Prajwal Shenoy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Prajwal Shenoy has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Varadhan Skm
Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras, Chennai, India
3 shared publications - Nithesh Naik
Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India
2 shared publications - Anurag Gupta
Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu, India
1 shared publication Chandrasekhar Bhat
Manipal University
1 shared publicationDebarghya
1 shared publicationFaber Saldanha
Tata Consultancy Services
1 shared publication
Latest Publications
- Open Access
- 24 May 2026
- Published by Elsevier in Results in Engineering
- Vol. 30
Dual-task interference does not invoke mechanical advantage during multi-finger dexterous object manipulation
- 24 May 2026
- Published by Elsevier in Results in Engineering
- Vol. 30
Open AccessDual-task interference does not invoke mechanical advantage during multi-finger dexterous object manipulation
- Open Access
- 4 December 2025
- Published by Elsevier in Results in Engineering
- Vol. 29
Bimanual finger synergies reveal no functional asymmetry between hands
- 4 December 2025
- Published by Elsevier in Results in Engineering
- Vol. 29
Open AccessBimanual finger synergies reveal no functional asymmetry between hands
- Open Access
- 8 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. PP, 1
Design and Validation of an IMU based Handpiece Angulation Measurement System for Guided Dental Implant Surgery
Dental implants are an effective solution for tooth loss, offering long-term success rates exceeding 95%. However, challenges such as surgical complications, improper implant position, and prosthetic inaccuracies persists, often due to operator inexperience or anatomical complexities. Previously, Static Computer-Assisted Implant Surgery (sCAIS) and Dynamic Navigation Systems (DNS) have shown improved precision in implant placement. However, sCAIS often incurs high costs and manufacturing delays, while DNS faces challenges like line-of-sight issues and magnetic interference. Inertial measurement units (IMUs) present a promising alternative, offering real-time orientation feedback with advantages such as low cost, portability, and no line-of-sight restrictions. Despite their potential, research on IMU-based guidance for dental implant placement is limited, with unresolved issues related to accuracy under drilling vibrations, device miniaturization, and clinical usability. This paper presents the design and validation of a compact IMU-based system that measures handpiece angulation in real-time, transmitting mesiodistal and buccolingual orientation data to a wireless clinician-worn watch. A thorough validation was conducted to measure both the static and dynamic accuracies, as well as the response time of the system when exposed to dental handpiece drill vibrations. The impact of the built-in filtering features of the IMU and various tuning parameters on performance was also assessed. The validation results indicate that the IMU-assisted implantology device is a cost-effective and adaptable solution for precise implant placement.
- 8 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. PP, 1
Open AccessDesign and Validation of an IMU based Handpiece Angulation Measurement System for Guided Dental Implant Surgery
Dental implants are an effective solution for tooth loss, offering long-term success rates exceeding 95%. However, challenges such as surgical complications, improper implant position, and prosthetic inaccuracies persists, often due to operator inexperience or anatomical complexities. Previously, Static Computer-Assisted Implant Surgery (sCAIS) and Dynamic Navigation Systems (DNS) have shown improved precision in implant placement. However, sCAIS often incurs high costs and manufacturing delays, while DNS faces challenges like line-of-sight issues and magnetic interference. Inertial measurement units (IMUs) present a promising alternative, offering real-time orientation feedback with advantages such as low cost, portability, and no line-of-sight restrictions. Despite their potential, research on IMU-based guidance for dental implant placement is limited, with unresolved issues related to accuracy under drilling vibrations, device miniaturization, and clinical usability. This paper presents the design and validation of a compact IMU-based system that measures handpiece angulation in real-time, transmitting mesiodistal and buccolingual orientation data to a wireless clinician-worn watch. A thorough validation was conducted to measure both the static and dynamic accuracies, as well as the response time of the system when exposed to dental handpiece drill vibrations. The impact of the built-in filtering features of the IMU and various tuning parameters on performance was also assessed. The validation results indicate that the IMU-assisted implantology device is a cost-effective and adaptable solution for precise implant placement.
- Open Access
- 23 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-15
Exploring synergistic patterns in bimanual distal limb movements through low dimensional representations
The human hand is a complex manipulator with many joints that can perform various tasks. Neuroscience research has demonstrated that to perform any posture, the brain does not control the individual joints but relies on coactivation patterns called synergies that simultaneously control a set of joints. A combination of these synergies can then be used to reconstruct a variety of postures. While such a hypothesis has been demonstrated for single-handed tasks, a question that is not well-explored is whether such synergies can simultaneously control the joints of both hands during bimanual tasks. This paper attempted to address this question by exploring synergies obtained by performing Principal Component Analysis (PCA) on the kinematic data recorded from both the dominant and non-dominant hands of the participants as they performed bimanual tasks. The ability of synergies to reconstruct postures from a lower-dimensional subspace was presented, and an analysis of the separability of postures was performed using a classification algorithm. The results showed that the first 3 synergies explained greater than 80% variance in data, indicating that a few bimanual synergies can be utilized to control the fingers of both hands. The first three synergies could reconstruct postures with a Root Mean Square Error (RMSE) of 4° and classify tasks with an accuracy of 90%, demonstrating that the task-related information was retained in the lower dimensional subspace. This could significantly reduce control complexities while designing robotic or prosthetic distal upper limb devices.
- 23 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-15
Open AccessExploring synergistic patterns in bimanual distal limb movements through low dimensional representations
The human hand is a complex manipulator with many joints that can perform various tasks. Neuroscience research has demonstrated that to perform any posture, the brain does not control the individual joints but relies on coactivation patterns called synergies that simultaneously control a set of joints. A combination of these synergies can then be used to reconstruct a variety of postures. While such a hypothesis has been demonstrated for single-handed tasks, a question that is not well-explored is whether such synergies can simultaneously control the joints of both hands during bimanual tasks. This paper attempted to address this question by exploring synergies obtained by performing Principal Component Analysis (PCA) on the kinematic data recorded from both the dominant and non-dominant hands of the participants as they performed bimanual tasks. The ability of synergies to reconstruct postures from a lower-dimensional subspace was presented, and an analysis of the separability of postures was performed using a classification algorithm. The results showed that the first 3 synergies explained greater than 80% variance in data, indicating that a few bimanual synergies can be utilized to control the fingers of both hands. The first three synergies could reconstruct postures with a Root Mean Square Error (RMSE) of 4° and classify tasks with an accuracy of 90%, demonstrating that the task-related information was retained in the lower dimensional subspace. This could significantly reduce control complexities while designing robotic or prosthetic distal upper limb devices.
- Open Access
- 26 October 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-12
Task demands modulate distal limb handedness: A comparative analysis of prehensile synergies of the dominant and non-dominant hand
The dynamic dominance hypothesis of handedness suggests a distinct control strategy for the dominant and the non-dominant limb. The hypothesis demonstrated that the dominant proximal limb is tuned for optimal trajectory control while the non-dominant limb is tuned for a stable grasp. Whether the hypothesis can be extended to distal segments like fingers, especially during a five-fingered grasp, has been studied little. To examine this, an attempt was made to compare the prehensile synergies and force magnitudes of the dominant (DOM) and non-dominant hands (NDOM) during a 5-fingered prehension task. Participants traced a trapezoidal and inverse trapezoidal path with their thumbs on a sliding platform while holding a handle in static equilibrium. The DOM hand performed better only in the inverse trapezoid condition, exhibiting a reduced grip force and increased synergy index aligning with the dynamic dominance hypothesis. No differences were observed for the trapezoid condition, likely due to reduced task demands. The study also explored changes in anticipatory synergy adjustments between the DOM and NDOM hands, but the differences were non-significant. Overall, the DOM hand demonstrated better force coordination than the NDOM hand in challenging conditions. Applications of the study in the objective assessment of handedness were proposed.
- 26 October 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-12
Open AccessTask demands modulate distal limb handedness: A comparative analysis of prehensile synergies of the dominant and non-dominant hand
The dynamic dominance hypothesis of handedness suggests a distinct control strategy for the dominant and the non-dominant limb. The hypothesis demonstrated that the dominant proximal limb is tuned for optimal trajectory control while the non-dominant limb is tuned for a stable grasp. Whether the hypothesis can be extended to distal segments like fingers, especially during a five-fingered grasp, has been studied little. To examine this, an attempt was made to compare the prehensile synergies and force magnitudes of the dominant (DOM) and non-dominant hands (NDOM) during a 5-fingered prehension task. Participants traced a trapezoidal and inverse trapezoidal path with their thumbs on a sliding platform while holding a handle in static equilibrium. The DOM hand performed better only in the inverse trapezoid condition, exhibiting a reduced grip force and increased synergy index aligning with the dynamic dominance hypothesis. No differences were observed for the trapezoid condition, likely due to reduced task demands. The study also explored changes in anticipatory synergy adjustments between the DOM and NDOM hands, but the differences were non-significant. Overall, the DOM hand demonstrated better force coordination than the NDOM hand in challenging conditions. Applications of the study in the objective assessment of handedness were proposed.
- Open Access
- 31 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 93812-93830
Design and Validation of an IMU Based Full Hand Kinematic Measurement System
Measurement of hand kinematics is commonly done using data gloves and optical trackers and finds application in biomechanics, motor control research, clinical assessment, virtual reality etc. While data gloves are expensive and restrict the dexterity of the hand, optical trackers are susceptible to the line-of-sight problem and can be used only in a laboratory setting. Over the last decade, the use of Inertial Measurement Units (IMUs) to measure kinematics has gained traction due to their affordability and good accuracy. This paper presents the design and validation of a BNO055 IMU-based full Hand Kinematics Measurement System (HKMS). The best features from existing IMU-based devices were identified from the literature and incorporated. The HKMS streams orientation information of 16 BNO055 IMUs in real-time at 100 Hz via Wi-Fi or USB. A rigorous static and dynamic validation of the BNO055 IMU was done against 3D printed models and the highly accurate Electro Magnetic Tracking System (EMTS). The RMSE errors were found to be acceptable for the measurement of hand kinematics. Two experiments were conducted to collect hand kinematic data for various postures and object grasps using the HKMS and EMTS, respectively. Synergy analysis was done and range of motion of the joints was calculated using the two datasets. The results were compared to get an idea of the quality of the dataset collected using the HKMS. The results as well as the overall validation of the sensors indicate that the HKMS may be suitable for usage in a laboratory or clinical setup.
- 31 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 93812-93830
Open AccessDesign and Validation of an IMU Based Full Hand Kinematic Measurement System
Measurement of hand kinematics is commonly done using data gloves and optical trackers and finds application in biomechanics, motor control research, clinical assessment, virtual reality etc. While data gloves are expensive and restrict the dexterity of the hand, optical trackers are susceptible to the line-of-sight problem and can be used only in a laboratory setting. Over the last decade, the use of Inertial Measurement Units (IMUs) to measure kinematics has gained traction due to their affordability and good accuracy. This paper presents the design and validation of a BNO055 IMU-based full Hand Kinematics Measurement System (HKMS). The best features from existing IMU-based devices were identified from the literature and incorporated. The HKMS streams orientation information of 16 BNO055 IMUs in real-time at 100 Hz via Wi-Fi or USB. A rigorous static and dynamic validation of the BNO055 IMU was done against 3D printed models and the highly accurate Electro Magnetic Tracking System (EMTS). The RMSE errors were found to be acceptable for the measurement of hand kinematics. Two experiments were conducted to collect hand kinematic data for various postures and object grasps using the HKMS and EMTS, respectively. Synergy analysis was done and range of motion of the joints was calculated using the two datasets. The results were compared to get an idea of the quality of the dataset collected using the HKMS. The results as well as the overall validation of the sensors indicate that the HKMS may be suitable for usage in a laboratory or clinical setup.
- Open Access
- 18 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 42673-42689
Methods for Measurement and Analysis of Full Hand Angular Kinematics Using Electromagnetic Tracking Sensors
The human hand needs a large number of sensors to measure kinematics owing to its large number of degrees of freedom. Existing devices like data gloves and optical trackers are associated with calibration, line of sight, and accuracy problems. In this paper, we attempt to measure the full hand kinematics using Electromagnetic Tracking Sensors (EMTS) which are accurate, free of line-of-sight problems, and require no calibration. However, EMTS provides output in the form of rotation groups which are defined on a nonlinear manifold. Hence, linear operations required for experimental analysis such as linear dimensionality reduction are not valid. Also, these sensors are expensive, utilize space in terms of cabling, and require a reduced sensor layout. In this paper, we present measurement methods, test the utility of linear and non-linear dimensionality reduction techniques on quaternions and exponential maps. We also performed sensor reduction using a Gini feature selection based on random forest algorithm. The kinematic measurement results show that EMTS yield superior posture reproduction with an error of less than 1 degree. Autoencoder, a nonlinear dimensionality reduction technique, was successfully applied on quaternions which was tuned to perform better than Principal Component Analysis (PCA) in reducing dimensions. The reduced sensor layout with 8 sensors was able to predict full hand kinematics with a Root Mean Square Error (RMSE) of 5.1 degrees.
- 18 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 42673-42689
Open AccessMethods for Measurement and Analysis of Full Hand Angular Kinematics Using Electromagnetic Tracking Sensors
The human hand needs a large number of sensors to measure kinematics owing to its large number of degrees of freedom. Existing devices like data gloves and optical trackers are associated with calibration, line of sight, and accuracy problems. In this paper, we attempt to measure the full hand kinematics using Electromagnetic Tracking Sensors (EMTS) which are accurate, free of line-of-sight problems, and require no calibration. However, EMTS provides output in the form of rotation groups which are defined on a nonlinear manifold. Hence, linear operations required for experimental analysis such as linear dimensionality reduction are not valid. Also, these sensors are expensive, utilize space in terms of cabling, and require a reduced sensor layout. In this paper, we present measurement methods, test the utility of linear and non-linear dimensionality reduction techniques on quaternions and exponential maps. We also performed sensor reduction using a Gini feature selection based on random forest algorithm. The kinematic measurement results show that EMTS yield superior posture reproduction with an error of less than 1 degree. Autoencoder, a nonlinear dimensionality reduction technique, was successfully applied on quaternions which was tuned to perform better than Principal Component Analysis (PCA) in reducing dimensions. The reduced sensor layout with 8 sensors was able to predict full hand kinematics with a Root Mean Square Error (RMSE) of 5.1 degrees.
- Open Access
- 20 April 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (2.21) , 1-4
Design and development of a novel triphibian quadcopter
Design and development of a novel triphibian quadcopter
- 20 April 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (2.21) , 1-4
Open AccessDesign and development of a novel triphibian quadcopter
Design and development of a novel triphibian quadcopter
- Open Access
- 9 January 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 144, 01014
Design and Analysis of Split Fixture for Gear Hobbing Machine
Compared to the conventional gear hobbing fixtures, split fixture can effectively reduce job set-up time during the manufacturing process. This paper investigates the behaviour and analysis of split fixture under varying static loading conditions. Design of the part was established by considering the ability of the split fixture to carry jobs of various diameters. In order to validate the design, Static structural analysis was carried out on two positional configurations of the split fixture. A load of 1 ton was applied on the resting face of the fixture to simulate the effect of holding the job. The analysis included a study of the Stress, Deformations, and Modal analysis at different resonating frequencies to check for failure of design. By applying varying loads similar to practical conditions, it was observed that the design successfully withstood the applied forces without failure and a factor of safety of 142 was achieved in a critical loading case. Investigating the effect of dynamic loads on the Split Fixture and including auxiliary assembly components in design analysis.
- 9 January 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 144, 01014
Open AccessDesign and Analysis of Split Fixture for Gear Hobbing Machine
Compared to the conventional gear hobbing fixtures, split fixture can effectively reduce job set-up time during the manufacturing process. This paper investigates the behaviour and analysis of split fixture under varying static loading conditions. Design of the part was established by considering the ability of the split fixture to carry jobs of various diameters. In order to validate the design, Static structural analysis was carried out on two positional configurations of the split fixture. A load of 1 ton was applied on the resting face of the fixture to simulate the effect of holding the job. The analysis included a study of the Stress, Deformations, and Modal analysis at different resonating frequencies to check for failure of design. By applying varying loads similar to practical conditions, it was observed that the design successfully withstood the applied forces without failure and a factor of safety of 142 was achieved in a critical loading case. Investigating the effect of dynamic loads on the Split Fixture and including auxiliary assembly components in design analysis.
- 1 August 2013
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 367, 204-208
Simulation of Contact Bouncing Behavior in Starter Solenoid and Exploring Potential Feasible Solution
In this paper, investigation on starter solenoid to develop a generalized model based simulation methodology to simulate contact bounce characteristics and tuning of the parameters to reduce or eliminate the contact bounce in existing solenoids complying with all functional and cost constraints. Using the measured data, a generalized model based simulation methodology is built using Matlab Simulink to establish contact bouncing characteristics, which is highly non-linear in nature, under various conditions/parametric variations like electromagnetic force, air gap, hard stops, spring rate and mass. The simulation model reveals that the contact bounce is reduced to zero when the stiffness of the spindle spring is in the range of 1050 N/m to 1250 N/m. Thus we can conclude that the methodology adopted helps in understanding the characteristics of existing solenoids and providing practical suggestions for potential feasible modifications that can be incorporated in the existing solenoids so as to tune their physical system parameters for an optimum response.
- 1 August 2013
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 367, 204-208
Simulation of Contact Bouncing Behavior in Starter Solenoid and Exploring Potential Feasible Solution
In this paper, investigation on starter solenoid to develop a generalized model based simulation methodology to simulate contact bounce characteristics and tuning of the parameters to reduce or eliminate the contact bounce in existing solenoids complying with all functional and cost constraints. Using the measured data, a generalized model based simulation methodology is built using Matlab Simulink to establish contact bouncing characteristics, which is highly non-linear in nature, under various conditions/parametric variations like electromagnetic force, air gap, hard stops, spring rate and mass. The simulation model reveals that the contact bounce is reduced to zero when the stiffness of the spindle spring is in the range of 1050 N/m to 1250 N/m. Thus we can conclude that the methodology adopted helps in understanding the characteristics of existing solenoids and providing practical suggestions for potential feasible modifications that can be incorporated in the existing solenoids so as to tune their physical system parameters for an optimum response.