Nilton Vivacqua-Gomes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nilton Vivacqua-Gomes has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Bruno Carvalho de Vasconcelos
Post-graduate Program in Dentistry, Faculty of Pharmacy, Dentistry and Nursing, Federal University of Ceará, Fortaleza, CE, Brazil
10 shared publications - Rodrigo Ricci Vivan
University of São Paulo
7 shared publications Marco Antonio Hungaro Duarte
Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Dentística, Endodontia e Materiais Odontológicos, Bauru, São Paulo, Brasil
4 shared publications- Marco Antonio Hungaro Duarte
University of São Paulo
4 shared publications Ricardo Affonso Bernardes
Associação Brasileira de Odontologia, Taguatinga, Distrito Federal, Brasil
4 shared publications- Alexandre Augusto Zaia
Universidade Estadual de Campinas, Brazil
3 shared publications
Latest Publications
- 27 February 2026
- Published by Caleo in European Endodontic Journal
- Vol. 11 (2) , 63-67
Evaluation of Ultrasonics, XP-Endo Finisher, and Easy Clean Activation Devices to Disinfect Root Canals Contaminated with Enterococcus faecalis
Objectives: The aim of this study was to analyse the disinfection of root canals contaminated with Enterococcus faecalis (E. faecalis) using different complementary activation devices post instrumentation. Methods: Sixty-two one-root human mandibular premolars were filled with a culture of E. faecalis, for 21 days. The specimens were prepared with Reciproc R25 files to a working length of 1 mm short of the apical foramen. Microbiological samples were collected with absorbent paper cones before and after preparation (S0 and S1, respectively). Afterward, the specimens were randomly divided into 3 experimental groups: Ultrasonics (US), XP-Endo Finisher (XP), and Easy Clean (EC). Each complementary device was kept at working length and was activated for 1 minute, followed by irrigation with 12 mL of saline. Microbiological samples (S2) were collected after activation with the devices US, XP, and EC. Data from the microbial reductions (in CFU × mL0-1) were submitted to the Kruskal–Wallis and 5% Dunn tests. Results: The root canal preparation with R25 instruments promoted a large microbial reduction in all groups (P < .05). The use of activation devices significantly reduced the amount of microorganisms (P < .05); however, there was no significant difference among activation devices. Conclusion: It was concluded that the use of complementary activation devices US, XP, and EC significantly improved the disinfection of the root canals when compared to conventional irrigation.
- 27 February 2026
- Published by Caleo in European Endodontic Journal
- Vol. 11 (2) , 63-67
Evaluation of Ultrasonics, XP-Endo Finisher, and Easy Clean Activation Devices to Disinfect Root Canals Contaminated with Enterococcus faecalis
Objectives: The aim of this study was to analyse the disinfection of root canals contaminated with Enterococcus faecalis (E. faecalis) using different complementary activation devices post instrumentation. Methods: Sixty-two one-root human mandibular premolars were filled with a culture of E. faecalis, for 21 days. The specimens were prepared with Reciproc R25 files to a working length of 1 mm short of the apical foramen. Microbiological samples were collected with absorbent paper cones before and after preparation (S0 and S1, respectively). Afterward, the specimens were randomly divided into 3 experimental groups: Ultrasonics (US), XP-Endo Finisher (XP), and Easy Clean (EC). Each complementary device was kept at working length and was activated for 1 minute, followed by irrigation with 12 mL of saline. Microbiological samples (S2) were collected after activation with the devices US, XP, and EC. Data from the microbial reductions (in CFU × mL0-1) were submitted to the Kruskal–Wallis and 5% Dunn tests. Results: The root canal preparation with R25 instruments promoted a large microbial reduction in all groups (P < .05). The use of activation devices significantly reduced the amount of microorganisms (P < .05); however, there was no significant difference among activation devices. Conclusion: It was concluded that the use of complementary activation devices US, XP, and EC significantly improved the disinfection of the root canals when compared to conventional irrigation.
- Open Access
- 16 January 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (2)
Influence of type of metal alloy and penetration limit in determining the working length with two apex locators
This ex vivo study aimed to evaluate the precision of two electronic foramen locators (Root ZX mini and RomiApex A15) inserting the manual Flexofile or NiTi endodontic files until reaching the apical foramen or surpassing it. Sixty mesial root canals of mandibular molars were selected. Root canal real length measurement and odontometry were performed after the access cavity surgery, cervical pre-flaring, and apical preparation. The precision of the electronic foramen locators was verified at each instrumentation phase, comparing the electronic measurements with the real length. The 3-way ANOVA test was used to evaluate the error of electronic measurements, and a significance level was set at 5%. At the first odontometry, the RZX was significantly more precise than the A15 (p<0,0001). After the second odontometry, the best results were observed when the penetration limit was restricted to the apical foramen. After the third odontometry, statistical differences were found for apex locator (p<0,0001), penetration limit (p<0,05), and metallic alloy (p=0,01). Manual instruments used to perform the odontometry should be inserted only until the foramen level. The use of NiTi files improves the precision of electronic foramen locators.
- 16 January 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (2)
Open AccessInfluence of type of metal alloy and penetration limit in determining the working length with two apex locators
This ex vivo study aimed to evaluate the precision of two electronic foramen locators (Root ZX mini and RomiApex A15) inserting the manual Flexofile or NiTi endodontic files until reaching the apical foramen or surpassing it. Sixty mesial root canals of mandibular molars were selected. Root canal real length measurement and odontometry were performed after the access cavity surgery, cervical pre-flaring, and apical preparation. The precision of the electronic foramen locators was verified at each instrumentation phase, comparing the electronic measurements with the real length. The 3-way ANOVA test was used to evaluate the error of electronic measurements, and a significance level was set at 5%. At the first odontometry, the RZX was significantly more precise than the A15 (p<0,0001). After the second odontometry, the best results were observed when the penetration limit was restricted to the apical foramen. After the third odontometry, statistical differences were found for apex locator (p<0,0001), penetration limit (p<0,05), and metallic alloy (p=0,01). Manual instruments used to perform the odontometry should be inserted only until the foramen level. The use of NiTi files improves the precision of electronic foramen locators.
- Open Access
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 36, e080
Root canal length changes during mechanical preparation due to different cervical enlargement patterns
This study aimed to evaluate the root canal real length (RL) changes due to the mechanical instrumentation use with different flaring magnitudes. After access cavity, 60 mesial root canals of mandibular molars were randomly separated in three groups: Hyflex EDM (HF; #25/.12, #10/.05 e #25/~), Reciproc Blue (RB; R25), and MTwo (M2; #10/.04, #15/.05, #20/.06 e #25/.06). The RL was defined as the apical limit, and 2.5% sodium hypochlorite irrigating solution was chosen. After the access cavity (RL 1), cervical flaring (RL 2), and complete chemical-mechanical preparation (RL 3), the RL was evaluated. The RL was evaluated by a blind examiner with the aid of a microscope (16x) placing the endodontic file stop at the coronary reference. When comparing length measurements, the RL was shorter before instrumentation than that after instrumentation. A reduction of 0.65 mm (HF), 0.61 mm (RB), and 0.48 mm (M2) was observed. However, among groups, no statistical differences were found (p > 0.05). Under the conditions tested, it can be inferred that all mechanical systems provoked RL variations, which emphasizes the need for constant verification of the odontometry, mainly before root canal obturation.
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 36, e080
Open AccessRoot canal length changes during mechanical preparation due to different cervical enlargement patterns
This study aimed to evaluate the root canal real length (RL) changes due to the mechanical instrumentation use with different flaring magnitudes. After access cavity, 60 mesial root canals of mandibular molars were randomly separated in three groups: Hyflex EDM (HF; #25/.12, #10/.05 e #25/~), Reciproc Blue (RB; R25), and MTwo (M2; #10/.04, #15/.05, #20/.06 e #25/.06). The RL was defined as the apical limit, and 2.5% sodium hypochlorite irrigating solution was chosen. After the access cavity (RL 1), cervical flaring (RL 2), and complete chemical-mechanical preparation (RL 3), the RL was evaluated. The RL was evaluated by a blind examiner with the aid of a microscope (16x) placing the endodontic file stop at the coronary reference. When comparing length measurements, the RL was shorter before instrumentation than that after instrumentation. A reduction of 0.65 mm (HF), 0.61 mm (RB), and 0.48 mm (M2) was observed. However, among groups, no statistical differences were found (p > 0.05). Under the conditions tested, it can be inferred that all mechanical systems provoked RL variations, which emphasizes the need for constant verification of the odontometry, mainly before root canal obturation.
- Open Access
- 3 July 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (8)
Compliance of RCTs in endodontic instrumentation with the CONSORT Statement: A systematic review
This systematic review aimed to evaluate the adherence to the CONSORT Statement in clinical studies comparing different instrumentation techniques in Endodontics. Methodology: A systematic search was carried out through Medline databases. There was no restriction on publication year or idiom. Solely randomized controlled trials (RCTs) were included. The articles were evaluated in compliance with CONSORT. Descriptive analyses of the number of studies by journal, country, and quality assessments were performed with RoB 2.0 Cochrane Collaboration’s tool for assessing risk of bias in RCTs. A total of 6779 studies were identified, and only 33 meet the eligibility criteria. In relation to the overall risk of bias, eight out of 33 were classified as at ‘low’ risk of bias. The overall CONSORT score for the included studies in this review was 22 ± 6.2 points. Significant differences among countries were observed (p = 0.03). The range of years had a significant influence on the average CONSORT score (p = 0.01). The adherence of RCTs of endodontic instrumentation to the CONSORT Statement requires improvements. Adherence to the CONSORT statement will also reduce the high or some concerns risk of bias of studies in the field. CRD42020160552
- 3 July 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (8)
Open AccessCompliance of RCTs in endodontic instrumentation with the CONSORT Statement: A systematic review
This systematic review aimed to evaluate the adherence to the CONSORT Statement in clinical studies comparing different instrumentation techniques in Endodontics. Methodology: A systematic search was carried out through Medline databases. There was no restriction on publication year or idiom. Solely randomized controlled trials (RCTs) were included. The articles were evaluated in compliance with CONSORT. Descriptive analyses of the number of studies by journal, country, and quality assessments were performed with RoB 2.0 Cochrane Collaboration’s tool for assessing risk of bias in RCTs. A total of 6779 studies were identified, and only 33 meet the eligibility criteria. In relation to the overall risk of bias, eight out of 33 were classified as at ‘low’ risk of bias. The overall CONSORT score for the included studies in this review was 22 ± 6.2 points. Significant differences among countries were observed (p = 0.03). The range of years had a significant influence on the average CONSORT score (p = 0.01). The adherence of RCTs of endodontic instrumentation to the CONSORT Statement requires improvements. Adherence to the CONSORT statement will also reduce the high or some concerns risk of bias of studies in the field. CRD42020160552
- Open Access
- 1 August 2020
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 31 (4) , 404-408
Influence of Different Coronal Preflaring Protocols on Electronic Foramen Locators Precision
The aim of this study was to evaluate the influence of different coronal preflaring protocols (absent, conservative and conventional) on the accuracy of Root ZX II, Raypex 6, and RomiApex A-15 electronic foramen locators (EFLs). Twenty mandibular molars with Vertucci’s type IV mesial roots were subjected to endodontic exploration and foraminal patency confirmation. Under 16x magnification, its real lengths (RL) were measured and registered (RL1). The canals were then irrigated with 2.5% sodium hypochlorite and electronically measured (EM1) employing the alginate model; all measurements were performed in triplicate by a blind operator using adjusted endodontic hand-files introduced until the apex foramen. Coronal preflaring procedures were sequentially performed with #25/.06 (conservative) and #25/.12 (conventional) instruments; new RLs extents were performed after each coronal preparation protocol (RL2/RL3), as same as electronic measurements (EM2/EM3). The devices error (mm) was evaluated considering the difference between RLs and EMs at each preparation stage; their precision was stablished adopting ±0.5 mm as tolerance margin. The EFLs error significantly reduced after conventional coronal preflaring protocol (p0.05). Under the conditions tested it can be concluded that the EFLs evaluated were precise. Moreover, the preflaring protocols influences its accuracy’s, where the less conservative one produced the best results.
- 1 August 2020
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 31 (4) , 404-408
Open AccessInfluence of Different Coronal Preflaring Protocols on Electronic Foramen Locators Precision
The aim of this study was to evaluate the influence of different coronal preflaring protocols (absent, conservative and conventional) on the accuracy of Root ZX II, Raypex 6, and RomiApex A-15 electronic foramen locators (EFLs). Twenty mandibular molars with Vertucci’s type IV mesial roots were subjected to endodontic exploration and foraminal patency confirmation. Under 16x magnification, its real lengths (RL) were measured and registered (RL1). The canals were then irrigated with 2.5% sodium hypochlorite and electronically measured (EM1) employing the alginate model; all measurements were performed in triplicate by a blind operator using adjusted endodontic hand-files introduced until the apex foramen. Coronal preflaring procedures were sequentially performed with #25/.06 (conservative) and #25/.12 (conventional) instruments; new RLs extents were performed after each coronal preparation protocol (RL2/RL3), as same as electronic measurements (EM2/EM3). The devices error (mm) was evaluated considering the difference between RLs and EMs at each preparation stage; their precision was stablished adopting ±0.5 mm as tolerance margin. The EFLs error significantly reduced after conventional coronal preflaring protocol (p0.05). Under the conditions tested it can be concluded that the EFLs evaluated were precise. Moreover, the preflaring protocols influences its accuracy’s, where the less conservative one produced the best results.
- Open Access
- 18 January 2018
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 26, e20170215
Debris extrusion and foraminal deformation produced by reciprocating instruments made of thermally treated NiTi wires
Keywords Endodontics; Nickel; Titanium; Root canal preparation
- 18 January 2018
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 26, e20170215
Open AccessDebris extrusion and foraminal deformation produced by reciprocating instruments made of thermally treated NiTi wires
Keywords Endodontics; Nickel; Titanium; Root canal preparation
- 27 November 2017
- Published by Wiley in International Endodontic Journal
- Vol. 51 (6) , 705-713
Evaluation of apical transportation and centring ability of five thermally treated NiTi rotary systems
Aim: To evaluate apical transportation and centring ability during root canal preparation in mesial root canals of mandibular molars associated with ProTaper Gold (PTG), ProDesign S (PDS), Hyflex CM (HCM), Hyflex EDM and ProDesign Logic (PDL).Methodology: Sixty mandibular first molars with two separate canals in the mesial root were selected after root anatomy pairing by microcomputed tomography (microCT). The teeth were randomly divided into five groups (n = 24); the root canal volume was calculated to ensure sample homogeneity. All the root canals were prepared up to size 25 in accordance with the instructions of each rotary system manufacturer. After root canal preparation, the teeth were scanned by microCT to analyse apical transportation, root canal centralization and the pre‐ and post‐preparation root canal volume at the apical and cervical levels. Kruskal–Wallis and Dunn tests were used for comparisons amongst groups for transportation values. For volume changes, the parametric ANOVA and Tukey’s tests were usedResults: There were no significant differences in apical transportation amongst the rotary systems (P > 0.05). All the systems created apical transportation; values ranging from 0.031 mm (PDL) to 0.072 mm (PTG), and enlargements between 39% (HCM) and 91.1% (PDS) were observed. In relative to cervical transportation, significant differences were observed amongst the systems (P < 0.05). Mean transportation values between 0.07 mm (HCM) and 0.172 mm (PTG) were found, with enlargements between 35.4% (HCM) and 51.5% (PDS).Conclusion: All the thermally treated systems resulted in similar apical transportation. In the cervical region, the Hyflex CM and Prodesign Logic systems were associated with more centred preparations.
- 27 November 2017
- Published by Wiley in International Endodontic Journal
- Vol. 51 (6) , 705-713
Evaluation of apical transportation and centring ability of five thermally treated NiTi rotary systems
Aim: To evaluate apical transportation and centring ability during root canal preparation in mesial root canals of mandibular molars associated with ProTaper Gold (PTG), ProDesign S (PDS), Hyflex CM (HCM), Hyflex EDM and ProDesign Logic (PDL).Methodology: Sixty mandibular first molars with two separate canals in the mesial root were selected after root anatomy pairing by microcomputed tomography (microCT). The teeth were randomly divided into five groups (n = 24); the root canal volume was calculated to ensure sample homogeneity. All the root canals were prepared up to size 25 in accordance with the instructions of each rotary system manufacturer. After root canal preparation, the teeth were scanned by microCT to analyse apical transportation, root canal centralization and the pre‐ and post‐preparation root canal volume at the apical and cervical levels. Kruskal–Wallis and Dunn tests were used for comparisons amongst groups for transportation values. For volume changes, the parametric ANOVA and Tukey’s tests were usedResults: There were no significant differences in apical transportation amongst the rotary systems (P > 0.05). All the systems created apical transportation; values ranging from 0.031 mm (PDL) to 0.072 mm (PTG), and enlargements between 39% (HCM) and 91.1% (PDS) were observed. In relative to cervical transportation, significant differences were observed amongst the systems (P < 0.05). Mean transportation values between 0.07 mm (HCM) and 0.172 mm (PTG) were found, with enlargements between 35.4% (HCM) and 51.5% (PDS).Conclusion: All the thermally treated systems resulted in similar apical transportation. In the cervical region, the Hyflex CM and Prodesign Logic systems were associated with more centred preparations.
- 1 October 2017
- Published by Elsevier in Journal of Endodontics
- Vol. 43 (10) , 1663-1667
Determination of the Accuracy of 5 Electronic Apex Locators in the Function of Different Employment Protocols
- 1 October 2017
- Published by Elsevier in Journal of Endodontics
- Vol. 43 (10) , 1663-1667
Determination of the Accuracy of 5 Electronic Apex Locators in the Function of Different Employment Protocols
- 1 November 2016
- Published by Elsevier in Journal of Endodontics
- Vol. 42 (11) , 1683-1686
Changes in Root Canal Length Determined during Mechanical Preparation Stages and Their Relationship with the Accuracy of Root ZX II
- 1 November 2016
- Published by Elsevier in Journal of Endodontics
- Vol. 42 (11) , 1683-1686
Changes in Root Canal Length Determined during Mechanical Preparation Stages and Their Relationship with the Accuracy of Root ZX II
- 1 January 2016
- Published by Elsevier in Journal of Endodontics
- Vol. 42 (1) , 8-11
The Effect of Foraminal Enlargement of Necrotic Teeth with the Reciproc System on Postoperative Pain: A Prospective and Randomized Clinical Trial
- 1 January 2016
- Published by Elsevier in Journal of Endodontics
- Vol. 42 (1) , 8-11
The Effect of Foraminal Enlargement of Necrotic Teeth with the Reciproc System on Postoperative Pain: A Prospective and Randomized Clinical Trial