John Alexander
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
John Alexander has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Sergei Magonov
NT-MDT Development Inc., 430 W. Warner Road, Tempe, AZ 85284, U.S.A.
5 shared publicationsS. Belikov
NT-MDT Development Inc
3 shared publicationsSergey Belikov
NT-MDT Development Inc., 430 W. Warner Road, Tempe, AZ 85284, U.S.A.
3 shared publicationsB. A. Huber
Centre de Recherche sur les Ions, les Matériaux et la Photonique (CIMAP), CEA-CNRS-ENSICAEN, F-14070 Caen Cedex 05, France
2 shared publicationsC. Wall
NT-MDT Development Inc., Tempe, AZ
2 shared publicationsCraig Wall
NT-MDT Development Inc., 430 W. Warner Road, Tempe, AZ 85284, U.S.A.
2 shared publications
Latest Publications
- 3 September 2014
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 16 (40) , 21980-21987
Fragmentation of anthracene C14H10, acridine C13H9N and phenazine C12H8N2ions in collisions with atoms
We report experimental total, absolute, fragmentation cross sections for anthracene C14H10, acridine C13H9N, and phenazine C12H8N2 ions colliding with He at center-of-mass energies close to 100 eV. In addition, we report results for the same ions colliding with Ne, Ar, and Xe at higher energies. The total fragmentation cross sections for these three ions are the same within error bars for a given target. The measured fragment mass distributions reveal significant contributions from both delayed (≫10−12 s) statistical fragmentation processes as well as non-statistical, prompt (∼10−15 s), single atom knockout processes. The latter dominate and are often followed by secondary statistical fragmentation. Classical Molecular Dynamics (MD) simulations yield separate cross sections for prompt and delayed fragmentation which are consistent with the experimental results. The intensity of the single C/N-loss peak, the signature of non-statistical fragmentation, decreases with the number of N atoms in the parent ion. The fragment intensity distributions for losses of more than one C or N atom are rather similar for C14H10 and C13H9N but differ strongly for C12H8N2 where weak C–N bonds often remain in the fragments after the first fragmentation step. This greatly increases their probability to fragment further. Distributions of internal energy remaining in the fragments after knockout are obtained from the MD simulations.
- 3 September 2014
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 16 (40) , 21980-21987
Fragmentation of anthracene C14H10, acridine C13H9N and phenazine C12H8N2ions in collisions with atoms
We report experimental total, absolute, fragmentation cross sections for anthracene C14H10, acridine C13H9N, and phenazine C12H8N2 ions colliding with He at center-of-mass energies close to 100 eV. In addition, we report results for the same ions colliding with Ne, Ar, and Xe at higher energies. The total fragmentation cross sections for these three ions are the same within error bars for a given target. The measured fragment mass distributions reveal significant contributions from both delayed (≫10−12 s) statistical fragmentation processes as well as non-statistical, prompt (∼10−15 s), single atom knockout processes. The latter dominate and are often followed by secondary statistical fragmentation. Classical Molecular Dynamics (MD) simulations yield separate cross sections for prompt and delayed fragmentation which are consistent with the experimental results. The intensity of the single C/N-loss peak, the signature of non-statistical fragmentation, decreases with the number of N atoms in the parent ion. The fragment intensity distributions for losses of more than one C or N atom are rather similar for C14H10 and C13H9N but differ strongly for C12H8N2 where weak C–N bonds often remain in the fragments after the first fragmentation step. This greatly increases their probability to fragment further. Distributions of internal energy remaining in the fragments after knockout are obtained from the MD simulations.
- Open Access
- 17 July 2013
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 139 (3) , 034309
Ions colliding with clusters of fullerenes—Decay pathways and covalent bond formations
We report experimental results for the ionization and fragmentation of weakly bound van der Waals clusters of n C60 molecules following collisions with Ar2 +, He2 +, and Xe20 + at laboratory kinetic energies of 13 keV, 22.5 keV, and 300 keV, respectively. Intact singly charged C60 monomers are the dominant reaction products in all three cases and this is accounted for by means of Monte Carlo calculations of energy transfer processes and a simple Arrhenius-type → evaporation model. Excitation energies in the range of only ∼0.7 eV per C60 molecule in a cluster are sufficient for complete evaporation and such low energies correspond to ion trajectories far outside the clusters. Still we observe singly and even doubly charged intact cluster ions which stem from even more distant collisions. For penetrating collisions the clusters become multiply charged and some of the individual molecules may be promptly fragmented in direct knock-out processes leading to efficient formations of new covalent systems. For Ar2 + and He2 + collisions, we observe very efficient and formation and molecular dynamics simulations suggest that they are covalent dumb-bell systems due to bonding between or and C60 during cluster fragmentation. In the Ar2 + case, it is possible to form even smaller molecules (m = 2–7), while no molecular fusion reactions are observed for the present Xe20 + collisions.- 17 July 2013
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 139 (3) , 034309
Open AccessIons colliding with clusters of fullerenes—Decay pathways and covalent bond formations
We report experimental results for the ionization and fragmentation of weakly bound van der Waals clusters of n C60 molecules following collisions with Ar2 +, He2 +, and Xe20 + at laboratory kinetic energies of 13 keV, 22.5 keV, and 300 keV, respectively. Intact singly charged C60 monomers are the dominant reaction products in all three cases and this is accounted for by means of Monte Carlo calculations of energy transfer processes and a simple Arrhenius-type → evaporation model. Excitation energies in the range of only ∼0.7 eV per C60 molecule in a cluster are sufficient for complete evaporation and such low energies correspond to ion trajectories far outside the clusters. Still we observe singly and even doubly charged intact cluster ions which stem from even more distant collisions. For penetrating collisions the clusters become multiply charged and some of the individual molecules may be promptly fragmented in direct knock-out processes leading to efficient formations of new covalent systems. For Ar2 + and He2 + collisions, we observe very efficient and formation and molecular dynamics simulations suggest that they are covalent dumb-bell systems due to bonding between or and C60 during cluster fragmentation. In the Ar2 + case, it is possible to form even smaller molecules (m = 2–7), while no molecular fusion reactions are observed for the present Xe20 + collisions. - 15 May 2013
- Published by Springer Nature in MRS Proceedings
- Vol. 1527
Tip-Sample Forces in Atomic Force Microscopy: Interplay between Theory and Experiment
- 15 May 2013
- Published by Springer Nature in MRS Proceedings
- Vol. 1527
Tip-Sample Forces in Atomic Force Microscopy: Interplay between Theory and Experiment
- 25 January 2013
- Published by Springer Nature in MRS Proceedings
- Vol. 1500
Atomic Force Microscopy Based Electric Modes in Characterization of Organic Photovoltaics
- 25 January 2013
- Published by Springer Nature in MRS Proceedings
- Vol. 1500
Atomic Force Microscopy Based Electric Modes in Characterization of Organic Photovoltaics
- 26 September 2012
- Published by Springer Nature
- p. 203-253
Exploring Surfaces of Materials with Atomic Force Microscopy
- 26 September 2012
- Published by Springer Nature
- p. 203-253
Exploring Surfaces of Materials with Atomic Force Microscopy
- 1 July 2012
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 18 (S2) , 922-923
Advances in Atomic Force Microscopy, from Compositional Mapping to Quantitative Measurements
Extended abstract of a paper presented at Microscopy and Microanalysis 2012 in Phoenix, Arizona, USA, July 29 – August 2, 2012.
- 1 July 2012
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 18 (S2) , 922-923
Advances in Atomic Force Microscopy, from Compositional Mapping to Quantitative Measurements
Extended abstract of a paper presented at Microscopy and Microanalysis 2012 in Phoenix, Arizona, USA, July 29 – August 2, 2012.
- 1 July 2012
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 18 (S2) , 878-879
Optimization of Experiment in Traditional and Multi-Frequency Atomic Force Microscopy
Extended abstract of a paper presented at Microscopy and Microanalysis 2012 in Phoenix, Arizona, USA, July 29 – August 2, 2012.
- 1 July 2012
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 18 (S2) , 878-879
Optimization of Experiment in Traditional and Multi-Frequency Atomic Force Microscopy
Extended abstract of a paper presented at Microscopy and Microanalysis 2012 in Phoenix, Arizona, USA, July 29 – August 2, 2012.
- 1 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3228-3233
Atomic Force Microscopy control system for electrostatic measurements based on mechanical and electrical modulation
Atomic Force Microscopy (AFM) has excellent potential ability for quantitative electrostatic measurements of surface potential and dielectric permittivity of materials with nanoscale resolution. Implementation of this ability, however, requires overcoming several challenges. The first task is developing an accurate computational model for electrostatic tip-sample interaction; the second - efficient instrumentation and a control system that supports the measurements. An analytical model of nanoscale tip-sample capacitance on thin dielectric films was introduced (Gomila, Toset, and Fumagalli, 2008). This model allows describing the electrostatic tip-sample interaction force in a form suitable for the AFM dynamic control model (Belikov, Magonov, 2009). This dynamic model contains integrals over the tip-sample forces that can be presented in a closed form for the Gomila-Toset-Fumagalli analytical model. These results allow for developing very efficient electrostatic AFM computational model. As for the second task (instrumentation and control), the above mentioned AFM dynamic model with (amplitude-phase) state variables can be used for the control system design that combines mechanical Amplitude Modulation mode and consequent electrical modulation of the mechanical phase cosine. The cosine is monitored by lock-in amplifiers at the electrical modulation frequency, and twice that frequency; surface potential and dielectric permittivity of the sample can then be mapped. This paper presents the model derivation, description of instrumentation and control schematics, and their implementation on NT-MDT microscopes. Results are illustrated with practical measurements on different materials.
- 1 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3228-3233
Atomic Force Microscopy control system for electrostatic measurements based on mechanical and electrical modulation
Atomic Force Microscopy (AFM) has excellent potential ability for quantitative electrostatic measurements of surface potential and dielectric permittivity of materials with nanoscale resolution. Implementation of this ability, however, requires overcoming several challenges. The first task is developing an accurate computational model for electrostatic tip-sample interaction; the second - efficient instrumentation and a control system that supports the measurements. An analytical model of nanoscale tip-sample capacitance on thin dielectric films was introduced (Gomila, Toset, and Fumagalli, 2008). This model allows describing the electrostatic tip-sample interaction force in a form suitable for the AFM dynamic control model (Belikov, Magonov, 2009). This dynamic model contains integrals over the tip-sample forces that can be presented in a closed form for the Gomila-Toset-Fumagalli analytical model. These results allow for developing very efficient electrostatic AFM computational model. As for the second task (instrumentation and control), the above mentioned AFM dynamic model with (amplitude-phase) state variables can be used for the control system design that combines mechanical Amplitude Modulation mode and consequent electrical modulation of the mechanical phase cosine. The cosine is monitored by lock-in amplifiers at the electrical modulation frequency, and twice that frequency; surface potential and dielectric permittivity of the sample can then be mapped. This paper presents the model derivation, description of instrumentation and control schematics, and their implementation on NT-MDT microscopes. Results are illustrated with practical measurements on different materials.
- 1 February 2011
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 17 (4) , 587-597
Multifrequency Atomic Force Microscopy: Compositional Imaging with Electrostatic Force Measurements
We demonstrate that single-pass Kelvin force microscopy (KFM) and dC/dz measurements in different environments expand the compositional imaging with atomic force microscopy. The KFM and dC/dz studies were performed in the intermittent contact mode with force gradient detection of tip-sample electrostatic interactions. Both factors contribute to sensitive measurements of the surface potential and capacitance gradient with nanometer-scale spatial resolution as it was verified on a broad range of materials: metal alloys, polymers, organic layers, and liquid-like objects. For many samples the surface potential and dC/dz variations complement each other in identification of individual components of heterogeneous materials. In situ imaging in different humidity or vapors of various organic solvents further facilitate recognition of the constituents of multicomponent polymer samples due to selective swelling of components.
- 1 February 2011
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 17 (4) , 587-597
Multifrequency Atomic Force Microscopy: Compositional Imaging with Electrostatic Force Measurements
We demonstrate that single-pass Kelvin force microscopy (KFM) and dC/dz measurements in different environments expand the compositional imaging with atomic force microscopy. The KFM and dC/dz studies were performed in the intermittent contact mode with force gradient detection of tip-sample electrostatic interactions. Both factors contribute to sensitive measurements of the surface potential and capacitance gradient with nanometer-scale spatial resolution as it was verified on a broad range of materials: metal alloys, polymers, organic layers, and liquid-like objects. For many samples the surface potential and dC/dz variations complement each other in identification of individual components of heterogeneous materials. In situ imaging in different humidity or vapors of various organic solvents further facilitate recognition of the constituents of multicomponent polymer samples due to selective swelling of components.
- Open Access
- 6 January 2011
- Published by Beilstein Institut in Beilstein Journal of Nanotechnology
- Vol. 2 (1) , 15-27
Single-pass Kelvin force microscopy and dC/dZ measurements in the intermittent contact: applications to polymer materials
We demonstrate that single-pass Kelvin force microscopy (KFM) and capacitance gradient (dC/dZ) measurements with force gradient detection of tip–sample electrostatic interactions can be performed in the intermittent contact regime in different environments. Such combination provides sensitive detection of the surface potential and capacitance gradient with nanometer-scale spatial resolution as it was verified on self-assemblies of fluoroalkanes and a metal alloy. The KFM and dC/dZ applications to several heterogeneous polymer materials demonstrate the compositional mapping of these samples in dry and humid air as well as in organic vapors. In situ imaging in different environments facilitates recognition of the constituents of multi-component polymer systems due to selective swelling of components.
- 6 January 2011
- Published by Beilstein Institut in Beilstein Journal of Nanotechnology
- Vol. 2 (1) , 15-27
Open AccessSingle-pass Kelvin force microscopy and dC/dZ measurements in the intermittent contact: applications to polymer materials
We demonstrate that single-pass Kelvin force microscopy (KFM) and capacitance gradient (dC/dZ) measurements with force gradient detection of tip–sample electrostatic interactions can be performed in the intermittent contact regime in different environments. Such combination provides sensitive detection of the surface potential and capacitance gradient with nanometer-scale spatial resolution as it was verified on self-assemblies of fluoroalkanes and a metal alloy. The KFM and dC/dZ applications to several heterogeneous polymer materials demonstrate the compositional mapping of these samples in dry and humid air as well as in organic vapors. In situ imaging in different environments facilitates recognition of the constituents of multi-component polymer systems due to selective swelling of components.