Jungtae Noh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jungtae Noh has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Jae-Seung Hwang
2 shared publications- Jae-Seung Hwang
School of Architecture, Chonnam National University, Gwangju 61186, Republic of Korea
2 shared publications - Salvatore Russo
Università Iuav di Venezia
2 shared publications Ahsan Kareem
NatHaz Modeling Laboratory, Department of Civil & Environmental Engineering and Earth Sciences, University of Notre Dame, Notre Dame, USA
1 shared publicationBehzad Ghadimi
1 shared publication- Maria Rosa Valluzzi
Department of Cultural Heritage, University of Padova, Piazza Capitaniato 7, 35139 Padova, Italy
1 shared publication
Latest Publications
- Open Access
Damping Ratio Estimation of Heavily Damped Structures Using State-Space Modal Responses
Vibration control systems are extensively utilized in structures to enhance their resilience against earthquakes and wind forces. However, structures with significant damping exhibit atypical damping behaviors, which impose constraints on the effectiveness of traditional modal analysis methods for discerning modal responses and estimating properties. To surmount this challenge, a novel State-Space-Based Modal Decomposition approach is proposed in this study. The State-Space-Based Modal Decomposition technique adeptly extracts modal responses and identifies modal attributes from acquired data of highly damped structures. The approach accurately calculates damping ratios and natural frequencies by scrutinizing the power spectrum within the deconstructed modal response. The validity of this method is confirmed through a numerical simulation with a three-degree-of-freedom system equipped with oil dampers and experimentation of a structure outfitted with a tuned mass damper system. The findings underscore that the transfer function of the modal response in state-space encompasses both displacement and velocity transfer functions. The results demonstrate that precise estimation of modal parameters can be accomplished by suitably evaluating the participation ratio of the two response components.
Open AccessDamping Ratio Estimation of Heavily Damped Structures Using State-Space Modal Responses
Vibration control systems are extensively utilized in structures to enhance their resilience against earthquakes and wind forces. However, structures with significant damping exhibit atypical damping behaviors, which impose constraints on the effectiveness of traditional modal analysis methods for discerning modal responses and estimating properties. To surmount this challenge, a novel State-Space-Based Modal Decomposition approach is proposed in this study. The State-Space-Based Modal Decomposition technique adeptly extracts modal responses and identifies modal attributes from acquired data of highly damped structures. The approach accurately calculates damping ratios and natural frequencies by scrutinizing the power spectrum within the deconstructed modal response. The validity of this method is confirmed through a numerical simulation with a three-degree-of-freedom system equipped with oil dampers and experimentation of a structure outfitted with a tuned mass damper system. The findings underscore that the transfer function of the modal response in state-space encompasses both displacement and velocity transfer functions. The results demonstrate that precise estimation of modal parameters can be accomplished by suitably evaluating the participation ratio of the two response components.
- Open Access
Verification of the Mode Decomposition Technique for Closely Distributed Modal Systems in the State Space Domain
This study aims to propose and validate the state space mode decomposition technique for precise mode separation of non-classical damping systems and closely distributed modal systems. To assess the reliability and applicability of this technique, a 40-story building with a tuned mass damper is investigated, and acceleration responses measured by the building’s health monitoring system are used for the verification of the technique. The mode separation results reveal that the separated modal power spectrum becomes distorted at neighboring natural frequency ranges when the performance index only considers the concentration of power spectral energy at the target natural frequency. However, by introducing an augmented performance index that includes a constraint condition to account for distortion, more accurate mode decomposition can be achieved.
Open AccessVerification of the Mode Decomposition Technique for Closely Distributed Modal Systems in the State Space Domain
This study aims to propose and validate the state space mode decomposition technique for precise mode separation of non-classical damping systems and closely distributed modal systems. To assess the reliability and applicability of this technique, a 40-story building with a tuned mass damper is investigated, and acceleration responses measured by the building’s health monitoring system are used for the verification of the technique. The mode separation results reveal that the separated modal power spectrum becomes distorted at neighboring natural frequency ranges when the performance index only considers the concentration of power spectral energy at the target natural frequency. However, by introducing an augmented performance index that includes a constraint condition to account for distortion, more accurate mode decomposition can be achieved.
- Open Access
- 6 June 2023
- Published by MDPI AG in Preprints.org
Verification of the Mode Decomposition Technique for the Closely Distributed Modal System in State Space
The aim of this study is to propose and validate the state space mode decomposition technique for precise mode separation of non-classical damping systems and closely distributed modal systems. To assess the reliability and applicability of this technique, a 40-story building with a tuned mass damper is investigated, and acceleration responses measured by the building's health monitoring system are used for the verification of the technique. The mode separation results reveal that the separated modal power spectrum becomes distorted at neighboring natural frequency ranges when the performance index only considers the concentration of power spectral energy at the target natural frequency. However, by introducing an augmented performance index that includes a constraint condition to account for distortion, more accurate mode decomposition can be achieved.
- 6 June 2023
- Published by MDPI AG in Preprints.org
Open AccessVerification of the Mode Decomposition Technique for the Closely Distributed Modal System in State Space
The aim of this study is to propose and validate the state space mode decomposition technique for precise mode separation of non-classical damping systems and closely distributed modal systems. To assess the reliability and applicability of this technique, a 40-story building with a tuned mass damper is investigated, and acceleration responses measured by the building's health monitoring system are used for the verification of the technique. The mode separation results reveal that the separated modal power spectrum becomes distorted at neighboring natural frequency ranges when the performance index only considers the concentration of power spectral energy at the target natural frequency. However, by introducing an augmented performance index that includes a constraint condition to account for distortion, more accurate mode decomposition can be achieved.
- Open Access
- 7 January 2019
- Published by Springer Nature in International Journal of Concrete Structures and Materials
- Vol. 13 (1) , 1-15
Experimental Verification of Modal Identification of a High-rise Building Using Independent Component Analysis
- 7 January 2019
- Published by Springer Nature in International Journal of Concrete Structures and Materials
- Vol. 13 (1) , 1-15
Open AccessExperimental Verification of Modal Identification of a High-rise Building Using Independent Component Analysis
- 1 October 2018
- Published by Elsevier in Composite Structures
- Vol. 202, 17-28
Assessment of FRP pultruded elements under static and dynamic loads
- 1 October 2018
- Published by Elsevier in Composite Structures
- Vol. 202, 17-28
Assessment of FRP pultruded elements under static and dynamic loads
- Open Access
- 9 August 2017
- Published by Copernicus GmbH in ISPRS Annals of the Photogrammetry, Remote Sensing and Spatial Information Sciences
- Vol. IV-2/W2, 187-193
LONG-TERM DYNAMIC MONITORING OF THE HISTORICAL MASONRY FAÇADE: THE CASE OF PALAZZO DUCALE IN VENICE, ITALY
Keywords: Long-term Monitoring, Palazzo Ducale, Ambient Vibration, Dynamic Monitoring, Noise, double-leaf Long-term dynamic monitoring of the masonry façade of Palazzo Ducale known as Doge’s palace in Venice, Italy was performed from September 2010 to October 2012. This article demonstrates the results of preliminary analysis on the data set of the first 12-month long monitoring campaign for out-of-plumb dynamic responses of the medieval façade of the monument. The aim of the analysis of the dynamic signals is to validate the data set and investigate dynamic characteristics of the vibration signature of the historical masonry wall in the long-term. Palazzo Ducale is a heavily visited heritage due to its high cultural importance and architectural value. Nevertheless, little is known about the dynamic behaviour of the double-leaf masonry façade. In this study, the dynamic properties of the structure are presented by dynamic identification carried out with the effect of the ambient vibration measured at four different locations on the façade and portico level. The trend and intensity of the vibration at each measurement locations are identified over the year. In addition, the issue on eliminating the noise blended in the signals for reliable analysis are also discussed.
- 9 August 2017
- Published by Copernicus GmbH in ISPRS Annals of the Photogrammetry, Remote Sensing and Spatial Information Sciences
- Vol. IV-2/W2, 187-193
Open AccessLONG-TERM DYNAMIC MONITORING OF THE HISTORICAL MASONRY FAÇADE: THE CASE OF PALAZZO DUCALE IN VENICE, ITALY
Keywords: Long-term Monitoring, Palazzo Ducale, Ambient Vibration, Dynamic Monitoring, Noise, double-leaf Long-term dynamic monitoring of the masonry façade of Palazzo Ducale known as Doge’s palace in Venice, Italy was performed from September 2010 to October 2012. This article demonstrates the results of preliminary analysis on the data set of the first 12-month long monitoring campaign for out-of-plumb dynamic responses of the medieval façade of the monument. The aim of the analysis of the dynamic signals is to validate the data set and investigate dynamic characteristics of the vibration signature of the historical masonry wall in the long-term. Palazzo Ducale is a heavily visited heritage due to its high cultural importance and architectural value. Nevertheless, little is known about the dynamic behaviour of the double-leaf masonry façade. In this study, the dynamic properties of the structure are presented by dynamic identification carried out with the effect of the ambient vibration measured at four different locations on the façade and portico level. The trend and intensity of the vibration at each measurement locations are identified over the year. In addition, the issue on eliminating the noise blended in the signals for reliable analysis are also discussed.