Krzysztof Iwan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Krzysztof Iwan has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
I. A. Śmietańska
Medical University of Gdansk
1 shared publicationI. Moson
Gdansk University of Technology
1 shared publicationJ. Bigda
Medical University of Gdansk
1 shared publicationJ. Krajewski
Medical University of Gdansk
1 shared publicationJ. Luszcz
1 shared publication- Janusz Nieznanski
Gdansk University of Technology, Gdansk, Poland
1 shared publication
Latest Publications
- 23 January 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (6) , 925-928
Assessment of usefulness exhibited by different tacks in laparoscopic ventral hernia repair
Laparoscopic ventral hernia repair is becoming a popular technique with good results and fast postoperative recovery. The mesh is placed directly under the peritoneum and anchored with transabdominal sutures and tacks. However, the ideal size of the mesh covering the hernia orifice is know, nor the ideal type or amount of tacks has to be described. To assess the forces acting on a single tack, a mathematical model of the ventral hernia was created. The force was described in reference to the surface of the hernia orifice and the pressure in the abdominal cavity. The following different types of mesh were examined in vitro: Proceed (knitted mesh), Dual Mesh (expanded polytetrafluoroethylene [ePTFE] flat mesh), and Shelhigh (biologic flat mesh). The following different tacks also were examined: Protac, Anchor, and EMS. A pig model was used to measure the forces needed to destroy the connection between mesh and tissue and to describe the place of destruction (mesh, tissue, or tack) and the force needed. The force acting on a single tack proportionally depends on the surface of the hernia orifice and the pressure in the abdominal cavity. The force needed to disconnect the tissue and mesh reached 8.97 ± 0.11 N for ProTac, 2.67 ± 0.22 N for Anchor, and 6.67 ± 1.32 N for EMS. These values do not allow the mesh to be held in the right position when the orifice exceeds 10 cm for Protac and EMS. The disconnection of the EMS and Protac junction damages the tissue. Anchor tacks are insufficient to hold the mesh and stay in the tissue In the case of small hernias (diameter<10 cm) EMS or ProTac used alone are not enough to hold the mesh. Anchor is not recommended alone in any hernia.
- 23 January 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (6) , 925-928
Assessment of usefulness exhibited by different tacks in laparoscopic ventral hernia repair
Laparoscopic ventral hernia repair is becoming a popular technique with good results and fast postoperative recovery. The mesh is placed directly under the peritoneum and anchored with transabdominal sutures and tacks. However, the ideal size of the mesh covering the hernia orifice is know, nor the ideal type or amount of tacks has to be described. To assess the forces acting on a single tack, a mathematical model of the ventral hernia was created. The force was described in reference to the surface of the hernia orifice and the pressure in the abdominal cavity. The following different types of mesh were examined in vitro: Proceed (knitted mesh), Dual Mesh (expanded polytetrafluoroethylene [ePTFE] flat mesh), and Shelhigh (biologic flat mesh). The following different tacks also were examined: Protac, Anchor, and EMS. A pig model was used to measure the forces needed to destroy the connection between mesh and tissue and to describe the place of destruction (mesh, tissue, or tack) and the force needed. The force acting on a single tack proportionally depends on the surface of the hernia orifice and the pressure in the abdominal cavity. The force needed to disconnect the tissue and mesh reached 8.97 ± 0.11 N for ProTac, 2.67 ± 0.22 N for Anchor, and 6.67 ± 1.32 N for EMS. These values do not allow the mesh to be held in the right position when the orifice exceeds 10 cm for Protac and EMS. The disconnection of the EMS and Protac junction damages the tissue. Anchor tacks are insufficient to hold the mesh and stay in the tissue In the case of small hernias (diameter<10 cm) EMS or ProTac used alone are not enough to hold the mesh. Anchor is not recommended alone in any hernia.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1-9
AC motor transients and EMI emission analysis in the ASD by parasitic resonance effects identification
Investigation of common mode (CM) electromagnetic interference (EMI) currents in an AC motor fed by the pulse width modulated (PWM) voltage converter requires a model of the motor that take into account parasitic capacitances existing in the motor windings. Presented CM transfer impedance analysis method shows that the motor voltage transient is strongly related to the resonance effects observed on the windings CM impedance. The wide frequency CM impedance characteristics analysis allows to identify and determine resonance effects which are the primary reasons for voltage ringing phenomena. The paper presents a circuit modelling method of the AC motor windings parasitic capacitances, which allows to take into account the change of the winding to ground capacitance for different frequency ranges in the conducted frequency range. The proposed circuit model and its parameter identification method make possible more accurate CM currents modelling in the AC motor windings fed by the converter.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1-9
AC motor transients and EMI emission analysis in the ASD by parasitic resonance effects identification
Investigation of common mode (CM) electromagnetic interference (EMI) currents in an AC motor fed by the pulse width modulated (PWM) voltage converter requires a model of the motor that take into account parasitic capacitances existing in the motor windings. Presented CM transfer impedance analysis method shows that the motor voltage transient is strongly related to the resonance effects observed on the windings CM impedance. The wide frequency CM impedance characteristics analysis allows to identify and determine resonance effects which are the primary reasons for voltage ringing phenomena. The paper presents a circuit modelling method of the AC motor windings parasitic capacitances, which allows to take into account the change of the winding to ground capacitance for different frequency ranges in the conducted frequency range. The proposed circuit model and its parameter identification method make possible more accurate CM currents modelling in the AC motor windings fed by the converter.
- 13 December 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21669538,p. 209-212
Modelling conducted EMI in inverter-fed AC motor
- 13 December 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21669538,p. 209-212
Modelling conducted EMI in inverter-fed AC motor
- 1 October 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 497-501
Circuit-oriented model of the switched reluctance motor for drive systems simulation
- 1 October 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 497-501
Circuit-oriented model of the switched reluctance motor for drive systems simulation