AKAdi Kurniawan

Adi Kurniawan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Adi Kurniawan has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Short-circuit current analysis of DC distribution system in a ship with non-electric propulsion

    by Adi Kurniawan, Ahlur Roi Novanto Gumilang, Sardono Sarwito, Firman Budianto, Akhmad Reinaldy Kurniawan

    Converting conventional AC radial shipboard distribution system to DC system has been recognized as a potential high impact solution to reduce ship’s fuel consumption. As big ships in Indonesia commonly use low voltage AC (LVAC) distribution system an effort to apply low voltage direct current (LVDC) distribution system without replace the propulsion system is a plausible choice. However, technical and economical investigations are required before recommendation to convert the shipboard distribution system to LVDC is officially launched. In this study, technical aspect in the term of short-circuit current is discussed. The goal of this study is to analyze how much the impact on the short-circuit current when LVDC system replaces LVAC system. The impact may affect the feasibility of LVDC system as the short-circuit current in a system dictate the scheme and capacity of the protection devices. Numerical simulations on a sample vessel are performed to obtain the profile of maximum short-circuit currents on all panels. The results show that the utilization of LVDC system decreases the short-circuit current by 10 times. Further investigations on the economic aspect needs to be performed to give clearer view of the feasibility of the LVDC system.

  • Power Loss Simulation due to Reconfiguration of Shipboard AC to DC Electrical Distribution System with Hybrid Energy Sources

    by Adi Kurniawan, Nur A. Rochim, Sardono Sarwito

    According to study data released by International Maritime Organization (IMO), emissions from ships contribute 2.2% of the greenhouse gas CO 2 , as well as 13% of SOx pollutants and 15% of NOx pollutants from the total air pollution in the world. Thus, innovation by utilizing renewable energy such as the addition of photovoltaic (PV) is required. Several studies also have shown that an electric distribution system using direct current (DC) has several advantages over the conventional alternating current (AC) power distribution system. However, the investigation of power losses between both systems in non-electric propelled ship, further supplied with hybrid PV -diesel generator power has not been performed. This research is conducted based on power flow simulation during four ship's four operation modes in power system simulator. Based on the simulations that have been carried out, the power loss value in a DC distribution system is always smaller than the power loss value in an AC distribution system. When photovoltaic (PV) panels are installed instead of a diesel generator alone, power loss is also demonstrated to be lessened. In loading-unloading mode without using photovoltaic, the AC distribution system exhibits the maximum power loss value, with a power loss value of 3,267 kW and 2,223 kVAR or about 0.23% of the total power.


  • Harmonic Analysis due to Reconfiguration of Shipboard AC to DC Electrical Distribution System with Hybrid Energy Sources

    by Adi Kurniawan, Edo F. Putra, Sardono Sarwito

    This study conducted a harmonics analysis on the tanker ship electrical system. Harmonics is analysed for two types of electrical distribution system, namely AC and DC system which also adopt hybrid diesel generator and photovoltaic as the energy sources. The analysis is divided into four ship operation modes, consist of at port, leaving arriving, loading unloading, and sailing. The analysis was carried out to know the effect of reconfiguration from AC to DC distribution system and the addition of photovoltaic to the total harmonics distortion (THD). The analysis was carried out using a power system simulator software. The results show that the DC distribution system has a larger THD than the AC. The largest THD found in the AC distribution system is 5.38% while it exceeds 12% in the DC system. Other than the largest, several other buses in the DC system also exceeding 8% limit of THD regulated by Indonesian classification bureau (BKI). Considering other advantages of DC system, the disadvantage in the harmonics should be handled by installing harmonic filter. In this study case, the THD in the DC system can be reduced to less than 3% by installing 13 kVAR harmonic filter.

  • Open Access

    Analisis Numerik Jatuh Tegangan pada Derek Kontainer di Pelabuhan Akibat Arus Mula Motor

    by Adi Kurniawan, Firman Rachmat Wahyudy, Sardono Sarwito

    Analisis Numerik Jatuh Tegangan pada Derek Kontainer di Pelabuhan Akibat Arus Mula Motor

  • Open Access

    Power flow analysis of DC distribution system in a ship with non-electric propulsion

    by Akhmad Reinaldy Kurniawan, Adi Kurniawan, Sardono Sarwito, Ahlur Roi Novanto Gumilang, Firman Budianto

    Direct current (DC) shipboard power distribution system offers higher power efficiency and voltage stability compared to the alternating current (AC) systems due to lower impedance. The implementation of DC distribution system in all-electric ship seems to be worthy since the reduction of power loss and voltage drop could overcome the drawback of DC system. However, the effectiveness of DC distribution system in ship with non-electric propulsion has not been investigated yet. Unlike in an all-electric ship, electric power flow in the distribution system of a ship with mechanic propulsion is considerably lower. The study aims to provide numerical analysis of power loss and voltage drop reduction on DC distribution system that applied to a ship with mechanic propulsion. The power flow analysis is performed on a tanker ship. Contrary to the hypothesis, the results show that the DC power distribution increase the power losses about 15% compared to AC system due to the addition of rectifier and inverter. However, the voltage drops are decreased in DC distribution system. Further investigation in the other aspects should be performed before concludes whether DC distribution system is worthy to be used in the aforementioned ship.


  • Open Access

    Analysis of Distribution of Flood Disaster Hazard in Tangerang City

    by C B Pribadi, T Hariyanto, A Kurniawan

    Tangerang City was largest city in Banten Province with total area of 184.23 km2. Tangerang City was generally combination of coastal areas with lowlands condition which is located along Cisadane River. Mapping of flood-prone areas in Tangerang City aims to identify areas which have potential for flooding, so these areas can be analyzed for preventing action. In this research, flood-prone areas were identified using scoring method. The flood parameters consist of land height, slope, rainfall, soil type, land cover, and river range. Spatial information was represented in form of map, while attributes of spatial information were represented in tabular form using different parameters and weight values in mapping flood hazard in Tangerang City. The results show us that level of flood hazard in Tangerang City was divided into four classes of hazard, namely level of flood hazard “safe” in Benda District with area of 0,831 Ha, level of flood hazard “slightly vulnerable” in Jatiuwung District with area of 155,897 Ha, level of flood hazard “Prone” occur in Pinang District, which has area of 1.360,161 Ha, while level of flood hazard “very vulnerable” was in Benda District, which has area of 1.358,454 Ha.

  • PSO based on Generator Scheduling for Low Voltage Direct Current Distribution System onboard Ship with Mechanical Propulsion System

    by Dennis Chaniago Ramadhan, Adi Kurniawan, Indra Ranu Kusuma

    Along with advances in power electronics technology at the end of this decade, the application of a low-voltage direct current (L VDC) electric power distribution system began to be redeveloped. It is considered to have advantages in fuel economy, space efficiency due to the absence of transformer components, and lower emissions. To get the benefits of a direct current distribution system in fuel economy is necessary to optimize generator scheduling. One of the optimization methods used is Particle Swarm Optimization (PSO), which is inspired by the movement of living things such as birds and fish that adapt to the environment. This study aims to conduct a generator scheduling optimization using the PSO method on a mechanical propulsion-driven vessel. The ship with mechanical propulsion was chosen because it is considered the ship most often operates in Indonesian. The optimization process will be carried out by modeling the characteristics of the generator used on the study object ship with two methods of second interpolation and third interpolation. The results of the calculation of fuel consumption for the LV AC and L VDC systems with conventional load sharing show savings on the LVDC system of 18.8953 kg/h, 81.7884 kg/h, 19.5244 kg/h, 46.5792 kg/h in sailing, maneuvering, cargo handling and at port modes. The simulation results for the LV AC and L VDC systems with load sharing using the PSO method show fuel consumption savings on the L VDC system of 18.8953 kg/h, 81.7884 kg/h, 19.5244 kg/h, 59.98 57 kg/h in sailing, maneuvering, cargo handling and at ports modes. The simulation results for the L VDC system with conventional load sharing and PSO only show savings in the at port mode of 13.41 kg/h. However, the simulation results for the LVAC system with conventional load sharing and PSO are similar.


  • Open Access

    Two-step artificial neural network to estimate the solar radiation at Java Island

    by Adi Kurniawan, Eiji Shintaku

    The availability of information about solar radiation characteristics, particularly solar radiation predictions, is important for efficiently designing solar energy systems. Solar radiation information is not available in Indonesia because official measurements have not been conducted by the Indonesian Meteorological, Climatology, and Geophysical Agency (BMKG). In this study, a new two-step artificial neural network (ANN) is proposed to estimate both the daily average and hourly solar radiation at Java Island, Indonesia. The input parameters for the daily average solar radiation estimation are the location and time required, along with five selected monthly meteorological parameters that BMKG predicts for the subsequent month. The selected meteorological parameters are temperatures, relative humidity, and precipitation. The estimated daily average solar radiation is then used as the input parameter of the hourly solar radiation estimation along with the local time and location. The ANN training was conducted using two years of data, 2018 and 2019, from Surabaya and Jakarta, while the validation was performed in the same cities for January through July 2020. The accuracy of the proposed method is comparable to previous studies with an average R2 of 98.70% for the daily average solar radiation estimate and 97.44% for the hourly solar radiation estimate.


  • Open Access

    An evaluation of the artificial neural network based on the estimation of daily average global solar radiation in the city of Surabaya

    by Adi Kurniawan, Anisa Harumwidiah

    The estimation of the daily average global solar radiation is important since it increases the cost efficiency of solar power plant, especially in developing countries. Therefore, this study aims at developing a multi layer perceptron artificial neural network (ANN) to estimate the solar radiation in the city of Surabaya. To guide the study, seven (7) available meteorological parameters and the number of the month was applied as the input of network. The ANN was trained using five-years data of 2011-2015. Furthermore, the model was validated by calculating the mean average percentage error (MAPE) of the estimation for the years of 2016-2019. The results confirm that the aforementioned model is feasible to generate the estimation of daily average global solar radiation in Surabaya, indicated by MAPE of less than 15% for all testing years.


  • Open Access

    Pembuatan Modul Tutorial Dasar Ladder Diagram Programmable Logic Controller Dalam Jejaring

    by Adi Kurniawan, Juniarko Prananda, Sardono Sarwito, Eddy Setyo Koenhardono, Indra Ranu Kusuma, Agoes Ahmad Masroeri

    Pada sebagian Sekolah Menengah Kejuruan (SMK) yang memiliki jurusan teknik elektro dan sejenisnya, Programmable Logic Controller (PLC) telah banyak dipelajari untuk menghasilkan lulusan yang memiliki kemampuan yang dibutuhkan oleh industri saat ini. Dalam kondisi pandemi Covid-19, pembelajaran PLC pada sebagian sekolah menjadi terhambat karena tidak semua siswa memiliki kuota internet maupun kapasitas komputer yang cukup besar untuk mengunduh ataupun menginstall perangkat lunak untuk mempelajari PLC. Permasalahan ini dapat diatasi dengan melakukan pembelajaran Ladder Diagram PLC dalam jejaring tanpa perlu mengunduh perangkat lunak, yaitu melalui situs PLC Fiddle. Karena PLC Fiddle belum banyak diketahui dan dipelajari oleh para pengajar ataupun pembelajar di Indonesia, pada kegiatan ini modul dasar tutorial PLC Fiddle dibuat.untuk memudahkan para guru SMK memberikan pembelajaran kepada para siswa dalam jejaring. Selain itu, bagi SMK yang belum menerapkan pembelajaran PLC karena keterbatasan fasilitas, pengenalan dan pembelajaran PLC Fiddle dapat digunakan untuk memulai memberikan pembelajaran PLC kepada para siswa. Selanjutnya, modul tutorial ini akan mulai diperkenalkan melalui kegiatan pelatihan untuk para guru SMK.