Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lluis Freixas has a total of 583 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Detection of RS Oph with LST-1 and modelling of its HE/VHE gamma-ray emission

    by K. Abe, S. Abe, A. Abhishek, F. Acero, A. Aguasca-Cabot, I. Agudo, C. Alispach, N. Alvarez Crespo, D. Ambrosino, L. A. Antonelli, et al.

    Context. The recurrent nova RS Ophiuchi (RS Oph) underwent a thermonuclear eruption in August 2021. In this event, RS Oph was detected by the High Energy Stereoscopic System (H.E.S.S.), the Major Atmospheric Gamma Imaging Cherenkov (MAGIC), and the first Large-Sized Telescope (LST-1) of the future Cherenkov Telescope Array Observatory (CTAO) at very-high gamma-ray energies above 100 GeV. This means that novae are a new class of very-high-energy (VHE) gamma-ray emitters. Aims. We report the analysis of the RS Oph observations with LST-1. We constrain the particle population that causes the observed emission in hadronic and leptonic scenarios. Additionally, we study the prospects of detecting further novae using LST-1 and the upcoming LST array of CTAO-North. Methods. We conducted target-of-opportunity observations with LST-1 from the first day of this nova event. The data were analysed in the framework of cta-lstchain and Gammapy, the official CTAO-LST reconstruction and analysis packages. One-zone hadronic and leptonic models were considered to model the gamma-ray emission of RS Oph using the spectral information from Fermi-LAT and LST-1, together with public data from the MAGIC and H.E.S.S. telescopes. Results. RS Oph was detected at 6.6σ with LST-1 in the first 6.35 hours of observations following the eruption. The hadronic scenario is preferred over the leptonic scenario considering a proton energy spectrum with a power-law model with an exponential cutoff whose position increases from (0.26 ± 0.08) TeV on day 1 up to (1.6 ± 0.6) TeV on day 4 after the eruption. The deep sensitivity and low energy threshold of the LST-1/LST array will allow us to detect faint novae and increase their discovery rate.


  • Open Access

    A new method of reconstructing images of gamma-ray telescopes applied to the LST-1 of CTAO

    by K. Abe, S. Abe, A. Abhishek, F. Acero, A. Aguasca-Cabot, I. Agudo, C. Alispach, N. Alvarez Crespo, D. Ambrosino, L. A. Antonelli, et al.

    Context. Imaging atmospheric Cherenkov telescopes (IACTs) are used to observe very high-energy photons from the ground. Gamma rays are indirectly detected through the Cherenkov light emitted by the air showers they induce. The new generation of experiments, in particular the Cherenkov Telescope Array Observatory (CTAO), sets ambitious goals for discoveries of new gamma-ray sources and precise measurements of the already discovered ones. To achieve these goals, both hardware and data analysis must employ cuttingedge techniques. This also applies to the LST-1, the first IACT built for the CTAO, which is currently taking data on the Canary island of La Palma. Aims. This paper introduces a new event reconstruction technique for IACT data, aiming to improve the image reconstruction quality and the discrimination between the signal and the background from misidentified hadrons and electrons. Methods. The technique models the development of the extensive air shower signal, recorded as a waveform per pixel, seen by CTAO telescopes’ cameras. Model parameters are subsequently passed to random forest regressors and classifiers to extract information on the primary particle. Results. The new reconstruction was applied to simulated data and to data from observations of the Crab Nebula performed by the LST-1. The event reconstruction method presented here shows promising performance improvements. The angular and energy resolution, and the sensitivity, are improved by 10 to 20% over most of the energy range. At low energy, improvements reach up to 22%, 47%, and 50%, respectively. A future extension of the method to stereoscopic analysis for telescope arrays will be the next important step.


  • Open Access

    Observations of the Crab Nebula and Pulsar with the Large-sized Telescope Prototype of the Cherenkov Telescope Array

    by H. Abe, K. Abe, S. Abe, A. Aguasca-Cabot, I. Agudo, N. Alvarez Crespo, L. A. Antonelli, C. Aramo, A. Arbet-Engels, C. Arcaro, et al.

    The Cherenkov Telescope Array (CTA) is a next-generation ground-based observatory for gamma-ray astronomy at very high energies. The Large-Sized Telescope prototype (LST-1) is located at the CTA-North site, on the Canary Island of La Palma. LSTs are designed to provide optimal performance in the lowest part of the energy range covered by CTA, down to ≃20 GeV. LST-1 started performing astronomical observations in 2019 November, during its commissioning phase, and it has been taking data ever since. We present the first LST-1 observations of the Crab Nebula, the standard candle of very-high-energy gamma-ray astronomy, and use them, together with simulations, to assess the performance of the telescope. LST-1 has reached the expected performance during its commissioning period—only a minor adjustment of the preexisting simulations was needed to match the telescope’s behavior. The energy threshold at trigger level is around 20 GeV, rising to ≃30 GeV after data analysis. Performance parameters depend strongly on energy, and on the strength of the gamma-ray selection cuts in the analysis: angular resolution ranges from 0.°12–0.°40, and energy resolution from 15%–50%. Flux sensitivity is around 1.1% of the Crab Nebula flux above 250 GeV for a 50 hr observation (12% for 30 minutes). The spectral energy distribution (in the 0.03–30 TeV range) and the light curve obtained for the Crab Nebula agree with previous measurements, considering statistical and systematic uncertainties. A clear periodic signal is also detected from the pulsar at the center of the Nebula.


  • Open Access

    MATRIX16: A 16-Channel Low-Power TDC ASIC with 8 ps Time Resolution

    by Joan Mauricio, Lluís Freixas, Andreu Sanuy, Sergio Gómez, Rafel Manera, Jesús Marín, Jose M. Pérez, Eduardo Picatoste, Pedro Rato, David Sánchez, et al.

    This paper presents a highly configurable 16-channel TDC ASIC designed in a commercial 180 nm technology with the following features: time-of-flight and time-over-threshold measurements, 8.6 ps LSB, 7.7 ps jitter, 5.6 ps linearity error, up to 5 MHz of sustained input rate per channel, 9.1 mW of power consumption per channel, and an area of 4.57 mm2. The main contributions of this work are the novel design of the clock interpolation circuitry based on a resistive interpolation mesh circuit and the capability to operate at different supply voltages and operating frequencies, thus providing a compromise between TDC resolution and power consumption.


  • HRFlexToT: A High Dynamic Range ASIC for Time-of-Flight Positron Emission Tomography

    by David Sanchez, Sergio Gomez, Joan Mauricio, Lluis Freixas, Andreu Sanuy, Gerard Guixe, Albert Lopez, Rafel Manera, Jesus Marin, Jose M. Perez, et al.

    Time-of-Flight positron emission tomography scanners demand fast and efficient photo sensors and scintillators coupled to fast readout electronics. This article presents the high resolution flexible Time-over-Threshold (HRFlexToT), a 16-channel application-specific-integrated circuit for silicon photomultipliers (SiPM) anode readout manufactured using XFAB 0.18- $\mu \text{m}$ CMOS technology. The main features of the HRFlexToT are a linear Time-over-Threshold with an extended dynamic range (10 bits) for energy measurement, low power consumption (≈ 3.5 mW/ch), and an excellent timing response. The experimental measurements show an energy linearity error of ≈ 3% and an energy resolution of about 12% at 511 keV. Single-photon time resolution measurements performed using an Fondazione Bruno Kessler (FBK) SiPM NUV-HD ( $4 \times 4$ mm 2 pixel, 40- $\mu \text{m}$ cell) and a Hamamatsu SiPM S13360-3050CS are around 142 and 167 ps full width at half maximum (FWHM), respectively. Coincidence time resolution (CTR) measurements with small cross-section pixelated crystals (LSO:Ce,Ca 0.4%, $2 \times 2 \times 5$ mm 3 ) coupled to the same Hamamatsu S13360-3050CS and FBK NUV-HD sensors yield a CTR of 117 ps and 119 ps, respectively. Measurements performed with a large cross-section monolithic crystal (LFS crystal measuring $25 \times 25 \times 20$ mm 3 ) and a Hamamatsu SiPM array S13361-6050NE-04 show a CTR of 324 ps FWHM after time-walk and time-skew correction.


  • Analogue sum ASIC for L1 trigger decision in Cherenkov Telescope cameras

    by J.A. Barrio, O. Blanch, J. Boix, E. Delagnes, C. Delgado, L. Freixas Coromina, D. Gascón, F. Guilloux, R. López Coto, G. Martínez, et al.


  • Open Access

    Analogue Sum ASIC for L1 Trigger Decision in Cherenkov Telescope Cameras

    by Joan Abel Barrio, Oscar Blanch, Joan Boix, Eric Delagnes, Carlos Delgado, Lluis Freixas Coromina, David Gascon, Fabrice Guilloux, Ruben Lopez Coto, Gustavo Martinez, et al.

    The Cherenkov Telescope Array (CTA) project aims to build the largest ground-based gamma-ray observatory based on an array of Imaging Atmospheric Cherenkov Telescopes (IACTs). The CTA will implement a multi-level trigger system to distinguish between gamma ray-like induced showers and background images induced by night sky background (NSB) light. The trigger system is based on coincident detections among pixels (level 0 trigger), clusters of pixels (level 1) or telescopes. In this article, the first version of the application specific integrated circuit (ASIC) for Level 1 trigger system is presented, capable of working with different Level 0 strategies and different trigger region sizes. In addition, it complies with all the requirements specified by the CTA project, specially the most critical ones as regards noise, bandwidth, dynamic range and power consumption. All these features make the presented system very suitable for use in the CTA cameras and improve the features of discrete components prototypes of the L1 trigger circuit in terms of compactness, noise, performance and power consumption.

  • Evaluation of the FlexToT ASIC on the readout of SiPM matrices and scintillators for PET

    by Javier Castilla, José-Manuel Cela, Albert Comerma, José-Manuel Fernández-Varea, Lluís Freixas, Lluís Garrido, David Gascón, Jesús Marín, Gustavo Martínez, José-Manuel Pérez, et al.

    We have designed FlexToT, a flexible application specific integrated circuit (ASIC) using time-over-threshold (ToT) techniques for the readout of silicon photomultiplier (SiPM) arrays in positron emission tomography (PET) detectors. The FlexToT ASIC accommodates 16 independent channels in a small die size (2.93 mm by 2.54 mm) with low power consumption (10 mW per channel), providing output signals whose duration is proportional to the current amplitude at its inputs. The threshold, gain and other parameters can be independently set for each channel in a flexible configuration that can be tailored to different applications and devices. Herein we present the results on the evaluation of the FlexToT ASIC operating as front-end electronics for SiPM arrays S11828-3344M from Hamamatsu (Japan) coupled to LYSO:Ce scintillators in a simple PET tomograph demonstrator. Each detector block is composed of a LYSO:Ce matrix coupled to 4 SiPM arrays in a 2×2 mosaic, totaling 64 pixels (8×8) which are read out by 4 FlexToT ASICs. Using this demonstrator we have obtained PET images of 22 Na point sources with spatial resolutions better than 2 mm full width at half maximum (FWHM), validating our design of the FlexToT ASIC on the readout of SiPM matrices and scintillators in PET applications.


  • FlexToT - Current mode ASIC for readout of common cathode SiPM arrays

    by Albert Comerma, David Gascon, Lluis Freixas, Lluis Garrido, Ricardo Graciani, Jesus Marin, Gustavo Martinez, Jose Manuel Perez, Pedro Rato Mendes, Javier Castilla, et al.

    A front end application specific integrated circuit (ASIC) for the readout of common cathode Silicon Photo-Multipliers arrays is presented with the following features: wide dynamic range, high speed, multi channel, low input impedance current amplifier, low power (≈10mW per channel), common cathode connection, directly coupled input with common mode voltage control and separated timing and charge signal output.A 16 channel prototype with 16 independent outputs for energy and pile-up detection and a single fast timing output is described. The low jitter current mode processing together with a configurable differential current mode logic (CML) output provides a timing signal suitable for Time of Flight (TOF) applications, such as TOF-PET (Positron Emission Tomography). Each channel delivers a digital output of a Time Over Threshold (TOT) type with a pulse width proportional to peak current (charge) input. The current mode input stage features a novel double feedback; a low speed feedback loop keeps input node voltage constant while a higher speed feedback loop keeps input impedance low. Dedicated circuitry allows SiPM high over-voltage operation, thus maximizing Photon Detection Efficiency (PDE) and timing resolution. Design was submitted in June 2012 in Austria Microsystems (AMS) 0.35 μm HBT BiCMOS technology and is under test.


  • Front End ASIC design for SiPM readout

    by A Comerma, D Gascón, L Garrido, C Delgado, J Marín, J M Pérez, G Martínez, L Freixas