linked to each other, leading to the fact that sentiment analysis and emotion recognition are also two interdependent tasks in natural language processing (NLP). One task often leverages the shared knowledge from another task and performs better when solved in a joint learning paradigm. Conversational context dependency, multi-modal interaction, and multi-task correlation are three key factors that contribute to this joint paradigm. However, none of the recent approaches have considered them in a unified framework. To fill this gap, we propose a multi-modal, multi-task interactive graph attention network, termed M3GAT, to simultaneously solve the three problems. At the heart of the model is a proposed interactive conversation graph layer containing three core sub-modules, which are: (1) local-global context connection for modeling both local and global conversational context, (2) cross-modal connection for learning multi-modal complementary and (3) cross-task connection for capturing the correlation across two tasks. Comprehensive experiments on three benchmarking datasets, MELD, MEISD, and MSED, show the effectiveness of M3GAT over state-of-the-art baselines with the margin of 1.88%, 5.37%, and 0.19% for sentiment analysis, and 1.99%, 3.65%, and 0.13% for emotion recognition, respectively. In addition, we also show the superiority of multi-task learning over the single-task framework.
- 26 May 2023
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 6 (11) , 9791-9804
Corona Phase Molecular Recognition of the Interleukin-6 (IL-6) Family of Cytokines Using nIR Fluorescent Single-Walled Carbon Nanotubes
- 26 May 2023
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 6 (11) , 9791-9804
Corona Phase Molecular Recognition of the Interleukin-6 (IL-6) Family of Cytokines Using nIR Fluorescent Single-Walled Carbon Nanotubes
- Open Access
- 24 April 2023
- Published by Springer Nature in Journal of Nanobiotechnology
- Vol. 21 (1) , 1-11
In-Vivo fluorescent nanosensor implants based on hydrogel-encapsulation: investigating the inflammation and the foreign-body response
Nanotechnology-enabled sensors or nanosensors are emerging as promising new tools for various in-vivo life science applications such as biosensing, components of delivery systems, and probes for spatial bioimaging. However, as with a wide range of synthetic biomaterials, tissue responses have been observed depending on cell types and various nanocomponent properties. The tissue response is critical for determining the acute and long term health of the organism and the functional lifetime of the material in-vivo. While nanomaterial properties can contribute significantly to the tissue response, it may be possible to circumvent adverse reactions by formulation of the encapsulation vehicle. In this study, five formulations of poly (ethylene glycol) diacrylate (PEGDA) hydrogel-encapsulated fluorescent nanosensors were implanted into SKH-1E mice, and the inflammatory responses were tracked in order to determine the favorable design rules for hydrogel encapsulation and minimization of such responses. Hydrogels with higher crosslinking density were found to allow faster resolution of acute inflammation. Five different immunocompromised mice lines were utilized for comparison across different inflammatory cell populations and responses. Degradation products of the gels were also characterized. Finally, the importance of the tissue response in determining functional lifetime was demonstrated by measuring the time-dependent nanosensor deactivation following implantation into animal models.
- 24 April 2023
- Published by Springer Nature in Journal of Nanobiotechnology
- Vol. 21 (1) , 1-11
Open AccessIn-Vivo fluorescent nanosensor implants based on hydrogel-encapsulation: investigating the inflammation and the foreign-body response
Nanotechnology-enabled sensors or nanosensors are emerging as promising new tools for various in-vivo life science applications such as biosensing, components of delivery systems, and probes for spatial bioimaging. However, as with a wide range of synthetic biomaterials, tissue responses have been observed depending on cell types and various nanocomponent properties. The tissue response is critical for determining the acute and long term health of the organism and the functional lifetime of the material in-vivo. While nanomaterial properties can contribute significantly to the tissue response, it may be possible to circumvent adverse reactions by formulation of the encapsulation vehicle. In this study, five formulations of poly (ethylene glycol) diacrylate (PEGDA) hydrogel-encapsulated fluorescent nanosensors were implanted into SKH-1E mice, and the inflammatory responses were tracked in order to determine the favorable design rules for hydrogel encapsulation and minimization of such responses. Hydrogels with higher crosslinking density were found to allow faster resolution of acute inflammation. Five different immunocompromised mice lines were utilized for comparison across different inflammatory cell populations and responses. Degradation products of the gels were also characterized. Finally, the importance of the tissue response in determining functional lifetime was demonstrated by measuring the time-dependent nanosensor deactivation following implantation into animal models.
- 30 May 2022
- Published by Springer Nature in Nature Nanotechnology
- Vol. 17 (6) , 643-652
A wavelength-induced frequency filtering method for fluorescent nanosensors in vivo
Fluorescent nanosensors hold the potential to revolutionize life sciences and medicine. However, their adaptation and translation into the in vivo environment is fundamentally hampered by unfavourable tissue scattering and intrinsic autofluorescence. Here we develop wavelength-induced frequency filtering (WIFF) whereby the fluorescence excitation wavelength is modulated across the absorption peak of a nanosensor, allowing the emission signal to be separated from the autofluorescence background, increasing the desired signal relative to noise, and internally referencing it to protect against artefacts. Using highly scattering phantom tissues, an SKH1-E mouse model and other complex tissue types, we show that WIFF improves the nanosensor signal-to-noise ratio across the visible and near-infrared spectra up to 52-fold. This improvement enables the ability to track fluorescent carbon nanotube sensor responses to riboflavin, ascorbic acid, hydrogen peroxide and a chemotherapeutic drug metabolite for depths up to 5.5 ± 0.1 cm when excited at 730 nm and emitting between 1,100 and 1,300 nm, even allowing the monitoring of riboflavin diffusion in thick tissue. As an application, nanosensors aided by WIFF detect the chemotherapeutic activity of temozolomide transcranially at 2.4 ± 0.1 cm through the porcine brain without the use of fibre optic or cranial window insertion. The ability of nanosensors to monitor previously inaccessible in vivo environments will be important for life-sciences research, therapeutics and medical diagnostics.
- 30 May 2022
- Published by Springer Nature in Nature Nanotechnology
- Vol. 17 (6) , 643-652
A wavelength-induced frequency filtering method for fluorescent nanosensors in vivo
Fluorescent nanosensors hold the potential to revolutionize life sciences and medicine. However, their adaptation and translation into the in vivo environment is fundamentally hampered by unfavourable tissue scattering and intrinsic autofluorescence. Here we develop wavelength-induced frequency filtering (WIFF) whereby the fluorescence excitation wavelength is modulated across the absorption peak of a nanosensor, allowing the emission signal to be separated from the autofluorescence background, increasing the desired signal relative to noise, and internally referencing it to protect against artefacts. Using highly scattering phantom tissues, an SKH1-E mouse model and other complex tissue types, we show that WIFF improves the nanosensor signal-to-noise ratio across the visible and near-infrared spectra up to 52-fold. This improvement enables the ability to track fluorescent carbon nanotube sensor responses to riboflavin, ascorbic acid, hydrogen peroxide and a chemotherapeutic drug metabolite for depths up to 5.5 ± 0.1 cm when excited at 730 nm and emitting between 1,100 and 1,300 nm, even allowing the monitoring of riboflavin diffusion in thick tissue. As an application, nanosensors aided by WIFF detect the chemotherapeutic activity of temozolomide transcranially at 2.4 ± 0.1 cm through the porcine brain without the use of fibre optic or cranial window insertion. The ability of nanosensors to monitor previously inaccessible in vivo environments will be important for life-sciences research, therapeutics and medical diagnostics.
- Open Access
Transcutaneous Measurement of Essential Vitamins Using Near‐Infrared Fluorescent Single‐Walled Carbon Nanotube Sensors
Vitamins such as riboflavin and ascorbic acid are frequently utilized in a range of biomedical applications as drug delivery targets, fluidic tracers, and pharmaceutical excipients. Sensing these biochemicals in the human body has the potential to significantly advance medical research and clinical applications. In this work, a nanosensor platform consisting of single‐walled carbon nanotubes (SWCNTs) with nanoparticle corona phases engineered to allow for the selective molecular recognition of ascorbic acid and riboflavin, is developed. The study provides a methodological framework for the implementation of colloidal SWCNT nanosensors in an intraperitoneal SKH1‐E murine model by addressing complications arising from tissue absorption and scattering, mechanical perturbations, as well as sensor diffusion and interactions with the biological environment. Nanosensors are encapsulated in a polyethylene glycol diacrylate hydrogel and a diffusion model is utilized to validate analyte transport and sensor responses to local concentrations at the boundary. Results are found to be reproducible and stable after exposure to 10% mouse serum even after three days of in vivo implantation. A geometrical encoding scheme is used to reference sensor pairs, correcting for in vivo optical and mechanical artifacts, resulting in an order of magnitude improvement of p‐value from 0.084 to 0.003 during analyte sensing.
Open AccessTranscutaneous Measurement of Essential Vitamins Using Near‐Infrared Fluorescent Single‐Walled Carbon Nanotube Sensors
Vitamins such as riboflavin and ascorbic acid are frequently utilized in a range of biomedical applications as drug delivery targets, fluidic tracers, and pharmaceutical excipients. Sensing these biochemicals in the human body has the potential to significantly advance medical research and clinical applications. In this work, a nanosensor platform consisting of single‐walled carbon nanotubes (SWCNTs) with nanoparticle corona phases engineered to allow for the selective molecular recognition of ascorbic acid and riboflavin, is developed. The study provides a methodological framework for the implementation of colloidal SWCNT nanosensors in an intraperitoneal SKH1‐E murine model by addressing complications arising from tissue absorption and scattering, mechanical perturbations, as well as sensor diffusion and interactions with the biological environment. Nanosensors are encapsulated in a polyethylene glycol diacrylate hydrogel and a diffusion model is utilized to validate analyte transport and sensor responses to local concentrations at the boundary. Results are found to be reproducible and stable after exposure to 10% mouse serum even after three days of in vivo implantation. A geometrical encoding scheme is used to reference sensor pairs, correcting for in vivo optical and mechanical artifacts, resulting in an order of magnitude improvement of p‐value from 0.084 to 0.003 during analyte sensing.
- Open Access
- 22 June 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-18
Nanophotonic biosensors harnessing van der Waals materials
Low-dimensional van der Waals (vdW) materials can harness tightly confined polaritonic waves to deliver unique advantages for nanophotonic biosensing. The reduced dimensionality of vdW materials, as in the case of two-dimensional graphene, can greatly enhance plasmonic field confinement, boosting sensitivity and efficiency compared to conventional nanophotonic devices that rely on surface plasmon resonance in metallic films. Furthermore, the reduction of dielectric screening in vdW materials enables electrostatic tunability of different polariton modes, including plasmons, excitons, and phonons. One-dimensional vdW materials, particularly single-walled carbon nanotubes, possess unique form factors with confined excitons to enable single-molecule detection as well as in vivo biosensing. We discuss basic sensing principles based on vdW materials, followed by technological challenges such as surface chemistry, integration, and toxicity. Finally, we highlight progress in harnessing vdW materials to demonstrate new sensing functionalities that are difficult to perform with conventional metal/dielectric sensors.
- 22 June 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-18
Open AccessNanophotonic biosensors harnessing van der Waals materials
Low-dimensional van der Waals (vdW) materials can harness tightly confined polaritonic waves to deliver unique advantages for nanophotonic biosensing. The reduced dimensionality of vdW materials, as in the case of two-dimensional graphene, can greatly enhance plasmonic field confinement, boosting sensitivity and efficiency compared to conventional nanophotonic devices that rely on surface plasmon resonance in metallic films. Furthermore, the reduction of dielectric screening in vdW materials enables electrostatic tunability of different polariton modes, including plasmons, excitons, and phonons. One-dimensional vdW materials, particularly single-walled carbon nanotubes, possess unique form factors with confined excitons to enable single-molecule detection as well as in vivo biosensing. We discuss basic sensing principles based on vdW materials, followed by technological challenges such as surface chemistry, integration, and toxicity. Finally, we highlight progress in harnessing vdW materials to demonstrate new sensing functionalities that are difficult to perform with conventional metal/dielectric sensors.