VMViviana Rincón Montes

Viviana Rincón Montes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Viviana Rincón Montes has a total of 72 co-authors. Here are the top co-authors by number of shared publications:

  • Andreas Offenhäusser

    Forschungszentrum Jülich

    5 shared publications
  • Marie Jung

    Bioelectronics Institute of Biological Information Processing‐3 Forschungszentrum Jülich 52428 Jülich Germany

    4 shared publications
  • Andreas Offenhäusser

    Bioelectronics Institute of Biological Information Processing‐3 Forschungszentrum Jülich 52428 Jülich Germany

    3 shared publications
  • Jesús Enrique Chong Quero

    Escuela de Ingeniería y Ciencias, Tecnológico de Monterrey, Carr. al Lago de Guadalupe Km.3.5, Ciudad López Mateos 52926, Estado de México, Mexico

    3 shared publications
  • Lina Koschinski

    Bioelectronics Institute of Biological Information Processing‐3 Forschungszentrum Jülich Jülich Germany

    3 shared publications
  • Martin Kasavetov

    Institute of Biological Information Processing (IBI-3) – Bioelectronics, Forschungszentrum Jülich, Leo-Brandt-Str., D-52425 Jülich, Germany

    3 shared publications

Latest Publications

  • Open Access

    A mechanically stable neural probe for percutaneous high-resolution, multi-channel recordings in peripheral nerves

    by Sofiia Demchenko, Erkan Yilmaz, Anoushka Jain, Stas Koulchitsky, James P. Dunham, Anthony E. Pickering, Barbara Namer, Simon Musall, Viviana Rincón Montes

    The development of neural probes has enabled a deeper understanding and improved treatment for neurological disorders. Microneurography is currently the gold standard for assessing the electrophysiological signature of pain mechanisms in the human peripheral nervous system. However, its clinical utility is limited by the low recording yield and signal-to-noise ratio of single-electrode probes. To overcome these limitations, we developed mechanically robust, multi-electrode probes designed for acute percutaneous insertion and recording in peripheral nerves. The electrical and mechanical stability of these probes was confirmed through repeated insertions in artificial human skin and rat peripheral nerves. In addition, ex vivo and in vivo experiments demonstrated enhanced functional performance, with multi-site recordings enabling the isolation of single-fiber activity. Importantly, our probes can be operated analogously to conventional microneurography needles while substantially increasing the information yield, providing enhanced capabilities for minimally invasive peripheral nerve assessment.

  • Open Access

    PEDOT:PSS conducting eutectogel for enhanced electrical recording and stimulation in implantable neural interfaces

    by Martin Kasavetov, Ruben Ruiz-Mateos Serrano, Antonio Dominguez-Alfaro, Chaeyeon Lee, Matias Luis Picchio, David Mecerreyes, George G. Malliaras, Viviana Rincón Montes, Amparo Güemes

    Deep eutectic solvent–modified PEDOT:PSS enables single-layer thick, soft, and conductive coatings, enhancing charge transfer and neural interfacing, validated in vitro and in vivo in rat sciatic nerves. Original photograph, cartoon style applied with AI.


  • Open Access

    PEDOT:PSS conducting eutectogel for enhanced electrical recording and stimulation in implantable neural interfaces

    by Martin Kasavetov, Rubén Ruiz-Mateos Serrano, Antonio Dominguez-Alfaro, Chaeyeon Lee, Matias L. Picchio, David Mecerreyes, George G. Malliaras, Viviana Rincón Montes, Amparo Güemes González

    Conductive polymers such as PEDOT:PSS are widely used in bioelectronic interfaces due to their mixed ionic-electronic conductivity and biocompatibility. However, their mechanical fragility and limited processability constrain their performance in implantable devices. Deep eutectic solvents (DES), when combined with PEDOT:PSS, form eutectogels that enable thick, soft coatings. Here, we present a PEDOT:PSS-based eutectogel incorporating choline chloride: lactic acid and GOPS, integrated into flexible thin-film electrode arrays for sciatic nerve interfacing. These implants feature an array of electrodes and a pre-formed spiral geometry to conformally wrap small-diameter nerves. Devices were fabricated using standard photolithography and reactive ion etching techniques, allowing side-by-side comparison of PEDOT:PSS/DES with conventional PEDOT:PSS electrodes. PEDOT:PSS/DES enabled single-layer films up to 800 nm thick, significantly greater than PEDOT:PSS, and yielding over two-fold improvements in impedance and charge injection capacity in vitro . Acute in vivo electrophysiology in rats confirmed enhanced neural recording and stimulation capabilities, with lower impedance, higher capacitance, and reduced motor activation thresholds. While PEDOT:PSS/DES more reliably elicited motor responses at lower stimulation currents, electromyogram signal amplitudes from the tibialis anterioris at matched stimulation levels were comparable between materials. These results suggest that while superior electrochemical properties improve neural interface performance, local electrode-tissue interactions remain critical. Overall, this work establishes DES-modified PEDOT:PSS as a promising electrode material for soft neural interfaces and highlights its potential for advancing implantable bioelectronics.


  • Open Access

    Intraretinal Electrophysiology and Resistivity Profiles of WT and RCS Rat Retina

    by Marie Jung, Antje Willuweit, Viviana Rincón Montes

    Retinal prostheses have been utilized in the treatment of blindness resulting from retinal degeneration. However, they have not met patient expectations, leading to market withdrawals. As a result, research continues to focus on improving visual perception, such as by modeling retinal neural activation. The retina’s electrical resistivity profile is key, as it influences the current spread during electrical stimulation. To advance efficient stimulation parameters, more data on the electrical properties of the retina in both its healthy and diseased state is needed. While this question has been addressed in mouse models, few data are available from rat models, whose bigger size is advantageous for many applications. To address this knowledge gap, we used flexible penetrating microelectrode arrays to measure intraretinal impedance and electrophysiological activity in retinas from both healthy (WT) and diseased RCS rats, an established model of retinal degeneration. Consequently, we calculated resistivity profiles, consistent with previous mouse retina findings, and correlated them with spontaneous spiking activity. Hence, both impedance and electrophysiological measurements across retinal depths are demonstrated as valuable tools to identify the optimal stimulation depth and simulate the electric field spread during electrical stimulation, which is particularly useful for the development of retinal prostheses. These findings demonstrate that resistivity changes in the degenerated retina significantly impact stimulation protocols and electric field propagation.


  • Open Access

    High‐Density Flexible Neural Implants with Submicron Feedline Resolution

    by Lina Koschinski, Thomas Grap, Erkan Yilmaz, Marius Kleutgens, Simon Decke, Martin Kasavetov, Marie Jung, Alejandro Carnicer‐Lombarte, George Malliaras, Andreas Offenhäusser, et al.

    The development of high‐density microelectrode arrays (MEAs) for large‐scale brain recordings requires neural probes with reduced footprints to minimize tissue damage. One way to achieve this is by implementing dense electrode arrays with narrower feedline dimensions, though this increases susceptibility to capacitive coupling between electrical interconnects. To address this, this study explores the resolution limits for high‐density flexible MEAs by optimizing the fabrication using optical contact lithography (OCL) and electron beam lithography (EBL). OCL enables metal feedlines with widths of 520 nm and interconnect spaces of 280 nm, while EBL allows the realization of 50 nm feedlines with 150 nm spaces on flexible parylene C substrates. Based on these techniques, we fabricate a flexible 64‐channel intracortical implant with a miniaturized cross‐section of only 50 × 6 or 70 × 6 µm 2 . In vivo validation in awake rats demonstrates that the fabricated, high‐density flexible intracortical implants with submicron feedline resolution offer low‐impedance electrodes and reduced crosstalk, enabling reliable neuronal recordings. These findings demonstrate the feasibility of miniaturizing flexible MEAs using a single‐metal layer process, thereby reducing manufacturing complexity in high‐density thin‐film polymer‐based neural interfaces.


  • Open Access

    Flexible 3D Kirigami Probes for In Vitro and In Vivo Neural Applications

    by Marie Jung, Jamal Abu Shihada, Simon Decke, Lina Koschinski, Peter Severin Graff, Sebastián Maruri Pazmino, Anke Höllig, Henner Koch, Simon Musall, Andreas Offenhäusser, et al.

    3D microelectrode arrays (MEAs) are gaining popularity as brain–machine interfaces and platforms for studying electrophysiological activity. Interactions with neural tissue depend on the electrochemical, mechanical, and spatial features of the recording platform. While planar or protruding 2D MEAs are limited in their ability to capture neural activity across layers, existing 3D platforms still require advancements in manufacturing scalability, spatial resolution, and tissue integration. In this work, a customizable, scalable, and straightforward approach to fabricate flexible 3D kirigami MEAs containing both surface and penetrating electrodes, designed to interact with the 3D space of neural tissue, is presented. These novel probes feature up to 512 electrodes distributed across 128 shanks in a single flexible device, with shank heights reaching up to 1 mm. The 3D kirigami MEAs are successfully deployed in several neural applications, both in vitro and in vivo, and identified spatially dependent electrophysiological activity patterns. Flexible 3D kirigami MEAs are therefore a powerful tool for large‐scale electrical sampling of complex neural tissues while improving tissue integration and offering enhanced capabilities for analyzing neural disorders and disease models where high spatial resolution is required.


  • Open Access

    Flexible 3D kirigami probes for in vitro and in vivo neural applications

    by Marie Jung, Jamal Abu Shihada, Simon Decke, Lina Koschinski, Peter Severin Graff, Sebastian Maruri Pazmino, Anke Hoellig, Henner Koch, Simon Musall, Andreas Offenhaeusser, et al.

    Three-dimensional (3D) microelectrode arrays (MEAs) are gaining popularity as brain-machine interfaces and platforms for studying electrophysiological activity. Interactions with neural tissue depend on the electrochemical, mechanical, and spatial features of the recording platform. While planar or protruding two-dimensional MEAs are limited in their ability to capture neural activity across layers, existing 3D platforms still require advancements in manufacturing scalability, spatial resolution, and tissue integration. In this work, we present a customizable, scalable, and straightforward approach to fabricate flexible 3D kirigami MEAs containing both surface and penetrating electrodes, designed to interact with the 3D space of neural tissue. These novel probes feature up to 512 electrodes distributed across 128 shanks in a single flexible device, with shank heights reaching up to 1 mm. We successfully deployed our 3D kirigami MEAs in several neural applications, both in vitro and in vivo, and identified spatially dependent electrophysiological activity patterns. Flexible 3D kirigami MEAs are therefore a powerful tool for large-scale electrical sampling of complex neural tissues while improving tissue integration and offering enhanced capabilities for analyzing neural disorders and disease models where high spatial resolution is required.


  • Top Cited Papers
    Open Access

    Highly Customizable 3D Microelectrode Arrays for In Vitro and In Vivo Neuronal Tissue Recordings

    by J. Abu Shihada, M. Jung, S. Decke, L. Koschinski, S. Musall, V. Rincón Montes, A. Offenhäusser

    Planar microelectrode arrays (MEAs) for – in vitro or in vivo – neuronal signal recordings lack the spatial resolution and sufficient signal‐to‐noise ratio (SNR) required for a detailed understanding of neural network function and synaptic plasticity. To overcome these limitations, a highly customizable three‐dimensional (3D) printing process is used in combination with thin film technology and a self‐aligned template‐assisted electrochemical deposition process to fabricate 3D‐printed‐based MEAs on stiff or flexible substrates. Devices with design flexibility and physical robustness are shown for recording neural activity in different in vitro and in vivo applications, achieving high‐aspect ratio 3D microelectrodes of up to 33:1. Here, MEAs successfully record neural activity in 3D neuronal cultures, retinal explants, and the cortex of living mice, thereby demonstrating the versatility of the 3D MEA while maintaining high‐quality neural recordings. Customizable 3D MEAs provide unique opportunities to study neural activity under regular or various pathological conditions, both in vitro and in vivo, and contribute to the development of drug screening and neuromodulation systems that can accurately monitor the activity of large neural networks over time.


  • Open Access

    Validation of transparent and flexible neural implants for simultaneous electrophysiology, functional imaging, and optogenetics

    by Lina Koschinski, Bohdan Lenyk, Marie Jung, Irene Lenzi, Björn Kampa, Dirk Mayer, Andreas Offenhäusser, Simon Musall, Viviana Rincón Montes

    We developed and compared transparent micro electrocorticography arrays (μECoGs) to combine electrophysiology and functional imaging. PEDOT:PSS-based μECoGs had the best trade-off of material and physical properties for chronic in vivo experiments.


  • Open Access

    Toward a Bidirectional Communication Between Retinal Cells and a Prosthetic Device – A Proof of Concept

    by Viviana Rincón Montes, Jana Gehlen, Stefan Lück, Wilfried Mokwa, Frank Müller, Peter Walter, Andreas Offenhäusser

    Background: Significant progress toward the recovery of useful vision in blind patients with severe degenerative retinal diseases caused by photoreceptor death has been achieved with the development of visual prostheses that stimulate the retina electrically. However, currently used prostheses do not provide feedback about the retinal activity before and upon stimulation and do not adjust to changes during the remodeling processes in the retina. Both features are desirable to improve the efficiency of the electrical stimulation (ES) therapy offered by these devices. Accordingly, devices that not only enable ES but at the same time provide information about the retinal activity are beneficial. Given the above, a bidirectional communication strategy, in which inner retinal cells are stimulated and the output neurons of the retina, the ganglion cells, are recorded using penetrating microelectrode arrays (MEAs) is proposed. Methods: Custom-made penetrating MEAs with four silicon-based shanks, each one with three or four iridium oxide electrodes specifically designed to match retinal dimensions were used to record the activity of light-adapted wildtype mice retinas and degenerated retinas from rd10 mice in vitro. In addition, responses to high potassium concentration and to light stimulation in wildtype retinas were examined. Furthermore, voltage-controlled ES was performed. Results: The spiking activity of retinal ganglion cells (RGCs) was recorded at different depths of penetration inside the retina. Physiological responses during an increase of the extracellular potassium concentration and phasic and tonic responses during light stimulation were captured. Moreover, pathologic rhythmic activity was recorded from degenerated retinas. Finally, ES of the inner retina and simultaneous recording of the activity of RGCs was accomplished. Conclusion: The access to different layers of the retina with penetrating electrodes while recording at the same time the spiking activity of RGCs broadens the use and the field of action of multi-shank and multi-site penetrating MEAs for retinal applications. It enables a bidirectional strategy to stimulate inner retinal cells electrically and to record from the spiking RGCs simultaneously (BiMEA). This opens the possibility of a feedback loop system to acknowledge the success of ES carried out by retinal prostheses.