Brandon S. Nichols
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Brandon S. Nichols has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- James William Tunnell
The University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas, United States
6 shared publications - Narasimhan Rajaram
Department of Biomedical Engineering, University of Arkansas, Fayetteville, AR 72701, USA
5 shared publications - Nirmala Ramanujam
Center for Global Women’s Health Technologies, Duke University, Durham, USA
3 shared publications - Gregory M. Palmer
Department of Radiation Oncology, Duke University , Durham, NC 27708
2 shared publications Joseph Geradts
Duke University Medical Center, Department of Pathology, Durham, North Carolina, United States
2 shared publicationsLiang Lim
University of Texas at Austin, Department of Biomedical Engineering, 107 W. Dean Keeton Street C0800, Austin, Texas 78712, United States
2 shared publications
Latest Publications
- Open Access
- 1 February 2017
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 22 (2) , 026007
Miniature spectral imaging device for wide-field quantitative functional imaging of the morphological landscape of breast tumor margins
We have developed a portable, breast margin assessment probe leveraging diffuse optical spectroscopy to quantify the morphological landscape of breast tumor margins during breast conserving surgery. The approach presented here leverages a custom-made 16-channel annular photodiode imaging array (arranged in a grid), a raster-scanning imaging platform with precision pressure control, and compressive sensing with an optimized set of eight wavelengths in the visible spectral range. A scalable Monte-Carlo-based inverse model is used to generate optical property [ and ] measures for each of the 16 simultaneously captured diffuse reflectance spectra. Subpixel sampling (0.75 mm) is achieved through incremental , raster scanning of the imaging probe, providing detailed optical parameter maps of breast margins over a area in . The morphological landscape of a tumor margin is characterized using optical surrogates for the fat to fibroglandular content ratio, which has demonstrated diagnostic utility in delineating tissue subtypes in the breast.- 1 February 2017
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 22 (2) , 026007
Open AccessMiniature spectral imaging device for wide-field quantitative functional imaging of the morphological landscape of breast tumor margins
We have developed a portable, breast margin assessment probe leveraging diffuse optical spectroscopy to quantify the morphological landscape of breast tumor margins during breast conserving surgery. The approach presented here leverages a custom-made 16-channel annular photodiode imaging array (arranged in a grid), a raster-scanning imaging platform with precision pressure control, and compressive sensing with an optimized set of eight wavelengths in the visible spectral range. A scalable Monte-Carlo-based inverse model is used to generate optical property [ and ] measures for each of the 16 simultaneously captured diffuse reflectance spectra. Subpixel sampling (0.75 mm) is achieved through incremental , raster scanning of the imaging probe, providing detailed optical parameter maps of breast margins over a area in . The morphological landscape of a tumor margin is characterized using optical surrogates for the fat to fibroglandular content ratio, which has demonstrated diagnostic utility in delineating tissue subtypes in the breast. - 1 January 2016
- Published by Optica Publishing Group
- p. TM4B.6
Portable System for Wide-field, Sub-millimeter Functional Imaging of the Morphological Landscape of Breast Tumor Margins
High-resolution reflectance-derived optical parameter maps of the ratio of the β-carotene concentration to the reduced scattering coefficient can be used to rapidly survey tissue morphology for large tissue areas on intra-operative time scales.
- 1 January 2016
- Published by Optica Publishing Group
- p. TM4B.6
Portable System for Wide-field, Sub-millimeter Functional Imaging of the Morphological Landscape of Breast Tumor Margins
High-resolution reflectance-derived optical parameter maps of the ratio of the β-carotene concentration to the reduced scattering coefficient can be used to rapidly survey tissue morphology for large tissue areas on intra-operative time scales.
- Open Access
- 15 June 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (6) , e0127525
A Quantitative Diffuse Reflectance Imaging (QDRI) System for Comprehensive Surveillance of the Morphological Landscape in Breast Tumor Margins
In an ongoing effort to address the clear clinical unmet needs surrounding breast conserving surgery (BCS), our group has developed a next-generation multiplexed optical-fiber-based tool to assess breast tumor margin status during initial surgeries. Specifically detailed in this work is the performance and clinical validation of a research-grade intra-operative tool for margin assessment based on diffuse optical spectroscopy. Previous work published by our group has illustrated the proof-of-concept generations of this device; here we incorporate a highly optimized quantitative diffuse reflectance imaging (QDRI) system utilizing a wide-field (imaging area = 17cm2) 49-channel multiplexed fiber optic probe, a custom raster-scanning imaging platform, a custom dual-channel white LED source, and an astronomy grade imaging CCD and spectrograph. The system signal to noise ratio (SNR) was found to be greater than 40dB for all channels. Optical property estimation error was found to be less than 10%, on average, over a wide range of absorption (μa = 0–8.9cm-1) and scattering (μs’ = 7.0–9.7cm-1) coefficients. Very low inter-channel and CCD crosstalk was observed (2% max) when used on turbid media (including breast tissue). A raster-scanning mechanism was developed to achieve sub-pixel resolution and was found to be optimally performed at an upsample factor of 8, affording 0.75mm spatially resolved diffuse reflectance images (λ = 450–600nm) of an entire margin (area = 17cm2) in 13.8 minutes (1.23cm2/min). Moreover, controlled pressure application at the probe-tissue interface afforded by the imaging platform reduces repeated scan variability, providing <1% variation across repeated scans of clinical specimens. We demonstrate the clinical utility of this device through a pilot 20-patient study of high-resolution optical parameter maps of the ratio of the β-carotene concentration to the reduced scattering coefficient. An empirical cumulative distribution function (eCDF) analysis is used to reduce optical property maps to quantitative distributions representing the morphological landscape of breast tumor margins. The optimizations presented in this work provide an avenue to rapidly survey large tissue areas on intra-operative time scales with improved sensitivity to regions of focal disease that may otherwise be overlooked.
- 15 June 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (6) , e0127525
Open AccessA Quantitative Diffuse Reflectance Imaging (QDRI) System for Comprehensive Surveillance of the Morphological Landscape in Breast Tumor Margins
In an ongoing effort to address the clear clinical unmet needs surrounding breast conserving surgery (BCS), our group has developed a next-generation multiplexed optical-fiber-based tool to assess breast tumor margin status during initial surgeries. Specifically detailed in this work is the performance and clinical validation of a research-grade intra-operative tool for margin assessment based on diffuse optical spectroscopy. Previous work published by our group has illustrated the proof-of-concept generations of this device; here we incorporate a highly optimized quantitative diffuse reflectance imaging (QDRI) system utilizing a wide-field (imaging area = 17cm2) 49-channel multiplexed fiber optic probe, a custom raster-scanning imaging platform, a custom dual-channel white LED source, and an astronomy grade imaging CCD and spectrograph. The system signal to noise ratio (SNR) was found to be greater than 40dB for all channels. Optical property estimation error was found to be less than 10%, on average, over a wide range of absorption (μa = 0–8.9cm-1) and scattering (μs’ = 7.0–9.7cm-1) coefficients. Very low inter-channel and CCD crosstalk was observed (2% max) when used on turbid media (including breast tissue). A raster-scanning mechanism was developed to achieve sub-pixel resolution and was found to be optimally performed at an upsample factor of 8, affording 0.75mm spatially resolved diffuse reflectance images (λ = 450–600nm) of an entire margin (area = 17cm2) in 13.8 minutes (1.23cm2/min). Moreover, controlled pressure application at the probe-tissue interface afforded by the imaging platform reduces repeated scan variability, providing <1% variation across repeated scans of clinical specimens. We demonstrate the clinical utility of this device through a pilot 20-patient study of high-resolution optical parameter maps of the ratio of the β-carotene concentration to the reduced scattering coefficient. An empirical cumulative distribution function (eCDF) analysis is used to reduce optical property maps to quantitative distributions representing the morphological landscape of breast tumor margins. The optimizations presented in this work provide an avenue to rapidly survey large tissue areas on intra-operative time scales with improved sensitivity to regions of focal disease that may otherwise be overlooked.
- Open Access
- 1 November 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 19 (11) , 117003
Clinical study of noninvasivein vivomelanoma and nonmelanoma skin cancers using multimodal spectral diagnosis
The goal of this study was to determine the diagnostic capability of a multimodal spectral diagnosis (SD) for in vivo noninvasive disease diagnosis of melanoma and nonmelanoma skin cancers. We acquired reflectance, fluorescence, and Raman spectra from 137 lesions in 76 patients using custom-built optical fiber-based clinical systems. Biopsies of lesions were classified using standard histopathology as malignant melanoma (MM), nonmelanoma pigmented lesion (PL), basal cell carcinoma (BCC), actinic keratosis (AK), and squamous cell carcinoma (SCC). Spectral data were analyzed using principal component analysis. Using multiple diagnostically relevant principal components, we built leave-one-out logistic regression classifiers. Classification results were compared with histopathology of the lesion. Sensitivity/specificity for classifying MM versus PL (12 versus 17 lesions) was 100%/100%, for SCC and BCC versus AK (57 versus 14 lesions) was 95%/71%, and for AK and SCC and BCC versus normal skin (71 versus 71 lesions) was 90%/85%. The best classification for nonmelanoma skin cancers required multiple modalities; however, the best melanoma classification occurred with Raman spectroscopy alone. The high diagnostic accuracy for classifying both melanoma and nonmelanoma skin cancer lesions demonstrates the potential for SD as a clinical diagnostic device.
- 1 November 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 19 (11) , 117003
Open AccessClinical study of noninvasivein vivomelanoma and nonmelanoma skin cancers using multimodal spectral diagnosis
The goal of this study was to determine the diagnostic capability of a multimodal spectral diagnosis (SD) for in vivo noninvasive disease diagnosis of melanoma and nonmelanoma skin cancers. We acquired reflectance, fluorescence, and Raman spectra from 137 lesions in 76 patients using custom-built optical fiber-based clinical systems. Biopsies of lesions were classified using standard histopathology as malignant melanoma (MM), nonmelanoma pigmented lesion (PL), basal cell carcinoma (BCC), actinic keratosis (AK), and squamous cell carcinoma (SCC). Spectral data were analyzed using principal component analysis. Using multiple diagnostically relevant principal components, we built leave-one-out logistic regression classifiers. Classification results were compared with histopathology of the lesion. Sensitivity/specificity for classifying MM versus PL (12 versus 17 lesions) was 100%/100%, for SCC and BCC versus AK (57 versus 14 lesions) was 95%/71%, and for AK and SCC and BCC versus normal skin (71 versus 71 lesions) was 90%/85%. The best classification for nonmelanoma skin cancers required multiple modalities; however, the best melanoma classification occurred with Raman spectroscopy alone. The high diagnostic accuracy for classifying both melanoma and nonmelanoma skin cancer lesions demonstrates the potential for SD as a clinical diagnostic device.
- Open Access
- 8 November 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (12) , 3211-3222
A diffuse reflectance spectral imaging system for tumor margin assessment using custom annular photodiode arrays
Diffuse reflectance spectroscopy (DRS) is a well-established method to quantitatively distinguish between benign and cancerous tissue for tumor margin assessment. Current multipixel DRS margin assessment tools are bulky fiber-based probes that have limited scalability. Reported herein is a new approach to multipixel DRS probe design, which utilizes direct detection of the DRS signal by using optimized custom photodetectors in direct contact with the tissue. This first fiberless DRS imaging system for tumor margin assessment consists of a 4 × 4 array of annular silicon photodetectors and a constrained free-space light delivery tube optimized to deliver light across a 256 mm2 imaging area. This system has 4.5 mm spatial resolution. The signal-to-noise ratio measured for normal and malignant breast tissue-mimicking phantoms was 35 dB to 45 dB for λ = 470 nm to 600 nm.
- 8 November 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (12) , 3211-3222
Open AccessA diffuse reflectance spectral imaging system for tumor margin assessment using custom annular photodiode arrays
Diffuse reflectance spectroscopy (DRS) is a well-established method to quantitatively distinguish between benign and cancerous tissue for tumor margin assessment. Current multipixel DRS margin assessment tools are bulky fiber-based probes that have limited scalability. Reported herein is a new approach to multipixel DRS probe design, which utilizes direct detection of the DRS signal by using optimized custom photodetectors in direct contact with the tissue. This first fiberless DRS imaging system for tumor margin assessment consists of a 4 × 4 array of annular silicon photodetectors and a constrained free-space light delivery tube optimized to deliver light across a 256 mm2 imaging area. This system has 4.5 mm spatial resolution. The signal-to-noise ratio measured for normal and malignant breast tissue-mimicking phantoms was 35 dB to 45 dB for λ = 470 nm to 600 nm.
- Open Access
- 20 April 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (5) , 0570011-0570018
Performance of a lookup table-based approach for measuring tissue optical properties with diffuse optical spectroscopy
Diffuse optical spectroscopy (DOS) provides a powerful tool for fast and noninvasive disease diagnosis. The ability to leverage DOS to accurately quantify tissue optical parameters hinges on the model used to estimate light-tissue interaction. We describe the accuracy of a lookup table (LUT)-based inverse model for measuring optical properties under different conditions relevant to biological tissue. The LUT is a matrix of reflectance values acquired experimentally from calibration standards of varying scattering and absorption properties. Because it is based on experimental values, the LUT inherently accounts for system response and probe geometry. We tested our approach in tissue phantoms containing multiple absorbers, different sizes of scatterers, and varying oxygen saturation of hemoglobin. The LUT-based model was able to extract scattering and absorption properties under most conditions with errors of less than 5 percent. We demonstrate the validity of the lookup table over a range of source-detector separations from 0.25 to 1.48 mm. Finally, we describe the rapid fabrication of a lookup table using only six calibration standards. This optimized LUT was able to extract scattering and absorption properties with average RMS errors of 2.5 and 4 percent, respectively.
- 20 April 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (5) , 0570011-0570018
Open AccessPerformance of a lookup table-based approach for measuring tissue optical properties with diffuse optical spectroscopy
Diffuse optical spectroscopy (DOS) provides a powerful tool for fast and noninvasive disease diagnosis. The ability to leverage DOS to accurately quantify tissue optical parameters hinges on the model used to estimate light-tissue interaction. We describe the accuracy of a lookup table (LUT)-based inverse model for measuring optical properties under different conditions relevant to biological tissue. The LUT is a matrix of reflectance values acquired experimentally from calibration standards of varying scattering and absorption properties. Because it is based on experimental values, the LUT inherently accounts for system response and probe geometry. We tested our approach in tissue phantoms containing multiple absorbers, different sizes of scatterers, and varying oxygen saturation of hemoglobin. The LUT-based model was able to extract scattering and absorption properties under most conditions with errors of less than 5 percent. We demonstrate the validity of the lookup table over a range of source-detector separations from 0.25 to 1.48 mm. Finally, we describe the rapid fabrication of a lookup table using only six calibration standards. This optimized LUT was able to extract scattering and absorption properties with average RMS errors of 2.5 and 4 percent, respectively.
- 14 March 2012
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 44 (4) , 303-309
Effects of mechanical indentation on diffuse reflectance spectra, light transmission, and intrinsic optical properties in ex vivo porcine skin
Background and Objectives: Mechanical indentation has been shown to increase light transmission through turbid tissue. In this study, we investigated the effects of localized indentation on the optical properties of ex vivo porcine skin specimens by dynamically monitoring diffuse reflectance spectra, light transmission, and applied load while controlling tissue thickness.Study Design/Methods: A custom‐built diffuse reflectance spectroscopy (DRS) system was used to capture diffuse reflectance spectra from tissue specimens undergoing indentation. The DRS probe was designed to perform both optical sensing and tissue indentation. A mechanical load frame was used to dynamically control probe displacement and resultant specimen thickness change while recording applied load. Diffuse reflectance spectra, as well as light transmission at 630 nm, were recorded during stress relaxation tests where tissue specimens were displaced to and held at a final thickness. Tissue optical properties were extracted from reflectance spectra using a previously established look‐up table (LUT) approach.Results: Indentation increased light transmission through tissue during linear displacement, and continued to increase transmission during subsequent stress relaxation at constant tissue thickness. The magnitude of relative transmission increases was shown to be a function of bulk tissue compressive strain (relative thickness change). Reduced scattering coefficients calculated from the LUT at 630 nm decreased during stress relaxation, with the relative decrease in scattering also depending strongly on tissue compressive strain. Reduced scattering coefficients decreased by 12.0 ± 4.7% at 0.44 ± 0.022 compressive strain, and reduced by 35.6 ± 1.3% at 0.71 ± 0.01 compressive strain.Conclusion: DRS can be used to capture transient changes in intrinsic tissue optical properties during mechanical loading. Mechanical indentation modifies tissue optical properties and may be harnessed as a minimally‐invasive optical clearing technique to improve optical diagnostics and therapeutics. Lasers Surg. Med. 44:303–309, 2012.
- 14 March 2012
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 44 (4) , 303-309
Effects of mechanical indentation on diffuse reflectance spectra, light transmission, and intrinsic optical properties in ex vivo porcine skin
Background and Objectives: Mechanical indentation has been shown to increase light transmission through turbid tissue. In this study, we investigated the effects of localized indentation on the optical properties of ex vivo porcine skin specimens by dynamically monitoring diffuse reflectance spectra, light transmission, and applied load while controlling tissue thickness.Study Design/Methods: A custom‐built diffuse reflectance spectroscopy (DRS) system was used to capture diffuse reflectance spectra from tissue specimens undergoing indentation. The DRS probe was designed to perform both optical sensing and tissue indentation. A mechanical load frame was used to dynamically control probe displacement and resultant specimen thickness change while recording applied load. Diffuse reflectance spectra, as well as light transmission at 630 nm, were recorded during stress relaxation tests where tissue specimens were displaced to and held at a final thickness. Tissue optical properties were extracted from reflectance spectra using a previously established look‐up table (LUT) approach.Results: Indentation increased light transmission through tissue during linear displacement, and continued to increase transmission during subsequent stress relaxation at constant tissue thickness. The magnitude of relative transmission increases was shown to be a function of bulk tissue compressive strain (relative thickness change). Reduced scattering coefficients calculated from the LUT at 630 nm decreased during stress relaxation, with the relative decrease in scattering also depending strongly on tissue compressive strain. Reduced scattering coefficients decreased by 12.0 ± 4.7% at 0.44 ± 0.022 compressive strain, and reduced by 35.6 ± 1.3% at 0.71 ± 0.01 compressive strain.Conclusion: DRS can be used to capture transient changes in intrinsic tissue optical properties during mechanical loading. Mechanical indentation modifies tissue optical properties and may be harnessed as a minimally‐invasive optical clearing technique to improve optical diagnostics and therapeutics. Lasers Surg. Med. 44:303–309, 2012.
- Open Access
- 1 December 2011
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (12) , 120505-4
Development of a noncontact diffuse optical spectroscopy probe for measuring tissue optical properties
Diffuse optical spectroscopy (DOS) provides a sensitive means to measure the absorption and scattering properties of biological tissues and has been used to diagnose and monitor disease in a number of clinical situations including breast cancer,1 ovarian cancer,2 Barrett's esophagus,3 lung cancer,4 cervical cancer,5 and skin cancer.6 The instrumentation for DOS typically uses a combination of optical fiber probes to deliver and collect light from the tissue surface. The application of a standard optical fiber probe requires applied pressure in order to make contact with the tissue, which has been shown to introduce errors in the extracted optical properties.7 In addition, the distal end of a contact probe can obscure the exact measurement location on the tissue surface. In this paper, we report the development of a handheld noncontact DOS device that removes the effects of probe pressure and documents the measurement site by imaging the distal end of a standard contact fiber probe onto the tissue with lenses. To mitigate the effects of specular reflection and limited depth of focus, we used cross polarization and a custom autofocus mechanism, respectively. We demonstrate the quantitative performance of this device with tissue simulating phantoms and demonstrate its use in measuring the optical properties of human tissue.
- 1 December 2011
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (12) , 120505-4
Open AccessDevelopment of a noncontact diffuse optical spectroscopy probe for measuring tissue optical properties
Diffuse optical spectroscopy (DOS) provides a sensitive means to measure the absorption and scattering properties of biological tissues and has been used to diagnose and monitor disease in a number of clinical situations including breast cancer,1 ovarian cancer,2 Barrett's esophagus,3 lung cancer,4 cervical cancer,5 and skin cancer.6 The instrumentation for DOS typically uses a combination of optical fiber probes to deliver and collect light from the tissue surface. The application of a standard optical fiber probe requires applied pressure in order to make contact with the tissue, which has been shown to introduce errors in the extracted optical properties.7 In addition, the distal end of a contact probe can obscure the exact measurement location on the tissue surface. In this paper, we report the development of a handheld noncontact DOS device that removes the effects of probe pressure and documents the measurement site by imaging the distal end of a standard contact fiber probe onto the tissue with lenses. To mitigate the effects of specular reflection and limited depth of focus, we used cross polarization and a custom autofocus mechanism, respectively. We demonstrate the quantitative performance of this device with tissue simulating phantoms and demonstrate its use in measuring the optical properties of human tissue.
- 1 January 2011
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (7) , 077008-077008-14
Changes in morphology and optical properties of sclera and choroidal layers due to hyperosmotic agent
Light scattering in the normally white sclera prevents diagnostic imaging or delivery of a focused laser beam to a target in the underlying choroid layer. In this study, we examine optical clearing of the sclera and changes in blood flow resulting from the application of glycerol to the sclera of rabbits. Recovery dynamics are monitored after the application of saline. The speed of clearing for injection delivery is compared to the direct application of glycerol through an incision in the conjunctiva. Although, the same volume of glycerol was applied, the sclera cleared much faster (5 to 10 s) with the topical application of glycerol compared to the injection method (3 min). In addition, the direct topical application of glycerol spreads over a larger area in the sclera than the latter method. A diffuse optical spectroscopy system provided spectral analysis of the remitted light every two minutes during clearing and rehydration. Comparison of measurements to those obtained from phantoms with various absorption and scattering properties provided estimates of the absorption coefficient and reduced scattering coefficient of rabbit eye tissue.
- 1 January 2011
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (7) , 077008-077008-14
Changes in morphology and optical properties of sclera and choroidal layers due to hyperosmotic agent
Light scattering in the normally white sclera prevents diagnostic imaging or delivery of a focused laser beam to a target in the underlying choroid layer. In this study, we examine optical clearing of the sclera and changes in blood flow resulting from the application of glycerol to the sclera of rabbits. Recovery dynamics are monitored after the application of saline. The speed of clearing for injection delivery is compared to the direct application of glycerol through an incision in the conjunctiva. Although, the same volume of glycerol was applied, the sclera cleared much faster (5 to 10 s) with the topical application of glycerol compared to the injection method (3 min). In addition, the direct topical application of glycerol spreads over a larger area in the sclera than the latter method. A diffuse optical spectroscopy system provided spectral analysis of the remitted light every two minutes during clearing and rehydration. Comparison of measurements to those obtained from phantoms with various absorption and scattering properties provided estimates of the absorption coefficient and reduced scattering coefficient of rabbit eye tissue.
- Open Access
- 1 January 2011
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (1) , 011012-011012-9
Probe pressure effects on human skin diffuse reflectance and fluorescence spectroscopy measurements
Diffuse reflectance and fluorescence spectroscopy are popular research techniques for noninvasive disease diagnostics. Most systems include an optical fiber probe that transmits and collects optical spectra in contact with the suspected lesion. The purpose of this study is to investigate probe pressure effects on human skin spectroscopic measurements. We conduct an in-vivo experiment on human skin tissue to study the short-term (30 s) effects of probe pressure on diffuse reflectance and fluorescence measurements. Short-term light probe pressure (P0 < 9 mN/mm2) effects are within 0 ± 10% on all physiological properties extracted from diffuse reflectance and fluorescence measurements, and less than 0 ± 5% for diagnostically significant physiological properties. Absorption decreases with site-specific variations due to blood being compressed out of the sampled volume. Reduced scattering coefficient variation is site specific. Intrinsic fluorescence shows a large standard error, although no specific pressure-related trend is observed. Differences in tissue structure and morphology contribute to site-specific probe pressure effects. Therefore, the effects of pressure can be minimized when the pressure is small and applied for a short amount of time; however, long-term and large pressures induce significant distortions in measured spectra.
- 1 January 2011
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (1) , 011012-011012-9
Open AccessProbe pressure effects on human skin diffuse reflectance and fluorescence spectroscopy measurements
Diffuse reflectance and fluorescence spectroscopy are popular research techniques for noninvasive disease diagnostics. Most systems include an optical fiber probe that transmits and collects optical spectra in contact with the suspected lesion. The purpose of this study is to investigate probe pressure effects on human skin spectroscopic measurements. We conduct an in-vivo experiment on human skin tissue to study the short-term (30 s) effects of probe pressure on diffuse reflectance and fluorescence measurements. Short-term light probe pressure (P0 < 9 mN/mm2) effects are within 0 ± 10% on all physiological properties extracted from diffuse reflectance and fluorescence measurements, and less than 0 ± 5% for diagnostically significant physiological properties. Absorption decreases with site-specific variations due to blood being compressed out of the sampled volume. Reduced scattering coefficient variation is site specific. Intrinsic fluorescence shows a large standard error, although no specific pressure-related trend is observed. Differences in tissue structure and morphology contribute to site-specific probe pressure effects. Therefore, the effects of pressure can be minimized when the pressure is small and applied for a short amount of time; however, long-term and large pressures induce significant distortions in measured spectra.