RRRajni Rajan

Rajni Rajan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rajni Rajan has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Does Occupation Influence Selection of Contact Lens Material?

    by Rajni M.Phil. Optom. Rajan, Rajeswari Ph.D. Mahadevan, Pradipta M.Phil. Optom. Bhattacharya

    Objective: Long-term follow-up of contact lens (CL) wearers leads to better understanding of the factors leading to changes in CL trends. This study is an attempt to ascertain these factors in an emerging market like India. Factors like occupation were analyzed to determine if these contributed to changes in selection of CL materials in this article. Methods: Occupations were categorized as per the norms of International Standard Classification of Occupations-2008 (International Labor Organization, United Nations organization). Results: A majority of lens wearers were professionals and hydrogel lens materials were the lenses of choice among most of the lens wearers. There was a significant variation in CL material with different occupations (χ2=19.29, P=0.037). Conclusion: To conclude, employment and affordability influenced the selection of lens materials.


  • Contact lens trends over three decades in a hospital‐based practice in India

    by Rajni Rajan, Rajeswari Mahadevan, Ann Mary Thomas, Pradipta Bhattacharjee

    Contact lens fittings in a hospital-based practice are different from those in private practices because of specialised conditions. Few studies have been published on material preferences of such wearers, especially in long-term wearers. The aim of this study is to document contact lens prescribing trends in a hospital-based practice among long-term lens wearers and to identify their demographic profile. Subjects reporting to a contact lens clinic of a tertiary eye-care centre in India from 1 January 2014 to 31 December 2014, with a minimum of five years of lens wear, were included in the study. Data were collected retrospectively from the electronic medical charts of these subjects. Three hundred and sixty subjects were included in the study. The average duration of contact lens wear among the subjects was 9 ± 5 years (range: 5–35 years). The average age of the subjects was 31.38 ± 11.75 years (age range: 5–78 years). Hydrogel material and soft spherical type were preferred by most of the soft lens wearers (53 per cent). Eighty per cent of subjects followed hand hygiene and cleaning regimen practices. The preference for monthly replacement lenses and silicone hydrogel material increased over the years. Regular after-care consultations could enforce the need for compliance with hand hygiene and cleaning regimens among lens wearers.


  • An Ocular Surface Prosthesis for Keratoglobus and Terrien's Marginal Degeneration

    by Rajeswari Mahadevan, Asra Fathima, Rajni Rajan, Amudha Oli Arumugam

    Purpose: This case report describes the challenges in fitting corneas using the prosthetic replacement of ocular surface ecosystem (PROSE) device in a unique case of bilateral keratoglobus (KG) with Terrien's marginal degeneration (TMD). Case Report: KG and TMD are uncommon corneal ectatic conditions, characterized by protrusion and thinning of the cornea. Optical correction with spectacles is limited, as this may not provide the best‐corrected visual acuity because of irregular corneal astigmatism. Corneal gas‐permeable lenses can provide optimal vision, but they have poor fitting characteristics in advanced stages. The PROSE device has the advantage of masking the irregularity of the cornea with a tear lens and a contact lens power that provides a smooth refractive surface. This case report describes the fitting aspects of the PROSE device in a case diagnosed with KG and TMD. A generous vault allows the PROSE device to sink into the conjunctiva more, causing impingement, but a PROSE with higher vault is required as corneal clearance decreases with wear time. Corneal thickness measurements during the trial can give a better idea of corneal edema expected after prescribing the PROSE device. Optical coherence tomography is a useful tool for measuring diurnal changes in the corneal thickness and vault over a period in such challenging cases. Conclusions: Modification of not only the vault but also the haptic and total diameter of the device is required to achieve an optimal fit. Though challenging, successful fitting of the scleral lens in ectatic corneas is attainable, with the aid of anterior imaging and spline technologies.


  • PROSE for Irregular Corneas at a Tertiary Eye Care Center

    by Amudha Oli M.Phil.Optom. Arumugam, Rajni M.Phil.Optom. Rajan, Madhumathi B.S.Optom. Subramanian, Rajeswari Ph.D.Optom. Mahadevan

    Objective: The aim of this study was to report and discuss the clinical experience with PROSE (Prosthetic Replacement of Ocular Surface Ecosystem) practice at a tertiary eye care hospital. Methods: Retrospective data of patients who were prescribed PROSE during April 2011 to March 2012 in a tertiary eye care center in south India were analyzed. Data collected include patient demographics, indications of scleral lens fitting, previous correction modality, PROSE parameters, best-corrected visual acuity (BCVA) with spectacles, and BCVA with PROSE at initial assessment and few hours of wear. The BCVA before (with glasses) and after PROSE fitting was recorded in logMAR units. Results: The age of the patients ranged between 13 and 68 years (male:female 60:25) with a mean age of 32.44±13.45 years. Mean BCVA improved by 0.3 logMAR units (3 lines) after fitting with PROSE. There was a statistically significant difference between pre- and post-PROSE BCVA (P=0.0001). Failure of rigid gas-permeable lens fitting or intolerance was the common indication for PROSE in corneas with irregular astigmatism (refractive conditions). The other reasons for which PROSE was prescribed were pain, photophobia, comfort, ghosting of images, and frequent loss of smaller lenses. Toric scleral haptic was indicated in 62 eyes. The diameter, vault, and haptic measurements of PROSE in ocular surface disorders were much less and flatter than that of refractive conditions. Conclusions: PROSE device is a very useful alternative for irregular corneas to improve visual acuity, to improve comfort, and for symptomatic relief.


  • Open Access

    Association between various types of obesity and macular pigment optical density

    by A Gupta, R Raman, S Biswas, R Rajan, V Kulothungan, T Sharma

    To elucidate the association between macular pigment optical density (MPOD) and various types of obesity in the South-Indian population. In total, 300 eyes of 161 healthy volunteers of South-Indian origin were studied. MPOD was measured psychophysically at 0.25°, 0.50°, 1.00°, and 1.75° eccentricities from fovea. Anthropometric measurements included waist circumference (WC) and waist-to-hip ratio (WHR) and body mass index (BMI). Using the WHO Expert Consultation guidelines, obesity was defined based on BMI alone (BMI≥23 kg/m2), based on WC alone (WC≥90 cm for men and ≥80 cm for women), and based on WHR alone (≥0.90 for men and ≥0.85 for women). Isolated generalized obesity was defined as increased BMI and normal WC. Isolated abdominal obesity was defined as increased WC and normal BMI. Combined obesity was defined as increased BMI and increased WC. Mean MPOD at all eccentricities was not significantly different between men and women. Mean MPOD values did not significantly differ in various types of obesity, when compared with the normal subjects. On subgroup analysis, in age group ≥60 years, mean MPOD values were significantly higher in subjects with obesity based on BMI (0.61 vs0.41, P=0.036), obesity based on WHR (0.67 vs0.41, P=0.007), and isolated generalized obesity (0.66 vs0.41, P=0.045) in comparison with normal subjects at 0.25° eccentricity. We found lack of an association between MPOD and obesity in the South-Indian population. A similar finding was also noted on age group- and gender-wise analyses.


  • Open Access

    Morphological and Functional Correlates in Goldmann-Favre Syndrome: A Case Series

    by Madhavendra Bhandari, Rajni Rajan, P. Tandava Krishnan, Swakshyar Saumya Pal, Rajiv Raman, Tarun Sharma

    Bhandari M, et al. Korean J Ophthalmol. 2012 Apr;26(2):143-146. https://doi.org/10.3341/kjo.2012.26.2.143

  • Open Access

    Macular Pigment Optical Density in a South Indian Population

    by Rajiv Raman, Rajni Rajan, Sayantan Biswas, Kulothungan Vaitheeswaran, Tarun Sharma

    Purpose.: To estimate the normal value of macular pigment optical density (MPOD) in an adult south Indian sample. Methods.: Three hundred eyes of 161 healthy volunteers (30 men and 30 women in each of the age groups of 20–29, 30–39, 40–49, 50–59, and ≥60 years) underwent MPOD measurement with a macular densitometer. Thirty-two eyes were also checked for intersession variability. Results.: The mean MPODs in the Indian sample were 0.64 ± 0.23 log unit at 0.25° eccentricity, 0.50 ± 0.21 log unit at 0.5°, 0.37 ± 0.19 log unit at 1.00°, and 0.21 ± 0.16 log unit at 1.75°. At all the foveal eccentricities, the MPOD showed an increase from 20 to 29 to 30 to 39 years of age and thereby showed a decrease with age. The men aged 40 to 49 years had significantly higher MPOD than did the women (0.75 vs. 0.62 log unit, P = 0.039), and the women aged 50 to 59 years had higher MPOD than did the men (0.71 vs. 0.57 log unit, P = 0.019). There was no significant intersession or interocular variation. Conclusions.: This study establishes the MPOD normogram in an adult Indian sample.