Stefano Roccella
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Stefano Roccella has a total of 132 co-authors. Here are the top co-authors by number of shared publications:
- Maria Chiara Carrozza
The BioRobotics Institute, Scuola Superiore Sant’Anna, Pontedera, Italy
33 shared publications P. Dario
ARTS Lab, Scuola Superiore Sant'Anna, viale R. Piaggio 34, 56025 Pontedera, Pisa Italy
13 shared publications- Lucia Beccai
Soft BioRobotics Perception Lab Istituto Italiano di Tecnologia Genova Italy
10 shared publications Nicola Vitiello
The BioRobotics Institute, Scuola Superiore Sant’Anna
10 shared publications- Tommaso Lenzi
Department of Mechanical Engineering at the University of Utah, Salt Lake City, USA
10 shared publications F. Vecchi
The BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy
8 shared publications
Latest Publications
- 23 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 19 (3) , 1691-1706
An Autonomous Robotic Platform for Manipulation and Inspection of Metallic Surfaces in Industry 4.0
Quality control in industry involves trained operators to manipulate and inspect metallic surfaces in order to identify, and eventually correct, manufacturing defects. These tasks are manually performed, and a poor performance (e.g., missing defects) leads to an increase of the costs and prolongation of the manufacturing time cycle. In this work, we propose a multi-agent robotic platform to autonomously perform Industry 4.0 quality control processes of metallic surfaces. The platform consists of three anthropomorphic robots with custom-made end-effectors designed to manipulate, inspect, and eventually correct a metallic frame of a motorcycle. The description of a novel multi-agent platform is followed by the presentation of the developed inspection procedure, in which a linear laser scanner is used to reconstruct the three-dimensional metallic surface of a motorcycle with a resolution of ~0.1 mm. In order to validate the platform, we perform a set of experiments to assess the performance of the robotic platform in a real Industry 4.0 scenario. Results confirmed that such a system guarantees a sub-millimetric precision to identify defects on complex-shaped metallic surfaces and effectively correct them. The proposed robotic platform can be adopted for overcoming the drawbacks of a traditional procedure that relies on visual-tactile manual defects correction (e.g., low-repeatability, high-subjectivity) and is scalable to different industrial applications. The proposed approach aims to elevate the role of operators to expert supervisors of the process, limiting the interactions with potentially-dangerous tools/procedures and thus improving the working conditions in an industrial 4.0 scenario.
- 23 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 19 (3) , 1691-1706
An Autonomous Robotic Platform for Manipulation and Inspection of Metallic Surfaces in Industry 4.0
Quality control in industry involves trained operators to manipulate and inspect metallic surfaces in order to identify, and eventually correct, manufacturing defects. These tasks are manually performed, and a poor performance (e.g., missing defects) leads to an increase of the costs and prolongation of the manufacturing time cycle. In this work, we propose a multi-agent robotic platform to autonomously perform Industry 4.0 quality control processes of metallic surfaces. The platform consists of three anthropomorphic robots with custom-made end-effectors designed to manipulate, inspect, and eventually correct a metallic frame of a motorcycle. The description of a novel multi-agent platform is followed by the presentation of the developed inspection procedure, in which a linear laser scanner is used to reconstruct the three-dimensional metallic surface of a motorcycle with a resolution of ~0.1 mm. In order to validate the platform, we perform a set of experiments to assess the performance of the robotic platform in a real Industry 4.0 scenario. Results confirmed that such a system guarantees a sub-millimetric precision to identify defects on complex-shaped metallic surfaces and effectively correct them. The proposed robotic platform can be adopted for overcoming the drawbacks of a traditional procedure that relies on visual-tactile manual defects correction (e.g., low-repeatability, high-subjectivity) and is scalable to different industrial applications. The proposed approach aims to elevate the role of operators to expert supervisors of the process, limiting the interactions with potentially-dangerous tools/procedures and thus improving the working conditions in an industrial 4.0 scenario.
- Open Access
- 1 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Field Robotics
- Vol. 1, 1-31
Design and Development of Drones to Autonomously Interact with Objects in Unstructured Outdoor Scenarios
- 1 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Field Robotics
- Vol. 1, 1-31
Open AccessDesign and Development of Drones to Autonomously Interact with Objects in Unstructured Outdoor Scenarios
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
InGene: a multimodal approach to the genotype-phenotype association in neuromuscular diseases
Neuromuscular Diseases require a careful study of the genotype-phenotype association in order to be properly diagnosed and to undertake a personalized, efficient treatment planning. To this extent, the merging of genetic, instrumental, muscular, physiotherapy, cardiovascular data is pivotal to define the profile of each single patient and to help the clinicians in defining treatment plans, monitoring the pathological course and, finally, in the patients' care. In this document, we briefly describe the in-progress development of a multimodal approach addressing this topic, focusing on the solutions composing the relevant platform as a whole, adding some brief cues on the future steps to complete the implementation of such solution and providing short hints about its possible future use.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
InGene: a multimodal approach to the genotype-phenotype association in neuromuscular diseases
Neuromuscular Diseases require a careful study of the genotype-phenotype association in order to be properly diagnosed and to undertake a personalized, efficient treatment planning. To this extent, the merging of genetic, instrumental, muscular, physiotherapy, cardiovascular data is pivotal to define the profile of each single patient and to help the clinicians in defining treatment plans, monitoring the pathological course and, finally, in the patients' care. In this document, we briefly describe the in-progress development of a multimodal approach addressing this topic, focusing on the solutions composing the relevant platform as a whole, adding some brief cues on the future steps to complete the implementation of such solution and providing short hints about its possible future use.
- Open Access
- 1 December 2016
- Published by SAGE Publications in International Journal of Advanced Robotic Systems
- Vol. 13 (6)
A novel shared control algorithm for industrial robots
Human management of robots in many specific industrial activities has long been imperative, due to the elevated levels of complexity involved, which can only be overcome through long and wasteful preprogrammed activities. The shared control approach is one of the most emergent procedures that can compensate and optimally couple human smartness with the high precision and productivity characteristic to mechatronic systems. To explore and to exploit this approach in the industrial field, an innovative shared control algorithm was elaborated, designed and validated in a specific case study.
- 1 December 2016
- Published by SAGE Publications in International Journal of Advanced Robotic Systems
- Vol. 13 (6)
Open AccessA novel shared control algorithm for industrial robots
Human management of robots in many specific industrial activities has long been imperative, due to the elevated levels of complexity involved, which can only be overcome through long and wasteful preprogrammed activities. The shared control approach is one of the most emergent procedures that can compensate and optimally couple human smartness with the high precision and productivity characteristic to mechatronic systems. To explore and to exploit this approach in the industrial field, an innovative shared control algorithm was elaborated, designed and validated in a specific case study.
- 1 January 2016
- Published by ACTA Press
A Novel Haptic Interface Control System for Robotic Industrial Processes
This paper presents a novel haptic interface control system for robotic industrial processes.
- 1 January 2016
- Published by ACTA Press
A Novel Haptic Interface Control System for Robotic Industrial Processes
This paper presents a novel haptic interface control system for robotic industrial processes.
- 1 January 2015
- Published by Springer Nature
- p. 1-40
Neuro-robotics Paradigm for Intelligent Assistive Technologies
- 1 January 2015
- Published by Springer Nature
- p. 1-40
Neuro-robotics Paradigm for Intelligent Assistive Technologies
- 1 January 2014
- Published by ACTA Press
A Design Paradigm for the Development of Advanced Operating Rooms
- 1 January 2014
- Published by ACTA Press
A Design Paradigm for the Development of Advanced Operating Rooms
- Open Access
- 19 June 2013
- Published by Wiley in Journal of Field Robotics
- Vol. 30 (5) , 832
The ESA Lunar Robotics Challenge: Simulating Operations at the Lunar South Pole
- 19 June 2013
- Published by Wiley in Journal of Field Robotics
- Vol. 30 (5) , 832
Open AccessThe ESA Lunar Robotics Challenge: Simulating Operations at the Lunar South Pole
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 17 (5) , 884-894
Mechatronic Design and Characterization of the Index Finger Module of a Hand Exoskeleton for Post-Stroke Rehabilitation
This paper presents HANDEXOS, a novel wearable multiphalanges device for post-stroke rehabilitation. It was designed in order to allow for a functional and safe interaction with the user's hand by means of an anthropomorphic kinematics and the minimization of the human/exoskeleton rotational axes misalignment. This paper describes the mechatronic design of the exoskeleton's index finger module, simulation, modeling, and development of the actuation unit and sensory system. Experimental results on the validation of the dynamic model and experimental characterization of the index finger module with healthy subjects are reported, showing promising results that encourage further clinical trials.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 17 (5) , 884-894
Mechatronic Design and Characterization of the Index Finger Module of a Hand Exoskeleton for Post-Stroke Rehabilitation
This paper presents HANDEXOS, a novel wearable multiphalanges device for post-stroke rehabilitation. It was designed in order to allow for a functional and safe interaction with the user's hand by means of an anthropomorphic kinematics and the minimization of the human/exoskeleton rotational axes misalignment. This paper describes the mechatronic design of the exoskeleton's index finger module, simulation, modeling, and development of the actuation unit and sensory system. Experimental results on the validation of the dynamic model and experimental characterization of the index finger module with healthy subjects are reported, showing promising results that encourage further clinical trials.
- 17 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 29 (1) , 220-235
NEUROExos: A Powered Elbow Exoskeleton for Physical Rehabilitation
This paper presents the design and experimental testing of the robotic elbow exoskeleton NEUROBOTICS Elbow Exoskeleton (NEUROExos). The design of NEUROExos focused on three solutions that enable its use for poststroke physical rehabilitation. First, double-shelled links allow an ergonomic physical human-robot interface and, consequently, a comfortable interaction. Second, a four-degree-of-freedom passive mechanism, embedded in the link, allows the user's elbow and robot axes to be constantly aligned during movement. The robot axis can passively rotate on the frontal and horizontal planes 30° and 40°, respectively, and translate on the horizontal plane 30 mm. Finally, a variable impedance antagonistic actuation system allows NEUROExos to be controlled with two alternative strategies: independent control of the joint position and stiffness, for robot-in-charge rehabilitation mode, and near-zero impedance torque control, for patient-in-charge rehabilitation mode. In robot-in-charge mode, the passive joint stiffness can be changed in the range of 24-56 N·m/rad. In patient-in-charge mode, NEUROExos output impedance ranges from 1 N·m/rad, for 0.3 Hz motion, to 10 N·m/rad, for 3.2 Hz motion.
- 17 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 29 (1) , 220-235
NEUROExos: A Powered Elbow Exoskeleton for Physical Rehabilitation
This paper presents the design and experimental testing of the robotic elbow exoskeleton NEUROBOTICS Elbow Exoskeleton (NEUROExos). The design of NEUROExos focused on three solutions that enable its use for poststroke physical rehabilitation. First, double-shelled links allow an ergonomic physical human-robot interface and, consequently, a comfortable interaction. Second, a four-degree-of-freedom passive mechanism, embedded in the link, allows the user's elbow and robot axes to be constantly aligned during movement. The robot axis can passively rotate on the frontal and horizontal planes 30° and 40°, respectively, and translate on the horizontal plane 30 mm. Finally, a variable impedance antagonistic actuation system allows NEUROExos to be controlled with two alternative strategies: independent control of the joint position and stiffness, for robot-in-charge rehabilitation mode, and near-zero impedance torque control, for patient-in-charge rehabilitation mode. In robot-in-charge mode, the passive joint stiffness can be changed in the range of 24-56 N·m/rad. In patient-in-charge mode, NEUROExos output impedance ranges from 1 N·m/rad, for 0.3 Hz motion, to 10 N·m/rad, for 3.2 Hz motion.