Tahsin Reasat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tahsin Reasat has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Benoit M. Dawant
Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
2 shared publications - Eric R. Tkaczyk
Vanderbilt University Medical Center
2 shared publications - Inga Saknite
University of Latvia
2 shared publications - Kelsey Parks
Department of Dermatology Vanderbilt University Medical Center Nashville, TN United States
2 shared publications - Xiaoqi Liu
Department of Dermatology Vanderbilt University Medical Center Nashville, TN United States
2 shared publications Abir Saha
Department of Electrical and Computer Engineering Indiana University—Purdue University Indianapolis 723 West Michigan Street Indianapolis 46202 IN USA
1 shared publication
Latest Publications
- Open Access
- 22 July 2024
- Published by Elsevier in Machine Learning with Applications
- Vol. 17
Data efficient contrastive learning in histopathology using active sampling
- 22 July 2024
- Published by Elsevier in Machine Learning with Applications
- Vol. 17
Open AccessData efficient contrastive learning in histopathology using active sampling
- 7 November 2022
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 36 (1) , 373-378
Non-Expert Markings of Active Chronic Graft-Versus-Host Disease Photographs: Optimal Metrics of Training Effects
Lack of reliable measures of cutaneous chronic graft-versus-host disease (cGVHD) remains a significant challenge. Non-expert assistance in marking photographs of active disease could aid the development of automated segmentation algorithms, but validated metrics to evaluate training effects are lacking. We studied absolute and relative error of marked body surface area (BSA), redness, and the Dice index as potential metrics of non-expert improvement. Three non-experts underwent an extensive training program led by a board-certified dermatologist to mark cGVHD in photographs. At the end of the 4-month training, the dermatologist confirmed that each trainee had learned to accurately mark cGVHD. The trainees’ inter- and intra-rater intraclass correlation coefficient estimates were “substantial” to “almost perfect” for both BSA and total redness. For fifteen 3D photos of patients with cGVHD, the trainees’ median absolute (relative) BSA error compared to expert marking dropped from 20 cm2 (29%) pre-training to 14 cm2 (24%) post-training. Total redness error decreased from 122 a*·cm2 (26%) to 95 a*·cm2 (21%). By contrast, median Dice index did not reflect improvement (0.76 to 0.75). Both absolute and relative BSA and redness errors similarly and stably reflected improvements from this training program, which the Dice index failed to capture.
- 7 November 2022
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 36 (1) , 373-378
Non-Expert Markings of Active Chronic Graft-Versus-Host Disease Photographs: Optimal Metrics of Training Effects
Lack of reliable measures of cutaneous chronic graft-versus-host disease (cGVHD) remains a significant challenge. Non-expert assistance in marking photographs of active disease could aid the development of automated segmentation algorithms, but validated metrics to evaluate training effects are lacking. We studied absolute and relative error of marked body surface area (BSA), redness, and the Dice index as potential metrics of non-expert improvement. Three non-experts underwent an extensive training program led by a board-certified dermatologist to mark cGVHD in photographs. At the end of the 4-month training, the dermatologist confirmed that each trainee had learned to accurately mark cGVHD. The trainees’ inter- and intra-rater intraclass correlation coefficient estimates were “substantial” to “almost perfect” for both BSA and total redness. For fifteen 3D photos of patients with cGVHD, the trainees’ median absolute (relative) BSA error compared to expert marking dropped from 20 cm2 (29%) pre-training to 14 cm2 (24%) post-training. Total redness error decreased from 122 a*·cm2 (26%) to 95 a*·cm2 (21%). By contrast, median Dice index did not reflect improvement (0.76 to 0.75). Both absolute and relative BSA and redness errors similarly and stably reflected improvements from this training program, which the Dice index failed to capture.
- 24 March 2022
- Published by Wiley in British Journal of Haematology
- Vol. 197 (6) , e69-e72
Artificial intelligence recognition of cutaneous chronic graft‐versus‐host disease by a deep learning neural network
- 24 March 2022
- Published by Wiley in British Journal of Haematology
- Vol. 197 (6) , e69-e72
Artificial intelligence recognition of cutaneous chronic graft‐versus‐host disease by a deep learning neural network
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 718-721
Detection of inferior myocardial infarction using shallow convolutional neural networks
Myocardial Infarction is one of the leading causes of death worldwide. This paper presents a Convolutional Neural Network (CNN) architecture which takes raw Electrocardiography (ECG) signal from lead II, III and AVF and differentiates between inferior myocardial infarction (IMI) and healthy signals. The performance of the model is evaluated on IMI and healthy signals obtained from Physikalisch-Technische Bundesanstalt (PTB) database. A subject-oriented approach is taken to comprehend the generalization capability of the model and compared with the current state of the art. In a subject-oriented approach, the network is tested on one patient and trained on rest of the patients. Our model achieved a superior metrics scores (accuracy= 84.54%, sensitivity= 85.33% and specificity= 84.09%) when compared to the benchmark. We also analyzed the discriminating strength of the features extracted by the convolutional layers by means of geometric separability index and euclidean distance and compared it with the benchmark model.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 718-721
Detection of inferior myocardial infarction using shallow convolutional neural networks
Myocardial Infarction is one of the leading causes of death worldwide. This paper presents a Convolutional Neural Network (CNN) architecture which takes raw Electrocardiography (ECG) signal from lead II, III and AVF and differentiates between inferior myocardial infarction (IMI) and healthy signals. The performance of the model is evaluated on IMI and healthy signals obtained from Physikalisch-Technische Bundesanstalt (PTB) database. A subject-oriented approach is taken to comprehend the generalization capability of the model and compared with the current state of the art. In a subject-oriented approach, the network is tested on one patient and trained on rest of the patients. Our model achieved a superior metrics scores (accuracy= 84.54%, sensitivity= 85.33% and specificity= 84.09%) when compared to the benchmark. We also analyzed the discriminating strength of the features extracted by the convolutional layers by means of geometric separability index and euclidean distance and compared it with the benchmark model.
- 20 March 2017
- Published by Wiley in International Journal of Communication Systems
- Vol. 30 (16)
Cognitive radio network with coordinated multipoint joint transmission
Summary: Cognitive radio (CR) is considered to be a promising technology for future wireless networks to make opportunistic utilization of the unused or underused licensed spectrum. Meanwhile, coordinated multipoint joint transmission (CoMP JT) is another promising technique to improve the performance of cellular networks. In this paper, we propose a CR system with CoMP JT technique. We develop an analytical model of the received signal‐to‐noise ratio at a CR to determine the energy detection threshold and the minimum number of required samples for energy detection–based spectrum sensing in a CR network (CRN) with CoMP JT technique. The performance of energy detection–based spectrum sensing under the developed analytical model is evaluated by simulation and found to be reliable. We formulate an optimization problem for a CRN with CoMP JT technique to configure the channel allocation and user scheduling for maximizing the minimum throughput of the users. The problem is found to be a complex mixed integer linear programming. We solve the problem using an optimization tool for several CRN instances by limiting the number of slots in frames. Further, we propose a heuristic‐based simple channel allocation and user scheduling algorithm to maximize the minimum throughput of the users in CRNs with CoMP JT technique. The proposed algorithm is evaluated via simulation and found to be very efficient.
- 20 March 2017
- Published by Wiley in International Journal of Communication Systems
- Vol. 30 (16)
Cognitive radio network with coordinated multipoint joint transmission
Summary: Cognitive radio (CR) is considered to be a promising technology for future wireless networks to make opportunistic utilization of the unused or underused licensed spectrum. Meanwhile, coordinated multipoint joint transmission (CoMP JT) is another promising technique to improve the performance of cellular networks. In this paper, we propose a CR system with CoMP JT technique. We develop an analytical model of the received signal‐to‐noise ratio at a CR to determine the energy detection threshold and the minimum number of required samples for energy detection–based spectrum sensing in a CR network (CRN) with CoMP JT technique. The performance of energy detection–based spectrum sensing under the developed analytical model is evaluated by simulation and found to be reliable. We formulate an optimization problem for a CRN with CoMP JT technique to configure the channel allocation and user scheduling for maximizing the minimum throughput of the users. The problem is found to be a complex mixed integer linear programming. We solve the problem using an optimization tool for several CRN instances by limiting the number of slots in frames. Further, we propose a heuristic‐based simple channel allocation and user scheduling algorithm to maximize the minimum throughput of the users in CRNs with CoMP JT technique. The proposed algorithm is evaluated via simulation and found to be very efficient.