Hassan Tavakoli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hassan Tavakoli has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Hedayatollah Ghourchian
Laboratory of Bioanalysis, Institute of Biochemistry and Biophysics, University of Tehran, Tehran, Iran
3 shared publications Masumeh Goodarzi
Radiation Sciences Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
3 shared publicationsA.A. Moosavi-Movahedi
Institute of Biochemistry and Biophysics, University of Tehran, Tehran 1384, Islamic Republic of Iran
2 shared publicationsH. Ghourchian
University of Tehran
2 shared publicationsA. Gholamrezanezhad
1 shared publicationA.A. Saboury
Institute of Biochemistry and Biophysics, University of Tehran, Tehran 1384, Islamic Republic of Iran
1 shared publication
Latest Publications
- 8 December 2025
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
Application of magnetic resonance spectroscopy (MRS) in photo-thermal therapy response of U87-MG human glioma cells with gold-coated iron oxide nanoparticles: an in vivo study
Accurate prediction of the response to nano-photothermal therapy (NPTT) requires rapid feedback from the tumor. This study utilizes proton magnetic resonance spectroscopy (1H-MRS) to non-invasively assess metabolic changes in glioma treated with NPTT using gold-coated iron oxide nanoparticles, providing insight into early therapeutic efficacy. The study was conducted on nude mice bearing U87-MG human glioma xenografts, which were assigned to distinct treatment cohorts: Au@Fe₂O₃ core-shell nanoparticles alone, laser irradiation alone, and the combined nano-photothermal therapy. The efficacy was determined by assessing post-treatment alterations in tumor volume and corresponding changes in choline and lipid metabolite signals detected via 1H-MRS. Analysis of metabolite ratios, normalized to the water peak, demonstrated a significant post-NPTT therapeutic response. A marked decrease was observed in both the choline/creatine ratio (from 0.48 ± 0.17 to 0.24 ± 0.07) and the choline/lipid ratio (from 0.47 ± 0.23 to 0.13 ± 0.06). Notably, these metabolic alterations were evident within 24 h of the procedure. In contrast, significant reductions in tumor volume were not detectable until day 9 post-treatment. 1H-MRS analysis of metabolite ratios serves as a sensitive, early biomarker of the biological response to NPTT. The capacity for in vivo assessment of therapeutic efficacy within 24 h post-procedure provides a significant advantage. This rapid feedback can critically inform clinical decision-making and guide the strategic planning of subsequent cancer treatments.
- 8 December 2025
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
Application of magnetic resonance spectroscopy (MRS) in photo-thermal therapy response of U87-MG human glioma cells with gold-coated iron oxide nanoparticles: an in vivo study
Accurate prediction of the response to nano-photothermal therapy (NPTT) requires rapid feedback from the tumor. This study utilizes proton magnetic resonance spectroscopy (1H-MRS) to non-invasively assess metabolic changes in glioma treated with NPTT using gold-coated iron oxide nanoparticles, providing insight into early therapeutic efficacy. The study was conducted on nude mice bearing U87-MG human glioma xenografts, which were assigned to distinct treatment cohorts: Au@Fe₂O₃ core-shell nanoparticles alone, laser irradiation alone, and the combined nano-photothermal therapy. The efficacy was determined by assessing post-treatment alterations in tumor volume and corresponding changes in choline and lipid metabolite signals detected via 1H-MRS. Analysis of metabolite ratios, normalized to the water peak, demonstrated a significant post-NPTT therapeutic response. A marked decrease was observed in both the choline/creatine ratio (from 0.48 ± 0.17 to 0.24 ± 0.07) and the choline/lipid ratio (from 0.47 ± 0.23 to 0.13 ± 0.06). Notably, these metabolic alterations were evident within 24 h of the procedure. In contrast, significant reductions in tumor volume were not detectable until day 9 post-treatment. 1H-MRS analysis of metabolite ratios serves as a sensitive, early biomarker of the biological response to NPTT. The capacity for in vivo assessment of therapeutic efficacy within 24 h post-procedure provides a significant advantage. This rapid feedback can critically inform clinical decision-making and guide the strategic planning of subsequent cancer treatments.
- 14 March 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140  (3)
Quality optimization of neutron and gamma concrete shields doped with galena, hematite and limonite for Am-Be neutron source and 137Cs and 60Co gamma sources using experimental method and Monte Carlo simulation
- 14 March 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140  (3)
Quality optimization of neutron and gamma concrete shields doped with galena, hematite and limonite for Am-Be neutron source and 137Cs and 60Co gamma sources using experimental method and Monte Carlo simulation
- Open Access
- 5 October 2024
- Published by Elsevier in Biosensors and Bioelectronics: X
- Vol. 21
A novel approach to tyrosinase-based biosensors: Electrode reactions and biological measurement
- 5 October 2024
- Published by Elsevier in Biosensors and Bioelectronics: X
- Vol. 21
Open AccessA novel approach to tyrosinase-based biosensors: Electrode reactions and biological measurement
- Open Access
- 1 January 2024
- Published by Salvia Medical Sciences Ltd in Journal of Biomedical Physics and Engineering
- Vol. online  (6) , 575-588
Deep CNN-based Fully Automated Segmentation of Pelvic Multi-Organ on CT Images for Prostate Cancer Radiotherapy
Background: Manual delineation of volumes for prostate radiotherapy treatment is a time-consuming task for radiation oncologists and is also prone to variability. Deep learning-based auto-segmentation methods showed promising results with accurate and high-fidelity contours.Objective: The objective of this study was to evaluate the feasibility of a Computed Tomography (CT)-based deep learning auto-segmentation algorithm for multi-organ delineation in prostate radiotherapy.Material and Methods: In this single-institution retrospective study, a total of 118 patients with prostate cancer were included. We applied 3D nnU-net deep convolutional neural network architecture, a self-adapting ensemble method for simultaneous fast and reproducible multi-organ auto-contouring. The dataset was randomly divided into training and test sets from 95 and 23 patients, respectively. Intensity-modulated radiotherapy plans were generated for both manual and automatic delineations using identical optimization settings. Contours were assessed in terms of the Dice Similarity Coefficient (DSC), and average Hausdorff Distance (HD). Dose distributions were additionally evaluated using parameters derived from Dose-Volume Histograms (DVH).Results: On the test set, 3D nnU-net achieved the best performance in the bladder (DSC:0.97, HD:4.13), right femur head (DSC:0.96, HD:3.58), left femur head (DSC:0.96, HD:3.95), rectum (DSC:0.9, HD:10.04), prostate (DSC:0.82, HD:3.68), lymph nodes (DSC:0.77, HD:15.5), and seminal vesicles (DSC:0.69, HD:10.95). DVH parameters of targets and Organ at Risks (OARs) were significantly different except for lymph nodes and femoral heads between treatment plans based on manual and automatic contours. Conclusion: The 3D nnU-net architecture can be successfully used for multi-organ segmentation in the male pelvic area.
- 1 January 2024
- Published by Salvia Medical Sciences Ltd in Journal of Biomedical Physics and Engineering
- Vol. online  (6) , 575-588
Open AccessDeep CNN-based Fully Automated Segmentation of Pelvic Multi-Organ on CT Images for Prostate Cancer Radiotherapy
Background: Manual delineation of volumes for prostate radiotherapy treatment is a time-consuming task for radiation oncologists and is also prone to variability. Deep learning-based auto-segmentation methods showed promising results with accurate and high-fidelity contours.Objective: The objective of this study was to evaluate the feasibility of a Computed Tomography (CT)-based deep learning auto-segmentation algorithm for multi-organ delineation in prostate radiotherapy.Material and Methods: In this single-institution retrospective study, a total of 118 patients with prostate cancer were included. We applied 3D nnU-net deep convolutional neural network architecture, a self-adapting ensemble method for simultaneous fast and reproducible multi-organ auto-contouring. The dataset was randomly divided into training and test sets from 95 and 23 patients, respectively. Intensity-modulated radiotherapy plans were generated for both manual and automatic delineations using identical optimization settings. Contours were assessed in terms of the Dice Similarity Coefficient (DSC), and average Hausdorff Distance (HD). Dose distributions were additionally evaluated using parameters derived from Dose-Volume Histograms (DVH).Results: On the test set, 3D nnU-net achieved the best performance in the bladder (DSC:0.97, HD:4.13), right femur head (DSC:0.96, HD:3.58), left femur head (DSC:0.96, HD:3.95), rectum (DSC:0.9, HD:10.04), prostate (DSC:0.82, HD:3.68), lymph nodes (DSC:0.77, HD:15.5), and seminal vesicles (DSC:0.69, HD:10.95). DVH parameters of targets and Organ at Risks (OARs) were significantly different except for lymph nodes and femoral heads between treatment plans based on manual and automatic contours. Conclusion: The 3D nnU-net architecture can be successfully used for multi-organ segmentation in the male pelvic area.
- Open Access
- 1 January 2023
- Published by Salvia Medical Sciences Ltd in Journal of Biomedical Physics and Engineering
- Vol. 13  (5) , 421-432
Investigating the Ability of Radiomics Features for Diagnosis of the Active Plaque of Multiple Sclerosis Patients
Background: Multiple sclerosis (MS) is the most common non-traumatic disabling disease.Objective: The aim of this study is to investigate the ability of radiomics features for diagnosing active plaques in patients with MS from T2 Fluid Attenuated Inversion Recovery (FLAIR) images.Material and Methods: In this experimental study, images of 82 patients with 122 MS lesions were investigated. Boruta and Relief algorithms were used for feature selection on the train data set (70%). Four different classifier algorithms, including Multi-Layer Perceptron (MLP), Gradient Boosting (GB), Decision Tree (DT), and Extreme Gradient Boosting (XGB) were used as classifiers for modeling. Finally, Performance metrics were obtained on the test data set (30%) with 1000 bootstrap and 95% confidence intervals (95% CIs).Results: A total of 107 radiomics features were extracted for each lesion, of which 7 and 8 features were selected by the Relief method and Boruta method, respectively. DT classifier had the best performance in the two feature selection algorithms. The best performance on the test data set was related to Boruta-DT with an average accuracy of 0.86, sensitivity of 1.00, specificity of 0.84, and Area Under the Curve (AUC) of 0.92 (95% CI: 0.92-0.92). Conclusion: Radiomics features have the potential for diagnosing MS active plaque by T2 FLAIR image features. Additionally, choosing the feature selection and classifier algorithms plays an important role in the diagnosis of active plaque in MS patients. The radiomics-based predictive models predict active lesions accurately and non-invasively.
- 1 January 2023
- Published by Salvia Medical Sciences Ltd in Journal of Biomedical Physics and Engineering
- Vol. 13  (5) , 421-432
Open AccessInvestigating the Ability of Radiomics Features for Diagnosis of the Active Plaque of Multiple Sclerosis Patients
Background: Multiple sclerosis (MS) is the most common non-traumatic disabling disease.Objective: The aim of this study is to investigate the ability of radiomics features for diagnosing active plaques in patients with MS from T2 Fluid Attenuated Inversion Recovery (FLAIR) images.Material and Methods: In this experimental study, images of 82 patients with 122 MS lesions were investigated. Boruta and Relief algorithms were used for feature selection on the train data set (70%). Four different classifier algorithms, including Multi-Layer Perceptron (MLP), Gradient Boosting (GB), Decision Tree (DT), and Extreme Gradient Boosting (XGB) were used as classifiers for modeling. Finally, Performance metrics were obtained on the test data set (30%) with 1000 bootstrap and 95% confidence intervals (95% CIs).Results: A total of 107 radiomics features were extracted for each lesion, of which 7 and 8 features were selected by the Relief method and Boruta method, respectively. DT classifier had the best performance in the two feature selection algorithms. The best performance on the test data set was related to Boruta-DT with an average accuracy of 0.86, sensitivity of 1.00, specificity of 0.84, and Area Under the Curve (AUC) of 0.92 (95% CI: 0.92-0.92). Conclusion: Radiomics features have the potential for diagnosing MS active plaque by T2 FLAIR image features. Additionally, choosing the feature selection and classifier algorithms plays an important role in the diagnosis of active plaque in MS patients. The radiomics-based predictive models predict active lesions accurately and non-invasively.
- 9 June 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95  (1136) , 20211253
Deep transfer learning–based fully automated detection and classification of Alzheimer’s disease on brain MRI
Objectives: To employ different automated convolutional neural network (CNN)-based transfer learning (TL) methods for both binary and multiclass classification of Alzheimer’s disease (AD) using brain MRI. Methods: Herein, we applied three popular pre-trained CNN models (ResNet101, Xception, and InceptionV3) using a fine-tuned approach of TL on 3D T 1-weighted brain MRI from a subset of ADNI dataset (n = 305 subjects). To evaluate power of TL, the aforementioned networks were also trained from scratch for performance comparison. Initially, Unet network segmentedthe MRI scans into characteristic components of gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF). The proposed networks were trained and tested over the pre-processed and augmented segmented and whole images for both binary (NC/AD + progressive mild cognitive impairment (pMCI)+stable MCI (sMCI)) and 4-class (AD/pMCI/sMCI/NC) classification. Also, two independent test sets from the OASIS (n = 30) and AIBL (n = 60) datasets were used to externally assess the performance of the proposed algorithms. Results: The proposed TL-based CNN models achieved better performance compared to the training CNN models from scratch. On the ADNI test set, InceptionV3-TL achieved the highest accuracy of 93.75% and AUC of 92.0% for binary classification, as well as the highest accuracy of 93.75% and AUC of 96.0% for multiclass classification of AD on the whole images. On the OASIS test set, InceptionV3-TL outperformed two other models by achieving 93.33% accuracy with 93.0% AUC in binary classification of AD on the whole images. On the AIBL test set, InceptionV3-TL also outperformed two other models in both binary and multiclass classification tasks on the whole MR images and achieved accuracy/AUC of 93.33%/95.0% and 90.0%/93.0%, respectively. The GM segment as input provided the highest performance in both binary and multiclass classification of AD, as compared to the WM and CSF segments. Conclusion: This study demonstrates the potential of applying deep TL approach for automated detection and classification of AD using brain MRI with high accuracy and robustness across internal and external test data, suggesting that these models can possibly be used as a supportive tool to assist clinicians in creating objective opinion and correct diagnosis. Advances in knowledge: We used CNN-based TL approaches and the augmentation techniques to overcome the insufficient data problem. Our study provides evidence that deep TL algorithms can be used for both binary and multiclass classification of AD with high accuracy.
- 9 June 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95  (1136) , 20211253
Deep transfer learning–based fully automated detection and classification of Alzheimer’s disease on brain MRI
Objectives: To employ different automated convolutional neural network (CNN)-based transfer learning (TL) methods for both binary and multiclass classification of Alzheimer’s disease (AD) using brain MRI. Methods: Herein, we applied three popular pre-trained CNN models (ResNet101, Xception, and InceptionV3) using a fine-tuned approach of TL on 3D T 1-weighted brain MRI from a subset of ADNI dataset (n = 305 subjects). To evaluate power of TL, the aforementioned networks were also trained from scratch for performance comparison. Initially, Unet network segmentedthe MRI scans into characteristic components of gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF). The proposed networks were trained and tested over the pre-processed and augmented segmented and whole images for both binary (NC/AD + progressive mild cognitive impairment (pMCI)+stable MCI (sMCI)) and 4-class (AD/pMCI/sMCI/NC) classification. Also, two independent test sets from the OASIS (n = 30) and AIBL (n = 60) datasets were used to externally assess the performance of the proposed algorithms. Results: The proposed TL-based CNN models achieved better performance compared to the training CNN models from scratch. On the ADNI test set, InceptionV3-TL achieved the highest accuracy of 93.75% and AUC of 92.0% for binary classification, as well as the highest accuracy of 93.75% and AUC of 96.0% for multiclass classification of AD on the whole images. On the OASIS test set, InceptionV3-TL outperformed two other models by achieving 93.33% accuracy with 93.0% AUC in binary classification of AD on the whole images. On the AIBL test set, InceptionV3-TL also outperformed two other models in both binary and multiclass classification tasks on the whole MR images and achieved accuracy/AUC of 93.33%/95.0% and 90.0%/93.0%, respectively. The GM segment as input provided the highest performance in both binary and multiclass classification of AD, as compared to the WM and CSF segments. Conclusion: This study demonstrates the potential of applying deep TL approach for automated detection and classification of AD using brain MRI with high accuracy and robustness across internal and external test data, suggesting that these models can possibly be used as a supportive tool to assist clinicians in creating objective opinion and correct diagnosis. Advances in knowledge: We used CNN-based TL approaches and the augmentation techniques to overcome the insufficient data problem. Our study provides evidence that deep TL algorithms can be used for both binary and multiclass classification of AD with high accuracy.
- 15 July 2019
- Published by Springer Nature in Journal of Cancer Research and Clinical Oncology
- Vol. 145  (9) , 2199-2209
Selective radiofrequency ablation of tumor by magnetically targeting of multifunctional iron oxide–gold nanohybrid
Purpose Radiofrequency (RF) ablation therapy is of great interest in cancer therapy as it is non-ionizing radiation and can effectively penetrate into the tissue. However, the current RF ablation technique is invasive that requires RF probe insertion into the tissue and generates a non-specific heating. Recently, RF-responsive nanomaterials such as gold nanoparticles (AuNPs) and iron oxide nanoparticles (IONPs) have led to tremendous progress in this area. They have been found to be able to absorb the RF field and induce a localized heating within the target, thereby affording a non-invasive and tumor-specific RF ablation strategy. In the present study, for the first time, we used a hybrid core-shell nanostructure comprising IONPs as the core and AuNPs as the shell (IO@Au) for targeted RF ablation therapy. Due to the magnetic core, the nanohybrid can be directed toward the tumor through a magnet. Moreover, IONPs enable the nanohybrid to be used as a magnetic resonance imaging (MRI) contrast agent. Results In vitro cytotoxicity experiment showed that the combination of IO@Au and 13.56-MHz RF field significantly reduced the viability of cancer cells. Next, during an in vivo experiment, we demonstrated that magnetically targeting of IO@Au to the tumor and subsequent RF exposure dramatically suppressed the tumor growth. Conclusion Therefore, the integration of targeting, imaging, and therapeutic performances into IO@Au nanohybrid could afford the promise to improve the effectiveness of RF ablation therapy.
- 15 July 2019
- Published by Springer Nature in Journal of Cancer Research and Clinical Oncology
- Vol. 145  (9) , 2199-2209
Selective radiofrequency ablation of tumor by magnetically targeting of multifunctional iron oxide–gold nanohybrid
Purpose Radiofrequency (RF) ablation therapy is of great interest in cancer therapy as it is non-ionizing radiation and can effectively penetrate into the tissue. However, the current RF ablation technique is invasive that requires RF probe insertion into the tissue and generates a non-specific heating. Recently, RF-responsive nanomaterials such as gold nanoparticles (AuNPs) and iron oxide nanoparticles (IONPs) have led to tremendous progress in this area. They have been found to be able to absorb the RF field and induce a localized heating within the target, thereby affording a non-invasive and tumor-specific RF ablation strategy. In the present study, for the first time, we used a hybrid core-shell nanostructure comprising IONPs as the core and AuNPs as the shell (IO@Au) for targeted RF ablation therapy. Due to the magnetic core, the nanohybrid can be directed toward the tumor through a magnet. Moreover, IONPs enable the nanohybrid to be used as a magnetic resonance imaging (MRI) contrast agent. Results In vitro cytotoxicity experiment showed that the combination of IO@Au and 13.56-MHz RF field significantly reduced the viability of cancer cells. Next, during an in vivo experiment, we demonstrated that magnetically targeting of IO@Au to the tumor and subsequent RF exposure dramatically suppressed the tumor growth. Conclusion Therefore, the integration of targeting, imaging, and therapeutic performances into IO@Au nanohybrid could afford the promise to improve the effectiveness of RF ablation therapy.
- Open Access
- 1 August 2017
- Vol. 20  (8) , 951-957
Role of basal stress hormones and amygdala dimensions in stress coping strategies of male rhesus monkeys in response to a hazard-reward conflict
- 1 August 2017
- Vol. 20  (8) , 951-957
Open AccessRole of basal stress hormones and amygdala dimensions in stress coping strategies of male rhesus monkeys in response to a hazard-reward conflict
- 1 August 2015
- Published by Elsevier in Bioelectrochemistry
- Vol. 104, 79-84
Measuring hydrogen peroxide due to water radiolysis using a modified horseradish peroxidase based biosensor as an alternative dosimetry method
- 1 August 2015
- Published by Elsevier in Bioelectrochemistry
- Vol. 104, 79-84
Measuring hydrogen peroxide due to water radiolysis using a modified horseradish peroxidase based biosensor as an alternative dosimetry method